Internal Use Only
ADSL
add-vlan 99,3994vlan 99,3994 5/1 tag
ip subnet 10.23.6.36 255.255.255.0 3994ip route 0.0.0.0 0.0.0.0 10.23.6.1system hostname TNN.MHP.M11vlan 159 1/1-32 untag pvc 1port-location pppoe-plus enable
port-location flexible-syntax VNPT
[hostname] [iftype] [rack]/[frame]/[slot]/[port]:[vpi].[vci]vlan 2400 1/1 untag pvc 2ip igmp enable
ip iptv cac disableip igmp mvlan 99 ip igmp mode proxy
ip igmp span-vlan enable ip igmp mvlan 99 source-port 5/1 ip igmp mvlan 99 start-group-ip 232.84.1.1 254interface rang adsl 1/1-32 pvid 159 pvc 1
atm pvc 1 vpi 0 vci 32
adsl profile 10 pppoe-plus enable
port-location flex-format VNPT
interface adsl 1/1
atm pvc 2 vpi 1 vci 35 pvid 2400 pvc 2 igmp enable
igmp fast-leave enable multicast vlan 99 pvc 2 ip igmp mvlan 99 receive-port 1/1 pvc 2 adsl-profile 10adsl-profile 10AtucConfRateMode(1-fixed,2-adaptAtStartup,3-adaptAtRuntime):[2]
AtucConfRateChanRatio(0..100):[0]
AtucConfTargetSnrMgn(0..310(0.1dB)):[80]
AtucConfMaxSnrMgn(80..310(0.1dB)):[310]
AtucConfMinSnrMgn(0..80(0.1dB)):[0]
AtucConfDownshiftSnrMgn(0,0..80(0.1dB)):[0]
AtucConfUpshiftSnrMgn(0,80..310(0.1dB)):[0]
AtucConfMinUpshiftTime(0..16383):[0]
AtucConfMinDownshiftTime(0..16383):[0]
ConfProfileLineType(1-fast-only,2-interleaved-only):[2]
AtucChanConfFastMaxTxRate(0..102400kbps):[1024]4096
AtucChanConfFastMinTxRate(0..4096kbps):[32]
AtucChanConfInterleaveMaxTxRate(0..102400kbps):[1024]4096
AtucChanConfInterleaveMinTxRate(0..4096kbps):[32]
AtucChanConfMaxInterleaveDelay(0..255ms):[16]
AturConfRateMode(1-fixed,2-adaptAtStartup,3-adaptAtRuntime):[2]
AturConfRateChanRatio(0..100):[0]
AturConfTargetSnrMgn(0..310(0.1dB)):[80]
AturConfMaxSnrMgn(80..310(0.1dB)):[310]
AturConfMinSnrMgn(0..80(0.1dB)):[0]
AturConfDownshiftSnrMgn(0,0..80(0.1dB)):[0]
AturConfUpshiftSnrMgn(0,80..310(0.1dB)):[0]
AturConfMinUpshiftTime(0..16383):[0]
AturConfMinDownshiftTime(0..16383):[0]
AturChanConfFastMaxTxRate(0..10240kbps):[512]1024
AturChanConfFastMinTxRate(0..1024kbps):[32]
AturChanConfInterleaveMaxTxRate(0..10240kbps):[512]1024
AturChanConfInterleaveMinTxRate(0..1024kbps):[32]
AturChanConfMaxInterleaveDelay(0..255ms):[16]
AtucDMTConfFreqBinsOperType(1-open,2-cancel):[2]
AturDMTConfFreqBinsOperType(1-open,2-cancel):[2]
LineDMTConfEOC(1-byte ,2-streaming ):[1]
LineDMTConfTrellis(1-on,2-off):[1]
AtucConfMaxBitsPerBin(0..15):[15]
AtucConfTxStartBin(6..511):[32]
AtucConfTxEndBin(32..511):[511]
AtucConfRxStartBin(6..63):[6]
AtucConfRxEndBin(6..63):[31]
AtucConfUseCustomBins(1-on,2-off):[2]
AtucConfDnBitSwap(1-on,2-off):[2]
AtucConfUpBitSwap(1-on,2-off):[2]
AtucConfREADSL2Enable(1-on,2-off):[2]
AtucConfPsdMaskType(1-DMT_PSD_MSK,2-ADSL2_PSD_MSK,3-ADSL2_READSL_WIDE_PSD_MSK,4-
ADSL2_READSL_NARROW_PSD_MSK):[3]
AtucConfPMMode(1-DISABLE,2-L2_ENABLE,3-L3_ENABLE,4-L3_ENABLE | L2_ENABLE):[1]
AtucConfPML0Time(0..255s):[240]
AtucConfPML2Time(0..255s):[120]
AtucConfPML2ATPR(0..31db):[3]
AtucConfPML2Rate(512..1024kbps):[512]
Press M or m key to modify, or the other key to complete?[C]
WAN
Lan:10.23.159.64/28
172.32.0.178/30
172.32.0.177/30
add-vlan 631 // SVLAN 631
add-vlan 194 //CVLAN 194
vlan 631 5/1 tag vlan 631 1/1 untag pvc 1 vlan 194 1/1 untag pvc 1
interface adsl 1/1
svlan enable pvc 1
psvid 631 pvc 1
pvid 194 pvc 1
Ethernet
HSI CVLAN: 2
system hostname TNN.TEST.H11TNN.TEST.H11(config)#add-vlan 2
vlan 2 5/1-2 tagvlan 2 3/4 untag TNN.TEST.H11 (config)# interface ethernet 3/4TNN.TEST.H11 (cfg-if-eth-3/4)# pvid 2TNN.TEST.Z11(cfg-if-adsl-3/4)# igmp enable
TNN.TEST.Z11(cfg-if-adsl-3/4)# igmp fast-leave enablePAGE 3
All Rights reserved, No Spreading abroad without Permission of ZTE
Top Related