TRG(TEIKOKU ROTARY GURDIAN)
Bearing Wearing Monitor for TEIKOKU CANNED MOTOR PUMP1
Principle (Sensor Location)
A-A Sectional
2
Principle
Basic Wave A
Groove Harmonics A
Compound Output A + BGroove Harmonics B
3
Principle
Bearing Worn Out a >b TRG Indication gets Big
a
b
4
Configuration & Option Sensor Coil Anti-Rotating Detection (Mold Circuit) TRG Meter (Flame-Proof) TRG Panel Meter (Option) TRG Alarm (Option) TRG Converter (Option)5
TRG Convertor TRG Signal is converted to 4-20(mA) or 1-5(V) which realizes centralized control. Flam Proof Explosion (d2G4) is available as option.
TRG Convertor Output20 18 16 (mA) 14 12 10 8 6 4 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 5 4.5 4 3.5 3
2 1.5 1
TRG Indication
6
(V)
2.5
TRG Function Bearing Wearing Out 2-Phase Connection Wrong 3-Phase Connection Anti-Rotate Eccentric Assembly Unbalanced 3-Phase Amperage Unbalanced Induced Amperage on Rotor Defects7
TRG Indication at Start Up (With Anit-Rotating Detection)Indication Full Scale Yellow Red Green Root Cause Anti-Rotate 2(1) Phase Connection Good Action Confirm Wire Assignment Confirm Wire Connection No
8
TRG Indication during RunningIndication Green Initial + 0.3 (Yellow) Initial + 0.5 (Red) Condition Safe Caution Danger Action No Ready to Maintain Stop Pump
Initial TRG Value should be Recorded9
TRG Singnal With Anti-Rotating Detection (TRG Model : M, R) Diode Commutation, 350mVDC to Full Scale Without Anti-Rotating Detection (TRG Model : L, G) Raw TRG Signal AC1V to Full Scale Frequency < 3kHz10
Wiring to Outer Divices, TRG-Panel Meter, Alarm, and Convertor Wiring : Single Core Shielded Signal Wire 1.25mm2 or BiggerCore to G1 Terminal, Shield to G2 Terminal
In case Double Core Wire is used,Core to G1 Terminal, Shield to G2 Terminal
Shield must NOT be Grounded Keep Away from Power Cable11
WiringPANNEL TERMINAL BOX TRG METER TRG PANNEL METER TRG ALARM
Shield must NOT be Grounded
12
Other factors to vary TRG Indication Over Loading Since TRG is sensing magnetic field generated by amperage on rotor, indication varies depending on loading. i.e. Flow Rate, SG, Viscosity, Ambient Temperature Devises in TRG meter is affected by temperature but indication varies no more than 0.1 scale. 13
, G1,G2 14
G1-G2 k / W
15
, , ) kHz k z 16
17
18