    EPActEfficientValue Line Family of Products

    Open Drip Proof1-400HP200, 230/460, 460, 575 VoltGEGARD18007 Insulation SystemInverter CapableCast Iron Frame & Endsheilds1.15 S.F.F-1 to F-2 modifiable

    Totally Enclosed Fan Cooled - 150HP200, 230/460, 460, 575 VoltGEGARD18007 Insulation SystemInverter CapableCast Iron Frame & Endsheilds1.15 S.F.F-1 to F-2 modifiableC-Face or Footmount

    Totally Enclosed Fan CooledSevere Duty - 250HP230/460, 460, 575 voltGEGARD18007 Insulation Sys.Inverter CapableFull Cast Iron Construction1.15 S.F.F-1 to F-2 modifiableShaft Slinger

    Totally Enclosed Fan CooledExplosion Proof1-200HP230/460 VoltFull Cast Iron ConstructionBrass Flinger on both endsNon-Sparking fanOversized Conduit Box

    NEMA Premium7

    Efficient

    E$P Open Drip Proof1-300HP230/460, 575 voltGEGARD18007 Insulation System

    Inverter CapableCast Iron Frame & Endsheilds1.15 S.F.

    X$D Ultra7 Extra Severe DutyTotally Enclosed Fan Cooled1-300HP230/460, 460, 575 volt

    Full Cast Iron Construction1.15 S.F.GEGARD20007 Insulation SystemSix Star Bearing System with 0.04 ipsRecessed Steel Reinforced V-Ring Slinger

    X$D Ultra7 841 Extra Severe DutyTotally Enclosed Fan Cooled1-250HP460, 575 volt

    Full Cast Iron ConstructionMeets or exceeds IEEE 841 StandardsGEGARD20007 Insulation SystemSix Star Bearing System with 0.04 ipsD.E. and O.D.E. Inpro Seal

    Direct CurrentMotors

    Permanent Magnet DC - 3HP90 or 180 VDC FieldC-Face w/bolt on feetProvision for tachometerDrive CapableCont. Torque to 5% base speed

    with free wheeling diode

    Kinamatic II1-500HP240, 500 VDC Armature150/300 VDC FieldTIG Welded Copper to Copper

    CommutatorsDPFG, DPFG-BV, TE

    CD6000-CD6900500-2000HP240, 500 VDC Armature150/300 VDC FieldSturdy TREC7 Main and CommutatingField Coils are StandardTIG Welded Copper to Copper

    CommutatorsDPG, DPG-BV, TEFC

  • 7/27/2019 GEBrochure DEAM 0377Cgeneric

    3/6

    Application Specific

    X$D Ultra7 661 Extra Severe DutyTotally Enclosed Fan CooledHeat Exchanger5-75 HP

    380, 460 voltMeets API 661 & IEEE 841 StandardsGEGARD20007 Insulation SystemRoller Bearing L10 Life: 40,000 hrsD.E. and O.D.E. Inpro SealIP-55 Protection4 pt Cast-in-lifting Lugs for

    Safe and Easy Vertical Lifting

    X$D Ultra7 Extra Severe DutyTotally Enclosed Fan CooledHigh Torque - NEMA Design C

    40-300 HP

    230/460, 460, 575 voltDesign C1.15 S.F.GEGARD20007 Insulation SystemSix Star Bearing System with 0.04 ipsRecessed Steel Reinforced V-Ring Slinger

    Vertical MotorsWeather-Protected (WPI)

    5-300 HP230/460, 460 Volt (Part Winding Start)GEGARD18007 Insulation SystemCast Iron Frame & EndshieldStamp Steel Top HatBall RatchetHigh ThrustInverter Capable

    Custom Vertical1-800 HP230, 460, 2300 or 4160 VoltCast Iron FrameWPI, WPII, TEFCSolid or Hollow Shaft DesignsNormal, High or Extra-High Thrust DesignsStandard or Energy Efficient Electrical Designs

    MD800 Mill Duty5-500 HPMeets AISE StandardSplit Frame DesignDouble Tapered ShaftClass H InsulationTRECTM Coils

    Electric VehicleSystems2-30 HP36 to 80 VDCPartial motor design

    for OEM replacement19T or 10T female shaft extensionTraction, Hydraulic Pump

    and Power Steering

    Adjustable Speed Motor A$D1.5-300 HP230/460, 460, 575 voltTotally Enclosed

    GEGARD20007

    Insulation SystemInfinite:1 Constant Torque Speed Range3 N.C. ThermostatUL and CSA recognizedProvision to Install Encoder

    Commercial Refrigeration81 mm & 92 mm2-90 watts100-1650 RPMUL and CSA listedStandard and High EfficientShaded Pole or Permanent

    Split CapacitorThreaded Shaft

    Totally Enclosed Fan Cooled (IP54)High Speed3-150 HPC-Face Footed230/460 Volt, 60 Hz at 1.15 SF200/400 Volt, 50 Hz at 1.15 SF

    and Derated to next lowest HPGEGARD18007 Insulation SystemCE MarkedQty 2 N.C. Thermostat

  • 7/27/2019 GEBrochure DEAM 0377Cgeneric

    4/6

    Above NEMA

    500 FrameLow & Medium Voltage250-800HP460,2300, 4160, 6600 VoltODP, WPII, TEFCVertical or Horizontal ConfigurationCustom Polyseal Insulation available

    Wound Rotor Motors500-15,000 HP (11,000 kW)Up to 6600 VoltsFabricated Steel Frame Construction

    NEMA & IEC DesignsWPI, WPII, TEAAC, TEWAC

    Large DC MotorsUp to 12,000 HP (8,952 kW)Class F or H insulationSplit magnet frame for easy maintenanceHigh thrust & torque capabilitiesMarine Generation and Propulsion,Mining & Metal applications

    450-7000 Frame HorizontalLow & Medium Voltage Induction350-2,000 HP (250-1,400 kW)Up to 6600 Volts2 to 10 PoleNEMA & IEC DesignsAPI 541, 547TEFC

    8200-8900 Frame HorizontalMedium & High Voltage Induction500-15,000 HP (11,000 kW)Up to 13800 VoltsFabricated Steel Frame ConstructionNEMA & IEC DesignsAPI 541, 547WPI, WPII, TEAAC, TEWAC

    Large AC Synchronous Motors1000-100,000 HP (75,000 kW)Up to 15,000 VoltsSpecifications & Standards,

    NEMA, CSA, IEEE, IEC, API 546Solid Salient Rotor Design for 4 & 6 PoleCustomized design available for various

    applicationsProven design and manufacturing

    techniques

    8200-8900 Frame VerticalMedium & High Voltage Induction500-12,500 HP (9,000 kW)Up to 13800 Volts

    Fabricated Steel Frame ConstructionNEMA & IEC DesignsAPI 541Normal or High Thrust DesignsWPI, WPII, TEAAC, TEWAC

    GeneratorsAC Design Up to 75,000 kVA

    Up to 13,800 VoltsVertical and horizontal configurationsSpecifications & Standards, NEMA,

    CSA, IEEE, IEC, API4 & 6 pole for Steam and

    Gas Turbine applications8 pole and above for small hydro apps.All types of enclosures are available

  • 7/27/2019 GEBrochure DEAM 0377Cgeneric

    5/6

    Low Voltage Drives

    AF-600 GP General Purpose Drive1/3 - 50 HP, 230 Volt1/2 - 1,200 HP, 460 Volt

    1- 1,350 HP, 575/690 VoltIdeally suited for constant torque and variabletorque applications

    NEMA 1, 4, & 12 Stand Alone drive optionsBuilt-in Modbus RTUQuick Menu, Closed Loop Vector with built-in

    encoder feedback and On-Board Manual

    AF-60 LP Micro Drive1/4 - 10 HP230 & 460 VoltCompact with built-in brake chopper, RFI Filterand removable keypad with Quick Menu, H-O-A,and single turn potentiometerIdeal for pumps, fans, mixers, and conveyors

    Medium Voltage Drives

    Dura-Bilt 5i MV400-5,000 HP298-3,730 kWH2000-2400, 3000-3400, 4000-4200 VoltsCompact DesignHeat Pipe Air-Cooled InverterIEEE 519 CompliantSensorless Vector ControlCopper Wound Transformer Included as Standard5 Year Warranty

    AF-600 FP Fan/Pump Drive1 - 60 HP, 230 Volt1 - 1,350 HP, 460 & 575 VoltIdeally suited for HVAC, pumps, blowers, and compressorsNEMA 1, 12 Stand Alone drive optionsBuilt-in Modbus RTU, Metasys N2, & Apogee FLN

    P1 networks. Options for BACnet, LonWorks,DeviceNet, and Profibus DP

    Quick Menu, Fan/Pump Macros, 4 Auto-Tune PIDControllers, Cascade Pump Controller, Real Time

    Clock, Energy Savings Mode, and On-Board Manual.

  • 7/27/2019 GEBrochure DEAM 0377Cgeneric

    6/6

    imagination at workg

    GE Motors

    USA

    Fort Wayne, IN 46802

    800 541 7191

    www.gemotors.com

    82007 General Electric Company All rights reserved.GE,g, X$D Ultra, GEGARD1800, GEGARD2000, and the Six StarBearing System are trademarks of General Electric Company.

    NEMA Premium is a trademark of NEMA.

    DEA-M0377C 1007

    Genuine Parts

    GEGARD Insulation SystemGuaranteed Ultimate Performance on Inverter Power

    GE Genuine Parts were designed for your GE motors.They will always fit perfectly saving you time and effort.

    Coils from other suppliers almost always require somE form-ing and bending which can damage the coil insulation andincrease labor time. GE armature coil kits include clips andsoldering blocks. These fit perfectly and are two less itemswe have to chase down when we rewind an armature

    Robert N. MilesGE Energy Services

    Superior Product Quality

    Genuine GE parts built to original designs usinglatest materials and manufacturing processes.

    A full complement of spare parts are availablefor the entire range of GE motors.

    Exact Fit and Specification

    Average installation time is reduced comparedto competitor parts in GE motors.

    World Class Service

    Our Dedicated Renewal Parts Team is fully integratedwith technology and manufacturing.

    Identification of common spare parts is basedsimply on machine model or serial number

    Spare Parts Program

    Customers minimize downtime with an adequatespare parts inventory plan for their GE motors.

    CoilsArmatureFieldStatorAmmortisseurSynchronous Rotor PolesEqualizer

    Commutators/CollectorsReplacement Commutator

    Slip Ring Assemblies

    Brush AssemblyBrushesSpringsBrushholders

    BearingsSleeve BearingsOil Rings

    ExcitersRotor & Stators

    AccessoriesAir FiltersMolded Equalizer Trays

    Speed Limit SwitchesHeatersThermostatsThyristorsConverter AssembliesOil GuagesFansBlower Assembly or Wheel

    GEGARD1800TMThis system exceeds NEMA MG1-31(which is 3.1 times the nameplate volt-age) for motors operating on inverters.The insulation system is comprised ofclass F materials and the varnish is non-hygroscopic, anti-fungus. The varnishis either applied via a Dip and Bake, orVacuum Pressure Impregnation (VPI)process. The combination of materialsand processes provides a minimumCorona Inception Voltage (CIV) up to1800 volts peak with a rise time of0.1 microseconds.

    GEGARD2000TMThis system exceeds NEMA MG1-31 (whichis 3.1 times the nameplate voltage) formotors operating on inverters. The insulationsystem is comprised of class H materials andthe varnish is non-hygroscopic, anti-fungus.The varnish is applied via a Trickle Treatprocess while a 60 Hz current is passedthrough the windings. This causes thevarnish to flow through the winding resultingin improved penetration into the stator slotsand an increase in varnish build. The currentalso cures the winding from the inside out,rather than oven baking. The combinationof materials and processes provides a

    minimum Corona Inception Voltage (CIV)up to 2000 volts peak with a rise timeof 0.1 microseconds.