XP3-1/XP3-2 TEST RESULTS
There were several factors contributing to the poor performance of these DFM PPM-focused 75-MW klystrons:
1. Although the smaller DFM gun ceramic had been tested in a beam tester with
3.2 s pulses at full voltage, it had been designed for only 1.5 s (before the pulselength was doubled). The gun in XP3 2 proved to be not sufficiently sturdy forthe longer pulse length. The ceramic in that tube was damaged early at test;subsequently, XP3-2 was limited in beam voltage and peak power.
2. The output cavities in these klystrons have a potential trapped mode atapproximately 11.7 MHz. This results from the mismatch presented to the outputcavities by the mode converters ahead of the windows. We suppress it bycoupling resonant loss cavities between the output cavity and the 2 windows.These cavities are designed so that, when located correctly on the waveguide,they match the window and mode converter to the output cavity at 11.7 GHz. Thetrapped mode is then loaded over a narrow frequency range. The potential for this
oscillation, however, is exacerbated further if the 3 penultimate klystroncavities, which are tuned well above the operating frequency in order to improve rfbeam bunching, and are therefore are tuned close to the 11. 7 GHz frequency. InXP3-1 the resonant loss cavity was placed at an incorrect location. Also, in bothklystrons, the penultimate cavities were tuned too close to 11.7 GHz.
3. The 2 polepieces in the gun electromagnet, which is used to launch the beam intothe PPM stack, were split in both klystrons, causing transverse magnetic fields toexist in the vicinity of the cathode. These fields were an order of magnitude
higher that we specify for our PPM stacks (about 1% vs. 0.2% of the axial field).This may have caused cork-screwing in the beams of both klystrons. Evidenceof that effect may have been the reduced available range of electromagnet currentin adjusting the size of the klystron beam for optimum output power.
4. The same comment applies to potential transverse magnetic field in the PPMclamshells, which was also measured to be as high as 0.8%. Although theclamshells had been tested for such fields, the tests (which must measure a few
transverse gauss in the presence of an axial field of 3000 Gauss) werequestionable. They have been repeated and the results are shown in Fig. 10.Unfortunately no analytical or simulated predictions have existed on the limits fortransverse fields in PPM stacks. This is being remedied by using a recentlyavailable 3D code.
8/14/2019 Mac Caryotakis 1106
4/11
SLAC PPM KLYSTRON DEVELOPMENT
50 XP
1996-99
1
XP 1
1997-99
2
XP 3 Diode
2001
XP 3-1 (DFM)
2002
XP 3-2 (DFM)
2002
XP 4
2003Power Output
Design
Attained
50
50 60
75
70 - 90
Beam Tester 75
50 70
75
30 40
75
Pulse Length
Design
Attained
1.2
2.4
1.5
3.0
1.5
3.2
3.2
3.2
3.2
2.8
3.2
PRF
DesignAttained
60120
6060
120120
120120
12060
120
Best results
(simultaneous)
Po-s-Hz-%50-2.4-120-57 79-2.8-1-62 1wk 490kV
3.2s, 120 pps
70-0.3-120-55
50-3.2-120-39
40-0.5-120-31
30-2.8-120-24
Polepieces Brazed to
form the drift
tube
Brazed to
s.s. tube
Brazed to
s.s. tube
Clamp on Clamp on Brazed to
s.s. tube
Gun Seal Large (11.5)
tapered
Large,
tapered
Small (9),
straight
Small, straight Small, straight Large,
tapered
Gun Stability3 Good Good
LC
Good
LC
Good
LC
Good
Gun
Breakdown4
LC
Beam Transport
(no rf) Excellent
99.9% Fair 99%
4
Good 99.5%
Good 99.5%
but a narrow
coil range
Good 99.5%
Output Stability Excellent Excellent N/A 11.7GHz
Output
Oscillation4
Good
Average Power
Design
Attained
3.6 kW
14.4 kW
0.1kW0.2 kW
DC
23 kW
49 kW
29 kW
19.2 kW
29 kW
10 kW
29 kW
1Tube originally tested in 1997, but was retested in 1999 for longer pulse length and higher PRF.
Perveance: 0.6. All subsequent klystrons built with K=0.75. Tube was rebuilt once in order to coat the
polepiece IDs and eliminate multipactor.
8/14/2019 Mac Caryotakis 1106
5/11
5
Modifications incorporated to the rebuilt XP 3-2
Cavity tuning changed for optimum efficiency and oscillationavoidance.
Resonant loss cavity placed at correct location.
Gun coil split polepiece remade without split.
Gun from XP 3-1 will be used in place of the XP 3-2 gun,which was damaged from arcing.
And, most important, no more 3.2 sec pulses to triggeroscillations or cause gun breakdowns
8/14/2019 Mac Caryotakis 1106
6/11
8/14/2019 Mac Caryotakis 1106
7/11
7
110 tunings investigated: Saturated Gain and Pout vs. Sum of
the frequencies of cavities 5, 6 and 7. Multiple solutionsfound which avoid high gradients and pre-determined
unstable frequencies, and also give good BW, gain and power
out.
45
50
55
60
65
70
75
80
34800 35000 35200 35400 35600 35800 36000
Sum of F's (MHz)
Gain,P
wr
Pout
Gain
XP3 XP3 Rebuild
11700 X 3
8/14/2019 Mac Caryotakis 1106
8/11
8
Old Loss cavity location S11 vs. new location shows better than 10dB improvement in reflection from
mode converter-load assy at 11.7GHz (good match).
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2
0
1.3 1.5 1.7 1.9 2.1 2.3 2.5
Loss Cavity Location (inches)
S11
(dB)
Meas. Load A: TS1794-4
Calc. Load A
New Location
Old
8/14/2019 Mac Caryotakis 1106
9/11
8/14/2019 Mac Caryotakis 1106
10/11
Transverse B fields at gap centers (minimum points on curve below) average > 0.2% for the lower XP3-1 clamp-on
0.0%
0.2%
0.4%
0.6%
0.8%
1.0%
-500 -450 -400 -350 -300 -250 -200 -150 -100 -50 0
mm
10
Bt/Bz(RMS)
8/14/2019 Mac Caryotakis 1106
11/11
11