Kathrein Inc., Scala Division Post Ofce Box 4580 Medford, OR 97501 (USA) Phone: (541) 779-6500 Fax: (541) 779-3991 Email: communicati ons@kathr ein.com Interne t: www.kathrein-sc ala.com 10865-A 936.2384/b  782 10215, 782 10216 782 10257, 782 10265  Duplexer The duplexer is designed to combine/split AMPS Tx and Rx signals to/from one common Tx/Rx antenna in order to save feeder cable and antenna costs  Suitable for indoor use.  Built-in DC stop. Specications: 782 10215 782 10216 782 10257 782 10265 Frequency range Low band 824–851 MHz 824–851 MHz 824–846.5 MHz 824–846.5 MHz High band 869–896 MHz 869–896 MHz 869–891.5 MHz 869–891.5 MHz Impedance 50 ohms 50 ohms 50 ohms 50 ohms VSWR <1.25:1 <1.25:1 <1.25:1 <1.25:1 Insertion loss AntennaLow band <0.5 dB <0.5 dB <0.5 dB <0.5 dB High bandAntenna <0.5 dB <0.5 dB <0.5 dB <0.5 dB Isolation Low bandHigh band >65 dB >65 dB >70 dB >70 dB Maximum input power <400 watts (high band) <400 watts (high band) <400 watts (high band) < 800 watts (high band) max. 16 carrier s max. 16 carrier s max. 16 carrier s max. 32 carrier s Intermo dulation (2x20w) IM3: <-160 dBc IM3: <-160 dBc IM3: <-160 dBc IM3: <-160 dBc T emperature range -20° to +55° C -20° to +55° C -20° to +55° C -20° to +55° C Connecto rs 7/16 DIN female N female 7/16 DIN female 7/16 DIN female Application Indoor Indoor Indoor Indoor Dimensions* 9 x 6.7 x 3.1 inches 9 x 6.9 x 3.1 inches 9 x 6.7 x 3.1 inches 9 x 6.7 x 4.4 inches (229 x 170 x 80 mm) (229 x 175 x 80 mm) (229 x 170 x 80 mm) (229 x 170 x 112 mm) Weight 5.7 lb (2.6 kg) 5.7 lb (2.6 kg) 5.7 lb (2.6 kg) 6.6 lb (3 kg) Shipping dimensions 12.2 x 9.9 x 6.4 inches 12.2 x 9.9 x 6.4 inches 12.2 x 9.9 x 6.4 inches 12.2 x 9.9 x 6.4 inches (309 x 252 x 162 mm) (309 x 252 x 162 mm) (309 x 252 x 162 mm) (309 x 252 x 162 mm) Mounting Mount using four screws Mount using four screws Mount using four screws Mount using four screws (max. 4 mm diameter) (max. 4 mm diameter). (max. 4 mm diameter) (max. 4 mm diameter) *Includes connectors and mounting feet 782 10215 782 10257 782 10265 782 10216 9 inches (229 mm) 3.1 inches (80 mm) 6.9 inches (175 mm) 6.7 inches (170 mm) 3.1 inches (80 mm) 4.4 inches (112 mm) or Order Information: Model Description 782 10215 Indoor duplexer with DIN connectors 782 10216 Indoor duplexer with N connectors 782 10257 Indoor duplexer with DIN connectors 782 10265 Indoor duplexer with DIN connectors

Transcript of 78210215

8/12/2019 78210215

http://slidepdf.com/reader/full/78210215 1/2

Kathrein Inc., Scala Division Post Office Box 4580 Medford, OR 97501 (USA) Phone: (541) 779-6500 Fax: (541) 779-3991Email: [email protected] Internet: www.kathrein-scala.com

10865-A936.2384/b

  782 10215, 782 10216

782 10257, 782 10265

  Duplexer

The duplexer is designed to combine/split AMPS Tx and Rxsignals to/from one common Tx/Rx antenna in order to save

feeder cable and antenna costs

  Suitable for indoor use.

  Built-in DC stop.

Specifications: 782 10215 782 10216 782 10257 782 10265

Frequency rangeLow band 824–851 MHz 824–851 MHz 824–846.5 MHz 824–846.5 MHzHigh band 869–896 MHz 869–896 MHz 869–891.5 MHz 869–891.5 MHz

Impedance 50 ohms 50 ohms 50 ohms 50 ohms

VSWR <1.25:1 <1.25:1 <1.25:1 <1.25:1

Insertion lossAntenna→ Low band <0.5 dB <0.5 dB <0.5 dB <0.5 dBHigh band→Antenna <0.5 dB <0.5 dB <0.5 dB <0.5 dB

IsolationLow band↔High band >65 dB >65 dB >70 dB >70 dB

Maximum input power <400 watts (high band) <400 watts (high band) <400 watts (high band) <800 watts (high band)max. 16 carriers max. 16 carriers max. 16 carriers max. 32 carriers

Intermodulation (2x20w) IM3: <-160 dBc IM3: <-160 dBc IM3: <-160 dBc IM3: <-160 dBc

Temperature range -20° to +55° C -20° to +55° C -20° to +55° C -20° to +55° C

Connectors 7/16 DIN female N female 7/16 DIN female 7/16 DIN female

Application Indoor Indoor Indoor Indoor

Dimensions* 9 x 6.7 x 3.1 inches 9 x 6.9 x 3.1 inches 9 x 6.7 x 3.1 inches 9 x 6.7 x 4.4 inches(229 x 170 x 80 mm) (229 x 175 x 80 mm) (229 x 170 x 80 mm) (229 x 170 x 112 mm)

Weight 5.7 lb (2.6 kg) 5.7 lb (2.6 kg) 5.7 lb (2.6 kg) 6.6 lb (3 kg)

Shipping dimensions 12.2 x 9.9 x 6.4 inches 12.2 x 9.9 x 6.4 inches 12.2 x 9.9 x 6.4 inches 12.2 x 9.9 x 6.4 inches(309 x 252 x 162 mm) (309 x 252 x 162 mm) (309 x 252 x 162 mm) (309 x 252 x 162 mm)

Mounting Mount using four screws Mount using four screws Mount using four screws Mount using four screws(max. 4 mm diameter) (max. 4 mm diameter). (max. 4 mm diameter) (max. 4 mm diameter)

*Includes connectors and mounting feet

782 10215

782 10257

782 10265

782 10216

9 inches

(229 mm)

3.1 inches(80 mm)

6.9 inches

(175 mm)

6.7 inches(170 mm)

3.1 inches(80 mm)

4.4 inches(112 mm)

or

Order Information:

Model Description

782 10215 Indoor duplexer with DIN connectors

782 10216 Indoor duplexer with N connectors

782 10257 Indoor duplexer with DIN connectors

782 10265 Indoor duplexer with DIN connectors