Electrical Testing · Salt Spray Chamber Thermal Shock Chamber Climate Temperature System Humidity...
Transcript of Electrical Testing · Salt Spray Chamber Thermal Shock Chamber Climate Temperature System Humidity...
Electrical TestingISO 17025 (NABL Accredited)
Electrical Endurance Testing
1. a. PVC Insulated Cables(1100 V) Annealing Test(Cu) Upto 50 kN
IS:694-2010 (NABL Appd.) Tensile Test(Al) Upto 50 kN
Wrapping Test(Al) Visual
Conductor Resistance Test 11Ω
Test For Overall Dimensions 25 mm,200 mm
Ageing In oven (200°C,0-5 kN)
Shrinkage Tests (200 mm,Upto 200°C)
Hot Deformation Test Upto 200°C
Loss Of Mass In Air Oven (200°C,200g)
Heat Shock Tests Upto 200°C
Insulation Resistance Test Upto 100X 10 MΩ
High Voltage(Water Immersion Test) (10 kV A.C,100°C)
High Voltage(Water Immersion Test) (10 kV D.C,100°C)
b. Cross Linked Polyethylene Insulat -ed PVC Sheathed Cables: Part 1 Same As Above Same As above For Working Voltage And 1100V IS: 7098(P-1) 1988 (NABL Appd.)
c. Aluminum Conductors For Diameter Of Al Upto 25 mm Overhead Transmission Purposes Conductivity Resistence20°C 11 Ω IS :398 (P-2: 1996) (NABL Appd.) Breaking Load Upto 50 kN
Ductility Test 0- 50kNElongation 0- 500kNGalvanizing Test 0-200g
d. Aluminum Conductors For Stranding Visual Overhead Transmission Purposes Lay Ratio 0.5 mm IS: 398:1994 (NABL Appd.)
2. Water Purier Leakage Current Test 2000μA IS :14724-1999 (NABL Appd.) High Voltage Test 0- 5kV
Earthing Connection (50A ,20 V)3. Electric Iron Rating Visual IS:366-1991(NABL Appd.) Measurement Of Heating Time 400°C
Measurement Of Sole Plate 400°CProtection Against Shocks 0- 75 VPower Input And Current 5 kW
4. Electric Immersion water Heater Same As Above Same Ranges IS:368-1982 (NABL Appd.)
5. Switches (Domestic Purpose) Insulation Resistence Test Visual IS:3854:1997 (NABL Appd.) Resistence To Rusting Visual
Protection Against Shocks 0-75 V
6. Automobile/ Electronic Components Testing
Heat Resistance Test 30 to 250ºC JIS, JASSO, IEC-60068, Tata Cold Resistance Test -80 to 27ºC Standard, Maruti Standard Thermal Cycle Test -40 to 180ºC and IS:10250 Thermal Shock Test -80 to 180ºC
Damp Heat Test 99.9% R.H
Product Description &Applicable Standard
Test Performed Range
9
We provide complete testing of electrical and electronic products. This ensures customers are able to comply with the widest range of international standards and end user requirements.
Parameters
ASTM B117, ISO:9227, JIS:J2371, Salt Spray Test 5% NaCL
IS:5528 IS & IEC Standard Insulator Testing NFC Standard Piercing Connector Testing IS & NFC Standard Overhead Wire Fitting Testing IS Drop Out Fuse Testing IS Fuse Wire Testing
7. Power Generation & Distribution System Testing a. Current Transformers Testing Determination of Error 5A to 2000A IS:2705-1992, IEC:60044-1-2003 measurement of winding 1mΩ to 20 kΩ
ResistanceTemperature Rise test 2400A 0-200 Temp.High Voltage Power 3kV Frequency TestVerication of terminal –Marking and polarityAccuracy Limit Factor 30Composite Error Measurement 15%
b. Energy Meters Single Phase Energy Meter
Ω
IS:10250
240 V , 1-5 Amp
ICBIP-88 (Feb 2002), IS:13779:1999 Three Phase Energy Meter 5Wh to 100 kWh
IS:14697:1999, IEC:62052-11-2003
c. Breakers
d. Relays
IEC:60255-5 Insulation Resistance Test 100M
Humidity Test 99.9%
8. Energy Efciency & Performance
Testing
IS:15750 Frost Free Refrigerator Test
AS/NZS:4474.1 & AS/NZS 4474.2/ Direct Cool Refrigerator Testing
IS:1476
IEC 62301 Ed. 1.0 & IEC 62087 Colour Television Test
IS 14155 & IEC 60456 Washing Machine Test
IS 1391 Part 1 & Part 2 Air Conditioner Testing
IS 12615:201, IS 4029 -1967, Induction Motor Testing
IS 325:1996
IS 2418 (Part I), (Part II), (Part III) Tubular Fluorescent
& Part(IV) - 1977 Lamp Testing
IS 14220:1994, IS 8034 : 2002, Agricultural Pump Sets
IS 9079 : 2002, IS 11346: 2004
S 374 :1979 Ceiling Fans Test
IS 2082:1993; IS 302-2-21 Water Heaters/
Electric Geysers Test
IS 4246 : 2002 Liqueed Petroleum Gas Stoves
Product Description &Applicable Standard
Test Performed Range
9. Equipment Health Monitoring & Cables Services Turbines
TransformersGeneratorsMotors
10.Energy Audits We Perform On Site Audits for Energy.
Salt Spray Chamber Thermal Shock Chamber Climate Temperature System Humidity Chamber Oven Deep Freezer Million Megaohm meter Iron Temperature Setting Kelvin Double Bridge Conductivity Meter AC/DC High Voltage Tester Water Bath Multi Test Panel
Electrical Testing
List of Major Equipments
Product Description &Applicable Standard
Test Performed Range
E-41 Okhla Industrial Area Phase-IINew Delhi-110020Ph:- 91 11 40522000, 41611000E-mail: [email protected]:- www.spectrogroup.com www.spectro.in
Head Office Corporate office
S-1 GNEPIP, Surajpur Industrial AreaKasna, Greater Noida, Phase-V
Gautam Budha Nagar (U.P.)Pin Code: 201308
Ph:- 0120-2341251/52 E-mail:- [email protected]
URL:- www.spectrogroup.com2017
Major Ac�vi�es
Testing
Calibration
Training
Inspection
R&D
Automation
Reverse Engineering
Ü Metals & Alloys
Ü Non Destructive Testing
Ü Rubber & Polymers
Ü Food and Agro Products
Ü Coal, Solid Fuels & Petroleum
Ü Electrical & Electronics
Ü Pharmaceuticals & Drugs
Ü Building Materials
Ü Minerals & Chemicals
Ü Leather & Textiles
Ü Water & Environment
Ü Paper & Packaging Materials
Ü Hazardous Substances
Ü Clean Room Validation
CIN : U74220DL1998PL C092698