    RTC80.7XX(09) Weely Programming thermostat Mounting lnstructions

    Technical data:Voltage IPower consumptionSetting rangeLimitation rangeSwitching differentialAmbient temperatureProtective housingHousing materialFloor sensor

    : AC230V(AC110V I AC24V available):2W: 5C -90C:4"C -99C (factory setting: 28"C-32"C1: +0.5K: -5-50C: lP20: anti-flammable PC: rubber-thermoplastic NTC sensor,cable length is 3m

    RTC80.7XX hleely Programmi ng thermostatWeekly circulation, it is possible to set 6 periods called eventseach day with different temperatures, also you can select "manualmode" or "comfort mode" according to your individual requirements.The thermostat is recommended for th6 control of electric heatingdevices or on/off valve actuator used in water-based heating systems.Selection Table:

    Model Current ApplicationRTC80.713 3A For control of electric actuator or electrothermal actuatorRTC80.723 3A For control of electric actuator or electrothermal actuatorRTC80.716 16A For control of heatinq cable or other heatinq equipments

    Daily use of the thermostat1) menu umuPress the "ffi" key to select manual mode or clock-controlledprogramme mode, use the "A" or "v" key to enter into comfortmode in clock-controlled programme mode2) plus "4" & minus ov"Press the "4" or \" key to increase or decrease your set value3) clock "O"Press the "O" key to set the time and daypress the 19" key till the day start blinking, use the "A" or "v" keyto setthe day, press the "O" key to confirm the setting and thehours start blinking, use the "1" or "V" key to set the hburs, pressthe "f or Y to confirm the setting and the minutes start blinking,use the "A" or "V" key to set the minutes, press the "0" key toaccept the settings

    4 ) on/off "(|)"Press the "t!)" key to switch on or switch off the thermostatthe setted temperature and the time will be displayed on left sideof screen alternately, and the room temperature can be directlyread out on right side of screen

    Programming: 6-event time and temperaturePress the "f,R" key for 5 seconds to begin programming

    Note:1) the pre-progratmmed setpoint (1 5T ) for event g & 4is the same as event 2,ple.ase resef it aciording to you individual requirement2) symbol "off" will be displayed if the setpoint reachs the minimum sef valueand the thermostaf r's snrifched.off in this eventAdvanced settings (qualified person preferred)Press the " ffi' key simultaneously switching on the thermostat toenter into the advanced setting mode(when the device is switched off)

    Key Symbol Setting A OrV

    mIos

    1 ADJ lemperatu re cal ibratior Adjust measured tem perature2 SEN Sensor mode

    lN : built-in sensorOUT : floor sensorALL : both sensor(floor sensor is the limit sensor)

    3 HI Max. Temperature Max. Limitation temperaturesetpoint (99C )4 LO Min. Temperature Min. Limitation temperaturesetpoint (4C )5 ADA Adaptive functidfi= ON" : preheating-30 miw+erearly-OFF: cancel adaptive function6 PRG Set vacation mode 512 day mode6/1 day mode7 day mode

    210

    7 FAC Reset tofactory settingsProgramming parameters wil Ibe reset to factory settingswhen symbol r'- - -r' appears

    Sehsor failure:Please select the right sensor mode when operation, it will display theoErr" symbol on screen for sensor failure, thermostat must be checkedtill the fault is eliminated

    Fu nction:'8" manual modeThe scheduled event program is overridden, set the temperatureaccording to your individual requirements an d the thermostatwilloperate at this temperature permanently"O" clock-controlled programme modeThe day has been split into 6 events, the thermostat will operateautomatically according to the programmed temperature and timeilf &"O" comfort modeThe temperature can be temporarily changed for a single event, thecomfort mode temperature is reset at the next event, and the ther-

    GI wake-up, event 1ffi Leave (am), event 2ffi Return (am)' event 3ffi Leave (pm), event 4ffi Return (pm), event 5 .ffi .steep, event 6ffi Heating onffi "Key-lock" function is activatedffi Set sensor mode: built-in/floor/both sensorsffi Set vacation operating modeffi Setting Max and Min allowed temperqtrr_1 , -:=ffi Early-start adaptive functionffi Sensor calibration to ensure accurate temperature measurementffi Display with back light, stay on for 20 secondsffi LcD disptay for better read outffi display actual room temperature when switch-off"Key.;gck" functionPress both the "A" and "v" keys for 5 secs to engage/disengage the"key-lock" function ( 'fl' symbol appear means "key-lock" function isactivated; disappear means "key-lock" function is deactivated)

    Key Event Symbol Time Y Temperature AVms

    UoI(n

    I + 06: 00 oooag)o5CL3.3(D

    20"c (t)oEo(a0)33oo-o3Eol)go

    2 Or 08' 00 15C3 & 11: 30 15C4 s 12- 30 15C5 Oe 172 00 22"C6 ( 222 00 15CoE)

    ct)I1 + 08: 00 22"C2 ( 23, 00 15C

    HVAC CONTROLS PRODUCTS 2010 E 80 1.0

  • 7/29/2019 izmenat graniterm termostat.pdf

    2/2

    RTC80.7XX(09\Weely,Programming thermostet ,Mounting tnstruetionsExplanation of symbols ..

    Event indicatorSet value/time displayDav numberPlus/ririnus keyMenu key

    Clock-controlled:prcgrapme modems.nualmodeActual teqr.peratureKev locltHebting onOn/off switchTemperature SensorClock key

    lnstall the housing cover and lock the externalframe

    Wirins diaoram

    ot @tlnstallthe thermostat in electrical connection box with screws

    Dimension

    Mounting steps:

    /+5

    ,\, lvNLAC230V

    80.716 ,:;, =,,ffi J,hJ"- H

    L1 N1164 AC230V

    80.723 -,-h Ytttlll n33g L1o Lrrr 3>a6olf

    tiNLAC230V

    201CIE80 1.0VAC CONTROLS PRODUCTS