ED34-862 Specifications

FXKQ-MA 145

4

2. Specifications

Ceiling Mounted Cassette Corner Type

Note:∗1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.∗2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

∗4 Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

5 Refer to page 150 for Fan Motor Input.

Model FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE

∗1 Cooling Capacity (19.5°CWB)

kcal/h 2,500 3,200 4,000 6,300

Btu/h 9,900 12,600 16,000 24,900

kW 2.9 3.7 4.7 7.3

∗2 Cooling Capacity (19.0°CWB) kW 2.8 3.6 4.5 7.1

Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate

Dimensions: (H×W×D) mm 215×1,110×710 215×1,110×710 215×1,110×710 215×1,310×710

Coil (Cross Fin Coil)

Rows×Stages×Fin Pitch mm 2×11×1.75 2×11×1.75 2×11×1.75 3×11×1.75

Face Area m² 0.180 0.180 0.180 0.226

Fan

Model 3D12H1AN1V1 3D12H1AN1V1 3D12H1AP1V1 4D12H1AJ1V1

Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan

Motor Output × Number of Units W 15×1 15×1 20×1 45×1

Air Flow Rate (H/L)m³/min 11/9 11/9 13/10 18/15

cfm 388/318 388/318 459/353 635/530

Drive Direct Drive Direct Drive Direct Drive Direct Drive

Temperature Control Microprocessor Thermostat for Cooling and Heating

Microprocessor Thermostat for Cooling and Heating

Microprocessor Thermostat for Cooling and Heating

Microprocessor Thermostat for Cooling and Heating

Sound Absorbing Thermal Insulation Material Polyethylene Foam Polyethylene Foam Polyethylene Foam Polyethylene Foam

Piping Connections

Liquid Pipes mm φ6.4 (Flare Connection) φ6.4 (Flare Connection) φ6.4 (Flare Connection) φ9.5 (Flare Connection)

Gas Pipes mm φ12.7 (Flare Connection) φ12.7 (Flare Connection) φ12.7 (Flare Connection) φ15.9 (Flare Connection)

Drain Pipe mmVP25

External Dia. 32Internal Dia. 25

VP25External Dia. 32Internal Dia. 25

VP25External Dia. 32Internal Dia. 25

VP25External Dia. 32Internal Dia. 25

Machine Weight (Mass) kg 31 31 31 34

∗4 Sound Level (H/L) (220V) dBA 38/33 38/33 40/34 42/37

Safety Devices Fuse.Thermal Fuse for Fan Motor.

Fuse.Thermal Fuse for Fan Motor.

Fuse.Thermal Fuse for Fan Motor.

Fuse.Thermal Fuse for Fan Motor.

Refrigerant Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve

Connectable Outdoor Units R-410A PA Series R-410A PA Series R-410A PA Series R-410A PA Series

Decoration Panels(Option)

Model BYK45FJW1 BYK45FJW1 BYK45FJW1 BYK71FJW1

Panel Color White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5)

Dimensions: (H×W×D) mm 70×1,240×800 70×1,240×800 70×1,240×800 70×1,440×800

Air Filter Resin Net(with Mold Resistant)

Resin Net(with Mold Resistant)

Resin Net(with Mold Resistant)

Resin Net(with Mold Resistant)

Weight kg 8.5 8.5 8.5 9.5

Standard Accessories

Operation Manual. Installation Manual. Paper Pattern for Installation. Drain Hose. Clamp Metal. Insulation for Fitting. Sealing Pads. Clamps. Screws. Washers. Positioning Jig for Installation. Insulation for Hanger Bracket. Air Outlet Blocking Pad.

Operation Manual. Installation Manual. Paper Pattern for Installation. Drain Hose. Clamp Metal. Insulation for Fitting. Sealing Pads. Clamps. Screws. Washers. Positioning Jig for Installation. Insulation for Hanger Bracket. Air Outlet Blocking Pad.

Operation Manual. Installation Manual. Paper Pattern for Installation. Drain Hose. Clamp Metal. Insulation for Fitting. Sealing Pads. Clamps. Screws. Washers. Positioning Jig for Installation. Insulation for Hanger Bracket. Air Outlet Blocking Pad.

Operation Manual. Installation Manual. Paper Pattern for Installation. Drain Hose. Clamp Metal. Insulation for Fitting. Sealing Pads. Clamps. Screws. Washers. Positioning Jig for Installation. Insulation for Hanger Bracket. Air Outlet Blocking Pad.

Drawing No. C : 3D038813A

( ) ( ) ( ) ( )

Conversion Formulae

kcal/h=kW×860Btu/h=kW×3412

cfm=m³/min×35.3