7/31/2019 Http Www.dgserve HPSV Fitt
1/18
15-NOV-1Download Date:Page 1 of 18
Sub: Rate Contract for supply of HPSV Fittings & Accessories
Validity: From 01-JAN-11 To 31-DEC-11 .
Ref:(1) This Office Tender Enquiry No. HPSV Fitt./ES-7/RC-A1030000/1211/37Opened on 09-DEC-10.
(2) Your Quotation No. RE/RC:HPSV FITT(T)/2010/880 And Dated
09-DEC-10.
Dear Sir,
You are hereby informed that your above refered tender read with subsequent letters mentioned above for the Stores
specified in the Schedules annexed has been accepted. This rate contract will be governed by the terms and conditions
brought in the Form no. DGS&D 1001 available from dgs&d sales counter on payment of Rs. 50/- .The Rate Contract
and the schedules annexed here to shall be the sole repository of this Rate Contract/Transaction.
SCHEDULES ANNEXED
1.Schedule "A" Description of stores,prices,duties/taxes.
2.Schedule "B" special conditions of contract / Other information.
3.Schedule "C" Information to DDOs about parallel rate contracts.
4.Annexure - Technical Specification
Yours Faithfully,
( )
Assistant Director(S)/Section Officer/Dy.Director
For and on behalf of the purchaser named in the Form DGS&D 1001.
Government of India
Directorate General of Supplies & Disposals
Jeevan Tara Building, 5 Sansad Marg
New Delhi-110001
Tel Number 23360610/23360537
Rate Contract no. HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432
Dated 03-JAN-11
Rate Contract
To,
RAJ ELECTRICALS
214, FUNCTIONAL INDUSTRIAL ESTATE, PATPARGANJ,
DELHI,
7/31/2019 Http Www.dgserve HPSV Fitt
2/18
15-NOV-1Download Date:Page 2 of 18
COPY TO:
1.The Chief Controller of Accounts,Department of commerce,New Delhi/
COA Mumbai/COA Kolkata,COA Chennai.
(Through authentication cell) This issues with the approval of competent authority.
2.Deputy Director General of Supplies & Disposals,Chennai -10 copies each
3.Deputy Director General of Supplies & Disposals,Kolkata -10 copies each4.Deputy Director General of Supplies & Disposals,Mumbai -10 copies each
5.Deputy Director General (QA),Kolkata -10 copies each
6.Deputy Director General (QA),Chennai -10 copies each
7.Deputy Director General (QA),Mumbai -10 copies each
8.Deputy Director General (QA),DGS&D -10 copies each
9.Inspection Authority ADG(QA) DGS&D New Delhi - 110001.
10.Quality assurance Officer Director (QA) Delhi Directorate/ Mumbai,Chennai/Kolkata.
11.Concurrent Audit
12.MIS Cell
13.Ledger clerk
14.O.L.Section15.All Direct Demanding Officers as per mailing list maintained by DGS&D.
( )
Assistant Director (S) / Section Officer / Deputy Director
FOR DIRECTOR GENERAL OF SUPPLIES & DISPOSALS
7/31/2019 Http Www.dgserve HPSV Fitt
3/18
15-NOV-1Download Date:Page 3 of 18
1.Rate Contract No.:-HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432
Dated 03-JAN-11 For the Supply of HPSV Fittings & Accessories
2.Advance Rate Contract No.:-
Dated
3.(a) Name and Full Address of the Firm :-
---------------------------------------------------------------------------------------------------------------------------------------------
Item Model Store Description Unit RateNo. No. (in
Rs.)
---------------------------------------------------------------------------------------------------------------------------------------------
Type: for 70 Watt Lamps
Type: for 150 Watt Lamps
Type: for 250 Watt Lamps
26.45
26.45
26.45
Spare Ignitors
Spare Ignitors
Spare Ignitors
SCHEDULE - A
NOS.
NOS.
NOS.
13
14
15
DELIGHT
DELIGHT
DELIGHT
Rs.
TWENTY-
SIX AND
PAISE
FORTY-
FIVE
ONLY
Rs.
TWENTY-
SIX AND
PAISE
FORTY-
FIVE
ONLY
RAJ ELECTRICALS
214, FUNCTIONAL INDUSTRIAL ESTATE,
PATPARGANJ,
DELHI,
DELHI - 110092
Tel. No. - 22143204/5/6
Fax - 22160513
Email - -
(b) Name and Full Address of Manufacturer :-
RAJ ELECTRICALS
214, FUNCTIONAL INDUSTRIAL ESTATE,
PATPARGANJ, DELHI
110092
(c) Brand: DELITE
4.Validity of Rate Contract: 01-JAN-11 To 31-DEC-11
5.Description of Item, Specification,Unit, Rate
7/31/2019 Http Www.dgserve HPSV Fitt
4/18
15-NOV-1Download Date:Page 4 of 18
Type: for 400 Watt Lamps
Type: for 70 Watt Tubular Lamps
Type: for 150 Watt Tubular Lamps
Type: for 250 Watt Tubular Lamps
Type: for 400 Watt Tubular Lamps
26.45
1469.79
2420
2648.25
2888.72
Spare Ignitors
Street Light Fittings with
IP-66 Protection
Street Light Fittings with
IP-66 Protection
Street Light Fittings with
IP-66 Protection
Street Light Fittings with
IP-66 Protection
NOS.
NOS.
NOS.
NOS.
NOS.
16
17
18
19
20
DELIGHT
DELIGHT
DELIGHT
DELIGHT
DELIGHT
Rs.
TWENTY-
SIX AND
PAISE
FORTY-
FIVE
ONLY
Rs.TWENTY-
SIX AND
PAISE
FORTY-
FIVE
ONLY
Rs. ONE
THOUSAN
D FOUR
HUNDREDSIXTY-
NINE AND
PAISE
SEVENTY-
NINE
ONLY
Rs. TWO
THOUSAN
D FOUR
HUNDREDTWENTY
ONLY
Rs. TWO
THOUSAN
D SIX
HUNDRED
FORTY-
EIGHT
AND
PAISETWENTY-
FIVE
ONLY
Rs. TWO
THOUSAN
D EIGHT
HUNDRED
EIGHTY-
7/31/2019 Http Www.dgserve HPSV Fitt
5/18
7/31/2019 Http Www.dgserve HPSV Fitt
6/18
15-NOV-1Download Date:Page 6 of 18
( )
Asstt. Director (S) / Section Officer / Dy. Director
For and behalf of the purchaser named in the Form DGS&D 1001.
All the R/C particulars including prices in respect of individual R/Cs are available on DGS&D website which can be
accessed by all.The DGS&D website is http://dgsnd.gov.in
23-Packing & Specification :
Supply order(s) in any other form placed on or after 01-10-2008 shall not be valid and shall not be acted upon by the
contractor or any other concerned agencies.
DDO shall download the supply order and send an ink signed copy to the concerned paying authority specified in the
rate contract through Registered / speed post immediately after on-line placement of Supply Order(s).
see annexure
7/31/2019 Http Www.dgserve HPSV Fitt
7/18
15-NOV-1Download Date:Page 7 of 18
SCHEDULE - B
RC Specification:1 70 Watt HPSV Class IP-66 Street Light Fittings
1.01 Over all Dimension of fitting (LXWXH)
(Tolerance -5%)
550mmX250mmX155mm
1.02 Bare weight of fitting in Kg (Min) 3.520 Kg
1.03 Type of gasket used and its specification Neoprene1.04 Total weight of fitting with fixture but without lamp 5.3 Kg.
1.05 Whether detail dimensional drawing depicting all
parts? and colour photograph available with tenderer Yes
1.06 Indicate the pattern of punch marking on flange of
ballast for unique identification of product.
R1
2 150 Watt HPSV Class IP-66 Street Light Fittings
2.01 Over all Dimension of fitting (LXWXH)
(Tolerance -5%)
630mmX280mmX160mm
2.02 Bare weight of fitting in Kg (Min) 4.630 Kg.
2.03 Type of gasket used and its specification Neoprene
2.04 Total weight of fitting with fixture but without lamp 7.32 Kg
2.05 Whether detail dimensional drawing depicting all
parts? and colour photograph available with tenderer
Yes
2.06 Indicate the pattern of punch marking on flange of
ballast for unique identification of product.
R1
3 250 Watt HPSV Class IP-66 Street Light Fittings
3.01 Over all Dimension of fitting (LXWXH)
(Tolerance -5%)
700mmX310mmX180mm3.02 Bare weight of fitting in Kg (Min) 5.340 Kg.
3.03 Type of gasket used and its specification Neoprene
3.04 Total weight of fitting with fixture but without lamp 9.25 Kg.
3.05 Whether detail dimensional drawing depicting all
parts? and colour photograph available with tenderer
Yes
3.06 Indicate the pattern of punch marking on flange of
ballast for unique identification of product.
R1
4 400 Watt HPSV Class IP-66 Street Light Fittings
4.01 Over all Dimension of fitting (LXWXH)(Tolerance -5%)
700mmX315mmX190mm
4.02 Bare weight of fitting in Kg (Min) 5.350 Kg.
4.03 Type of gasket used and its specification Neoprene
4.04 Total weight of fitting with fixture but without lamp 10.95 Kg.
4.05 Whether detail dimensional drawing depicting all
parts? and colour photograph available with tenderer
Yes
4.06 Indicate the pattern of punch marking on flange of
ballast for unique identification of product.
7/31/2019 Http Www.dgserve HPSV Fitt
8/18
15-NOV-1Download Date:Page 8 of 18
R1
7/31/2019 Http Www.dgserve HPSV Fitt
9/18
15-NOV-1Download Date:Page 9 of 18
1
2
3
4
5
6
7
8
HPSV Fitt./ES-7/RC-
A1030000/1211/37/03242/1430
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04512/1431
HPSV Fitt./ES-7/RC-A1030000/1211/37/05455/1442
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05454/1444
HPSV Fitt./ES-7/RC-
A1030000/1211/37/NA071/1438
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04739/1433
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05761/1427
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04681/1439
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
INDUSTRIAL KALINGA
LITON LIGHTING INDUSTRY
TWINKLE LUNINAIRES PVT LTD
TWINKLE INDUSTRIES
LORD KRISHNA ELECTRONIC INDUSTRIES
ELECTROCINE INDUSTRIES
COMMANDER ELECTRICALS
SATYA ENGINEERING WORKS PVT.
LIMITED
6/3&4,Katori Mill,Rajender NagarIndl.Area,G.T.Road
K.No. 22/6/1, Peepal Wali Gali, Gali No.9, Samaypur
Badli,
C-59, Preet Vihar, Vikas Marg, Delhi
C-59, Preet Vihar, Vikas Marg,
23-24 KRISHAN KUNJ, LAXMI NAGAR,
56/18, Site-IV, Indl Area, Sahibabad, Ghaziabad
D-14, 15, 114 & 115, Shreenath Industrial Estate,S. No. 197, B/H Voltas,
Dadra Check Post
A-111, Mangol Puri Indl. Area,
Phase-II,
Sahibabad
Delhi
Delhi
Delhi,
DELHI
Ghaziabad
Dadra
UTTAR PRADESH
DELHI
DELHI
DELHI
DELHI
UTTAR PRADESH
DADRA NAGAR HAVELI
201007
110042
110092
110092
110092
201010
396230
Sr.No. NAME & FULL ADDRESS OF FIRM R/C NO & DATE
SCHEDULE - C
List of Parallel Rate Contract For HPSV Fittings & Accessories
7/31/2019 Http Www.dgserve HPSV Fitt
10/18
15-NOV-1Download Date:Page 10 of 18
8
9
10
11
12
13
14
15
16
17
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04681/1439
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04793/1440
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05459/1436
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04297/1446
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05047/1441
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04432/1443
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05807/1432
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05601/1445
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05204/1437
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05758/1428
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
FLORIDA ELECTRICAL INDUSTRIES LTD.
JAIN INDUSTRIAL LIGHTINGS CORP.
ARUN ELECTRICALS
SUNEET APROTECH (P) LTD.,
ELTON ELECTRICALS PRIVATE LIMITED
RAJ ELECTRICALS
ATLAS INDUSTRIES
MAMTA PRODUCTS
LUXOLITE INDUSTRIES
B-147, Maya Puri Industrial Area, Phase-1
B-70/22, DSIDC Industrial Complex, Lawrence
Road,
1/5, Khandsa Road, Gurgaon-122001
2094/1, Gali No. 17, Prem Nagar,
1759, Modern Industrial Estate, Bahadurgarh,
214, FUNCTIONAL INDUSTRIAL ESTATE,
PATPARGANJ,
71, S.S.I. Laghu Udyog Nagar, G.T. Karnal Road,
D-26, DSIDC Shed, Jhilmil Colony, Shahdara
A-2/25, Site-IV, Sahibabad Indl. Area, Distt.
Ghaziabad, U.P.
New Delhi
New Delhi
Delhi-110035
Gurgaon
New Delhi
Bahadurgarh
DELHI,
Delhi,
Delhi,
DELHI
DELHI
DELHI
HARYANA
DELHI
HARYANA
DELHI
DELHI
DELHI
110034
110064
110035
122001
110008
124507
110092
110033
110095
7/31/2019 Http Www.dgserve HPSV Fitt
11/18
15-NOV-1Download Date:Page 11 of 18
17
18
19
20
21
22
23
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05758/1428
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04782/1429
HPSV Fitt./ES-7/RC-
A1030000/1211/37/04842/1434
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05460/1447
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05461/1435
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05680/1448
HPSV Fitt./ES-7/RC-
A1030000/1211/37/05796/1450
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
03-JAN-11
SINGHANIYA LITE & LUMINARIUES (P)
LTD.
KUKREJA ENGINEERS
MODERN LIGHTING SYSTEMS
KOHLI & COMPANY
ULTRA LIGHTING LTD.
TANEJA SALES CORPORATION
12/4, Ist Floor, Subhash Nagar
H-1201, D.S.I.D.C. Narela Industrial Area, Narela
Unit No.64, Block B-70, Dr.
Lohia Industrial Area,
Lawrence Road,
T-5, Okhla Indl. Area, Phase-II,
A-83, G.T. Karnal Road, Industrial Area, Azadpur,
A-83, G.T. Karnal Road, Industrial Area, Azadpur,
GHAZIABAD
New Delhi
Delhi
Delhi
New Delhi
Delhi,
Delhi,
UTTAR PRADESH
DELHI
DELHI
DELHI
DELHI
DELHI
DELHI
201010
110027
110040
110032
110020
110033
110033
NOTE:
(1) Before placing supply order, DDOs are advised to check with DGS&D or on the website whether any further RCs
have been awarded or amendments to Rate Contract have been issued.
(2) All the R/C particulars including prices in respect of individual R/C's are available on DGS&D website,which can be
accessed by all. The access code of DGS&D website is http://dgsnd.gov.in.
7/31/2019 Http Www.dgserve HPSV Fitt
12/18
15-NOV-1Download Date:Page 12 of 18
1. FITTINGS:
The fittings where specified shall be ISI marked to IS: 10322 (Part 5/Sec
3)-1987(Reaffirmed 2005) (Incorporating Amendment Nos. 1, 2, 3 & 4)
,IS:10322(Part5/Secl)-1985(Reaffirmed 2005)(Incorporating Amendment Nos. 1,& 2),IS
13383 (Part 2) : 1992( Reaffirmed 2000 ) (Incorporating Amendment No. 1) (for
photometric) as applicable and with the following additional requirements. Street
Light Fittings shall have photometric efficiency of 65%. Connecting wire from
control gear terminal block to lamp holder shall be of 1.1 KV grade, copper
conductor XLPE insulated.
2. BALLAST:-
Ballast shall generally conform to IS : 6616-1982( Reaffirmed 2006) with the
following variations:-
a)At rated voltage power delivered shall not be less than 92.5% and
not more than 107.5% of the power delivered by the reference ballast.
b)Between 92% and 106% rated voltage, the short circuit current shall be within
limits given in IS : 9974 (Part I)-1981(Reaffirmed 2002) (Incorporating Amendment
Nos. 1, 2, 3 & 4)under the heading ballast design information.
c)Abnormal operation (type test)is to be carried out in association with
ignitor
and as per ignitor specification and for each ratings.( Firm shall declare the
model
and manufacturer of ignitor for which their ballast is suitable)
d)High voltage test of 5 KV for one minute as a type test and 5 KV for 5
seconds as an acceptance test.
NOTE: Firm shall have to use their own make ballst for manufacturing of HPSV
fittings
3.IGNITOR:
I. Performance requirements between 92% & 106% of rated voltage.
(a)Pulse height,
(i) 1.8 KV to 2.3 KV-70W HPSV fitting
(ii) 2.8 KV to 4.5 KV-150W & above HPSV fittings.
(b)Direction & postion not material for the time being .
(c)Rise time 2 micro. secs. ( Maximum)
(d)Duration 0.9 to 8 micro. sec.
(e)Pulse repetition rate: 1 per cycle ref IS: 9974.
(f)Subsequent pulse height less than 70%.
II. Ignitor shall not pulsate after the lamp has been fully ignited i.e.current
though it shall be steady.III. Ignitors wrongly connected shall have not deliterious(adverse)effect on the
luminaire.
I.TYPE TESTING:.
A. FOR FITTINGS:- Additional requirements of type tests.
a) Temp. rise and voltage increase as per Clause IS : 9974 (Part I)-1981
(Reaffirmed 2002) (Incorporating Amendment Nos. 1, 2, 3 & 4).IS:9974 pt-II
should also be referred as applicable.
b) High voltage test of 5 KV for 1 Min with all terminals shorted and
ANNEXURE
7/31/2019 Http Www.dgserve HPSV Fitt
13/18
15-NOV-1Download Date:Page 13 of 18
capacitor
removed between terminal wire and earthing.
c) High Voltage test of 5 KV for1 Min. between two terminals of lamp and lamp
cap
(on lamp holders).
B. FOR BALLAST.
As per IS : 6616-1982( Reaffirmed 2006 ) and specification for ballast with
following additional requirements.
a) Abnormal operation(Type Test)is to be carried out in association with
ignitor and as per ignitors specification and for each rating. Firm shall declare
the model and manufacturer of ignitor for which their ballast is suitable.
b) High Voltage test of 5 KV for one Min. as a type test.
C. FOR IGNITORS.
i) Protection against accidental contact. The tests shall be conducted with
ballasts of makes offered by the firm in the luminaires/as spares.
ii) Moisture resistance, insulation resistance and electric strength (5KV for 1
Min.)The test will be conducted in accordance of IS : 6616 - 1982( Reaffirmed 2006
)
iii) Fault condition.
When starting device is operated under fault condition like shorting of
its terminal of lamp terminals, there shall be no emission of flame etc.& no
accessible
part will become live.
iv) HEATING TEST;
Heat test under normal conditions of operation with lamp at rated voltage
&
in abnormal condition without lamp at 110% voltage the components shall not
exceed
the permissible limits of operating temp. After these test and cooling down, the
ignitor shall operate normally.
v) Performance test for pulse characteristics.
Pulse characteristic measured with an appropriate osciloscope with ballast
& length of wire as provided by the manufacturer in the fitting upto the lamp
terminals.
vi) Creepage distance.
Test will be conducted in accordance of IS : 6616-1982( Reaffirmed 2001 ).
vii) Endurance
In this test two ignitors are connected as in normal use associated with an
appropriate ballast.The test voltage shall correspond to 1.06 x the rated supply
voltage of the ballast. The ignitors are operated in conformity with their
marking at the maximum allowable temp. in the fittings and without lamp.
In doing so the connections of one of ignitors are loaded by the maximum
allowable load capacitance say 1000 or unless otherwise specified while the
connections of the other ignitors are left unloaded.After 30 days of continuous
test they shall meet the requirement and ignite the lamp.
ACCEPTANCE TEST:
A FOR FITTING:-
a. High voltage test of 2.5KV for one minute with all terminals shorted and
capacitors removed between terminals wire and earthing. High Voltage of 2.5 KV
for one minute between two terminals of lamp cap ( on lamp holders).
7/31/2019 Http Www.dgserve HPSV Fitt
14/18
15-NOV-1Download Date:Page 14 of 18
b. Acceptance test as per governing specification.
B. FOR BALLAST.
In addition to tests referred in the specification the following tests are to be
conducted.
a. Performance test with lamp, ignitor and ballast.
b. Watt loss and cold resistance on random samples drawn as per sampling plan for
acceptance tests specified in in IS:6616 .however Sample size would be double of
that specified in IS:6616. The value of watt loss at nominal rated current
circulating directly and measured by a watt meter of 0.2 pf at an ambient
Temperature of 27 degree C shall conform to the following:
i) Watt loss shall not exceed the figures as under:-
For 70 Watts Lamp ballast - 15 Watts maximum
For 150 Watts Lamp ballast - 19 Watts maximum
For 250 Watts Lamp ballast - 26 Watts maximum
For 400 Watts Lamp ballast - 38 Watts maximum
ii) Resistance tolerance + 5% to -10% (Tenderers to declare the nominal cold
resistance value of winding in their offer).
iii) For energy efficient ballasts samples size for acceptance tests shall be
double the number of samples as indicated in IS:6616 and tests for limitation of
ballast heating will be conducted an acceptance test on each lot, each ballast
will be marked with watt loss and S.No. of the ballast.
C) FOR IGNITORS.
i) To be carried out on 4 samples out of every lot of 1000 Nos. and all sample
shall pass.
ii) Measurement of pulse height, duration, rise time, pulse rate etc. with the
ballast offered.
iii)High voltage test at 5 KV for 5 seconds.
D) Condensor shall conform to IS : 1569 /1976 (Reaffirmed 2001) (Incorporating
Amendment No. 1) and shall be suitable to give a power factor of 0.85 (minimum)
E) Lamp holders shall conform to IS: 10276 / 1982(Part I & II) (Reaffirmed 2003).
1. Suppliers shall furnish complete and satisfactory type test certificate as per
T/E specification for each item to the concerned DQA at the time of registration &
inspection.TTC shall be from any Government laboratory.
2. Lamps shall not be the part of supply.
QA PROCEDURE:
The following procedure are incorporated to augment the inspection process:
1. The firms shall furnish detailed drawing along with bill of material of each
rating/ variety of HPSV fittings for which they have been awarded DGS&D rate
contract. These drawings should also indicate average weight of the fittings (with
manufacturing tolerance) and should be in consonance with drawings/ sketches
vetted by Lab at the time of type testing .
2. Firms shall declare the source of aluminum die cast body, toughened glass,
aluminum reflector and neoprene rubber gasket and make/ model/ rating of bought
out electrical components being used in manufacturing/assembly of HPSV fittings.
They should also maintain record and proof of periodical testing of critical
7/31/2019 Http Www.dgserve HPSV Fitt
15/18
15-NOV-1Download Date:Page 15 of 18
components. .
3. Firms shall also declare the weight of the finished copper wound ballast,
weight of the stamping and its type/ grade, size of winding wire, weight of copper
winding wire and cold resistance of winding wire at 20 degree C (all with
tolerances) for each rating of HPSV ballast. Value of resistance may be converted
as per engineering practice at any required temprature.
4. For re-traceability purpose unique identification mark of the firm and serial
number/ lot number shall also be punched on the flange of ballast. In case a firm
prefers to punch the lot number, the same should not be repeated for the lot
offered for next inspection/ future.
5. Firms shall also keep QA office informed as to when die cast bodies are
received by them and ready for painting so that QA officer may be able to verify
the process on periodical basis and ensure the quality of casting as per
specification.
6. Dimension of fitting shall be as per indicative value given in specification
of TP. .Fresh TTC is not required for mere change in dimension / size if
fittings being tendered/offered are having greater size in comparison to
sizes indicated in sketch of type tested products of different ratings which has
been authenticated by lab. How ever if sizes of type tested fittings are more
than required value , firms have to offer products accordingly and they are not
allowed to reduce sizes.
7. During inspection the QA officers shall also verify the offered stores for
their conformance with the declaration made by the firm.
The overall dimensions (LxWxH) & weight of the fittings, weight and cold
resistance of ballast winding at 20 0C, punched unique identification mark of the
firm & lot number and serial numbers of ballasts shall be recorded in the I/notes
for the guidance of the consignees with the explicit remark that the stores may be
checked for these parameters and deviations if any should be reported for
appropriate corrective and preventive action .
8. Samples of items tested out of the lot offered for first inspection are to be
retained by firm with detailed identification ( R/C no, rating, date of
inspection, TTC no etc) for comparison during subsequent inspection. Retention
period of sample should not be less than 24 months since dispatch of last
consignment to user against this R/C.
Spare Ignitors
Street Light Fittings with IP-66 Protection
Specification :
Spare Ignitors for luminaires against schedule -66 i.e. IP-66
class (make & type) to be specified and to be supported with test reports. Also
refer to GTR
Specification :
Street Light Luminaires, IP-66 Class ISI marked to IS : 10322
7/31/2019 Http Www.dgserve HPSV Fitt
16/18
7/31/2019 Http Www.dgserve HPSV Fitt
17/18
15-NOV-1Download Date:Page 17 of 18
of
IS 10322 ( Part I ) : 1982( Reaffirmed 2005 ). Fittings shall have photometric
efficiency of 65%.
vii.) Dimension of fittings i.e. Length x Width x Height for respective rating
should be as under with maximum permissible minus tollerace on dimension of 5%:
70 Watt: 550x250x150
150 Watt: 630x280x160
250 Watt: 690x310x180
400 Watt: 700x315x190
All dimension are in mm and without any restriction on upper limit on dimension.
It may be noted that above dimensions are given for homogenity however once
dimension declared by firm as per their manufacturing drawing allowable
manufacturing tollerance in negative side shall not be more than 5mm which may
arise due to shrinkage etc.
Drawing/Proforma/Annexure Attached [Click on the following to View/Print ]
Inspection Report Performa
https://www.dgserver.dgsnd.gov.in/IR_HPSVFITTING.pdfhttps://www.dgserver.dgsnd.gov.in/IR_HPSVFITTING.pdf7/31/2019 Http Www.dgserve HPSV Fitt
18/18
LIST OF ALL AMENDMENTS
For RC No. HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432
Sr No. Amendment No. Amendment
Date
Effective
From
HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432/343611 04-JAN-11 03-JAN-11
Amendment In
Amendment in E
Duty,Annexure &
Clauses
http://www.dgserver.dgsnd.gov.in/formseal/server/custompdfsigner.jsp?TID=HPSV%20Fitt./ES-7/RC-A1030000/1211/37/05807/1432/34361/04-JAN-11&FORMNAME=RCAMEND&URL=/reports/rwservlet?KEY1&report=rcamendAPPROVpdf.rdf&destype=cache&desformat=pdf&PRCNO=HPSV%20Fitt./ES-7/RC-A1030000/1211/37/05807/1432&LETNO=nil&PFILE=04A10300001211&DKDATE=04-01-2011&LETDATE=http://www.dgserver.dgsnd.gov.in/formseal/server/custompdfsigner.jsp?TID=HPSV%20Fitt./ES-7/RC-A1030000/1211/37/05807/1432/34361/04-JAN-11&FORMNAME=RCAMEND&URL=/reports/rwservlet?KEY1&report=rcamendAPPROVpdf.rdf&destype=cache&desformat=pdf&PRCNO=HPSV%20Fitt./ES-7/RC-A1030000/1211/37/05807/1432&LETNO=nil&PFILE=04A10300001211&DKDATE=04-01-2011&LETDATE=Top Related