Three-phaseUPS DELPHYSMP
from 60 to 200 kVAyour protection up to 1 200 kVA
There are two versions to meetyour requirements:
DELPHYSMP with an SCR rectifier,
DELPHYSMP elitewith an IGBT rectifierfor a sinusoidal current intput.
High quality power supply
Delivered by SVM digital modulation(Space Vector Modulation).
Adapted to supplying new IT loads with aleading power factor up to 0.9.
With sinusoidal voltage for non-linear loads(Crest Factor 3:1).
High availabilityA fault tolerant architecture with redundancy
of basic functions, such as the ventilationsystem.
A variety of architectures for paralleloperations, to deal with redundancy,management and changes in poweroutput.
Easily integrated equipment
An IGBT rectifier which virtually eliminatesharmonic distortion, thus removing anystress on your power supply network.
Reduced current consumption due to an
input power factor of: 0.99.
The ideal solution for grouping withgenerator sets without using an excessivelylarge generator.
Battery availability at all timesAn innovative load algorithm which adapts
to the environmental conditions and thecondition of the battery to increase its life.
A highly-developed monitoring system,capable of locating and correcting anyproblems interacting with the chargingdevice.
Cost effective equipment
A compact unit for a smaller footprint.
An IGBT rectifier, which reduces the need toinvest in infrastructure (generator anddistribution).
The ENERGY SAVER function, in parallelmode, to optimise efficiency and operatingcosts.
User-friendly operation
A control panel with graphic display formore ergonomic operation.
An array of com-slot plug-in communicationinterfaces, for upgrading your operatingrequirements.
Simplified maintenance
An advanced diagnostic system.
A remote access device connected to theremote maintenance centre.
Easy access to subassemblies andcomponents, facilitating tests and reducingmaintenance time (MTTR).
> Data centre> Industry
> Telecommunications> Processes
Your protectionfor
DEFYS
121A
1CAT
8/3/2019 delMP
2/4
49
Three-phaseUPS DELPHYSMP
from 60 to 200 kVA
The SVM digital modulation SVM (Space Vector Modulation) fitted to the transformer
integrated downstream of the inverter allowssupply to your installations with:
precise voltage even when the loadbetween phases is completely unbalanced,
stable output voltage during significant andquick variations in loads ( 2 % in less than5 ms),
sinusoidal THDV output voltage < 2% withlinear loads and < 3% with non-linearloads,
active power without de-rating, with loadswith a lagging power factor and up to 0.9
leading, a high short-circuit capacity, up to 4 In,
which facilitates the selection of protectivedevices for selectivity in the downstreamdistribution,
secure galvanic isolation between the DCbus and supplied units.
High quality power adapted to new IT loads
Guaranteed available back-up time
DELPHYSMP eliteeasy to integrate into your electrical networkA clean IGBT rectifier
It eliminates any disturbance on theupstream network (source and distribution).
The cutting rectifier guarantees the supplyof current with an exceptionally low rate ofharmonic distortion: THDI < 2.5%.
A consistent rectifier
The performance of the IGBT rectifier isindependent of frequency variations thatcould be produced by the generating set.
The power factor and THDI at the rectifierinput are constant whatever the batterycharge status (continuous voltage level)and the load rate of the UPS.
[Info. p. 91]
An economical IGBT rectifier
The power factor upstream of the rectifier:0.99 lagging, reducing the kVA used by30% when compared with conventionaltechnology. The reduction in input currentresults in a saving in terms of the scale ofsources, cables and protective devices.
Rectifier capabilities:
- low upstream THDI,- gradual, timed restarting,- possibility of suspending battery rechargewhen operating with a generator set, allowthe impact caused when the generator set isengaged and the energy used to be reduced,along with the footprint.
EBS technology (Expert Battery System)
This exclusive feature prolongs battery life.
It carries out the charge according to analgorithm which adapts to the environmentalconditions and the condition of the battery.
It reduces corrosion and drying out of theseparators often caused by permanentfloating loads.
It reduces the residual ripple of the current,one of the causes of premature battery wear.
BHC Technology (Battery Health Check)
Guaranteed battery availability:
the battery and DC circuit are regularlyautomatically tested and the operator isnotified of their condition,
the optional BHC function tests andanalyses the following parameters: currentby branch, voltage by segment or block. Incase of drift, the interactive systemautomatically takes corrective charging
measures. If the drift continues, an alarmwith the location of the failure (branch,segment or block) allows the necessarypreventive repairs to be made.
DEFYS
127A
1CAT
DEFYS
036A
2CAT
DEFYS
091B
GB
100%kva
100%
kVA
cosos0,60,6cosos0,70,7cosos0,80,8 cosos0,80,8cosos 0,90,9cosos0,90,9
0,25,25
0,50,50
0,75,751 cosos
11100% kW00% kW
kWW
Without deratingithout derating
-1 -0,8 -0,6 -0,4 -0,2 0 0,2 0,4 0,6 0,8 1
cos0,6
cos0,7cos0,8
cos0,8cos 0,9cos0,9
0,25
0,50
0,75
1cos 1100% kW
kVAr
kW
Without derating
LEADINGEADING LAGGINGAGGINGLEADING LAGGING
8/3/2019 delMP
3/4
50
Parallel systems
IT-SWITCH
LTM 1
LTM 2
Load 1
Load 2
Load 3
DELPHYS
MPelite
DELPHYS
MPelite
ACS
ACS
In order to meet the most demandingavailability requirements, and the need for
the installation to be flexible andupgradable, up to 6 DELPHYSMP can runin parallel.
DELPHYSMP modular,
development without constraint.
DELPHYSMP centralised bypass,
progressive development.
DELPHYSMP redundant bypass,
yet more availability.
DELPHYSMP double bypass,
to simplify operation.
DELPHYSMPmulti bypass,
to separate application types.
DELPHYSMP a twin channel architecturewith Static Transfer Systems: LTM andIT SWITCH[Info. p. 66 and 70].
DEFYS
093A
DEFYS
094A
DEFYS
065A
DEFYS
059B
DEFYS
026A
DEFYS128A
GB
Three-phaseUPS DELPHYSMP
from 60 to 200 kVA
Standard equipment
Slots for 7 communication boards.
Protection backfeed: detection circuit.
Standard interface:- 3 inputs (emergency stop, generating set,
battery protection),- 4 outputs (general alarm, back-up, bypass,
preventive maintenance needs).
Accessories
BHC battery unit monitoring.
EBS (Expert Battery System)[Info. p. 99].
Colour touch screen.
ACS function for synchronisation with anexternal source[Info. p. 68 and 72].
Reinforced IP protection degree.
Ventilation filters.
Ventilation control.
Communication options
Remote control panel.
ADC (Advanced Dry Contacts) data inputand output by dry contacts[Info. p. 98].
RS232, RS422, RS 485 serial portJBUS/MODBUS or PROFIBUS protocol[Info. p. 98].
NET VISIONinterface for the LAN Ethernetnetwork[Info. p. 87].
TOP VISIONsoftware for supervision withWindowsTM [Info. p. 89].
Remote maintenance
e.SERVICE for continuous monitoring theSOCOMEC SICON UPS maintenanceservice.
[Info. p. 100]
Preventive maintenancerequest
Access to installation mimicpanel
UPS load rate(bar graph)
Help menu forcorrect operation
DEFYS
111A
GB
Graphic display
Design adapted to the user: control panel with LEDs and LCD display.
Colour touch screen
The operator has access to the control functions with only a few intuitive touches of the screen.
Quick access to eachinstallation module
Direct access zonesto sub-unit menus
Status bar
DEFYS
102A
Operating modeicons
8/3/2019 delMP
4/4
51
Three-phaseUPS DELPHYSMP
from 60 to 200 kVA
Automatic
Bypass
Maintenance
Bypass
Rectifier Inverter
Battery
Q4
Q5
Q3
Q20
Bypass cabinet
The coupling and centralised bypass functions.
On line double conversion[Info. p. 91]
1930
800W
60 800 280
80 800 280
120 800 280
200 800 300
250 800 300
300 800 320
400 800 320
500 800 330
800 1000 420
1200 1300 600
DEFYS
125A
GB
Technical data
RECTIFIER INPUT
TechnologyDELPHYSMP SCRDELPHYSMP elite PFC - IGBT
Voltage three-phase 380 V - 400 V - 415 V (1)
Acceptable tolerance 340 to 460 V
Frequency 50 - 60 Hz (45 to 65 Hz)
Power factor: DELPHYSMP elite 0.99
Distortion rate: DELPHYSMP elite THDI: 2.5%
OUTPUT
Voltage (configurable) three-phase + N 380 V - 400 V - 415 V (1)
Voltage toleranceStatic load < 1%Dynamic load conditions from 0 to 100% 2 % in 5 ms
Voltage distortion rate THDU < 2%
Acceptable crest factor without de-rating 3:1
PF acceptable without de-rating lagging to 0.9 lead.
Frequency (configurable) 50 - 60 Hz
Autonomous frequency tolerance 0.2%
Overload 1 min: 150%10 min: 125%
EfficiencyGlobal (2) up to 93.5%In ECO-MODEconfiguration 98%
ENVIRONMENT
Noise level (ISO 3746)(2) 68 dBA
Compliance to standardsSafety IEC62040-1-2/IEC60950EMC IEC62040-2Technical data IEC62040-3
Classification as per IEC62040-3 UPS VFI (3) - SS - 111
(1) Three-phase 220-230-240V on demand. - (2) As per power range. - (3) Voltage Frequency Independent.
DEFYS
124B
GB
UPS and batteries
A compact and integrated system.
DEFYS
126A
F
60/48 640 680 800 800 800 1000
80/64 660 700 800 1000 800 1300
100 / 80 790 820 800 1300 800 1700
120 / 96 810 840 800 1700 1600 1900
160 / 128 920 970 1600 1900 1600 2500
200 / 160 950 1000 1600 2500 2400 3000
1930
800A*
B
* DELPHYSMP A = 800 mm
DELPHYSMP elite A = 1000mm
Bypass transformer
For galvanic isolation.
1930
800W
60 600 400
80 600 450
120 600 550
200 800 850
300 1000 1250
400 1200 1500
DEFYS
087A
GB
(1) For other power ranges, please consult us.
UPS DELPHYSMP DELPHYSMP Battery for back-up timeelite 10 minutes 15 minutes
UPS power Weight Weight B Weight B Weight
kVA/kW kg kg mm kg mm kg
Power(1) W Weight
kVA mm kg
Power(1) W Weight
kVA mm kg