2009/10/23 CPHO/MIRDC 1 風力機性能與噪音量測簡介 報告人 : 區域研發服務處...

34
2009/10/23 CPHO/MIRDC 1 風風風風風風風風風風風風 風風風 : 風風風風風風風 風風風風風風風風風風 風 風 風

Transcript of 2009/10/23 CPHO/MIRDC 1 風力機性能與噪音量測簡介 報告人 : 區域研發服務處...

  • Slide 1
  • 2009/10/23 CPHO/MIRDC 1 :
  • Slide 2
  • Contents 2009/10/23 CPHO/MIRDC 2 u - Power performance measurements( IEC 61000-12-1) u - Noise level measurements (IEC 61000-4-11)
  • Slide 3
  • 2009/10/23 CPHO/MIRDC 3 Wind energy u Kinetic Energy = 0.5 x Mass x Velocity 2 Mass/sec (kg/s) = Velocity (m/s) x Area (m 2 ) x Density (kg/m 3 ) Power = 0.5 x Swept Area x Air Density x Velocity 3
  • Slide 4
  • 2009/10/23 CPHO/MIRDC 4
  • Slide 5
  • wind turbine class 2009/10/23 CPHO/MIRDC 5 Class of wind turbine: Small wind turbine : rotor sweep area < 200
  • Slide 6
  • Test standard of wind turbine uIEC 61400-1 (2007-03)3 u uIEC 61400-2 (2006-03)2 u uIEC 61400-11 (2006-11) 2.1 u uIEC 61400-12-1 (2005-12)2 u 2009/10/23 CPHO/MIRDC 6 IEC/TS 61400-13 (2001-06)1 IEC/TS 61400-14 (2005-03)1 IEC 61400-21 (2001-12)1 IEC/TS 61400-23 (2001-04)1 IEC/TR 61400-24 (2002-07)1
  • Slide 7
  • Power performance measurements 2009/10/23 CPHO/MIRDC 7
  • Slide 8
  • Wine turbine test site 2009/10/23 CPHO/MIRDC 8 Flat terrain Complex terrain
  • Slide 9
  • Test site requirements: topographical variations 2009/10/23 CPHO/MIRDC 9
  • Slide 10
  • Illustration of area to be assessed-1 2009/10/23 CPHO/MIRDC 10
  • Slide 11
  • Illustration of area to be assessed - 2 2009/10/23 CPHO/MIRDC 11 the sectors to exclude when: a) the meteorological mast is in the wake of the wind turbine under test; b) the meteorological mast is in the wake of the neighbouring and operating wind turbine; c) the wind turbine is in the wake of the neighbouring and operating wind turbine; d) the meteorological mast is in the wake of the significant obstacle; e) the wind turbine is in the wake of the significant obstacle; f) all of the above effects a) to e) are combined.
  • Slide 12
  • Find the right place for the met mast u None relevant obstacle u None neighbouring other u turbines u Flat area according to u the surrounding u Possibility of placement u of mast (e.g Permission of u the land owner, building u permission etc.) u Primary wind direction u Limit of the sector due to u the reference turbine 2009/10/23 CPHO/MIRDC 12
  • Slide 13
  • 2009/10/23 CPHO/MIRDC 13
  • Slide 14
  • Installation of Anemometer on the mast-1 2009/10/23 CPHO/MIRDC 14
  • Slide 15
  • Installation of Anemometer on the mast- 2 2009/10/23 CPHO/MIRDC 15
  • Slide 16
  • Selection of anemometer (A, B and S) u Class S specify the limit refer to the site S u Class A