MANUALE TECNICO
INDICE
1. MODIFICHE TECNICHE 22. NOMENCLATURA E FUNZIONI DELLE PARTI 43. SPECIFICHE 84. LIVELLI SONORI 115. DISEGNI DIMENSIONALI 136. SCHEMI ELETTRICI 157. SCHEMI FRIGORIFERI 188. PRESTAZIONI 229. FUNZIONI DI SERVIZIO 33
10. DIAGNOSI DELLE ANOMALIE 3611. PROCEDURA DI DISASSIEMAGGIO 5512. ELENCO DEI COMPONENTI 6113. OPTIONAL DISPONIBILI 69
···································
Modelli con Telecomandoa Raggi Infrarossi
MSH-GA50VB - (WH) - MUH-GA50VB-E1
MSH-GA60VB - (WH) - MUH-GA60VB-E1
MSH-GA80VB - (WH) - MUH-GA80VB-E1E1
E1
E1
I-OB367/368
CLIMATIZZATORI SPLIT A POMPA DI CALORE
MSH-GA50VB -MSH-GA60VB -MSH-GA80VB - E1
E1
E1
Indicazione del modello
HFCutilized
R410A
MUH-GA50VB - E1
Indicazione del modello
····································································································
··········································································
························································································
···························································
·········································
·································
1
MSH-A18WV - ➔MSH-GA50VB -
MSH-A24WV - ➔MSH-GA60VB -
MSH-A30WV - ➔MSH-GA80VB -1. E’ stata rimosso la denominazione dei modelli.
E’ stata modificata l’indicazione della potenzialità nominale (da BTU a kW).2. E’ stato modificata la sagoma della griglia.3. Sono state modificate le dimensioni (da 1100 mm (L) x 325 mm (H) x 227 mm (P) a 1100 mm (L) x 325 mm (H) x 258 mm (P)).
E1E1
E1E1
E1E1
MUH-A18WV - ➔MUH-GA50VB -1. E’ stato abolito il separatore dell’olio.2. E’ stata modificata la denominazione dei modelli.
E’ stata modificata l’indicazione della potenzialità nominale (da BTU a kW).
MUH-A24WV - ➔MUH-GA60VB -MUH-A30WV - ➔MUH-GA80VB -1. E’ stata modificata la denominazione dei modelli.
E’ stata modificata l’ indicazione della potenzialità nominale (da BTU a kW).
E1E1
E1E1
E1E1
Olio
Ref
riger
ante
R410A
HFC-32: HFC-125 (50%:50%)
Pseudo azeotropico
Assente
A1/A1
72.6
-51.4
1.557
64
Incombustibile
0
1730
A liquido
Possibili
Nessuno
Nessuno
R22
R22 (100%)
Monocomponente
Presente
A1
86.5
-40.8
0.94
44.4
Incombustibile
0.055
1700
A gas
Possibili
Giallo chiaro
Nessuno
Refrigerante
Composizione Ponderale (%)
Comportamento
Cloro
Gruppo di sicurezza ASHRAE
Peso molecolare
Punto di ebollizione (°C)
Tensione di vapore (MPa a 25 °C)
Densità del vapore saturo (kg/m3 a 25 °C)
Infiammabilità
Potenziale ozonodeplettivo (ODP) w1
Potenziale di riscaldamento planetario (GWP) w2
Metodo di carica
Rabbocchi della carica
Colore
Odore
w1 ODP: Il valore indicato è espresso tenendo come riferimento quello dell’R11.w2 GWP: Il valore indicato è espresso tenendo come riferimento quello del CO2.
INFORMAZIONI SUI CLIMATIZZATORI FUNZIONANTI CON REFRIGERANTE R410A• Questi climatizzatori utilizzano il refrigerante R410A che, appartenendo alla famiglia degli HFC, non danneggia in alcun modo
lo strato atmosferico di ozono.• Tenendo presenti i punti qui di seguito evidenziati si può ritenere che le procedure fondamentali di installazione degli apparecchi
funzionanti ad R410A siano le stesse di quelle che venivano di norma poste in atto per gli apparecchi funzionanti ad R22.1 Poiché a parità di temperatura la pressione dell’R410A è pari a circa 1,6 quella che caratterizza l’R22, i climatizzatori funzionanti
con R410A devono essere installati e manutenzionati con materiali ed attrezzature specificatamente concepiti per R410A equindi più robusti in modo da reggere le pressioni in gioco con questo refrigerante (vedere la tabella che segue).
2 Poiché l’R410A è più sensibile alle contaminazioni dell’R22 durante l’immagazzinaggio e l’installazione è indispensabile impedireogni contatto tra refrigerante ed umidità in qualsiasi forma.
3 Per la realizzazione delle linee frigorifere usare solo tubazioni e componenti nuovi e specificatamente studiati per l’R410A(vedere quanto specificato in merito alla realizzazione delle linee frigorifere).
4 Poiché l’R410A è in realtà una miscela tra refrigeranti diversi, per impedire alterazioni della sua composizione è necessarioche esso venga caricato in fase liquida.
MODIFICHE TECNICHE1
2
NOTA : In ossequio alle normative internazionali la pressione deve essere espressa in MPa anziché in kgf/cm2.La trasformazione dei valori deve essere eseguita tenendo presente che : 1 MPa = 10,2 kgf/cm2.
Nuove caratteristiche Vecchie caratteristiche
L’olio che è incompatibile con il refrigerante si separa facilmenteda quest’ultimo e si deposita nella parte superiore del silenziatoredell’aspirazione. La posizione elevata del foro di ritorno dell’olioconsente il ritorno dell’olio stesso che si è depositato nella partesuperiore del silenziatore.
Poiché l’olio che è compatibile con il refrigerante si miscela conesso, il suo ritorno al compressore è possibile tramite il foro diritorno che si trova nella parte inferiore del silenziatore.
Compressore
Silenziatore
Foro di ritorno olio
Olio
Refrigerante
Compressore
Silenziatore
Foro di ritorno olio
Olio/Refrigerante
Rito
rno
dell’
olio
-30 -20 -10 0 10 20 30 40 50 60-0.5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0MPa (eff.)
R410A
R22
Diagramma di conversione delle temperature e delle pressioni dei refrigeranti
Pre
ssio
ne d
i sat
uraz
ione
del
liqu
ido
(:)
Attrezzatura R410A Possibilità uso attrezzatura R22
Cercafughe
Poiché le pressioni in gioco per l’R410A sono maggiori è impossibile utilizzarecollettori a manometri di tipo tradizionale. Inoltre per impedire introduzioniaccidentali di altri refrigeranti ogni attacco del collettore è stato modificato.
Poiché le pressioni in gioco sono maggiori è necessario utilizzare dei flessibilipiù robusti.
Il cercafughe usato deve essere in grado di rilevare gli HFC.
Da 6,35 e da 9,52 mm.
Motivazioni
Le cartellatrici R410A hanno fori adatti a ricevere tubi di magg. spess., hanno una molla contrasto più robusta.
Serve per utilizzare una cartellatrice per R22.La pompa a vuoto deve essere dotata di una valvola di ritegno (incorporata oppure esterna) che impediscache all’arresto della pompa stessa l’olio contenuto nella pompa possa venire aspirato dal circuito.
Serve perché come tutti gli HFC l’R410A è caratterizzato da un’elevatissima velocità di ebollizione cheprovoca una notevole formazione di bolle che rende difficoltoso l’uso di un normale cilindro carica trasparente.
No
No
No
Sì
Sì
Nuovo
Nuova
Nuova
Collettore amanometri
Flessibile di carica
Chiavedinamometrica
Cartellatrice
Spessimetro cartellatricePompa a vuoto convalvola di ritegno
Bilancia elettronicacarica refrigerante
No: Non adatta per l’uso con 410A Sì: Adatta per l’uso con 410A
No Da 12,7 e da 15,88 mm.
1. Attrezzature specifiche per Refrigerante R410APer il refrigerante R410A servono le attrezzature di seguito indicate anche se per esso possono essere usate alcune delleattrezzature usabili per l’R22. Per prevenire miscelazioni con altri refrigeranti le unità esterne sono dotate di attacchi di servizioaventi diametri differenti da quelli utilizzati nelle unità funzionanti ad R22. Più specificatamente il diametro dei cappellotti èpassato da 7/16 UNF con 20 filetti per pollice a 1/2 UNF con 20 filetti per pollice.
3
R410A
Diametro della tubazione
mm
6.35
9.52
12.7
15.88
17
22
26
29
Dimensione del dado della cartella, mm
R22
17
22
24
27
2Cartellatura e dadi delle cartelleLe cartelle per R410A sono diverse da quelle per R22.Per maggiori dettagli sulle operazioni di cartellatura vedere quanto precisato al paragrafo ‘CARTELLATURA’ del manuale diinstallazione.
3.Lubrificazione delle cartelleLe filettature della cartelle devono essere lubrificate con l’olio per refrigerazione che è fornito a corredo con l’ unità interna.
4.Spurgo dell’aria• L’aria non deve essere mai spurgata scaricando del refrigerante in atmosfera.
E’ inoltre indispensabile evitare di scaricare refrigerante in atmosfera sia durante l’installazione, che la reinstallazione e/o lariparazione dell’unità.
• Per lo spurgo dell’aria è quindi indispensabile utilizzare solo una pompa a vuoto.
5.Rabbocco della carica di refrigeranteOgni rabbocco della carica deve essere eseguito solo spillando refrigerante liquido dalla bombola. Spillando refrigerantegassoso si potrebbe verificare una variazione della composizione sia del refrigerante che resta nella bombola che di quelloche entra nell’unità che provocherebbe un’alterazione delle prestazioni dell’unità stessa. Si noti tuttavia che l’introduzionetroppo rapida di refrigerante liquido potrebbe a sua volta provocare il blocco del compressore. Il refrigerante deve essere quindiintrodotto nell’unità con la massima cautela.
.
2. Realizzazione delle linee frigorifere1Caratteristiche delle tubazioni utilizzabili
Le tubazioni utilizzate devono essere per refrigerazione ed avere le seguenti caratteristiche:
• Utilizzare solo tubi in rame con pareti da 0,8 mm (ø 6.25 - 9.52 – 12.7) o da 1 mm (ø 15,88) di spessore. Non devono esseremai usate tubazioni con pareti di spessore inferiore anche se esse sono più facilmente reperibili sul mercato in quanto nonsarebbero in grado di resistere alle pressioni in gioco.
Spessoredella parete
Diametro esternoLinea
mm
Del liquido
Del gas
6.35
9.52
12.7
15.88
0.8 mm
0.8 mm
0.8 mm
1.0 mm
Schiuma termoresistente.Densità 0,045Spessore 8 mm
Isolamento
Bilancia elettronica
Unità esterna
Valvola diintercettazionedella bombola
Bombola di refrigerantecon pescante interno
Refrigerante in fase liquida
Attacco di servizio
Collettore a manometriper R410A
Giunto
Lato del liquido
Lato del gas
Valvola di intercettazione
Unità interna
Flessibile di carica per R410A
4
2
UNITA’ INTERNA
Griglia
(con griglia aperta)
Telecomando ad infrarossi
Sezione di funzionamento Sezione di visualizzazione
Spie di funzionamento
Ingresso aria
All’interruttore magnetotermico
Cavo di alimentazione
Sezione di ricezionesegnali deltelecomando
Filtro depuratore optional(tipo bianco a soffietto)
Deflettori verticali
Filtro alla catechina
Sezione diricezione segnali
Pannello frontale
MSH-GA50VB -MSH-GA60VB -MSH-GA80VB - E1
E1
E1
ACCESSORI
Unità interna1
2
3
4
5
6
7
Piastra di sospensione
Viti di fissaggio della piastra di sospensione (4 x 25 mm)
Staffa di sospensione del telecomando
Viti fissaggio per staffa di sospensione telecomando 3 3,5 x 1,6 mm (Nere)
Batteria AAA per il telecomando
Telecomando ad infrarossi
Nastro (collegamento tubazione lato sin. o lato posteriore sin.)
1
7
1
2
2
1
1
MSH-GA50VB -MSH-GA60VB -MSH-GA80VB -
E1
E1E1
Deflettoreorizzontale
Interruttore per funzionamentodi emergenza
Spie
NOMENCLATURA E FUNZIONI DELLE PARTI
TELECOMANDO AD INFRAROSSI
MSH-GA50VB -MSH-GA60VB -MSH-GA80VB - E1
E1
E1
ON/OFF TOOCOOL
PM
AM
TOOWARM
ON/OFF
FAN
TOOWARM
TOOCOOL
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
WIDE VANE
LONG
I FEEL COOL
HEAT DRY
PMCLOCK
AM
RESET CLOCK
Apertura delcoperchio frontale
Sezione di trasmissione segnali
Sezione di visualizzazione
Pulsante diMARCIA/ARRESTO (ON/OFF)
Pulsanti di impostazionedella TEMPERATURA
Pulsante CONTROLLO VELOCITA’ VENTILATORE
Pulsante DISATTIVAZIONE TEMPORIZZATA
Pulsanti di IMPOSTAZIONEDEGLI ORARI
HR: OreMIN: Minuti
Pulsante RESET
Pulsante ECONO COOL
Pulsante di controllo deiDEFLETTORI ORIZZONTALI
Pulsante IMPOSTAZIONE OROLOGIO
Pulsante della modalità LONGPulsante WIDE VANE(deflettori verticali)
Indicazione del modellosul lato posteriore
Pulsante di scelta dellaMODALITA’ DI FUNZIONAMENTO
Pulsante ATTIVAZIONE TEMPORIZZATA
5
Flessibile drenaggio
Tubazioni
Ingresso aria Ingresso aria
Uscita aria
Drenaggio condensa
(lato e parte posteriore)
Uscita aria
(lato e parteposteriore)
UNITA’ ESTERNA
ACCESSORI
MUH-GA50VB - E1
Unità esterna
1
2
Attacco di drenaggio
Tappo di drenaggio { 33
Tappo di drenaggio { 16
1
2
—
1
2
1
MUH-GA50VB - E1MUH-GA60VB -MUH-GA80VB -
E1
E1
MUH-GA60VB - MUH-GA80VB - E1E1
6
7
3
Modello Unità Interna
Funzione
Alimentazione
K /hAAW
A(kW)%A
"
mmkg
dBrpm
k"k"
MSH-GA50VB - E1
Monofase230V, 50Hz
768/642 /528100.360—87
0.30RC4V32-AABIA-NER: 293NER-ROS: 146
1.100O325O258165
42/38 /341.070/920 /780
31010
KM04A
Raffreddamento Riscaldamento
MSH-GA60VB - E1
Monofase230V, 50Hz
100.360—87
0.30RC4V32-AABIA-NER: 293NER-ROS: 146
1.100O325O258165
31010
KM04A
Raffreddamento
768/672 /588
45/41 /371.070/960 /850
Riscaldamento
768/642 /528
45/40 /341.070/920 /780
Dat
iel
ettr
ici
Mot
ore
del
vent
ilato
reN
ote
spec
iali
Potenz. w w
w w w w
w w w w
w w
w w
w w
w w
NOTE: Condizioni di riferimento ISO 5151Raffreddamento: Interno 27 °C BS 19 °C BU
Esterno 35 °C BS 24 °C BURiscaldamento Interno 20 °C BS 15,5 °C BU
Esterno 7 °C BS 6 °C BULunghezza delle tubazioni di collegamento: 5 m
w Valori di solo riferimento
K /hAAW
A(kW)%A
"
mmkg
dBrpm
k"k"k"
MSH-GA80VB - E1
Monofase230V, 50Hz
100.3469—88
0.34RC4V40-AA
BIA-NER: 138.2NER-ROS: 159.0
1.100O325O258165
47/42 /37
3101010
KM04A
Raffreddamento
960/822 /684
1.310/1.130 /970
Riscaldamento
960/834 /732
1.310/1.150 /1.020
w ww w
w ww w
w w
Portata d’aria (Alta/Mediaw/Bassaw)Portata linea alimentaz.Corrente assorbitaPotenza assorbitaBatteria elettrica ausiliariaFattore di potenzaCorrente assorbita ventil.ModelloResistenza degliavvolgimenti a 20 °CDimensioni L x H x PPesoDirezioni di mandataLivello sonoro (Alta/Mediaw/Bassaw)Vel. ventil. (Alta/Mediaw/Bassaw)Q.tà velocità ventilatoreResis. termistore RT11 a 25 °CResist. termistore RT12 a 25 °CModello del telecomando
Modello Unità InternaFunzione
Alimentazione
Dat
iel
ettr
ici
Mot
ore
del
vent
ilato
reN
ote
spec
iali
Potenz. Portata d’aria (Alta/Mediaw/Bassaw)Portata linea alimentaz.Corrente assorbitaPotenza assorbitaBatteria elettrica ausiliariaFattore di potenzaCorrente assorbita ventil.ModelloResistenza degliavvolgimenti a 20 °CDimensioni L x H x PPesoDirezioni di mandataLivello sonoro (Alta/Mediaw/Bassaw)Vel. ventil. (Alta/Mediaw/Bassaw)Q.tà velocità ventilatoreResis. termistore RT11 a 25 °CResist. termistore RT12 a 25 °CResist. termistore RT13 a 25 °CModello del telecomando
SPECIFICHE
8
kWr/hK /h
AAW%AAA
W
"
"
mmkgdBrpm
kg
cck"
MUH-GA50VB - E1
Monofase230V, 50Hz
2.19615
37
0.39
RN196VHSHT1.300
C-R 1.80C-S 3.00
RA6V50-PABIA-NER: 79.5NER-ROS: 83.0850o605o290
4752
8281
1.80
520 (NEO22)33.18
Raffreddamento
5.02.5
7.931.720
94
7.54
2.81
Riscaldamento
5.2—
7.231.550
93
6.84
3.23
MUH-GA60VB - E1
Monofase230V, 50Hz
2.76025
74
0.58
NN29VBAHT1.900
C-R 0.80C-S 1.64
RA6V85-DABIA-NER: 68.8NER-ROS: 93.1840o850o330
7453
7301
2.35
1.200 (NEO22)33.18
Raffreddamento
6.33.2
10.392.350
98
9.81
2.61
Riscaldamento
7.2—
10.702.420
98
10.12
2.90
Modello Unità Esterna
Funzione
Alimentazione
ResaDeumidificazionePortata d’aria (Alta)Portata linea alimentazioneCorrente assorbitaPotenza assorbitaFattore di potenzaCorrente di spuntoCorrente assorbita compr.Corrente assorbita ventil.
ModelloPotenza assorbitaResistenza degliavvolgimenti a 20 °CModelloResistenza degliavvolgimenti a 20 °CDimensioni L x H x PPesoLivello sonoro (Alta)Velocità ventilatore (Alta)Q.tà velocità del ventilatoreCarica di R410A
Tipo di olioRes. termistore RT61 a 0 °C
Dat
iel
ettr
ici
Com
pres
sore
Mot
ore
del
vent
ialto
reN
ote
spec
iali
C.O.P.
Pote
nzia
lità
NOTE: Condizioni di riferimento ISO 5151Raffreddamento: Interno 27 °C BS 19 °C BU
Esterno 35 °C BS 24 °C BURiscaldamento Interno 20 °C BS 15,5 °C BU
Esterno 7 °C BS 6 °C BULunghezza delle tubazioni di collegamento: 5 m
w Valori di solo riferimento
Modello Unità EsternaFunzione
Alimentazione
ResaDeumidificazionePortata d’aria (Alta/Bassaw)Portata linea alimentazioneCorrente assorbitaPotenza assorbitaFattore di potenzaCorrente di spuntoCorrente assorbita compr.Corrente assorbita ventil.
ModelloPotenza assorbitaResistenza degliavvolgimenti a 20 °CModelloResistenza degliavvolgimenti a 20 °CDimensioni L x H x PPesoLivello sonoro (Alta/Bassaw)Velocità ventilatore (Alta/Bassaw)Q.tà velocità del ventilatoreCarica di R410A
Tipo di olioResist. termistore RT61 a 0 °CResist. termistore RT62 a 25 °CResist. termistore RT63 a 0 °C
kWR/hK /h
AAW%AAA
W
"
"
mmkgdBrpm
kg
cck"k"k"
MUH-GA80VB - E1
Monofase230V, 50Hz
25
90
0.57
NN37VAAHT2,500
C-R 0.64C-S 1.63
RA6V75-ADBIA-NER: 62.8 NER-GIA: 55.9
GIA-ROS: 26.0840o850o330
7755/53
805/4352
2.40
1.300 (NEO 22)33.18
231.4433.18
Raffreddamento
8.54.6
2.940/1.470
14.423.191
96
13.85
2.61
Riscaldamento
9.4—
2.940/1.470
15.193.361
96
14.62
2.74
Dat
iel
ettr
ici
Com
pres
sore
Mot
ore
del
vent
ialto
reN
ote
spec
iali
C.O.P.
Pote
nzia
lità
w w
w
w
9
NOTE: Condizioni di riferimento ISO 5151Raffreddamento: Interno 27 °C BS 19 °C BU
Esterno 35 °C BS 24 °C BURiscaldamento Interno 20 °C BS 15,5 °C BU
Esterno 7 °C BS 6 °C BULunghezza delle tubazioni di collegamento: 5 m
w Valori di solo riferimento
10
4
90
80
70
60
50
40
30
20
1063 125 250 500 1000 2000 4000 8000
LIVE
LLO
DI P
RES
SIO
NE
SON
OR
A D
ELLE
BA
ND
E D
’OTT
AVA
<dB
> O
dB
= 0
,000
2 µB
ar
FREQUENZE CENTRALI DELLE BANDE D’OTTAVA <Hz>
SOGLIAAPPROSSIMATIVADI UDIBILITÀPER RUMORICONTINUI
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
47
SPL(dB(A)) CURVA
Alta
VELOCITA’
MSH-GA80VB - E1
90
80
70
60
50
40
30
20
1063 125 250 500 1000 2000 4000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
FREQUENZE CENTRALI DELLE BANDE D’OTTAVA <Hz>
Condizioni di riferimento:Raffreddamento: Temperatura a B.S. : 27 °C Temperatura a B.U. : 19,0 °CRiscaldamento: Temperatura a B.S. : 20 °C Temperatura a B.U. : 15,5 °C
SOGLIAAPPROSSIMATIVADI UDIBILITÀPER RUMORICONTINUI
42
SPL(dB(A)) CURVA
Alta
VELOCITA’
LIVE
LLO
DI P
RES
SIO
NE
SON
OR
A D
ELLE
BA
ND
E D
’OTT
AVA
<dB
> O
dB
= 0
,000
2 µB
ar 90
80
70
60
50
40
30
20
1063 125 250 500 1000 2000 4000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
FREQUENZE CENTRALI DELLE BANDE D’OTTAVA <Hz>
Condizioni di riferimento:Raffreddamento: Temperatura a B.S. : 27 °C Temperatura a B.U.: 19,0 °CRiscaldamento: Temperatura a B.S. : 20 °C Temperatura a B.U.: 15,5 °C
SOGLIAAPPROSSIMATIVADI UDIBILITÀPER RUMORICONTINUI
45
SPL(dB(A)) CURVA
Alta
VELOCITA’
LIVE
LLO
DI P
RES
SIO
NE
SON
OR
A D
ELLE
BA
ND
E D
’OTT
AVA
<dB
> O
dB
= 0
,000
2 µB
ar
MSH-GA50VB - E1 MSH-GA60VB - E1
UNITA’ INTERNAPARETE
MICROFONO
0.8m
1m
LIVELLI SONORI
Condizioni di riferimento:Raffreddamento: Temperatura a B.S. : 27 °C Temperatura a B.U. : 19,0 °CRiscaldamento: Temperatura a B.S. : 20 °C Temperatura a B.U. : 15,5 °C
11
90
80
70
60
50
40
30
20
1063 125 250 500 1000 2000 4000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
FREQUENZE CENTRALI DELLE BANDE D’OTTAVA <Hz>
SOGLIAAPPROSSIMATIVADI UDIBILITÀPER RUMORICONTINUI
52
SPL(dB(A)) CURVA
Alta
VELOCITA’
90
80
70
60
50
40
30
20
1063 125 250 500 1000 2000 4000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
FREQUENZE CENTRALI DELLE BANDE D’OTTAVA <Hz>
T
SOGLIAAPPROSSIMATIVADI UDIBILITÀPER RUMORICONTINUI
53
SPL(dB(A)) CURVA
Alta
VELOCITA’
MUH-GA50VB - E1 MUH-GA60VB - E1
90
80
70
60
50
40
30
20
1063 125 250 500 1000 2000 4000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
FREQUENZE CENTRALI DELLE BANDE D’OTTAVA <Hz>
SOGLIAAPPROSSIMATIVADI UDIBILITÀPER RUMORICONTINUI
55
SPL(dB(A)) CURVA
Alta
VELOCITA’
MUH-GA80VB - E1
UNITA’ ESTERNA
MICROFONO
1m
Condizioni di riferimento:Raffreddamento: Temperatura a B.S. : 27 °C Temperatura a B.U. : 19,0 °CRiscaldamento: Temperatura a B.S. : 20 °C Temperatura a B.U. : 15,5 °C
LIVE
LLO
DI P
RES
SIO
NE
SON
OR
A D
ELLE
BA
ND
E D
’OTT
AVA
<dB
> O
dB
= 0
,000
2 µB
ar
Condizioni di riferimento:Raffreddamento: Temperatura a B.S. : 27 °C Temperatura a B.U. : 19,0 °CRiscaldamento: Temperatura a B.S. : 20 °C Temperatura a B.U. : 15,5 °C
LIVE
LLO
DI P
RES
SIO
NE
SON
OR
A D
ELLE
BA
ND
E D
’OTT
AVA
<dB
> O
dB
= 0
,000
2 µB
ar
Condizioni di riferimento:Raffreddamento: Temperatura a B.S. : 27 °C Temperatura a B.U. : 19,0 °CRiscaldamento: Temperatura a B.S. : 20 °C Temperatura a B.U. : 15,5 °C
LIVE
LLO
DI P
RES
SIO
NE
SON
OR
A D
ELLE
BA
ND
E D
’OTT
AVA
<dB
> O
dB
= 0
,000
2 µB
ar
12
5
258
162
1958
47
7.5
315
255.
5472.5
98 173
98 173414.5 414.5
5
25379156
1068
1100
325
Uscita aria
Ingresso aria
Isolamento [ 28
Flessibile di drenaggio [ 16(O.D. della linea da collegare)
Piastra sospensione
Foro a parete [75
Telecomando ad infrarossi
Piastra di sospensione Unità Interna
{Linea liquido [ 6.35-0.5mLinea gas [ 12-0.43mIsolamento [ 50 O.D
[ 32 I.D
{Linea liquido [ 9.52-0.5mLinea gas [ 12-0.43mIsolamento [ 50 O.D
[ 32 I.D
(Mod. MSH-GA50VB)
(Modd. MSH-GA60/GA80VB)
Cavo di alimentazioneSporgenza a destra: 2,0 mSporgenza a sinistra: 1,0 m
UNITA’ INTERNA
MSH-GA50VB -MSH-GA60VB -MSH-GA80VB - E1
E1
E1 Unità: mm
DISEGNI DIMENSIONALI
13
MUH-GA60VB - MUH-GA80VB - E1E1
UNITA’ ESTERNA
Unità: mm
UNITA’ ESTERNAMUH-GA50VB - E1
100
mm
min
.
100 mm min.
100 mm min.
350 mm min.500 mm min.
SPAZI DI RISPETTO
3 fori di drenaggio[ 33
Uscita aria
Air in
Ingresso aria
Pannello di servizio
Attacco del liquido
Linea del liquido(cartellata) [ 6.35
Attacco del gas
Linea del gas (cartellata)[12.7
35-
30-
30
100
161
157
74850500
1832029
2
605
248
35
350
50
290
310
345
20355
90
Foro didrenaggio [ 16.2
30-
35-
155
90
198
40
515299
66
345133
0
360
850
430
50080
121840
Preferibilmente libero (500mm min. se entrambi ifianchi ed il lato frontalesono sgombri da ostacoli)
100 mm min.200 mm min.se ci fosseroostacoli suentrambi i lati
Preferibilmente libero(500 mm min. se entrambi i fianchied i lati superiore e posteriore sonosgombri da ostacoli)
350 mm min.
100 mm min.
Pannello di servizio
Attacco del gasLinea del gas(cartellata) [15.88
Attacco del liquido
Linea del liquido(cartellata) [6.35 (MUH-GA60VB)
[9.52 (MUH-GA80VB)
SPAZI DI RISPETTO
14
6
MSH-GA50VB -MSH-GA60VB - E1
E1
SCHEMA ELETTRICO
UNITA’ INTERNA
NOTE: 1. Vedere lo schema elettrico dell’unità esterna per quanto riguarda quest’ultima2. Per i collegamenti esterni devono essere usati solo cavi con conduttori in rame3. Simbologia:
: Morsettiera : Connettore
SIMBOLO
C11
F11
HIC1
MF
NOME
CONDENSATORE VENTILAT.
FUSIBILE DA 3,15 A
CONVERTITORE C,C../C.C.
MOT. VENTIL. (FUS. INTERNO)
SIMBOLO
MV1
MV2
NR11
RT11
NOME SIMBOLO
RT12
SR141
TB
NOME
TB
TAB12
3 3
TELECOMANDO
SCHEDA DELRICEVITORE
SCHEDA DIVISUALIZZ.
102CN
101CN
ROS
BLU
MV2
CN201321
MARL
N
3
F11
SCHEDA DICONTROLLO
NR11
CN211CN111 RT11
RT12
15
MV2
CN151
CN11212
MV1
HIC1
C11
121CN
134
SR141
3
MF
ROSBIAMARGIAGRINER
VER/
GIA
BLU
PE
MAR
ALL’UNITA’ESTERNA
12V
123456
MAGNETOTERMICO
CAVO DIALIMENTA-ZIONE(F/N 230 V -50 Hz)
UNITA’ INTERNA
12V
ALL’UNITA’ESTERNA
MAR
BLU
VER/
GIA
NERGRIGIAMARBIAROS
MF
3
SR141431
CN121
C11
HIC1
MV1
RT134321
CN112
151CN
MV2
15
RT12
RT11111CN
CN211
NR11
ELECTR
F11
3
N
L MAR
123
CN201
MV2
BLU
ROS
CN101
CN102
SCHEDA DIVISUALIZZ.
SCHEDA DELRICEVITORE
TELECOMANDO
33
TAB12
TB
PE
NOTE: 1. Vedere lo schema elettrico dell’unità esterna per quanto riguarda quest’ultima2. Per i collegamenti esterni devono essere usati solo cavi con conduttori in rame3. Simbologia:
: Morsettiera : Connettore
SR141
TB
MV2
NR11
RT11
RT12
RT13
C11
F11
HIC1
MF
MV1
MSH-GA80VB - E1 SCHEMA ELETTRICO
SERVOMOTORE DEFLETTORE ORIZZ.
SERVOMOTORE DEFLETTORE VERT.
VARISTORE
TERMISTORE TEMP. AMBIENTE
TERMISTORE BATTERIA INTERNA
RELAY A STATO SOLIDO
MORSETTIERA
MAGNETOTERMICO
CAVO DIALIMENTA-ZIONE(F/N 230 V -50 Hz)
SIMBOLO NOME
CONDENSATORE VENTILAT.
FUSIBILE DA 3,15 A
CONVERTITORE C,C../C.C.
MOT. VENTIL. (FUS. INTERNO)
SERVOMOTORE DEFLETTORE ORIZZ.
SIMBOLO NOME SIMBOLO NOME
SERVOMOTORE DEFLETTORE VERT.
VARISTORE
TERMISTORE TEMP. AMBIENTE
TERMISTORE PRINC. TEMP. BATTERIA
TERMISTORE SEC. TEMP. BATTERIA
RELAY A STATO SOLIDO
MORSETTIERA
SCHEMI ELETTRICI
15
MUH-GA60VB - E1 SCHEMA ELETTRICOUNITA’ ESTERNA
SCHEDA DISBRINAMENTO
BLU
X52
X52NOCOM
TAB52
BLU 52C A2A1
T61
NE
RB
IA
ROS
MA
AR
TB2
7
1
CN730
NE
RB
IA
MAGNETOTERMICO
CN721
3
52C4
ROSC2ARA
DS
AR
12
V
BIA
C1
NER
S
C
RMC
ROS
NR61 35
BLU
TB1
VE
R/G
IAALI
ME
NTA
ZIO
NE
(F/N
230
V –
50
Hz) CN661
RT61
X62 X62
123
21S4
BLU
MAR
BLU
MAR
SR61
F61
CN711
MF
1 2 3
2 1
AR
AR
OS
34
NOCOM
DA
LL’U
NIT
A’ I
NT
ER
NA
N
3
N
L
PE
NOTE: 1. Vedere lo schema elettrico dell’unità interna per quanto riguarda quest’ultima2. Per i collegamenti esterni devono essere usati solo cavi con conduttori in rame3. Simbologia:
: Morsettiera : Connettore
SIMBOLO
C1
C2
DSAR
F61
MC
MF
NR61
RT61
SR61
TB1
TB2
T61
X52
X62
21S4
52C
NOME
CONDENSATORE DEL COMPRESSORE
CONDENSATORE DEL VENTILATORE
FILTRO ANTI DISTURBI
FUSIBILE DA 3.15 A
COMPRESSORE (PROTEZ. INTERNA)
MOTORE VENTILAT. (PROTEZ. INTERNA)
VARISTORE
TERMISTORE DI SBRINAMENTO
RELAY A STATO SOLIDO
MORSETTIERA
MORSETTIERA
TRASFORMATORE
CONTATTORE
RELAY BOBINA VALVOLA INVERSIONE
BOBINA VALVOLA DI INVERSIONE
CONTATTORE DEL COMPRESSORE
MUH-GA50VB - E1 SCHEMA ELETTRICOUNITA’ ESTERNA
MC
CN661
3
12
CN721
21S4 MF
SR
62
SR61
TAB20
VE
R/G
IA
BLU
MAGNETOTERMICO
ALIMENTAZIONE(F/N 230 V -50 Hz) BLU
MAR
DS
AR
NER
MAR
ROS
SCHEDA SBRINAMENTO4
C1
BIA
ROS
3
BIA
S
C
RC
N73
0
RT61
NER23
1
ROS
BIA12V
DALL’UNITA’INTERNA
TB23
N
TB1L
N
PE
NR
61
F61
T61 C65
CN711
52C
1 2 3 4
BIA
NE
R
RO
SA
RA
NOTE: 1. Vedere lo schema elettrico dell’unità interna per quanto riguarda quest’ultima2. Per i collegamenti esterni devono essere usati solo cavi con conduttori in rame3. Simbologia:
: Morsettiera : Connettore
SIMBOLO
C1
C65
DSAR
F61
MC
NOME
CONDENSATORE COMPRES.
CONDENSATORE VENTILAT.
FILTRO ANTI DISTURBI
FUSIBILE DA 2 A
COMPRESS. (PROTEZ. INTERNA)
SIMBOLO
MF
NR61
RT61
SR61,SR62
T61
NOME SIMBOLO
TB1,TB2
21S4
52C
NOME
MOTORE VENTILAT. (PROTEZ. INTERNA)
VARISTORE
TERMISTORE DI SBRINAMENTO
RELAY A STATO SOLIDO
TRASFORMATORE
MORSETTIERA
BOBINA V.I.
CONTATTORE COMPRES.
16
UNITA’ ESTERNA
DEICERT61
GIA
NE
RB
IA
ROS
MA
R
TB2
7
1
CN730
BIA
NE
RB
IA
MAGNETOTERMICO
CN721
1
52C2
CZ BIABIA
ROSC2ARA
A1 A2BLU 52C
DS
AR
DA
LL’U
NIT
A’ I
NT
ER
NA
12
V
BIA
C1NER
S
C
RMC
ROS
BLU
NR61 35
BLU
TB1
VE
R/G
IAALI
ME
NTA
ZIO
NE
(F/N
230
V –
50
Hz) CN661
RT61
X52X62 X62123
21S4
BLU
MAR
BLU
MAR
SR62
SR61
COM NO
F61
TAB52X52
CN711CN724CN662
6
MFRT62 RT63
1 2 3
2 1
AR
AR
OS
3456
LEV
NOCOM
N
3
N
L
PE
SIMBOLO
TB1
TB2
T61
X52
X62
21S4
52C
SIMBOLO
MF
NR61
RT61
RT62
RT63
SR61
SR62
SIMBOLO
CZ
C1
C2
DSAR
F61
LEV
MC
NOME NOME NOME
FILTRO ANTI DISTURBI CZ
CONDENSATORE COMPRESSORE
CONDENSATORE VENTILATORE
FILTRO ANTI DISTURBI
FUSIBILE DA 3.15 A
BOBINA VALVOLA D’ESPANSIONE
COMPRESSORE (PROTEZ. INTERNA)
NOTE: 1. Vedere lo schema elettrico dell’unità interna per quanto riguarda quest’ultima2. Per i collegamenti esterni devono essere usati solo cavi con conduttori in rame3. Simbologia:
: Morsettiera : Connettore
MUH-GA80VB - E1 SCHEMA ELETTRICO
MOTORE VENTIL. (PROTEZ. INTERNA)
VARISTORE
TERMISTORE DI SBRINAMENTO
TERMISTORE TEMP. DI MANDATA
TERMISTORE DELLA TEMP. ESTERNA
RELAY A STATO SOLIDO
RELAY A STATO SOLIDO
MORSETTIERA
MORSETTIERA
TRASFORMATORE
CONTATTORE
RELAY BOBINA VALVOLA DI INVERSIONE
BOBINA VALVOLA DI INVERSIONE
CONTATTORE DEL COMPRESSORE
UNITA’ INTERNA
17
7
MSH-GA80VB - E1
Batteriainterna
Attacco a cartella
Termistore dellatemperaturaambienteRT11
Termistoresecondariodella batteriainterna RT12
Attacco a cartella
Linea frigorifera isolata[ 15.88
Linea frigorifera isolata[ 9.52
Termistoreprincipale dellabatteria interna RT12
Filtro#50
Flusso del refrigerante in raffreddamento
Flusso del refrigerante in riscaldamento
MSH-GA50VB - E1
Batteriainterna
Termistore dellatemperaturaambienteRT11
Linea frigorifera isolata[ 12.7
Attacco a cartella
Attacco a cartella
Termistoredella batteriainterna RT12
Linea frigorifera isolata[ 6.35
Distributore
MSH-GA60VB - E1
Batteriainterna
Termistore dellatemperaturaambienteRT11
Linea frigorifera isolata[ 15.88
Attacco a cartella
Attacco a cartella
Termistoredella batteriainterna RT12
Linea frigorifera isolata[ 6.35
Distributore
UNITA’ INTERNA
UNITA’ INTERNA
SCHEMI FRIGORIFERI
18
Silenziatore
MUH-GA50VB - E1
UNITA’ ESTERNALinea frigorifera isolata[ 12.7
Attacco a cartella
Attacco a cartella
Linea frigorifera isolata[ 6.35
Valvola diintercettazione
Valvoladi ritegno
Capillare[3.0o[1.6o450
Capillare[3.0o[1.6o750(2 pcs)
Compressore
Valvola diintercettazionecon attaccodi servizio
Batteriadell’unitàesternaTermistore
disbrinamento
Bobina valvola di inversioneEccitata: RiscaldamentoDiseccitata: Raffreddamento
Valvola di inversione
MUH-GA60VB - E1
UNITA’ ESTERNALinea frigorifera isolata[ 15.88
Attacco a cartella
Attacco a cartella
Linea frigorifera isolata[ 6.35
Valvola diintercettazione
Ricevitore
Valvola di ritegno
Capillare[3.0X[2.0X750
Termistore disbrinamento
Compressore
Valvola diintercettazionecon attacco diservizio
Batteriadell’unitàesterna
Flusso del refrigerante in raffreddamento
Flusso del refrigerante in riscaldamento
Silenziatore#100
Valvola di inversione
[3.0X[2.0X750
Capillare
Bobina valvola di inversioneEccitata: RiscaldamentoDiseccitata: Raffreddamento
Capillare[3.0o[1.6o300
Silenziatore
Filtro#100
Filtro#100
19
MUH-GA80VB - E1
UNITA’ ESTERNA
Batteriadell’unitàesterna
Attacco a cartella
Termistore disbrinamento
Termistore dellatemperaturadi mandataRT62
Attacco a cartella
Valvola diintercettazione
Valvola diintercettazionecon attaccodi servizio
Flusso del refrigerante in raffreddamento[3.6✕[2.4✕50
Flusso del refrigerante in raffreddamentoFlusso del refrigerante in riscaldamento
Compressore
Valvola diinversione
Linea frigoriferaisolata [ 15.88
Linea frigoriferaisolata [ 9.52
LEV Bobina valvola di inversioneEccitata: RiscaldamentoDiseccitata: Raffreddamento
Silenziatore#100
Filtro#100Ricevitore
Silenziatore
Termistoredella temperaturaesterna
Filtro#100
Unitàinterna
wIndipendentemente daquale delle due unità sitrovi in posizione superioreil dislivello massimocorrisponde a:10 m (MS-GA50/GA60VB)15 m (MS-GA80VB)
A
Lunghezza massimadelle linee frigorifere
w I dislivelli massimi indicati valgono indipendentemente dal fatto che l’ unità interna si trovi ad una quotasuperiore o inferiore a quella dell’ unità esterna.
Unità esterna
DISLIVELLI MASSIMI
LUNGHEZZE MASSIME DELLE LINEE FRIGORIFERE
ModelloD.E. (mm) delle linee
Lunghezza della tubazionedi collegamento (m)
Lunghezza massima
delle linee frigorifere (m)
A
25
30
Unità interna
Gas: 0,43
Liquido: 0,5
Gas
12.7
15.88
Liquido
6.35
9.52
MUH-GA50VB - E1
MUH-GA60VB - E1
MUH-GA80VB - E1
Unità esterna
Gas: 0
Liquido: 0
20
Modello
MUH-GA50VB - E1
Lunghezza delle linee in un sol sensoPrecaricadell’unità esterna
1.800
15m
160
20m
260
25m
360
7m
0
10m
60
RABBOCCHI DELLA CARICA DI REFRIGERANTE R410A (g)
Rabbocco: Xg = 20 g/m x (A-7) m
Modello
MUH-GA60VB - E1
Lunghezza delle linee in un sol sensoPrecaricadell’unità esterna
2.350
15m
160
20m
260
25m
360
7m
0
10m
60
Rabbocco: Xg = 20 g/m x (A-7) m
Precaricadell’unità esterna
2.400 0 165 440 715 990 1.265
Lunghezza delle linee in un sol senso
15m10m7mModello
MUH-GA80VB - E1
20m 25m 30m
Rabbocco: Xg = 20 g/m x (A-7) m
21
8
11.6
10.5
7.5
8.5
9.5
12.8
15.6
9.8
12.6
11.2
14.1
17.2
17.4
13.9
12.4
10.8
15.6
19.2
MU
H-G
A50
VB
-E
1
MS
H-G
A60
VB
-E
1
MS
H-G
A50
VB
-E
1
MU
H-G
A60
VB
-E
1
MS
H-G
A80
VB
-E
1
MU
H-G
A80
VB
-E
1
Poiché le condizioni di funzionamento variano in funzione delle aree geografiche in cui avviene l’installazione, i dati standardpubblicati su questo manuale sono riferiti solo alle normali condizioni di funzionamento. Quanto segue viene precisatoallo scopo di chiarire le caratteristiche di funzionamento di questi climatizzatori che sono riportate sulle curve delle prestazioni.
(1) TENSIONE DI ALIMENTAZIONE AMMISSIBILETra 198 e 264 V, monofase a 50 Hz.
(2) PORTATA D’ARIALa portata d’aria deve corrispondere alla MASSIMA.
(3) PARAMETRI PRINCIPALI(1) Temperatura di ingresso aria a bulbo umido (unità interna) °C BU(2) Temperatura di uscita aria a bulbo umido (unità interna) °C BU raffreddamento(3) Temperatura di ingresso aria a bulbo secco (unità esterna) °C BS(4) Potenza assorbita totale W(5) Temperatura di ingresso aria a bulbo secco (unità interna) °C BS(6) Temperatura di ingresso aria a bulbo umido (unità esterna) °C BU riscaldamento(7) Potenza assorbita totale W
La differenza tra le temperature di ingresso e di uscita a bulbo secco o a bulbo umido dell’unità interna riportate sulle ordinatedei diagrammi di seguito pubblicati servono come riferimento per le eventuali operazioni di servizio.
Modalità di lettura delle differenze tra le temperature di ingresso e di uscita a bulbo secco o a bulboumido dell’unità interna1. Montare sull’unità almeno due serie di termometri a bulbo secco ed a bulbo umido sia sulla bocca d’ingresso che su quella
d’uscita dell’aria dell’unità interna, così come indicato in figura. I termometri devono essere posti in posizioni in cui il flussod’aria sia vivace.
2. Montare almeno due termometri a bulbo secco sull’ingresso aria dell’unità esterna. Tali termometri devono essere schermatidai raggi solari.
3. Controllare che il filtro dell’aria sia ben pulito.4. Aprire le porte e le finestre del locale.5. Premere una volta (due volte) il pulsante di FUNZIONAMENTO DI EMERGENZA per attivare il FUNZIONAMENTO DI
EMERGENZA IN MODALITA’ DI RAFFREDDAMENTO (RISCALDAMENTO).6. Lasciare trascorrere almeno 15 minuti per consentire la stabilizzazione del funzionamento e poi misurare le temperature ed
eseguirne la media.7. Lasciare trascorrere altri 10 minuti e poi controllare che le letture dei termometri non siano cambiate.
UNITA’ INTERNA UNITA’ ESTERNA
}}
Termometri a bulbo seccoed a bulbo umido
VISTA POSTERIORE
MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1E1E1
Termometri a bulbo seccoed a bulbo umido
VISTA FRONTALE
Temperatura ingresso a BS dell’aria nell’unità esterna (°C)Temperatura ingresso a BS dell’aria nell’unità esterna (°C)
Potenzialità frigorifere Potenza assorbita in raffreddamento
Fatto
re d
i cor
rezio
ne d
ella
pot
enza
ass
orbi
ta
Fatto
re d
i cor
rezio
ne d
ella
pot
enzia
lità
Diffe
renz
a de
lla te
mpe
ratu
ra a
BU
dell’
aria
sul
l’uni
tà in
tern
a (°C
)
Temperatura d’ingresso a BU dell’aria nell’unità interna (°C)Temperatura d’ingresso a BU dell’aria nell’unità interna (°C)
PRESTAZIONI
22
26.6
24.5
22.5
20.4
18.4
16.3
14.3
12.3
36.8
34.0
31.1
28.3
25.5
22.6
19.8
17.0
38.4
35.5
32.5
29.6
26.6
23.6
20.7
17.7
MU
H-G
A50
VB
-E
1
MS
H-G
A60
VB
-E
1
MS
H-G
A50
VB
-E
1
MU
H-G
A60
VB
-E
1
MS
H-G
A80
VB
-E
1M
UH
-GA
80V
B -
E1
NOTA: Le curve di riscaldamento sono riferite al funzionamento senzabrinatura della batteria dell’unità esterna
PRESSIONE DI BASSA NELL’UNITA’ ESTERNA E CORRENTE ASSORBITA DALL’UNITA’ ESTERNAFunzionamento in RAFFREDDAMENTO
1 Con unità interna ed unità esterna che aspirano aria alle stesse condizioni termoigrometriche.
2 Con il ventilatore funzionante a massima velocità
Temperatura a Bulbo Secco (°C) Umidità Relativa (%)
20 50
25 60
30 70
3 Le pressioni sono espresse in MPa come da norme SI. L’equivalenza con le vecchie unità di misura della pressione è laseguente: 1 MPa = 10,2 kgf/cm2
18 3270(%)
230V
15 2050
2560
30 350.7
0.8
0.9
1.0
1.1
1.2
1.3
7
8
9
10
11
12
13
(:) 15 2050
2560
3070(%)
35(:)5
6
8
7
18 32
230V
MUH-GA50VB - E1MUH-GA50VB - E1
Pres
sion
e di
bas
sa n
ell’u
nità
est
erna
Temperatura dell’aria (°C)Umidità dell’aria (%)
Temperatura dell’aria (°C)Umidità dell’aria (%)
Cor
rent
e as
sorb
ita d
all’u
nità
est
erna
(A)
(kg/cm2 eff.) (MPa eff.)
(kg/cm2 eff.) (MPa eff.)
18 3270(%)
230V
15 2050
2560
30 350.6
0.7
0.8
0.9
1.0
1.1
(:)6
7
8
9
10
11MUH-GA60VB - E1
Pres
sion
e di
bas
sa n
ell’u
nità
est
erna
Temperatura dell’aria (°C)Umidità dell’aria (%)
10
11
8
9
230V
MUH-GA60VB - E1
Temperatura dell’aria (°C)Umidità dell’aria (%)
Cor
rent
e as
sorb
ita d
all’u
nità
est
erna
(A)
Temperatura d’ingresso a BU dell’aria nell’unità esterna (°C)
Potenza assorbita in riscaldamento
Fatto
re d
i cor
rezio
ne d
ella
pot
enza
ass
orbi
ta
Potenzialità di riscaldamento
Temperatura d’ingresso a BU dell’aria nell’unità esterna (°C)
Temperatura d’ingresso a BS dell’aria nell’unità interna (°C)
Temperatura d’ingresso a BS dell’aria nell’unità interna (°C)
Fatto
re d
i cor
rezio
ne d
ella
pot
enza
Diffe
renz
a de
lla te
mpe
ratu
ra a
BS
dell’
aria
sul
l’uni
tà in
tern
a (°C
)
23
26.6
24.5
22.5
20.4
18.4
16.3
14.3
12.3
36.8
34.0
31.1
28.3
25.5
22.6
19.8
17.0
38.4
35.5
32.5
29.6
26.6
23.6
20.7
17.7
MU
H-G
A50
VB
-E
1
MS
H-G
A60
VB
-E
1
MS
H-G
A50
VB
-E
1
MU
H-G
A60
VB
-E
1
MS
H-G
A80
VB
-E
1M
UH
-GA
80V
B -
E1
NOTA: Le curve di riscaldamento sono riferite al funzionamento senzabrinatura della batteria dell’unità esterna
PRESSIONE DI BASSA NELL’UNITA’ ESTERNA E CORRENTE ASSORBITA DALL’UNITA’ ESTERNAFunzionamento in RAFFREDDAMENTO
1 Con unità interna ed unità esterna che aspirano aria alle stesse condizioni termoigrometriche
2 Con il ventilatore funzionante a massima velocità
Temperatura a Bulbo Secco (°C) Umidità Relativa (%)
20 50
25 60
30 70
3 Le pressioni sono espresse in MPa come da norme SI. L’equivalenza con le vecchie unità di misura della pressione è laseguente: 1 MPa = 10,2 kgf/cm2
18 3270(%)
230V
15 2050
2560
30 350.7
0.8
0.9
1.0
1.1
1.2
1.3
7
8
9
10
11
12
13
(:) 15 2050
2560
3070(%)
35(:)5
6
8
7
18 32
230V
MUH-GA50VB - E1MUH-GA50VB - E1
Pre
ssio
ne d
i bas
sa n
ell’u
nità
est
erna
Temperatura dell’aria (°C)Umidità dell’aria (%)
Temperatura dell’aria (°C)Umidità dell’aria (%)
Corre
nte
asso
rbita
dal
l’uni
tà e
ster
na (A
)
(kg/cm2 eff.) (MPa eff.)
(kg/cm2 eff.) (MPa eff.)
18 3270(%)
230V
15 2050
2560
30 350.6
0.7
0.8
0.9
1.0
1.1
(:)6
7
8
9
10
11MUH-GA60VB - E1
Pre
ssio
ne d
i bas
sa n
ell’u
nità
est
erna
Temperatura dell’aria (°C)Umidità dell’aria (%)
10
11
8
9
230V
MUH-GA60VB - E1
Temperatura dell’aria (°C)Umidità dell’aria (%)
Corre
nte
asso
rbita
dal
l’uni
tà e
ster
na (A
)
Temperatura d’ingresso a BU dell’aria nell’unità esterna (°C)
Potenza assorbita in riscaldamento
Fatto
re d
i cor
rezio
ne d
ella
pot
enza
ass
orbi
ta
Potenzialità di riscaldamento
Temperatura d’ingresso a BU dell’aria nell’unità esterna (°C)
Temperatura d’ingresso a BS dell’aria nell’unità interna (°C)
Temperatura d’ingresso a BS dell’aria nell’unità interna (°C)
Fatto
re d
i cor
rezio
ne d
ella
pot
enza
Diffe
renz
a de
lla te
mpe
ratu
ra a
BS
dell’
aria
sul
l’uni
tà in
tern
a (°C
)
24
Funzionamento in RISCALDAMENTOCondizioni interne: Temperatura a BS: 20.0°C
Temperatura a BU: 14.5° C
Condizioni esterne: Temperatura a BS: 7,15,20°CTemperatura a BU: 6,12,14.5°C
MUH-GA50VB - E1
5 10 15 20 257
8
9
10
7 21
230V
(:)
Corre
nte
asso
rbita
dal
l’uni
tà e
ster
na (A
)
Temperatura dell’aria esterna (°C)
14
13
12
11
230V
Corre
nte
asso
rbita
dal
l’uni
tà e
ster
na (A
)
Temperatura dell’aria esterna (°C)
MUH-GA60VB - E1
MUH-GA80VB - E1
Temperatura dell’aria (°C)Umidità dell’aria (%)
18 3270(%)
230V
15 2050
2560
30 355
6
7
8
9
10
11
(:)5
6
7
8
9
10
11
Temperatura dell’aria (°C)Umidità dell’aria (%)
18 3270(%)
230V
15 2050
2560
30 3510
11
12
13
14
15
16
(:)
Pres
sion
e di
bas
sa n
ell’u
nità
est
erna
Cor
rent
e as
sorb
ita d
all’u
nità
est
erna
(A)(kg/cm2 eff.) (MPa eff.) MUH-GA80VB - E1
Temperatura dell’aria esterna (°C)
7 21
230V
(:)5 10 15 20 2516
17
18
19
20
Corre
nte
asso
rbita
dal
l’uni
tà e
ster
na (A
)
MUH-GA80VB - E1
25
MSH-GA50VB - : MUH-GA50VB - (230V)E1E1
21 18 5.88 2.76 0.47 1424 5.63 2.64 0.47 1495 5.40 2.54 0.47 1566 5.20 2.44 0.47 163821 20 6.13 2.14 0.35 1495 5.88 2.06 0.35 1584 5.70 2.00 0.35 1620 5.50 1.93 0.35 169122 18 5.88 3.00 0.51 1424 5.63 2.87 0.51 1495 5.40 2.75 0.51 1566 5.20 2.65 0.51 163822 20 6.13 2.39 0.39 1495 5.88 2.29 0.39 1584 5.70 2.22 0.39 1620 5.50 2.15 0.39 169122 22 6.38 1.72 0.27 1549 6.15 1.66 0.27 1647 6.00 1.62 0.27 1691 5.75 1.55 0.27 176223 18 5.88 3.23 0.55 1424 5.63 3.09 0.55 1495 5.40 2.97 0.55 1566 5.20 2.86 0.55 163823 20 6.13 2.63 0.43 1495 5.88 2.53 0.43 1584 5.70 2.45 0.43 1620 5.50 2.37 0.43 169123 22 6.38 1.98 0.31 1549 6.15 1.91 0.31 1647 6.00 1.86 0.31 1691 5.75 1.78 0.31 176224 18 5.88 3.47 0.59 1424 5.63 3.32 0.59 1495 5.40 3.19 0.59 1566 5.20 3.07 0.59 163824 20 6.13 2.88 0.47 1495 5.88 2.76 0.47 1584 5.70 2.68 0.47 1620 5.50 2.59 0.47 169124 22 6.38 2.23 0.35 1549 6.15 2.15 0.35 1647 6.00 2.10 0.35 1691 5.75 2.01 0.35 176224 24 6.70 1.54 0.23 1620 6.45 1.48 0.23 1709 6.30 1.45 0.23 1762 6.10 1.40 0.23 185125 18 5.88 3.70 0.63 1424 5.63 3.54 0.63 1495 5.40 3.40 0.63 1566 5.20 3.28 0.63 163825 20 6.13 3.12 0.51 1495 5.88 3.00 0.51 1584 5.70 2.91 0.51 1620 5.50 2.81 0.51 169125 22 6.38 2.49 0.39 1549 6.15 2.40 0.39 1647 6.00 2.34 0.39 1691 5.75 2.24 0.39 176225 24 6.70 1.81 0.27 1620 6.45 1.74 0.27 1709 6.30 1.70 0.27 1762 6.10 1.65 0.27 185126 18 5.88 3.94 0.67 1424 5.63 3.77 0.67 1495 5.40 3.62 0.67 1566 5.20 3.48 0.67 163826 20 6.13 3.37 0.55 1495 5.88 3.23 0.55 1584 5.70 3.14 0.55 1620 5.50 3.03 0.55 169126 22 6.38 2.74 0.43 1549 6.15 2.64 0.43 1647 6.00 2.58 0.43 1691 5.75 2.47 0.43 176226 24 6.70 2.08 0.31 1620 6.45 2.00 0.31 1709 6.30 1.95 0.31 1762 6.10 1.89 0.31 185126 26 6.90 1.31 0.19 1709 6.70 1.27 0.19 1798 6.60 1.25 0.19 1851 6.40 1.22 0.19 190527 18 5.88 4.17 0.71 1424 5.63 3.99 0.71 1495 5.40 3.83 0.71 1566 5.20 3.69 0.71 163827 20 6.13 3.61 0.59 1495 5.88 3.47 0.59 1584 5.70 3.36 0.59 1620 5.50 3.25 0.59 169127 22 6.38 3.00 0.47 1549 6.15 2.89 0.47 1647 6.00 2.82 0.47 1691 5.75 2.70 0.47 176227 24 6.70 2.35 0.35 1620 6.45 2.26 0.35 1709 6.30 2.21 0.35 1762 6.10 2.14 0.35 185127 26 6.90 1.59 0.23 1709 6.70 1.54 0.23 1798 6.60 1.52 0.23 1851 6.40 1.47 0.23 190528 18 5.88 4.41 0.75 1424 5.63 4.22 0.75 1495 5.40 4.05 0.75 1566 5.20 3.90 0.75 163828 20 6.13 3.86 0.63 1495 5.88 3.70 0.63 1584 5.70 3.59 0.63 1620 5.50 3.47 0.63 169128 22 6.38 3.25 0.51 1549 6.15 3.14 0.51 1647 6.00 3.06 0.51 1691 5.75 2.93 0.51 176228 24 6.70 2.61 0.39 1620 6.45 2.52 0.39 1709 6.30 2.46 0.39 1762 6.10 2.38 0.39 185128 26 6.90 1.86 0.27 1709 6.70 1.81 0.27 1798 6.60 1.78 0.27 1851 6.40 1.73 0.27 190529 18 5.88 4.64 0.79 1424 5.63 4.44 0.79 1495 5.40 4.27 0.79 1566 5.20 4.11 0.79 163829 20 6.13 4.10 0.67 1495 5.88 3.94 0.67 1584 5.70 3.82 0.67 1620 5.50 3.69 0.67 169129 22 6.38 3.51 0.55 1549 6.15 3.38 0.55 1647 6.00 3.30 0.55 1691 5.75 3.16 0.55 176229 24 6.70 2.88 0.43 1620 6.45 2.77 0.43 1709 6.30 2.71 0.43 1762 6.10 2.62 0.43 185129 26 6.90 2.14 0.31 1709 6.70 2.08 0.31 1798 6.60 2.05 0.31 1851 6.40 1.98 0.31 190530 18 5.88 4.88 0.83 1424 5.63 4.67 0.83 1495 5.40 4.48 0.83 1566 5.20 4.32 0.83 163830 20 6.13 4.35 0.71 1495 5.88 4.17 0.71 1584 5.70 4.05 0.71 1620 5.50 3.91 0.71 169130 22 6.38 3.76 0.59 1549 6.15 3.63 0.59 1647 6.00 3.54 0.59 1691 5.75 3.39 0.59 176230 24 6.70 3.15 0.47 1620 6.45 3.03 0.47 1709 6.30 2.96 0.47 1762 6.10 2.87 0.47 185130 26 6.90 2.42 0.35 1709 6.70 2.35 0.35 1798 6.60 2.31 0.35 1851 6.40 2.24 0.35 190531 18 5.88 5.11 0.87 1424 5.63 4.89 0.87 1495 5.40 4.70 0.87 1566 5.20 4.52 0.87 163831 20 6.13 4.59 0.75 1495 5.88 4.41 0.75 1584 5.70 4.28 0.75 1620 5.50 4.13 0.75 169131 22 6.38 4.02 0.63 1549 6.15 3.87 0.63 1647 6.00 3.78 0.63 1691 5.75 3.62 0.63 176231 24 6.70 3.42 0.51 1620 6.45 3.29 0.51 1709 6.30 3.21 0.51 1762 6.10 3.11 0.51 185131 26 6.90 2.69 0.39 1709 6.70 2.61 0.39 1798 6.60 2.57 0.39 1851 6.40 2.50 0.39 190532 18 5.88 5.35 0.91 1424 5.63 5.12 0.91 1495 5.40 4.91 0.91 1566 5.20 4.73 0.91 163832 20 6.13 4.84 0.79 1495 5.88 4.64 0.79 1584 5.70 4.50 0.79 1620 5.50 4.35 0.79 169132 22 6.38 4.27 0.67 1549 6.15 4.12 0.67 1647 6.00 4.02 0.67 1691 5.75 3.85 0.67 176232 24 6.70 3.69 0.55 1620 6.45 3.55 0.55 1709 6.30 3.47 0.55 1762 6.10 3.36 0.55 185132 26 6.90 2.97 0.43 1709 6.70 2.88 0.43 1798 6.60 2.84 0.43 1851 6.40 2.75 0.43 1905
INTERNOBS (°C)
INTERNOBU (°C)
ESTERNO BS (°C)21 2725 30
Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT
POTENZIALITA’: 5,0 kW RAPPORTO S/T: 0,65 POTENZA ASSORBITA: 1780 W
Funzionamento in RAFFREDDAMENTO (230 V)
NOTE Q: Potenzialità totale (kW) SHF: Rapporto sensibile/totale BS: A bulbo seccoSHC: Potenzialità sensibile (kW) INPUT: Potenza assorbita (W) BU: A bulbo umido
26
21 18 4.90 2.30 0.47 1744 4.50 2.12 0.47 1851 4.33 2.03 0.47 188721 20 5.15 1.80 0.35 1816 4.80 1.68 0.35 1905 4.63 1.62 0.35 195822 18 4.90 2.50 0.51 1744 4.50 2.30 0.51 1851 4.33 2.21 0.51 188722 20 5.15 2.01 0.39 1816 4.80 1.87 0.39 1905 4.63 1.80 0.39 195822 22 5.45 1.47 0.27 1887 5.10 1.38 0.27 1994 4.93 1.33 0.27 202923 18 4.90 2.70 0.55 1744 4.50 2.48 0.55 1851 4.33 2.38 0.55 188723 20 5.15 2.21 0.43 1816 4.80 2.06 0.43 1905 4.63 1.99 0.43 195823 22 5.45 1.69 0.31 1887 5.10 1.58 0.31 1994 4.93 1.53 0.31 202924 18 4.90 2.89 0.59 1744 4.50 2.66 0.59 1851 4.33 2.55 0.59 188724 20 5.15 2.42 0.47 1816 4.80 2.26 0.47 1905 4.63 2.17 0.47 195824 22 5.45 1.91 0.35 1887 5.10 1.79 0.35 1994 4.93 1.72 0.35 202924 24 5.75 1.32 0.23 1958 5.40 1.24 0.23 2047 5.25 1.21 0.23 209225 18 4.90 3.09 0.63 1744 4.50 2.84 0.63 1851 4.33 2.72 0.63 188725 20 5.15 2.63 0.51 1816 4.80 2.45 0.51 1905 4.63 2.36 0.51 195825 22 5.45 2.13 0.39 1887 5.10 1.99 0.39 1994 4.93 1.92 0.39 202925 24 5.75 1.55 0.27 1958 5.40 1.46 0.27 2047 5.25 1.42 0.27 209226 18 4.90 3.28 0.67 1744 4.50 3.02 0.67 1851 4.33 2.90 0.67 188726 20 5.15 2.83 0.55 1816 4.80 2.64 0.55 1905 4.63 2.54 0.55 195826 22 5.45 2.34 0.43 1887 5.10 2.19 0.43 1994 4.93 2.12 0.43 202926 24 5.75 1.78 0.31 1958 5.40 1.67 0.31 2047 5.25 1.63 0.31 209226 26 6.05 1.15 0.19 2029 5.70 1.08 0.19 2118 5.53 1.05 0.19 216327 18 4.90 3.48 0.71 1744 4.50 3.20 0.71 1851 4.33 3.07 0.71 188727 20 5.15 3.04 0.59 1816 4.80 2.83 0.59 1905 4.63 2.73 0.59 195827 22 5.45 2.56 0.47 1887 5.10 2.40 0.47 1994 4.93 2.31 0.47 202927 24 5.75 2.01 0.35 1958 5.40 1.89 0.35 2047 5.25 1.84 0.35 209227 26 6.05 1.39 0.23 2029 5.70 1.31 0.23 2118 5.53 1.27 0.23 216328 18 4.90 3.68 0.75 1744 4.50 3.38 0.75 1851 4.33 3.24 0.75 188728 20 5.15 3.24 0.63 1816 4.80 3.02 0.63 1905 4.63 2.91 0.63 195828 22 5.45 2.78 0.51 1887 5.10 2.60 0.51 1994 4.93 2.51 0.51 202928 24 5.75 2.24 0.39 1958 5.40 2.11 0.39 2047 5.25 2.05 0.39 209228 26 6.05 1.63 0.27 2029 5.70 1.54 0.27 2118 5.53 1.49 0.27 216329 18 4.90 3.87 0.79 1744 4.50 3.56 0.79 1851 4.33 3.42 0.79 188729 20 5.15 3.45 0.67 1816 4.80 3.22 0.67 1905 4.63 3.10 0.67 195829 22 5.45 3.00 0.55 1887 5.10 2.81 0.55 1994 4.93 2.71 0.55 202929 24 5.75 2.47 0.43 1958 5.40 2.32 0.43 2047 5.25 2.26 0.43 209229 26 6.05 1.88 0.31 2029 5.70 1.77 0.31 2118 5.53 1.71 0.31 216330 18 4.90 4.07 0.83 1744 4.50 3.74 0.83 1851 4.33 3.59 0.83 188730 20 5.15 3.66 0.71 1816 4.80 3.41 0.71 1905 4.63 3.28 0.71 195830 22 5.45 3.22 0.59 1887 5.10 3.01 0.59 1994 4.93 2.91 0.59 202930 24 5.75 2.70 0.47 1958 5.40 2.54 0.47 2047 5.25 2.47 0.47 209230 26 6.05 2.12 0.35 2029 5.70 2.00 0.35 2118 5.53 1.93 0.35 216331 18 4.90 4.26 0.87 1744 4.50 3.92 0.87 1851 4.33 3.76 0.87 188731 20 5.15 3.86 0.75 1816 4.80 3.60 0.75 1905 4.63 3.47 0.75 195831 22 5.45 3.43 0.63 1887 5.10 3.21 0.63 1994 4.93 3.10 0.63 202931 24 5.75 2.93 0.51 1958 5.40 2.75 0.51 2047 5.25 2.68 0.51 209231 26 6.05 2.36 0.39 2029 5.70 2.22 0.39 2118 5.53 2.15 0.39 216332 18 4.90 4.46 0.91 1744 4.50 4.10 0.91 1851 4.33 3.94 0.91 188732 20 5.15 4.07 0.79 1816 4.80 3.79 0.79 1905 4.63 3.65 0.79 195832 22 5.45 3.65 0.67 1887 5.10 3.42 0.67 1994 4.93 3.30 0.67 202932 24 5.75 3.16 0.55 1958 5.40 2.97 0.55 2047 5.25 2.89 0.55 209232 26 6.05 2.60 0.43 2029 5.70 2.45 0.43 2118 5.53 2.38 0.43 2163
35 4340Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT
MSH-GA50VB - : MUH-GA50VB - (230V)E1E1
Funzionamento in RAFFREDDAMENTO (230 V)
INTERNOBS (°C)
INTERNOBU (°C)
ESTERNO BS (°C)POTENZIALITA’: 5,0 kW RAPPORTO S/T: 0,65 POTENZA ASSORBITA: 1780 W
NOTE Q: Potenzialità totale (kW) SHF: Rapporto sensibile/totale BS: A bulbo seccoSHC: Potenzialità sensibile (kW) INPUT: Potenza assorbita (W) BU: A bulbo umido
27
MSH-GA60VB - : MUH-GA60VB - (230V)E1E1
21 18 7.40 3.41 0.46 1928 7.09 3.26 0.46 2024 6.80 3.13 0.46 2121 6.55 3.01 0.46 221721 20 7.72 2.62 0.34 2024 7.40 2.52 0.34 2145 7.18 2.44 0.34 2193 6.93 2.36 0.34 229022 18 7.40 3.70 0.50 1928 7.09 3.54 0.50 2024 6.80 3.40 0.50 2121 6.55 3.28 0.50 221722 20 7.72 2.93 0.38 2024 7.40 2.81 0.38 2145 7.18 2.73 0.38 2193 6.93 2.63 0.38 229022 22 8.03 2.09 0.26 2097 7.75 2.01 0.26 2229 7.56 1.97 0.26 2290 7.25 1.88 0.26 238623 18 7.40 4.00 0.54 1928 7.09 3.83 0.54 2024 6.80 3.67 0.54 2121 6.55 3.54 0.54 221723 20 7.72 3.24 0.42 2024 7.40 3.11 0.42 2145 7.18 3.02 0.42 2193 6.93 2.91 0.42 229023 22 8.03 2.41 0.30 2097 7.75 2.32 0.30 2229 7.56 2.27 0.30 2290 7.25 2.17 0.30 238624 18 7.40 4.29 0.58 1928 7.09 4.11 0.58 2024 6.80 3.95 0.58 2121 6.55 3.80 0.58 221724 20 7.72 3.55 0.46 2024 7.40 3.41 0.46 2145 7.18 3.30 0.46 2193 6.93 3.19 0.46 229024 22 8.03 2.73 0.34 2097 7.75 2.63 0.34 2229 7.56 2.57 0.34 2290 7.25 2.46 0.34 238624 24 8.44 1.86 0.22 2193 8.13 1.79 0.22 2314 7.94 1.75 0.22 2386 7.69 1.69 0.22 250625 18 7.40 4.59 0.62 1928 7.09 4.39 0.62 2024 6.80 4.22 0.62 2121 6.55 4.06 0.62 221725 20 7.72 3.86 0.50 2024 7.40 3.70 0.50 2145 7.18 3.59 0.50 2193 6.93 3.47 0.50 229025 22 8.03 3.05 0.38 2097 7.75 2.94 0.38 2229 7.56 2.87 0.38 2290 7.25 2.75 0.38 238625 24 8.44 2.19 0.26 2193 8.13 2.11 0.26 2314 7.94 2.06 0.26 2386 7.69 2.00 0.26 250626 18 7.40 4.89 0.66 1928 7.09 4.68 0.66 2024 6.80 4.49 0.66 2121 6.55 4.32 0.66 221726 20 7.72 4.17 0.54 2024 7.40 4.00 0.54 2145 7.18 3.88 0.54 2193 6.93 3.74 0.54 229026 22 8.03 3.37 0.42 2097 7.75 3.25 0.42 2229 7.56 3.18 0.42 2290 7.25 3.04 0.42 238626 24 8.44 2.53 0.30 2193 8.13 2.44 0.30 2314 7.94 2.38 0.30 2386 7.69 2.31 0.30 250626 26 8.69 1.56 0.18 2314 8.44 1.52 0.18 2434 8.32 1.50 0.18 2506 8.06 1.45 0.18 257927 18 7.40 5.18 0.70 1928 7.09 4.96 0.70 2024 6.80 4.76 0.70 2121 6.55 4.59 0.70 221727 20 7.72 4.48 0.58 2024 7.40 4.29 0.58 2145 7.18 4.17 0.58 2193 6.93 4.02 0.58 229027 22 8.03 3.69 0.46 2097 7.75 3.56 0.46 2229 7.56 3.48 0.46 2290 7.25 3.33 0.46 238627 24 8.44 2.87 0.34 2193 8.13 2.76 0.34 2314 7.94 2.70 0.34 2386 7.69 2.61 0.34 250627 26 8.69 1.91 0.22 2314 8.44 1.86 0.22 2434 8.32 1.83 0.22 2506 8.06 1.77 0.22 257928 18 7.40 5.48 0.74 1928 7.09 5.24 0.74 2024 6.80 5.03 0.74 2121 6.55 4.85 0.74 221728 20 7.72 4.78 0.62 2024 7.40 4.59 0.62 2145 7.18 4.45 0.62 2193 6.93 4.30 0.62 229028 22 8.03 4.02 0.50 2097 7.75 3.87 0.50 2229 7.56 3.78 0.50 2290 7.25 3.62 0.50 238628 24 8.44 3.21 0.38 2193 8.13 3.09 0.38 2314 7.94 3.02 0.38 2386 7.69 2.92 0.38 250628 26 8.69 2.26 0.26 2314 8.44 2.19 0.26 2434 8.32 2.16 0.26 2506 8.06 2.10 0.26 257929 18 7.40 5.77 0.78 1928 7.09 5.53 0.78 2024 6.80 5.31 0.78 2121 6.55 5.11 0.78 221729 20 7.72 5.09 0.66 2024 7.40 4.89 0.66 2145 7.18 4.74 0.66 2193 6.93 4.57 0.66 229029 22 8.03 4.34 0.54 2097 7.75 4.18 0.54 2229 7.56 4.08 0.54 2290 7.25 3.91 0.54 238629 24 8.44 3.55 0.42 2193 8.13 3.41 0.42 2314 7.94 3.33 0.42 2386 7.69 3.23 0.42 250629 26 8.69 2.61 0.30 2314 8.44 2.53 0.30 2434 8.32 2.49 0.30 2506 8.06 2.42 0.30 257930 18 7.40 6.07 0.82 1928 7.09 5.81 0.82 2024 6.80 5.58 0.82 2121 6.55 5.37 0.82 221730 20 7.72 5.40 0.70 2024 7.40 5.18 0.70 2145 7.18 5.03 0.70 2193 6.93 4.85 0.70 229030 22 8.03 4.66 0.58 2097 7.75 4.49 0.58 2229 7.56 4.38 0.58 2290 7.25 4.20 0.58 238630 24 8.44 3.88 0.46 2193 8.13 3.74 0.46 2314 7.94 3.65 0.46 2386 7.69 3.54 0.46 250630 26 8.69 2.96 0.34 2314 8.44 2.87 0.34 2434 8.32 2.83 0.34 2506 8.06 2.74 0.34 257931 18 7.40 6.37 0.86 1928 7.09 6.10 0.86 2024 6.80 5.85 0.86 2121 6.55 5.63 0.86 221731 20 7.72 5.71 0.74 2024 7.40 5.48 0.74 2145 7.18 5.31 0.74 2193 6.93 5.13 0.74 229031 22 8.03 4.98 0.62 2097 7.75 4.80 0.62 2229 7.56 4.69 0.62 2290 7.25 4.49 0.62 238631 24 8.44 4.22 0.50 2193 8.13 4.06 0.50 2314 7.94 3.97 0.50 2386 7.69 3.84 0.50 250631 26 8.69 3.30 0.38 2314 8.44 3.21 0.38 2434 8.32 3.16 0.38 2506 8.06 3.06 0.38 257932 18 7.40 6.66 0.90 1928 7.09 6.38 0.90 2024 6.80 6.12 0.90 2121 6.55 5.90 0.90 221732 20 7.72 6.02 0.78 2024 7.40 5.77 0.78 2145 7.18 5.60 0.78 2193 6.93 5.41 0.78 229032 22 8.03 5.30 0.66 2097 7.75 5.11 0.66 2229 7.56 4.99 0.66 2290 7.25 4.78 0.66 238632 24 8.44 4.56 0.54 2193 8.13 4.39 0.54 2314 7.94 4.29 0.54 2386 7.69 4.15 0.54 250632 26 8.69 3.65 0.42 2314 8.44 3.55 0.42 2434 8.32 3.49 0.42 2506 8.06 3.39 0.42 2579
21 2725 30Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT
Funzionamento in RAFFREDDAMENTO (230 V)
INTERNOBS (°C)
INTERNOBU (°C)
ESTERNO BS (°C)POTENZIALITA’: 6,3 kW RAPPORTO S/T: 0,64 POTENZA ASSORBITA: 1780 W
NOTE Q: Potenzialità totale (kW) SHF: Rapporto sensibile/totale BS: A bulbo seccoSHC: Potenzialità sensibile (kW) INPUT: Potenza assorbita (W) BU: A bulbo umido
28
21 18 6.17 2.84 0.46 2362 5.67 2.61 0.46 2506 5.45 2.51 0.46 255521 20 6.49 2.21 0.34 2458 6.05 2.06 0.34 2579 5.83 1.98 0.34 265122 18 6.17 3.09 0.50 2362 5.67 2.84 0.50 2506 5.45 2.72 0.50 255522 20 6.49 2.47 0.38 2458 6.05 2.30 0.38 2579 5.83 2.21 0.38 265122 22 6.87 1.79 0.26 2555 6.43 1.67 0.26 2699 6.21 1.61 0.26 274723 18 6.17 3.33 0.54 2362 5.67 3.06 0.54 2506 5.45 2.94 0.54 255523 20 6.49 2.73 0.42 2458 6.05 2.54 0.42 2579 5.83 2.45 0.42 265123 22 6.87 2.06 0.30 2555 6.43 1.93 0.30 2699 6.21 1.86 0.30 274724 18 6.17 3.58 0.58 2362 5.67 3.29 0.58 2506 5.45 3.16 0.58 255524 20 6.49 2.98 0.46 2458 6.05 2.78 0.46 2579 5.83 2.68 0.46 265124 22 6.87 2.33 0.34 2555 6.43 2.18 0.34 2699 6.21 2.11 0.34 274724 24 7.25 1.59 0.22 2651 6.80 1.50 0.22 2772 6.62 1.46 0.22 283225 18 6.17 3.83 0.62 2362 5.67 3.52 0.62 2506 5.45 3.38 0.62 255525 20 6.49 3.24 0.50 2458 6.05 3.02 0.50 2579 5.83 2.91 0.50 265125 22 6.87 2.61 0.38 2555 6.43 2.44 0.38 2699 6.21 2.36 0.38 274725 24 7.25 1.88 0.26 2651 6.80 1.77 0.26 2772 6.62 1.72 0.26 283226 18 6.17 4.07 0.66 2362 5.67 3.74 0.66 2506 5.45 3.60 0.66 255526 20 6.49 3.50 0.54 2458 6.05 3.27 0.54 2579 5.83 3.15 0.54 265126 22 6.87 2.88 0.42 2555 6.43 2.70 0.42 2699 6.21 2.61 0.42 274726 24 7.25 2.17 0.30 2651 6.80 2.04 0.30 2772 6.62 1.98 0.30 283226 26 7.62 1.37 0.18 2747 7.18 1.29 0.18 2868 6.96 1.25 0.18 292827 18 6.17 4.32 0.70 2362 5.67 3.97 0.70 2506 5.45 3.81 0.70 255527 20 6.49 3.76 0.58 2458 6.05 3.51 0.58 2579 5.83 3.38 0.58 265127 22 6.87 3.16 0.46 2555 6.43 2.96 0.46 2699 6.21 2.85 0.46 274727 24 7.25 2.46 0.34 2651 6.80 2.31 0.34 2772 6.62 2.25 0.34 283227 26 7.62 1.68 0.22 2747 7.18 1.58 0.22 2868 6.96 1.53 0.22 292828 18 6.17 4.57 0.74 2362 5.67 4.20 0.74 2506 5.45 4.03 0.74 255528 20 6.49 4.02 0.62 2458 6.05 3.75 0.62 2579 5.83 3.61 0.62 265128 22 6.87 3.43 0.50 2555 6.43 3.21 0.50 2699 6.21 3.10 0.50 274728 24 7.25 2.75 0.38 2651 6.80 2.59 0.38 2772 6.62 2.51 0.38 283228 26 7.62 1.98 0.26 2747 7.18 1.87 0.26 2868 6.96 1.81 0.26 292829 18 6.17 4.82 0.78 2362 5.67 4.42 0.78 2506 5.45 4.25 0.78 255529 20 6.49 4.28 0.66 2458 6.05 3.99 0.66 2579 5.83 3.85 0.66 265129 22 6.87 3.71 0.54 2555 6.43 3.47 0.54 2699 6.21 3.35 0.54 274729 24 7.25 3.04 0.42 2651 6.80 2.86 0.42 2772 6.62 2.78 0.42 283229 26 7.62 2.29 0.30 2747 7.18 2.15 0.30 2868 6.96 2.09 0.30 292830 18 6.17 5.06 0.82 2362 5.67 4.65 0.82 2506 5.45 4.47 0.82 255530 20 6.49 4.54 0.70 2458 6.05 4.23 0.70 2579 5.83 4.08 0.70 265130 22 6.87 3.98 0.58 2555 6.43 3.73 0.58 2699 6.21 3.60 0.58 274730 24 7.25 3.33 0.46 2651 6.80 3.13 0.46 2772 6.62 3.04 0.46 283230 26 7.62 2.59 0.34 2747 7.18 2.44 0.34 2868 6.96 2.37 0.34 292831 18 6.17 5.31 0.86 2362 5.67 4.88 0.86 2506 5.45 4.69 0.86 255531 20 6.49 4.80 0.74 2458 6.05 4.48 0.74 2579 5.83 4.31 0.74 265131 22 6.87 4.26 0.62 2555 6.43 3.98 0.62 2699 6.21 3.85 0.62 274731 24 7.25 3.62 0.50 2651 6.80 3.40 0.50 2772 6.62 3.31 0.50 283231 26 7.62 2.90 0.38 2747 7.18 2.73 0.38 2868 6.96 2.65 0.38 292832 18 6.17 5.56 0.90 2362 5.67 5.10 0.90 2506 5.45 4.90 0.90 255532 20 6.49 5.06 0.78 2458 6.05 4.72 0.78 2579 5.83 4.55 0.78 265132 22 6.87 4.53 0.66 2555 6.43 4.24 0.66 2699 6.21 4.10 0.66 274732 24 7.25 3.91 0.54 2651 6.80 3.67 0.54 2772 6.62 3.57 0.54 283232 26 7.62 3.20 0.42 2747 7.18 3.02 0.42 2868 6.96 2.92 0.42 2928
35 4340Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT
MSH-GA60VB - : MUH-GA60VB - (230V)E1E1
Funzionamento in RAFFREDDAMENTO (230 V)
INTERNOBS (°C)
INTERNOBU (°C)
ESTERNO BS (°C)POTENZIALITA’: 6,3 kW RAPPORTO S/T: 0,64 POTENZA ASSORBITA: 2410 W
NOTE Q: Potenzialità totale (kW) SHF: Rapporto sensibile/totale BS: A bulbo seccoSHC: Potenzialità sensibile (kW) INPUT: Potenza assorbita (W) BU: A bulbo umido
29
21 18 9.99 4.39 0.44 2608 9.56 4.21 0.44 2738 9.18 4.04 0.44 2869 8.84 3.89 0.44 299921 20 10.41 3.33 0.32 2738 9.99 3.20 0.32 2901 9.69 3.10 0.32 2967 9.35 2.99 0.32 309722 18 9.99 4.79 0.48 2608 9.56 4.59 0.48 2738 9.18 4.41 0.48 2869 8.84 4.24 0.48 299922 20 10.41 3.75 0.36 2738 9.99 3.60 0.36 2901 9.69 3.49 0.36 2967 9.35 3.37 0.36 309722 22 10.84 2.60 0.24 2836 10.46 2.51 0.24 3016 10.20 2.45 0.24 3097 9.78 2.35 0.24 322723 18 9.99 5.19 0.52 2608 9.56 4.97 0.52 2738 9.18 4.77 0.52 2869 8.84 4.60 0.52 299923 20 10.41 4.17 0.40 2738 9.99 4.00 0.40 2901 9.69 3.88 0.40 2967 9.35 3.74 0.40 309723 22 10.84 3.03 0.28 2836 10.46 2.93 0.28 3016 10.20 2.86 0.28 3097 9.78 2.74 0.28 322724 18 9.99 5.59 0.56 2608 9.56 5.36 0.56 2738 9.18 5.14 0.56 2869 8.84 4.95 0.56 299924 20 10.41 4.58 0.44 2738 9.99 4.39 0.44 2901 9.69 4.26 0.44 2967 9.35 4.11 0.44 309724 22 10.84 3.47 0.32 2836 10.46 3.35 0.32 3016 10.20 3.26 0.32 3097 9.78 3.13 0.32 322724 24 11.39 2.28 0.20 2967 10.97 2.19 0.20 3130 10.71 2.14 0.20 3227 10.37 2.07 0.20 339025 18 9.99 5.99 0.60 2608 9.56 5.74 0.60 2738 9.18 5.51 0.60 2869 8.84 5.30 0.60 299925 20 10.41 5.00 0.48 2738 9.99 4.79 0.48 2901 9.69 4.65 0.48 2967 9.35 4.49 0.48 309725 22 10.84 3.90 0.36 2836 10.46 3.76 0.36 3016 10.20 3.67 0.36 3097 9.78 3.52 0.36 322725 24 11.39 2.73 0.24 2967 10.97 2.63 0.24 3130 10.71 2.57 0.24 3227 10.37 2.49 0.24 339026 18 9.99 6.39 0.64 2608 9.56 6.12 0.64 2738 9.18 5.88 0.64 2869 8.84 5.66 0.64 299926 20 10.41 5.41 0.52 2738 9.99 5.19 0.52 2901 9.69 5.04 0.52 2967 9.35 4.86 0.52 309726 22 10.84 4.34 0.40 2836 10.46 4.18 0.40 3016 10.20 4.08 0.40 3097 9.78 3.91 0.40 322726 24 11.39 3.19 0.28 2967 10.97 3.07 0.28 3130 10.71 3.00 0.28 3227 10.37 2.90 0.28 339026 26 11.73 1.88 0.16 3130 11.39 1.82 0.16 3293 11.22 1.80 0.16 3390 10.88 1.74 0.16 348827 18 9.99 6.79 0.68 2608 9.56 6.50 0.68 2738 9.18 6.24 0.68 2869 8.84 6.01 0.68 299927 20 10.41 5.83 0.56 2738 9.99 5.59 0.56 2901 9.69 5.43 0.56 2967 9.35 5.24 0.56 309727 22 10.84 4.77 0.44 2836 10.46 4.60 0.44 3016 10.20 4.49 0.44 3097 9.78 4.30 0.44 322727 24 11.39 3.64 0.32 2967 10.97 3.51 0.32 3130 10.71 3.43 0.32 3227 10.37 3.32 0.32 339027 26 11.73 2.35 0.20 3130 11.39 2.28 0.20 3293 11.22 2.24 0.20 3390 10.88 2.18 0.20 348828 18 9.99 7.19 0.72 2608 9.56 6.89 0.72 2738 9.18 6.61 0.72 2869 8.84 6.36 0.72 299928 20 10.41 6.25 0.60 2738 9.99 5.99 0.60 2901 9.69 5.81 0.60 2967 9.35 5.61 0.60 309728 22 10.84 5.20 0.48 2836 10.46 5.02 0.48 3016 10.20 4.90 0.48 3097 9.78 4.69 0.48 322728 24 11.39 4.10 0.36 2967 10.97 3.95 0.36 3130 10.71 3.86 0.36 3227 10.37 3.73 0.36 339028 26 11.73 2.82 0.24 3130 11.39 2.73 0.24 3293 11.22 2.69 0.24 3390 10.88 2.61 0.24 348829 18 9.99 7.59 0.76 2608 9.56 7.27 0.76 2738 9.18 6.98 0.76 2869 8.84 6.72 0.76 299929 20 10.41 6.66 0.64 2738 9.99 6.39 0.64 2901 9.69 6.20 0.64 2967 9.35 5.98 0.64 309729 22 10.84 5.64 0.52 2836 10.46 5.44 0.52 3016 10.20 5.30 0.52 3097 9.78 5.08 0.52 322729 24 11.39 4.56 0.40 2967 10.97 4.39 0.40 3130 10.71 4.28 0.40 3227 10.37 4.15 0.40 339029 26 11.73 3.28 0.28 3130 11.39 3.19 0.28 3293 11.22 3.14 0.28 3390 10.88 3.05 0.28 348830 18 9.99 7.99 0.80 2608 9.56 7.65 0.80 2738 9.18 7.34 0.80 2869 8.84 7.07 0.80 299930 20 10.41 7.08 0.68 2738 9.99 6.79 0.68 2901 9.69 6.59 0.68 2967 9.35 6.36 0.68 309730 22 10.84 6.07 0.56 2836 10.46 5.85 0.56 3016 10.20 5.71 0.56 3097 9.78 5.47 0.56 322730 24 11.39 5.01 0.44 2967 10.97 4.82 0.44 3130 10.71 4.71 0.44 3227 10.37 4.56 0.44 339030 26 11.73 3.75 0.32 3130 11.39 3.64 0.32 3293 11.22 3.59 0.32 3390 10.88 3.48 0.32 348831 18 9.99 8.39 0.84 2608 9.56 8.03 0.84 2738 9.18 7.71 0.84 2869 8.84 7.43 0.84 299931 20 10.41 7.50 0.72 2738 9.99 7.19 0.72 2901 9.69 6.98 0.72 2967 9.35 6.73 0.72 309731 22 10.84 6.50 0.60 2836 10.46 6.27 0.60 3016 10.20 6.12 0.60 3097 9.78 5.87 0.60 322731 24 11.39 5.47 0.48 2967 10.97 5.26 0.48 3130 10.71 5.14 0.48 3227 10.37 4.98 0.48 339031 26 11.73 4.22 0.36 3130 11.39 4.10 0.36 3293 11.22 4.04 0.36 3390 10.88 3.92 0.36 348832 18 9.99 8.79 0.88 2608 9.56 8.42 0.88 2738 9.18 8.08 0.88 2869 8.84 7.78 0.88 299932 20 10.41 7.91 0.76 2738 9.99 7.59 0.76 2901 9.69 7.36 0.76 2967 9.35 7.11 0.76 309732 22 10.84 6.94 0.64 2836 10.46 6.69 0.64 3016 10.20 6.53 0.64 3097 9.78 6.26 0.64 322732 24 11.39 5.92 0.52 2967 10.97 5.70 0.52 3130 10.71 5.57 0.52 3227 10.37 5.39 0.52 339032 26 11.73 4.69 0.40 3130 11.39 4.56 0.40 3293 11.22 4.49 0.40 3390 10.88 4.35 0.40 3488
21 2725 30Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT
MSH-GA80VB - : MUH-GA80VB - (230V)E1E1
Funzionamento in RAFFREDDAMENTO (230 V)
INTERNOBS (°C)
INTERNOBU (°C)
ESTERNO BS (°C)POTENZIALITA’: 8,5 kW RAPPORTO S/T: 0,62 POTENZA ASSORBITA: 3260 W
NOTE Q: Potenzialità totale (kW) SHF: Rapporto sensibile/totale BS: A bulbo seccoSHC: Potenzialità sensibile (kW) INPUT: Potenza assorbita (W) BU: A bulbo umido
30
21 18 8.33 3.67 0.44 3195 7.65 3.37 0.44 3390 7.35 3.24 0.44 345621 20 8.76 2.80 0.32 3325 8.16 2.61 0.32 3488 7.86 2.52 0.32 358622 18 8.33 4.00 0.48 3195 7.65 3.67 0.48 3390 7.35 3.53 0.48 345622 20 8.76 3.15 0.36 3325 8.16 2.94 0.36 3488 7.86 2.83 0.36 358622 22 9.27 2.22 0.24 3456 8.67 2.08 0.24 3651 8.37 2.01 0.24 371623 18 8.33 4.33 0.52 3195 7.65 3.98 0.52 3390 7.35 3.82 0.52 345623 20 8.76 3.50 0.40 3325 8.16 3.26 0.40 3488 7.86 3.15 0.40 358623 22 9.27 2.59 0.28 3456 8.67 2.43 0.28 3651 8.37 2.34 0.28 371624 18 8.33 4.66 0.56 3195 7.65 4.28 0.56 3390 7.35 4.12 0.56 345624 20 8.76 3.85 0.44 3325 8.16 3.59 0.44 3488 7.86 3.46 0.44 358624 22 9.27 2.96 0.32 3456 8.67 2.77 0.32 3651 8.37 2.68 0.32 371624 24 9.78 1.96 0.20 3586 9.18 1.84 0.20 3749 8.93 1.79 0.20 383125 18 8.33 5.00 0.60 3195 7.65 4.59 0.60 3390 7.35 4.41 0.60 345625 20 8.76 4.20 0.48 3325 8.16 3.92 0.48 3488 7.86 3.77 0.48 358625 22 9.27 3.34 0.36 3456 8.67 3.12 0.36 3651 8.37 3.01 0.36 371625 24 9.78 2.35 0.24 3586 9.18 2.20 0.24 3749 8.93 2.14 0.24 383126 18 8.33 5.33 0.64 3195 7.65 4.90 0.64 3390 7.35 4.71 0.64 345626 20 8.76 4.55 0.52 3325 8.16 4.24 0.52 3488 7.86 4.09 0.52 358626 22 9.27 3.71 0.40 3456 8.67 3.47 0.40 3651 8.37 3.35 0.40 371626 24 9.78 2.74 0.28 3586 9.18 2.57 0.28 3749 8.93 2.50 0.28 383126 26 10.29 1.65 0.16 3716 9.69 1.55 0.16 3879 9.39 1.50 0.16 396127 18 8.33 5.66 0.68 3195 7.65 5.20 0.68 3390 7.35 5.00 0.68 345627 20 8.76 4.90 0.56 3325 8.16 4.57 0.56 3488 7.86 4.40 0.56 358627 22 9.27 4.08 0.44 3456 8.67 3.81 0.44 3651 8.37 3.68 0.44 371627 24 9.78 3.13 0.32 3586 9.18 2.94 0.32 3749 8.93 2.86 0.32 383127 26 10.29 2.06 0.20 3716 9.69 1.94 0.20 3879 9.39 1.88 0.20 396128 18 8.33 6.00 0.72 3195 7.65 5.51 0.72 3390 7.35 5.29 0.72 345628 20 8.76 5.25 0.60 3325 8.16 4.90 0.60 3488 7.86 4.72 0.60 358628 22 9.27 4.45 0.48 3456 8.67 4.16 0.48 3651 8.37 4.02 0.48 371628 24 9.78 3.52 0.36 3586 9.18 3.30 0.36 3749 8.93 3.21 0.36 383128 26 10.29 2.47 0.24 3716 9.69 2.33 0.24 3879 9.39 2.25 0.24 396129 18 8.33 6.33 0.76 3195 7.65 5.81 0.76 3390 7.35 5.59 0.76 345629 20 8.76 5.60 0.64 3325 8.16 5.22 0.64 3488 7.86 5.03 0.64 358629 22 9.27 4.82 0.52 3456 8.67 4.51 0.52 3651 8.37 4.35 0.52 371629 24 9.78 3.91 0.40 3586 9.18 3.67 0.40 3749 8.93 3.57 0.40 383129 26 10.29 2.88 0.28 3716 9.69 2.71 0.28 3879 9.39 2.63 0.28 396130 18 8.33 6.66 0.80 3195 7.65 6.12 0.80 3390 7.35 5.88 0.80 345630 20 8.76 5.95 0.68 3325 8.16 5.55 0.68 3488 7.86 5.35 0.68 358630 22 9.27 5.19 0.56 3456 8.67 4.86 0.56 3651 8.37 4.69 0.56 371630 24 9.78 4.30 0.44 3586 9.18 4.04 0.44 3749 8.93 3.93 0.44 383130 26 10.29 3.29 0.32 3716 9.69 3.10 0.32 3879 9.39 3.01 0.32 396131 18 8.33 7.00 0.84 3195 7.65 6.43 0.84 3390 7.35 6.18 0.84 345631 20 8.76 6.30 0.72 3325 8.16 5.88 0.72 3488 7.86 5.66 0.72 358631 22 9.27 5.56 0.60 3456 8.67 5.20 0.60 3651 8.37 5.02 0.60 371631 24 9.78 4.69 0.48 3586 9.18 4.41 0.48 3749 8.93 4.28 0.48 383131 26 10.29 3.70 0.36 3716 9.69 3.49 0.36 3879 9.39 3.38 0.36 396132 18 8.33 7.33 0.88 3195 7.65 6.73 0.88 3390 7.35 6.47 0.88 345632 20 8.76 6.65 0.76 3325 8.16 6.20 0.76 3488 7.86 5.98 0.76 358632 22 9.27 5.93 0.64 3456 8.67 5.55 0.64 3651 8.37 5.36 0.64 371632 24 9.78 5.08 0.52 3586 9.18 4.77 0.52 3749 8.93 4.64 0.52 383132 26 10.29 4.11 0.40 3716 9.69 3.88 0.40 3879 9.39 3.76 0.40 3961
35 4340Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT
MSH-GA80VB - : MUH-GA80VB - (230V)E1E1
Funzionamento in RAFFREDDAMENTO (230 V)
INTERNOBS (°C)
INTERNOBU (°C)
ESTERNO BS (°C)POTENZIALITA’: 8,5 kW RAPPORTO S/T: 0,62 POTENZA ASSORBITA: 3260 W
NOTE Q: Potenzialità totale (kW) SHF: Rapporto sensibile/totale BS: A bulbo seccoSHC: Potenzialità sensibile (kW) INPUT: Potenza assorbita (W) BU: A bulbo umido
31
ESTERNO BU (°C)INTERNOBS (°C)
-10 -5 0 5 10 15 20Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
POTENZIALITA’: 5,2 kW POTENZA ASSORBITA: 1610 W
152126
3.283.122.81
104711271208
3.953.743.48
125613361417
4.634.424.11
141714811562
5.305.044.78
153015941674
5.985.725.46
162616741755
6.606.346.08
167417231803
7.286.996.76
170717871852
MSH-GA50VB - : MUH-GA50VB - (230V)E1E1
Funzionamento in RISCALDAMENTO (230 V)
NOTA Q: Potenzialità di Riscaldamento (kW) INPUT: Potenza Assorbita (W)
ESTERNO BU (°C)INTERNOBS (°C)
-10 -5 0 5 10 15 20Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
POTENZIALITA’: 7,2 kW POTENZA ASSORBITA: 2480 W
152126
4.544.323.89
161217361860
5.475.184.82
193420582182
6.416.125.69
218222822406
7.346.986.62
235624552579
8.287.927.56
250525792703
9.148.788.42
257926542778
10.089.689.36
262927532852
MSH-GA60VB - : MUH-GA60VB - (230V)E1E1
ESTERNO BU (°C)INTERNOBS (°C)
-10 -5 0 5 10 15 20Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
POTENZIALITA’: 9,4 kW POTENZA ASSORBITA: 3430 W
152126
5.925.645.08
223024012573
7.146.776.30
267528473018
8.377.997.43
301831563327
9.599.128.65
325933963567
10.8110.349.87
346435673739
11.9411.4711.00
356736703842
13.1612.6412.22
363638073945
MSH-GA80VB - : MUH-GA80VB - (230V)E1E1
NOTA Q: Potenzialità di Riscaldamento (kW) INPUT: Potenza Assorbita (W)
NOTA Q: Potenzialità di Riscaldamento (kW) INPUT: Potenza Assorbita (W)
32
9
Quando l’unità interna è controllata dal telecomando la modalità di funzionamento, la temperatura impostata e la velocità delventilatore sono memorizzate dalla scheda dell’unità interna. La FUNZIONE DI RIAVVIAMENTO AUTOMATICO intervieneal momento del ripristino dell’alimentazione dopo un’interruzione. Essa consente all’unità di riavviarsi automaticamente usandole impostazioni memorizzate. Tuttavia, se prima dell’interruzione l’unità stava funzionando in modalità “I FEEL CONTROL” lamemorizzazione non avviene in quanto il funzionamento è determinato dalle condizioni iniziali della temperatura ambiente.
9-3. FUNZIONE DI RIAVVIAMENTO AUTOMATICO
Tabella 1
Unità No. 1
Unità No. 2
Unità No. 3
Unità No. 4
Come un’ unità
Nessuna modifica
–
–
–
Come due unità
Come a sinistra
Saldare J1
–
–
Come tre unità
Come a sinistra
Come a sinistra
Saldare J2
–
Come quattro unità
Come a sinistra
Come a sinistra
Come a sinistra
Saldare J1 e J2
9-2. MODIFICA DELLA SCHEDA PER FUNZIONAMENTO INDIVIDUALENello stesso locale possono venire installate fino a 4 unità interne pilotate da telecomando. In questi casi se si desidera gestireindividualmente ciascuna di esse è necessario modificare le schede dei telecomandi in funzione della quantità delle unitàindividualmente controllate.Modalità di modifica delle schede del telecomandoAsportare le batterie prima di eseguire la modifica. La scheda è strutturata come segue:
9-1. ABBREVIAMENTO DELLE TEMPORIZZAZIONICortocircuitando i connettori JPG e JPS della scheda di controllo dell’unità interna è possibile abbreviare come segue letemporizzazioni:Temporizzazione di 1 minuto ➔ Temporizzazione di 1 secondoTemporizzazione di 3 minuti ➔ Temporizzazione di 3 secondi (affinché possa avviarsi il compressore devono trascorrere tre
minuti che possono comunque venire abbreviati cortocircuitandoJPG e JPS).
La scheda riporta le stampigliature “J1” e “J2”. Saldare “J1” e “J2” in funzione della quantità di unità interne indipendenti comeindicato nella tabella 1. Terminate le modifiche premere il pulsante RESET.
NOTA: Estrarre le batterie e premere dueo tre volte il pulsante diMARCIA/ARRESTO(ON/OFF).Terminate le modifichereinserire la batterie e premere ilpulsante RESET.
MSH-GA50VB -MSH-GA60VB -MSH-GA80VB - E1
E1
E1
Impostazione del telecomando per un’unità interna particolareDopo avere dato tensione all’apparecchio per la prima volta, il primo telecomando che manda un segnale viene consideratocome “telecomando dell’ unità interna”.Da questo momento in poi essa terrà in considerazione solo i suoi segnali.Tale impostazione viene comunque persa se viene tolta tensione all’apparecchio.Al ripristino della tensione è necessario rieseguire l’impostazione.
Telecomando Modello KM04A
J2J1
FUNZIONI DI SERVIZIO
Modalità di disattivazione della funzione di riavviamento automatico1Togliere tensione all’unità.2Estrarre la scheda di controllo dell’unità interna, la scheda
del ricevitore dei segnali e la scheda di indicazione(cfr. pag. 19).
3Saldare il cavallotto al RESISTORE JR07 della scheda dicontrollo dell’unità interna (cfr. pag. 43).
JR07
IC152
CN
151
CN
112
CN
111
CN
121
SW
1
IC101
RA
102
C11
CN201
CN211
TAB12
Funzionamento1 Se è stata interrotta l’alimentazione le impostazioni di funzionamento rimangono memorizzate.2 Al ripristino dell’alimentazione l’unità si riavvia automaticamente utilizzando le impostazioni memorizzate (devono tuttavia
passare tre minuti prima che il compressore possa riprendere a funzionare).NOTE
.• Le impostazioni vengono memorizzate dopo 10 secondi dall’azionamento del telecomando.• Le impostazioni delle funzioni di ATTIVAZIONE e di DISATTIVAZIONE TEMPORIZZATE vengono perse in caso di interruzione
dell’alimentazione.• Se prima di un’interruzione l’unità è stata disattivata tramite il telecomando al ripristino dell’alimentazione il riavviamento
automatico non avviene.• Per prevenire l’intervento del magnetotermico generale al momento del ripristino dell’alimentazione si consiglia di differenziare
i tempi di avviamento delle varie utenze della rete di alimentazione locale.• Quando alla stessa rete sono collegati più climatizzatori, al termine di un’interruzione dell’alimentazione tutti i compressori
potrebbero avviarsi contemporaneamente.Per evitare brusche cadute di tensione e le loro conseguenze, in questi casi è quindi indispensabile inserire dei dispositiviche provochino l’avviamento di un compressore dopo l’altro.
33
34
9-4. FORZATURA DELLO SBRINAMENTO PER MOTIVI DI SERVIZIOL’ esecuzione dello sbrinamento può essere ottenuta indipendentemente dalle restrizioni imposte dall’intervallo di sbrinamentocortocircuitando i connettori JPDS e JPSG (MUH-GA50VB) o JPG1 ed R871 (MUH-GA60/GA80VB) della scheda di sbrinamento(cfr. pag. 52 o pag. 53).
9-5. MODIFICA DELLE IMPOSTAZIONI DI SBRINAMENTOInterrompendo il cavallotto JRF della scheda di sbrinamento si modifica l’intervallo di sbrinamento.Interrompendo invece il cavallotto JRG della scheda di sbrinamento si modifica la temperatura di sbrinamento.
E1
Cavallotto
JRF
JRG
Unità esterna modello Modifica
L’ intervallo di sbrinamento passa da 40 a 15 minuti.
La temperatura di sbrinamento passa da -3 a 0 °C (MUH-GA50VB)La temperatura di sbrinamento rimane a -3 °C (MUH-GA60/GA80VB)La temperatura di fine sbrinamento passa da 3 a 10 °C (MUH-GA50VB)La temperatura di fine sbrinamento passa da 3 a 15 °C (MUH-GA60VB)La temperatura di fine sbrinamento passa da 13 a 15 °C (MUH-GA80VB)
E1
E1
MUH-GA50VB -
MUH-GA60VB -
MUH-GA80VB -
MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1E1E1
35
1. Prima di eseguire la diagnosi controllare quanto segue:(1) Tensione di alimentazione(2) Esattezza dei collegamenti elettrici tra unità interna ed unità esterna.2. Durante l’esecuzione delle operazioni di servizio fare attenzione a quanto segue:(1) Prima di iniziare ogni operazione di servizio arrestare l’unità usando il telecomando e, dopo essersi accertati che i deflettori
orizzontali siano chiusi, aprire il magnetotermico o estrarre la spina dalla presa.(2) Accertarsi che l’unità non sia sotto tensione prima di smontare il pannello frontale, la carrozzeria, il pannello superiore e
la scheda elettronica di controllo.(3) La scheda di controllo elettronica deve essere smontata afferrandola per gli spigoli e SENZA sollecitarla eccessivamente.(4) I connettori devono essere estratti dagli alloggiamenti afferrandoli direttamente e NON tirandoli per i cavi.
1 Smontare il coperchio frontale e sostituire le batterie.Rimontare poi il coperchio frontale.
Cavi Alloggiamento
MSH-GA50VB -MSH-GA60VB -MSH-GA80VB - E1
E1
E1
Pulsante RESET
Il polo negativo delle batteriedeve essere inserito per primo.Controllare che le batteriesiano state inserite rispettandola polarità indicata.
2 Premere il pulsante RESET con la punta di unapenna a sfera.
NOTA: Se il pulsante RESET non venisse premuto il telecomando potrebbe funzionare male.
10-1. Precauzioni per l’esecuzione della diagnosi
3. Esecuzione della diagnosi(1) Controllare innanzitutto che la SPIA DI FUNZIONAMENTO dell’unità interna stia effettivamente lampeggiando per indicare
un’anomalia. Prima di iniziare i lavori controllare anche quante volte la spia lampeggia.(2) Controllare poi che i connettori ed i capicorda siano ben inseriti nelle rispettive sedi(3) Se si suppone che la scheda elettronica di controllo sia difettosa controllare l’integrità delle sue piste in rame e se in essa
sono presenti scoloriture e/o bruciature.(4) Per l’esecuzione della diagnosi fare riferimento ai paragrafi 10.2. e 10.3.4. Sostituzione delle batterie del telecomando:
Una volta scariche le batterie impediscono il regolare funzionamento del telecomando.Sostituendole con batterie cariche il telecomando torna a funzionare regolarmente.
10 DIAGNOSI DELLE ANOMALIE
36
Inizio
L’unità internafunziona.L’unità esterna nonfunziona
L’unità esterna nonriceve i segnali deltelecomando
L’unità internafunziona.L’unità esterna nonfunzionanormalmente
La SPIA DIFUNZIONAMENTOdell’unità interna lampeggia
L’unità esternafunziona solo incondizioni diProva diFunzionamento
L’unità esternanon funzionaneppure incondizioni diProva diFunzionamento
L’unità internafunziona premendol’interruttore per ilFUNZIONAMENTODI EMERGENZA
L’unità interna nonfunziona neppurepremendol’interruttore per ilFUNZIONAMENTODI EMERGENZA
Controllare iltermistore dellatemperaturaambiente,facendoriferimento alloschema “Punti diProva” di cui alparagrafo 10-6.
Fare riferimentoal punto“Controllodell’unitàesterna”
Fare riferimento alpunto B “Controllodel telecomando edella scheda diricevimento” di cuial paragrafo 10-5.
Lampeggicontinui adintervalli di 0,5sec. Causa:problemi dicollegamentoelettrico traunità interna edunità esterna
2 lampeggi.Causa:problemi altermistore dellabatteria interna/ dellatemperaturaambiente
3 lampeggi.Causa:problemi almotore delventilatoredell’unitàinterna
6 lampeggi.Causa:problemi altermistoredell’unitàesterna
7 lampeggi.Causa:problemi alsistema dicontrollodell’unitàesterna
Fare riferimentoal punto D“Modalità dicontrollo deglierrori dicollegamento”(con unitàesterna nonfunzionante) dicui al paragrafo10-5.
Controllare iltermistore dellatemperaturaambiente edella batteriainterna,facendoriferimento alloschema “Puntidi Prova” di cuial paragrafo10-6.
Fare riferimentoal punto A“Controllo delmotore delventilatoreinterno” di cuial paragrafo10-5.
Fare riferimentoal punto“Controllo deltermistoredell’unitàesterna”
Sostituire lascheda disbrinamento
10 lampeggi.Causa:problema dibassatemperatura dimandata dellaunità esterna(MUH-GA80VB)
Fare riferimentoal punto“Controllo dellaLEV”
4 lampeggi.Causa:problemi alsistema dicontrollodell’unitàinterna
Sostituire alscheda dicontrollodell’unitàinterna.
Come per l’ unità interna..
1. Controllare icollegamenti elettricitra unità interna edunità esterna
2. Fare riferimento alpunto B “Controllodella scheda dicontrollo elettronicadell’unità interna” dicui al paragrafo 10-5.
L’unità esternanon si arrestaneppure se siarresta l’unitàinterna
L’unità nonfunzionanormalmente inRAFFREDDA-MENTO o inRISCALDA-MENTO
Fare riferimentoal punto“Controllodell’unitàesterna”
Fare riferimentoal punto“Controllo dellabobina dellavalvola diinversione”
10-2. Istruzioni per la diagnosi delle anomalie
37
10-3. Tabella di diagnosi delle anomalie• L’indicazione che segue non dipende dalla forma delle spie
Spia di funzionamento Lampeggiante
Spenta
Prima di prendere provvedimenti accertarsi sempre che il sintomo riappaia.Tabella di autodiagnosi
NOTA : Se viene rilevata una delle anomalie di cui sopra dopo l’inizio del funzionamento dell’unità interna (cioè per la prima voltadopo che è stata data tensione) la scheda di controllo dell’unità interna disattiva il ventilatore dell’unità interna stessa efa lampeggiare la SPIA DI FUNZIONAMENTO.
No.
1
2
4
6
7
SintomoIndicazione Metodo di riscontro Controlli da eseguire
0,5 secondi illuminata
0,5 secondi non illuminata
Errore dicollegamento
Termistoredell’unitàesterna
Anomaliadel sistemadi controllodell’unitàesterna
Termistorebatteriainterna
Arresto dopo tre minuti dal momento in cuiviene data tensione in caso di mancatoricevimento del segnale seriale
<Cortocircuito dei termistori>L’anomalia viene riscontrata quando i termistori risultanoin cortocircuito dopo l’avviamento del compressore.<Apertura dei termistori>L’anomalia viene riscontrata quando i termistori risultanoaperti dopo dell’avviamento del compressore.Il termistore della temperatura di mandata viene comunqueritenuto in stato di anomalia quando è trovato in cortocircuitodopo 10 minuti dell’avviamento del compressore.
MUH-GA60VBImpossibilità di eseguire la lettura dei daticontenuti nella memoria non volatile dellascheda di sbrinamento dell’unità esterna (ilriavviamento avviene dopo 3 minuti)
• Controllare la scheda disbrinamento facendo riferimentoal punto “Controllo dei termistoridell’unità esterna.
• Scarsità di refrigerante.
• Controllare la scheda disbrinamento dell’unità esterna.
• Vedere il punto D “Modalità dicontrollo degli errori di collega-mento” di cui al paragrafo 10-5.
3Motore delventilatoreinterno
MUH-GA80VBInterventodellaprotezionedi bassatemperaturadi mandata
MUH-GA80VBPer 20 minuti consecutivi la temperatura dimandata è stata < 50 °C in raffreddamento oa 49 °C in riscaldamento. rato continuamenteper 5 minuti
Anomalia
L’unitàesterna nonfunziona
Termistoretemperaturaambiente
2 lampeggi
2,5 secondi spenta
Ricerca dei cortocircuiti dei termistori dellabatteria esterna/della temperatura ambienteogni 8 secondi di funzionamento
• Controllo della resistenza deltermistore principale della batteriainterna, del termistore secondariodella batteria interna e deltermistore della temperaturaambiente (cfr. pag. 43)
3 lampeggi
2,5 secondi spenta
Il motore delventilatore internoripete dei cicli con12 sec. di marciae 3 min. di arresto
Mancata emissione per 12 secondi del segnaledi feed back della frequenza di rotazione delmotore mentre il motore stesso è in funzione.
• Vedere il punto A “Controllodel ventilatore interno” di cui alparagrafo 10-5.
4 lampeggi
2,5 secondi spenta
Sistema dicontrollodell’unitàinterna
L’unità esterna si arresta se non è possibileleggere i dati contenuti nella memoria volatiledella scheda di controllo dell’unità interna
L’unitàesterna nonfunziona
L’unitàesterna nonfunziona
• Controllare la scheda di controllodell’unità interna
6 lampeggi
2,5 secondi spenta
MUH-GA80VB• Vedere quanto precisato in
merito al “Controllo della LEV”• Controllare l’integrità del circuito
frigorifero e l’esattezzadell’ammontare della carica direfrigerante
L’unitàesterna nonfunziona
L’unitàesterna nonfunziona
L’unitàesterna nonfunziona
5
7 lampeggi
2,5 secondi spenta
10 lampeggi
2,5 secondi spenta
· Il lampeggio della SPIA DI FUNZIONAMENTO (a sinistra) indica possibili anomalie.· La SPIA DI FUNZIONAMENTO (a sinistra) è illuminata quando l’unità sta funzionando
normalmente.
38
MSH-GA50VB -MSH-GA60VB -MSH-GA80VB - E1
E1
E1
Componente FiguraMetodo e criterio di controllo
Motore del ventilatoreinterno MF.
MSH-GA50/GA60VBFUSIBILE INTERN0INTERVIENE A 145 °C
MSH-GA80VBPROTEZIONE INTERNAINTERVIENE A 13 ±5°C.
Colore cavo
BIA-NERNER-ROS
Anomalia
Apertura ocortocircuito
MSH-GA50/GA60VB282 " ~ 305 "141 " ~ 152 "
Misurare la resistenza tramite un tester(temperatura del componente tra 10 e 30 °C).
.
Normalità8 k" ~ 20 k"
AnomaliaApertura o cortocircuito
Termistore dellatemperatura ambiente RT11Termistore della batteriainterna RT12 (principale)ed RT13 (secondario)
Servomotore dei deflettoriorizzontali MV1
Servomotore dei deflettoriverticali MV2
Lato
mot
ore
Lato
sen
sore
Misurare la resistenza tra i morsetti tramite un tester(temperatura del componente tra 10 e 30 °C).
Colore cavoMAR-GIA
GIA-GRI
Anomalia
0 o 5 V costanti
Normalità4.5 ~ 5.5V
Misurare la tensione di alimentazione.
Ad ogni rotazione del motore:0 V ➔ 5 V ➔ 0 V
(circa)
Normalità282" ~ 306 "
AnomaliaApertura o cortocircuito
Misurare la resistenza tra i morsetti tramite un tester(temperatura del componente tra 10 e 30 °C).
NE
R
RO
S
BIAGR
IG
IAM
AR
PRINC
AUX
FUS.
NE
R
RO
S
BIAGR
IG
IAM
AR
MSH-GA80VB132 " ~ 144 "152 " ~ 166 "
Normalità
MSH-GA50/GA60VB
MSH-GA80VB
GIA
VERARA
MAR
ROS ROTORE
PRINC
AUX.
P
:PROTEZIONE INTERNAP
10-4. Criteri di controllo dei componenti principali
39
Sì
Sì
Controllo del ventilatore internoA
Controllo del telecomando e della scheda del ricevitoreB
Quando la SPIA DI FUNZIONAMENTO lampeggia 3 volteIl ventilatore interno non funziona
Sostituire il motore del ventilatore interno
Scollegare i cavi dal connettore CN211 sulla scheda elettronica di controllo dell’unità internaControllare la resistenza tra i capicorda: No. 1 e No. 4 e poi No. 3 e No. 4
I cavi sono collegati?
Ricollegare i cavi
Le saldature sono integre? Ripassare le saldature
La resistenza corrisponde a 0 (cortocircuito) o adinfinito (apertura)?
L’unità interna funziona premendo l’interruttore di FUNZIONAMENTO DI EMERGENZA ma non funziona con il telecomando
Sostituire le batterie (cfr. pag. 36)
Accendere una radio in gamma d’onda AMed azionare il telecomando
La radio acquisisce dei disturbi?
Entro 1 m ci sono lampade afluorescenza con inverter o conreattore rapido?
Misurare la tensione tra No. 2 + e No. 1 - del connettore CN301 della scheda del ricettore mentre vienepremuto un pulsante del telecomando
La tensione è di circa 4 V in c.c.?Sostituire la scheda di controllo dell’unitàinterna
Sostituire la scheda del ricevitore dei segnali
Sostituire il telecomando
● Allontanare le lampade dall’unitàCollegare un filtro antidisturbi alla lampada●
Sì (0 o infinito)No
(altro)
Sì
NoSìNo
Premere il pulsante ON/OFF del telecomando
Le indicazioni sul display deltelecomando sono visibili?
Togliere le batterie, reinserirle e poi premereil pulsante RESET del telecomando econtrollare infine che l’unità risponda agliordini impartiti dal telecomando.
Sì
L’unità risponde agli ordini deltelecomando?
Sì
OK
No
(non chiaro)
Sì
No
No
No (0 o 5 V in c.c.)
No
Togliere tensione e controllarevisivamente il connettore CN211.
w Controllare se il telecomando è in uso esclusivo dell’unità interna interessata.
Dare tensione ed arrestare l’apparecchio in caso stiafunzionando. Inserire quindi un cacciavite nella boccadi mandata per fare eseguire lentamente una o piùrotazioni al ventilatore e misurare la tensione tra No.2 + e No. 3 - di CN121
Sostituire la scheda elettronica di controllo dell’unità interna
La tensione varia ciclicamente da 0 a 5 V in c.c.?
Sì
No
10-5. Schemi a blocchi di diagnosi delle anomalie
40
Controllo della scheda elettronica di controllo dell’unità internaC
Controllare visivamente l’integrità di ogniparte della scheda elettronica di controllodell’unità interna
Sostituire il fusibile
E’ saltato il fusibile F11?
Sostituire il motoredel ventilatore
Sostituire la schedadi controllo dell’unitàinterna
La resistenza degliavvolgimenti delmotore del ventilatoreè pari a 0 Ohm?
La resistenza degliavvolgimenti delservomotore del deflettoreè pari a 0 Ohm?
No
Sì
Sostituire il servomotoredel deflettore
Sì
Sì
Il varistore NR11 èbruciato?
Sostituire il varistore
Sì
Togliere tensione e scollegare della scheda elettronicadi controllo il connettore CN211 del motore del ventilatoreinterno ed il connettore CN151 del servomotore deldeflettore dando infine tensione.
No
L’unità risponde agli ordini del telecomando? LaSPIA DI FUNZIONAMENTO si illumina premendol’interruttore di FUNZIONAMENTO DIEMERGENZA?
Sì
No
Toglieretensione
Toglieretensione
Varistore NR11
Scheda di controllodell’unità interna
Fusibile F11
No
No
L’unità non funziona tramite il telecomando e, premendo l’interruttore di FUNZIONAMENTO DI EMERGENZA, la SPIA DIFUNZIONAMENTO non si illumina
41
Modalità di controllo degli errori di collegamentoD
1. Interrompere l’alimentazione e scollegare l’unità esterna dall’unità interna agendo incorrispondenza dell’unità interna
2. Cortocircuitare i morsetti N e 33. Ripristinare l’alimentazione e premere l’interruttore di FUNZIONAMENTO DI EMERGENZA
Durante il FUNZIONAMENTO DIEMERGENZA tra i capi di R601 cisono 10 V in c.a.?
Come per l’ unità esterna
Inizio
No
NoTra i capi di R132 della scheda di controllodell’unità interna ci sono 20 V in c.c.?
• Dare tensione all’unità interna ed all’unità esterna• Premere l’interruttore di FUNZIONAMENTO DI EMERGENZA
Ci sono errori di collegamento, contattilaschi o cavi scollegati?
Correggere oripristinare icollegamenti
Sostituire la scheda elettronicadi controllo interna
Tra i morsetti N e 3 della morsettiera dell’unitàesterna ci sono 230 V in c.a.?
No Controllare l’integrità sistema alimentazioneed i collegamenti elettrici dell’unità esterna
Sì
No Sostituire la scheda disbrinamento
Sì
NoRipristinare i collegamenti traCN730 della scheda disbrinamento e la morsettieradell’unità esterna
Sostituire la scheda di sbrinamento
Sì
Tra i morsetti J205 + e J101 - (mod.MUH-GA50VB) / J101 + e J401 - modd.MUH-GA60/GA80VB della scheda disbrinamento ci sono 5 V in c.c.?
Sì
Sì
Dopo 3 minuti la SPIA DI FUNZIONAMENTO dell’unitàinterna lampeggia alla frequenza di 1 secondo (0,5secondi di illuminazione e 0,5 secondi di spegnimento)indicando un errore di collegamento? w
wLa cortocircuitazione di JPG e di JPS della scheda elettronica dicontrollo dell’unità interna consente la visualizzazionedell’autodiagnosi in 3 secondi
• Interrompere l’alimentazione dell’unità interna• Ripristinare i collegamenti tra unità interna
ed unità esterna
Ripristinare l’alimentazione dell’unità esterna
Quando la SPIA DI FUNZIONAMENTO lampeggia ad intervalli di 0.5 secondiL’unità esterna non funziona
42
10-6. Punti di controlloMSH-GA50VB - MSH-GA60VB - MSH-GA80VB -Scheda elettronica di controllo dell’unità interna
E1E1E1
Alimentazione del motoredel ventilatore
Fusibile F11250 V C.A. - 3.15 A
} Alimentazione a230 V in c.a.
+} 5 V in c.c.
Punto di abbreviamentotemporizzazioni(JPS, JPG)(cfr. pag. 33)
Interruttore delfunzionamento diemergenza
+}
12 V in C.C.
Termistore batteria interna (RT12 princ.) (RT13 sec.)Termistore della temperatura ambiente (RT11)
Res
iste
nza
(kO
hm
)
Termistore temperaturaambiente RT11Termistore principalebatteria interna RT12
Abbandono della funzione di“Riavviamento Automatico”:Saldare il cavallotto a JR07(Cfr. pag. 34)
Mod. MSH-GA80VBTermistoresecondario dellabatteria interna RT13
R132
Scheda del ricettore dei segnali
Temperatura °C
10-7. Precauzioni per l’esecuzione della diagnosi1. Prima di eseguire la diagnosi controllare quanto segue:(1) Tensione di alimentazione(2) Esattezza dei collegamenti elettrici tra unità interna ed unità esterna.2. Durante l’esecuzione delle operazioni di servizio fare attenzione a quanto segue:(1) Prima di iniziare ogni operazione di servizio arrestare l’unità usando il telecomando e, dopo essersi accertati che il deflettore
orizzontale sia chiuso, aprire il magnetotermico o estrarre la spina dalla presa.(2) Accertarsi che l’unità non sia sotto tensione prima di smontare il pannello frontale, la carrozzeria, il pannello superiore
e la scheda elettronica di controllo.(3) La scheda di controllo elettronica deve essere smontata afferrandola per gli spigoli e SENZA sollecitarla eccessivamente.(4) I connettori devono essere estratti dagli alloggiamenti afferrandoli direttamente e NON tirandoli per i cavi.
MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1E1E1
Cavi Alloggiamento
3. Esecuzione della diagnosi(1) Controllare innanzitutto che la SPIA DI FUNZIONAMENTO dell’unità interna stia effettivamente lampeggiando per indicare
un’anomalia. Prima di iniziare i lavori controllare anche quante volte la spia lampeggia.(2) Controllare poi che connettori e capicorda siano ben inseriti nelle rispettive sedi(3) Se si suppone che la scheda elettronica di controllo sia difettosa controllare l’integrità delle sue piste in rame e se in essa
sono presenti scoloriture e/o bruciature.(4) Per l’esecuzione della diagnosi fare riferimento allo schema a blocchi di cui al paragrafo 10-8
43
44
Inizio
L’unità internafunziona. L’unitàesterna nonfunziona
L’unità esternanon riceve isegnali deltelecomando
L’unità internafunziona. L’unitàesterna nonfunzionanormalmente
La SPIA DIFUNZIONAMENTOdell’unità internalampeggia
L’unità esternafunziona solo incondizioni diProva diFunzionamento
L’unità esternanon funzionaneppure incondizioni diProva diFunzionamento
L’unità internafunziona premendol’interruttore per ilFUNZIONAMENTODI EMERGENZA
L’unità interna nonfunziona neppurepremendol’interruttore per ilFUNZIONAMENTODI EMERGENZA
Controllare ilTermistore dellatemperaturaesterna,facendoriferimento alloschema “Punti diProva”.
Fare riferimentoal punto A“Controllodell’unitàesterna” di cui alparagrafo 10.10.
Fare riferimento alpunto “Controllodel telecomando edella scheda diricevimento”.
Lampeggicontinui adintervalli di 0,5sec. Causa:problemi dicollegamentoelettrico traunità interna edunità esterna.
Fare riferimentoal punto D“Modalità dicontrollo deglierrori dicollegamento”(con unitàesterna nonfunzionante) dicui al paragrafo10.10.
2 lampeggi.Causa: problemial termistoredella batteriainterna / dellatemperaturaambiente
3 lampeggi.Causa:problemi almotore delventilatoredell’unitàinterna.
Controllare iltermistore dellatemperaturaambiente edella batteriainterna,facendoriferimento alloschema “Puntidi Prova”.
Fare riferimentoal punto“Controllo delmotore delventilatoreinterno”
4 lampeggi.Causa:problemi alsistema dicontrollodell’unitàinterna
Sostituire lascheda dicontrollodell’unitàinterna
1. Controllare icollegamenti elettricitra unità interna edunità esterna
2. Fare riferimento alpunto “Controllo dellascheda di controlloelettronica dell’unitàinterna”.
L’unità esternanon si arrestaneppure se siarresta l’unitàinterna
L’unità nonfunzionanormalmente inRAFFREDDA-MENTO o inRISCALDA-MENTO.
Fare riferimentoal punto B“Controllodell’unitàesterna” di cui alparagrafo 10.10.
Fare riferimentoal punto C“Controllo dellabobina dellavalvola diinversione” di cuial paragrafo10.10.
Come per l’ unità interna.
6 lampeggi.Causa:problemi altermistoredell’unitàesterna
7 lampeggi.Causa: problemial sistema dicontrollodell’unitàesterna
Fare riferimentoal punto F“Controllo deltermistoredell’unitàesterna” di cuial paragrafo10.10.
Sostituire lascheda disbrinamento
10 lampeggi.Causa: Unitàesterna MUH-GA80VB –problemi diprotezione dibassatemperatura dimandata
Fare riferimentoal punto E“Controllo dellaLEV” di cui alparagrafo 10.10.(Mod.MUH-GA80VB)
10-8. Istruzioni per la diagnosi delle anomalie
45
10-9. Criteri di controllo dei componenti principali
MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1E1E1
Componente FiguraMetodo e criterio di controllo
Misurare la resistenza tra i morsetti tramite un tester(temperatura del componente tra -10 e 40 °C).
Compressore (MC)PROTEZIONEINTERNAAPRE A 160 ± 5 °CCHIUDE A 90 ± 10 °C Normalità
MUH-GA50VBMorsetto
C – RC – S
1.59 " ~ 1.95 "2.65 " ~ 3.24 "
MUH-GA60VB0.71 " ~ 0.87 "1.45 " ~ 1.77 "
MUH-GA80VB0.56 " ~ 0.71 "1.43 " ~ 1.76 "
Anomalia
Apertura ocortocircuito
Bobina della Valvoladi Inversione (21S4)
Valvola di EspansioneLineare (LEV)MUH-GA80VB
Misurare la resistenza tramite un tester(temperatura del componente tra -10 e 40 °C).
Normalità2.673 k" ~ 3.268 k"
AnomaliaApertura o cortocircuito
Colore cavoBIA-ROSROS-ARAGIA-MARMAR-BLU
AnomaliaNormalità
41.0 " ~ 49.0 "
Misurare la resistenza tra i morsetti tramite un tester(temperatura del componente tra -10 e 40 °C).
Misurare la resistenza tramite un tester(temperatura del componente tra -10 e 40 °C).
.
Termistore dellatemperatura dimandata RT62MUH-GA80VB
Termistore dellatemperatura esternaRT63MUH-GA80VB
Misurare la resistenza tramite un tester dopo avere scaldato il termistoretenendolo in mano(temperatura del componente tra 0 e 40 °C).
.
Normalità120 k" ~ 800k"
AnomaliaApertura o cortocircuito
Normalità5 k" ~ 60 k"
AnomaliaApertura o cortocircuito
Misurare la resistenza tramite un tester(temperatura del componente tra -10 e 40 °C).
.
Normalità5 k" ~ 60 k"
AnomaliaApertura o cortocircuito
Termistore disbrinamento (RT61)
w Valori di riferimento
MUH-GA50VB MUH-GA60VB MUH-GA80VB
Misurare la resistenza tra i morsetti tramite un tester(temperatura del componente tra -10 e 40 °C).
Colorecavo
BIA-NERNER-ROSNER-GIAGIA-ROS
Apertura ocortocircuito
70.4 " ~ 85.5 " 73.6 " ~ 89.3 "
––
61.0 " ~ 74.0 "82.5 " ~ 100.2 "
––
55.4 " ~ 67.7 "–
49.3 " ~ 60.3 "22.9 " ~ 28.0 "
Normalità Anomalia
Motore del ventilatoreinterno MF
PROTEZIONEINTERNAMUH-GA50VBMUH-GA60VBAPRE A 130 ± 5 °CCHIUDE AD 83 ± 15 °C
PROTEZIONEINTERNAMUH-GA80VBAPRE A 135 ± 5 °CCHIUDE AD 83 ± 15 °C ROS ARA BIAGIANER
PRINC
AUX.1AUX.2
C
P
P ~
NERR
PRINCAUX.
ROS
S
CBIA
PRINC
AUX.
NER
MUH-GA50VBMUH-GA60VB
MUH-GA80VB
ROS BIAARA
P
LEV
BIA 6
ROS1
ARA4
GIA
5
MA
R2
BLU
3
: PROTEZIONE INTERNAP
Apertura ocortocircuito
46
A Controllo dell’unità esterna
Il compressore e/o il ventilatore dell’unità esterna non funzionano
Sì
lI compressore nonfunziona
Sì SìTra 3 del contattore del compressore52C e L della morsettiera TB1 dell’unitàesterna ci sono 230 V in c.a.?
Attivare l’unità in RAFFREDDAMENTO o RISCALDAMENTO agendo sull’interruttore diFUNZIONAMENTO DI EMERGENZA. Si attiva una temporizzazione di 3 minuti. Ha inizio la provadi funzionamento la cui durata corrisponde a 30 minuti
Il motore del ventilatoredell’unità esterna nonfunziona
No
Correggere i collegamentielettrici tra l’unità interna el’unità esterna
Correggere i collegamentielettrici
Controllare il compressore ed il suo condensatore facendoriferimento a pag. 46
Sì
Tra 4 del contattore del compressore52C e TAB20 della scheda disbrinamento ci sono 230 V in c.a.?w
Tra L ed N della morsettiera TB1dell’unità esterna ci sono 230 V inc.a.?
Sostituire lascheda disbrinamento
Sostituire lascheda disbrinamento
No
No
Sì Sì
No
Controllare il motore delventilatore esterno facendoriferimento a pag. 27
Tra 4 del contattore del compressore52C e TAB20 della scheda disbrinamento ci sono 230 V in c.a.?w
Sostituire la scheda disbrinamento
No
Sì
Correggere i collegamentielettrici tra l’unità interna el’unità esterna
Correggere i collegamentielettrici
Tra L ed N della morsettiera TB1dell’unità esterna ci sono 230 V inc.a.?
No
No
Tra J101 - e J205 + della scheda disbrinamento ci sono 5 V in c.c.?w
Tra J101 - e J205 + della scheda disbrinamento ci sono 5 V in c.c.?w
w Fare riferimento a pag. 52.
MUH-GA50VB
10-10. Schemi a blocchi di diagnosi delle anomalie
47
Tra L ed N della morsettieradell’unità esterna ci sono 230 V in c.a.?
No Controllare il circuito dialimentazione ed i cavi dicollegamento dell’unità esterna
Sì
lI compressore nonfunziona
Sì
3 minuti dopo avere datotensione tra A1 ed A2 delcontattore del compressore(52C) ci sono 230 V in c.a.?
Attivare l’unità in RAFFREDDAMEN-TO o RISCALDAMENTO agendosull’interruttore di FUNZIONAMENTODI EMERGENZA
No Correggere icollegamenti elettrici
Correggere icollegamenti elettrici
Controllare il compressorefacendo riferimento a pag.46
Sostituire il contattore delcompressore (52C)
Chiudere circuito alimentazione
Sì
Tra 2/T1 del contattore delcompressore (52C) e L dellamorsettiera dell’unità esternaci sono 230 V in c.a.?
Sì
Sostituire la scheda disbrinamento
Sostituire la scheda disbrinamento
No
Sì
No Tra 1/L1 del contattore delcompressore (52C) e N dellamorsettiera dell’unità esternaci sono 230 V in c.a.?
No
No
Sì
Tra J101 + e J401 - dellascheda di sbrinamento ci sono5 V in c.c.?w
Tra 1 ed 3 di CN730 dellascheda di sbrinamento cisono 230 V in c.a.?w
MUH-GA60VBMUH-GA80VB
Correggere icollegamenti elettrici
Sì Sì
Attivare l’unità inRAFFREDDAMENTO oRISCALDAMENTO agendosull’interruttore diFUNZIONAMENTO DIEMERGENZA
Tra (1) ed (3) di CN730della scheda disbrinamento ci sono230 V in c.a.?*
No
Controllare il motore delventilatore esterno facendoriferimento a pag. 46
Sì
Tra (1) ed (3) di CN730 dellascheda di sbrinamento cisono 230 V in c.a.?*
Sostituire la scheda disbrinamento
Sostituire la scheda disbrinamento
No
NoIl motore del ventilatoredell’unità esterna nonfunziona
w Fare riferimento a pag. 53
Il compressore si arresta?No
Sì
Tra 3 del contattore del compressore 52Ced N della morsettiera TB1 dell’unitàesterna ci sono da 230 V in c.a.?
Sostituire la scheda disbrinamento
Sì
OK
No
Il ventilatore esterno si arresta? Sostituire la scheda disbrinamento
Sì
OK
No
Correggere i collegamenti elettrici
Interrompere il circuito dialimentazione e richiuderlodopo un minuto
48
MUH-GA50VB
MUH-GA60VBMUH-GA80VB
B Controllo dell’unità esterna
Il compressore e/o il ventilatore dell’unità esterna non si arrestano
L’unità funziona in RISCALDAMENTO anche se è impostata in RAFFREDDAMENTO
w Misurare innanzitutto la resistenza della bobina della valvola di inversione per controllare se è interrotta o in cortocircuito
Controllo della bobina della valvola di inversioneC
Il compressore si arrestadopo 30 secondi?
No
Sì
Tra A1 ed A2 del contattoredel compressore 52C ci sono230 V in c.a.?
Sostituire la scheda disbrinamento
Sì
Ok
No
Il ventilatore esterno siarresta dopo 30 secondi?
Sostituire la scheda disbrinamento
Sì
Ok
No
Tra 2/T1 ed A2 del contattored52C del compressore ed Ndella morsettiera esterna cisono 230 V in c.a.?
Sì
Sostituire il contattore52C del compressore
No Correggere icollegamenti elettrici
Dopo 3 minuti l’ apparecchiofunziona inRISCALDAMENTO?
OkNo
Sostituire la scheda disbrinamento
Sì
Sì
NoSostituire la bobina della valvola di inversione
Scollegare TAB52 dalla scheda di sbrinamento (MUH-GA60/GA80VB).Chiudere poi il circuito di alimentazione e tentare di fare funzionarel’apparecchio in RAFFREDDAMENTO tramite l’interruttore diFUNZIONAMENTO DI EMERGENZA.
1 Interrompere il circuito di alimentazione2 Dopo 30 secondi richiudere il circuito di alimentazione3 Fare funzionare l’apparecchio in RAFFREDDAMENTO o in
RISCALDAMENTO premendo l’interruttore di FUNZIONAMENTO DIEMERGENZA
4 Fare funzionare l’unità per almeno 1 minuto e poi arrestarla premendoun’altra volta l’interruttore di FUNZIONAMENTO DI EMERGENZA
B
Tra 1 e 2 (MUH-GA50BV)/1 e 3(MUH-GA60/GA80BV)di CN721 dellascheda di sbrinamento ci sono 230 Vin c.a.?
49
Modalità di controllo degli errori di collegamentoD
La SPIA DI FUNZIONAMENTO lampeggia ogni 0,5 secondi o una sola voltaL’unità esterna non funziona
Controllo della bobina della valvola di inversioneC
L’unità funziona in RAFFREDDAMENTO anche se è impostata in RISCALDAMENTO
w Misurare innanzitutto la resistenza della bobina della valvola di inversione per controllare se è interrotta o in cortocircuito
Dopo 3 minuti l’apparecchiofunziona inRAFFREDDAMENTO?
OK
Sì
Sì
No
Sostituire lascheda disbrinamento
No
Sostituire la bobina dellavalvola di inversione
Scollegare TAB52 dalla scheda di sbrinamento. Chiudere poi il circuitodi alimentazione e tentare di fare funzionare l’apparecchio inRISCALDAMENTO tramite l’interruttore di FUNZIONAMENTO DIEMERGENZA.
Tra 1 e 2 (MUH-GA50BV)/1 e 3(MUH-GA60/GA80BV)di CN721della scheda di sbrinamento ci sono230 V in c.a.?
1. Interrompere l’alimentazione e scollegare i cavi di ingresso – uscita dell’unità interna2. Cortocircuitare i morsetti 3 ed N della morsettiera3. Ripristinare l’alimentazione e premere l’interruttore di FUNZIONAMENTO DI EMERGENZA
In FUNZIONAMENTO DI EMERGENZA aicapi di R601 della scheda di sbrinamento cisono 10 V in c.c.(riferirsi a pag. 52 o 53)?
Come per l’ unità interna
Inizio
No
NoTra i capi di R132 della scheda di controllodell’ unità interna ci sono 20 V in c.c.?
• Dare tensione all’unità interna ed all’unità esterna• Premere interruttore FUNZIONAM. EMERGENZA
I collegamenti sono errati, laschi osconnessi?Correggere collegamenti
Sostituire la scheda elettronica dicontrollo dell’unità interna
Ci sono 230 V in c.a. tra i morsetti L edN di TB1 dell’unità esterna?
NoCorreggere i collegamenti dei cavi diinterconnessione tra unità interna ed unitàesterna e di alimentazione dell’unità esterna
Tra i morsetti J205+ e J101- (Mod. MUH-GA50BV) / J101+ e J401- (Modd. MUH-GA60/GA80BV) della scheda disbrinamento ci sono 5 V in c.c.(riferirsi a pag. 52 o 53) ?
Sì
NoSostituire la scheda di sbrinamento
Sì
NoCorreggere i collegamenti tra CN730della scheda di sbrinamento e lamorsettiera dell’unità esterna (.(riferirsia pag. 52 o 53))
Sostituire la scheda di sbrinamento
Sì
Sì
Sì
Dopo 3 minuti le SPIE DI FUNZIONAMENTO dell’unitàinterna lampeggiano (0.5 sec. in ON ed 0.5 sec. inOFF) segnalando un’anomalia di collegamento?w
wLa cortocircuitazione di JPG e di JPS della scheda elettronica di controllodell’unità interna consente la visualizzazione dell’autodiagnosi in 3 secondi
• Interrompere l’alimentazione dell’unità interna• Ripristinare i collegamenti tra unità interna ed
unità esterna
Dare tensione all’alimentazione dell’unità esterna
50
Controllo del termistore esterno
LA SPIA DI FUNZIONAMENTO lampeggia per 6 volteIl termistore dell’unità esterna è in avaria
F
Modalità di controllo della valvola LEVE MUH-GA80VB
La SPIA DI FUNZIONAMENTO lampeggia ogni 10 volteL’unità esterna non funziona né in RAFFREDDAMENTO né in RISCALDAMENTO
w Scollegare i connettori CN661 e/o CN662 dalla scheda di sbrinamento e controllare le caratteristiche dei termistori
Sostituire labobina della LEV
Premere il pulsante di MARCIA/ARRESTO (ON/OFF)dirigendo il telecomando verso l’unità interna ed accertarsiche quest’ultima emetta la nota che conferma la ricezionedel segnale.
La LEV funziona movendosiverso la piena apertura
La bobina è debitamente fissata alcorpo della LEV?
OkLa LEV emette un ticchettio?Toccando la LEV la si sentevibrare?
Le resistenze della bobina dellaLEV sono quelle indicate a pagina46?
No
Sì
Sì
Sì
No
No Fissare debitamente labobina al corpo della LEV
Sostituire la scheda disbrinamento
NOTA: Una volta controllata la LEV fare quanto segue:1. Aprire e poi richiudere il circuito di alimentazione2. Premere il pulsante RESET del telecomando
Chiudere il circuito di alimentazione1 Premere contemporaneamente il pulsante di
SCELTA DELLA MODALITA’, il pulsante TOOCOOL ed il pulsante RESET del telecomando
2 Rilasciare per primo il pulsante RESET (dopo tresecondi verificare l’apparizione di tutte leindicazioni del display)
1 Premere contemporaneamente il pulsantedi SCELTA DELLA MODALITA’, il pulsanteTOO COOL ed il pulsante RESET deltelecomando
2 Rilasciare per primo il pulsante RESET (dopotre secondi verificare l’apparizione di tutte leindicazioni del display)
AMPMCLOCK
C̊
AMPM
Misurare laresistenza tra imorsetti 1 e 2 diCN661
Misurare laresistenza tra imorsetti 3 e 4 diCN662
No
Sì
Sostituire iltermistore
Misurare laresistenza tra imorsetti 1 e 2 diCN662
Collegare CN661 eCN662, dare tensionee premerel’interruttore diFUNZIONAMENTODI EMERGENZA.
La resistenza del termistoreha le caratteristiche conformia quelle indicate a pag. 52o 53?
No
Sì
L’unità funziona peralmeno 10 minuti?
Sostituire la scheda disbrinamento
Ok W.
W Il connettore ha probabilmente un contatto difettoso
Toglieretensione
<MUH-GA80VB>Termistore della temperaturadi mandata RT62
<MUH-GA80VB>Termistore della temperaturaesterna RT63
Termistore di sbrinamento RT61
51
MUH-GA50VB -Scheda di sbrinamento dell’unità esterna
E1
CN711Motore delventilatoreesterno230 V AC
CN721Bobina valvoladi inversione230 V AC
F61Fusibile da 2 A / 250 V
}}
CN661 1-2Termistore di sbrinamento (RT61) (Cfr. pag. 33)
}
12 V in C.C.J204J101
R601Da 5 a 10 Vin C.C.
}--+
5 V in C.C.J205J101 --
+
--+
Alimentazione230 V AC}
NR61Varistore
Cavallotto divariazione delleimpostazioni disbrinamento (JRF,JRG) (Cfr. pag. 35)
}
Spinotto di abbrevia-mento dell’intervallo disbrinamento (JPDS,JPGS) (Cfr. pag. 35)
(Cfr. pag. 47o pag. 50)
10-11. Punti di controllo
Termistore di sbrinamento RT61
Temperatura °C
Res
iste
nza
(kO
hm
)
52
MUH-GA60VB -MUH-GA80VB -Scheda di sbrinamento dell’unità esterna
E1
E1
<MUH-GA80VB>CN662 1-2Termistore dellatemperatura dimandata RT62(Cfr. pag. 52)
<MUH-GA80VB>CN662 3-4Termistore dellatemperatura esternaRT63
<MUH-GA80VB>Connettoredella LEV(CN724)
Connettoredel motoredelventilatore(CN711)
VaristoreNR61
CN7301-3230 V in c.a.}
(Cfr. pag.48 o pag.50)
}
R601 1. (10 V in c.c.)(Cfr. pag. 50)
(Cfr. pag. 48o pag. 50)
J101
J401
+
}Bobinadellavalvola diinversione(CN721
VaristoreNR62
Fusibile da3.15 A / 250 V
Spinotto diabbreviamentodell’intervallodi sbrinamento(JPG1,RT871(Cfr. pag. 35)
} 12 V in c.c.
Cavallotto divariazione delleimpostazioni disbrinamento (JRF,JRG) (Cfr. pag. 35)
}5 V inc.c.
+
+
CN661 1-2Termistore disbrinamentoRT61 (Cfr.pag. 52)
Temperatura °C
Termistore della temperatura di mandata (RT62)
Res
iste
nza
(kO
hm
)
0 10 20 30 40 50 60 70 80 90 100 110 1200
100
200
300
400
500
600
700
800
900
Termistore di sbrinamento RT61Termistore della temperatura esterna (RT63)
-20 -10 0 10 20 30 400
10
20
30
40
50
60
70
80
90
100
Temperatura °C
Res
iste
nza
(kO
hm
)
53
10-12. Punti di controlloMSH-GA50VB - MSH-GA60VB - MSH-GA80VB -Scheda elettronica di controllo dell’unità interna
E1E1E1
Alimentazione delmotore del ventilatore
Fusibile F11250 V C.A. - 3.15 A
} Alimentazione a230 V in c.a.
+} 5 V in c.c.
Termistore principaledella batteria internaRT12
Punto di abbreviamentotemporizzazioni(JPS, JPG)(cfr. pag. 33)
Interruttore delfunzionamento diemergenza
+}
12 V in C.C.
Termistore dellatemperatura ambienteRT11
Abbandono della funzione di“Riavviamento Automatico”:Saldare il cavallotto a JR07(Cfr. pag. 34)
Mod. MSH-GA80VBTermistoresecondario dellabatteria interna RT13
R132
Scheda del ricettore dei segnali
Termistore della batteria interna (RT12 princ.) (RT13 sec.)Termistore della temperatura ambiente (RT11)
Res
iste
nza
(kO
hm
)
Temperatura °C
(1) Fare scorrere la protezione e controllare se il morsetto hao non ha una leva di blocco
1 Far scorrere laprotezione.
2 Tirare il cavo espingere la leva diblocco.
1 Afferrare la protezione edestrarre lentamente il cavo
Se i morsetti sono dotati di meccanismo di sblocco essi devono essere sbloccati come di seguito precisato.I morsetti possono avere due meccanismi di blocco [(1) o (2)].I morsetti privi di meccanismo di blocco possono essere allentati tirando il capocorda.Controllare sempre il tipo di morsetto con il quale si ha a che fare.
<Modalità di sblocco dei morsetti>
Connettore
Protezione
Leva di blocco
54
11-1.MSH-GA50VB - MSH-GA60VB - MSH-GA80VB -UNITA’ INTERNA
PROCEDURA OPERATIVA FOTO E FIGURE
Foto 1
Foto 2
Pannello frontale
Vite dellafascetta di V.A.
Scheda dicontrollodell’unitàinterna
Connettore delservomotoredel deflettore
Connettore delmotore delventilatore
Vite del cavo di terra
Viti
Vite di fissaggiodel coperchio delquadro elettrico
Alloggiamentodi R.L.
Vite dellamorsettiera
Scheda delricettore
E1E1
PROCEDURA DI DISASSIEMAGGIO11
(2) Il morsetto è dotato di meccanismo di blocco
E1
2. Smontaggio della scheda elettronica di controllo, della schedadel display e della scheda del ricettore(1) Smontare il pannello frontale (Cfr. il punto 1).(2) Smontare il coperchio.del quadro elettrico dopo averne tolto
le viti di fissaggio.(3) Togliere la fascetta di V.A. dopo averne tolto la vite di fissaggio.(4) Togliere la vite della morsettiera.(5) Togliere la vite del cavo di terra(6) Scollegare tutti i connettori ed i capicorda della scheda
elettronica di controllo.(7) Togliere l’alloggiamento di R.L.(8) Smontare la scheda elettronica di controllo(9) Aprire l’alloggiamento di R.L. e la scheda del ricettore e
dell’indicatore spia di alimentazione.
1. Smontaggio del pannello frontale(1) Smontare i copri vite del pannello frontale.
Togliere le viti(2) Abbassare con cautela il pannello e disimpegnare i ganci di
sommità.
55
PROCEDURA OPERATIVA FOTO E FIGURE
Foto 4
Foto 6
Servomotore del deflettore
Termistoredellabatteriainterna
Foto 3
Viti di fissaggio del motore del ventilatore
Viti di fissaggiodel lato sinistrodella batteria
Viti di fissaggiodel servomotore
Viti di fissaggiodelservomotore
Servomotoredel deflettore
Viti del quadroelettrico
Viti del cavo di terra
Foto 5
Foto 7
Foto 8
Coperchio
Paraacqua
Viti delcoperchiodel quadroelettrico
3. Smontaggio del quadro elettrico(1) Smontare il pannello frontale (Cfr. il punto 1)(2) Smontare il coperchio del quadro elettrico (Cfr. il punto 2)(3) Scollegare il connettore del termistore della batteria interna.(4) Scollegare dalla scheda interna i connettori del motore (CN211
e CN121) ed il connettore del servomotore del deflettore(CN151).
(5) Togliere la vite del cavo di terra.(6) Staccare dal quadro elettrico i cavi del motore del ventilatore
ed il termistore della batteria interna.(7) Staccare dalla parte inferiore del quadro elettrico i cavi del
servomotore del deflettore.(8) Togliere la vite di fissaggio del quadro elettrico e smontare
quest’ultimo
4. Smontaggio dei servomotore dei deflettori(1) Smontare il pannello frontale (Cfr. il punto 1).(2) Smontare il coperchio del quadro elettrico (Cfr. il punto 2)(3) Scollegare i cavi del servomotore del deflettore (Cfr. il punto 3)(4) Togliere l’alloggiamento di R.L.(5) Staccare il flessibile di drenaggio dal suo attacco e poi smontare
quest’ultimo.(6) Togliere le viti di fissaggio inferiori e superiori dei servomotori
e scollegare il connettore(7) Smontare i servomotori.
5. Smontaggio del ventilatore e del suo motore(1) Smontare il pannello frontale (Cfr. il punto 1)(2) Smontare il quadro elettrico (Cfr. il punto 3)(3) Estrarre il flessibile di drenaggio dal boccaglio e poi
smontare l’assieme di quest’ultimo.(4) Smontare il para acqua(5) Sfilare ed estrarre il coperchio(6) Togliere la vite a Brugola dal ventilatore.(7) Togliere le viti di fissaggio del motore e smontarlo facendo
attenzione a non lasciarlo cadere(8) Togliere le viti di fissaggio del lato sinistro della batteria.(9) Sollevare il lato sinistro della batteria(10)Smontare il ventilatore
PROCEDURA OPERATIVA FOTO E FIGURE
11-2. UNITA’ ESTERNAMUH-GA50VB - E1
Foto 1
Foto 3
Foto 2
Viti difissaggiodellacarrozzeria
Viti difissaggiodellacarrozzeria
Pannello diservizio
Morsettiere
Pannello dei Relay
Scheda disbrinamento
Vite di fissaggiodel pannellodei relay
Vite di fissaggiodel pannello deirelay
1. Smontaggio della carrozzeria(1) Togliere le viti di fissaggio della carrozzeria(2) Afferrare la carrozzeria da entrambi i lati e smontarla.
2. Smontaggio della scheda di sbrinamento(1) Smontare il pannello di servizio e la carrozzeria.(2) Scollegare tutti i connettori ed i morsetti della scheda di
sbrinamento.(3) Smontare la scheda di sbrinamento.
56
56
57
PROCEDURA OPERATIVA FOTO E FIGURE
Foto 5
Coperchio della morsettiera
Compressore
Linea dimandata
Linea diaspirazione
Dadi di fissaggiodel compressore
Foto 4
Girante
Viti di fissaggiodel motore
Fascette fissacavi
MotoreDado dellagirante
Viti di fissaggiodel motore
3. Smontaggio del motore del ventilatore esterno(1) Smontare la carrozzeria (Cfr. il punto 1)(2) Togliere il dado della girante e smontare la giranteNOTA: La girante deve essere smontata nella direzione di
rotazione.Per rimontarla è indispensabile allineare la marcatura sullagirante ed il taglio sul mozzo del ventilatore.
(3) Togliere le fascette fissacavi e scollegare il motore(4) Togliere le viti di fissaggio del motore(5) Smontare il motore del ventilatore.
4. Smontaggio del compressore(1) Smontare la carrozzeria (Cfr. il punto 1)(2) Smontare il pannello dei relay(3) Smontare il feltro fonoassorbente(4) Smontare il coperchio della morsettiera del compressore(5) Scollegare i cavi dai morsetti dal compressore(6) Recuperare il refrigerante contenuto nel circuito frigorifero.(7) Dissaldare l’attacco della linea di mandata(8) Dissaldare l’attacco della linea di aspirazione(9) Togliere i dadi di fissaggio del compressore(10)Smontare il compressore
NOTE● Prima di applicare calore per dissaldare gli attacchi è indispensabile
estrarre tutto il refrigerante fino a che il vacuometro non segniuna pressione pressoché nulla.
● Applicare calore solo se è possibile sfiatare l’aumento di pressioneche ne segue.
58
11-3. UNITA’ ESTERNAMUH-GA60VB - MUH-GA80VB - E1E1
NOTE : Le foto sono riferite al modello MUH-GA80VBLe caratteristiche del modello MUH-GA60VB sono analoghe
PROCEDURA OPERATIVA FOTO E FIGURE
Foto 2
Foto 1
Foto 3
Viti di fissaggio delpannello superiore
Viti di fissaggio della carrozzeria
Viti difissaggiodellacarrozzeria
Viti difissaggiodel pannellosuperiore
Viti di fissaggio delsupporto del motore
Viti di fissaggio del pannello di posteriore
Viti difissaggiodelpannellofrontale
Viti di fissaggio del pannello di servizio
Viti difissaggiodel coperchiodellevalvole
Viti di fissaggiodel pannellodi posteriore
Foto 4 Scheda di sbrinamento
Viti delpannellodei relay
Viti del pannellodei relay
Morsettiere
1. Smontaggio della carrozzeria(1) Togliere le viti di fissaggio del pannello di servizio(2) Togliere le viti di fissaggio del pannello superiore(3) Togliere le viti di fissaggio del coperchio delle valvole(4) Smontare il pannello di servizio(5) Smontare il pannello di superiore.(6) Smontare coperchio delle valvole.(7) Togliere le viti di fissaggio del pannello frontale(8) Smontare il pannello frontale.(9) Togliere le viti di fissaggio del pannello posteriore(10)Smontare il pannello posteriore
2. Smontaggio della scheda di sbrinamento(1) Smontare il pannello di servizio e la carrozzeria.(2) Scollegare tutti i connettori ed i morsetti della scheda di
sbrinamento.(3) Smontare la scheda di sbrinamento.
Foto 5
Viti di fissaggio del motore
Viti di fissaggiodel motore
Dadodellagirante
Girante
Dadi di fissaggiodel compressore
59
Foto 6
Linea diaspirazione
Linea di mandata
Coperchio dellamorsettiera
PROCEDURA OPERATIVA FOTO E FIGURE
4. Smontaggio del compressore(1) Smontare la carrozzeria (Cfr. il punto 1)(2) Smontare il pannello dei relay(3) Smontare il feltro fonoassorbente(4) Smontare il coperchio della morsettiera del compressore(5) Scollegare i cavi dai morsetti dal compressore(6) Recuperare il refrigerante contenuto nel circuito frigorifero.(7) Dissaldare l’attacco della linea di mandata(8) Dissaldare l’attacco della linea di aspirazione(9) Togliere i dadi di fissaggio del compressore(10)Smontare il compressore
NOTE● Prima di applicare calore per dissaldare gli attacchi è indispensabile
estrarre tutto il refrigerante fino a che il vacuometro non segniuna pressione pressoché nulla.
● Applicare calore solo se è possibile sfiatare l’aumento di pressioneche ne segue.
3. Smontaggio del motore del ventilatore esterno(1) Smontare la carrozzeria (Cfr. il punto 1)(2) Togliere il dado della girante e smontare la giranteNOTA: La girante deve essere smontata nella direzione di
rotazione.Per rimontarla è indispensabile allineare la marcatura sullagirante ed il taglio sul mozzo del ventilatore.
(3) Togliere le fascette fissacavi e scollegare il motore(4) Togliere le viti di fissaggio del motore(5) Smontare il motore del ventilatore.
MSH-GA50 VB -
(WH)E1
MSH-GA60 VB -
(WH) E1
MSH-GA80VB -
(WH)E1
E02 527 970E02 685 234E02 888 000E02 408 142E02 685 067E02 888 010E02 534 100E02 685 975E02 891 007
PIASTRA DI SOSPENSIONEINVOLUCRO (WH)ASSIEME PANNELLO FRONTALE (WH)GANCIOCOPRIVITE (WH)GRIGLIA (WH)FILTRO ALLA CATECHINASPIGOLO INFERIORE DESTROPANNELLO SPIE
Simbolonello
schemaelettrico
Quantità/unità
Compresi 4, 5 e 64 pezzi/confezione3 pezzi/confezione
NoteCod.NO. Nome del Componente
123456789
111431211
111431211
111431211
I componenti il cui numero è attorniato da un cerchio non sono visibili in figura
60
MSH-GA50VB - (WH)MSH-GA60VB - (WH)MSH-GA80VB - (WH)12-1. COMPONENTI STRUTTURALI
DELL’UNITA’ INTERNA
E1
E1
E1
12-2. BATTERIA DELL’UNITA’ INTERNA
2
4
5
7
6
1
10
8
11
12
3
GANCIO
COPRIVITE
12-2. BATTERIA
12-1. COMPONENTI STRUTTURALI DELL’UNITA’ INTERNA
Componentioptional(Cfr. UltimaCopertina)
E02 891 620E02 893 620E02 179 667E02 138 666E02 151 667E02 527 667
BATTERIA DELL’UNITA’ INTERNABATTERIA DELL’UNITA’ INTERNAATTACCO GASATTACCO GASATTACCO LIQUIDOATTACCO LIQUIDO
{12.7{15.88{6.35{9.52
10
11
12
1
11
1
1
1
1
1
1
ELENCO DEI COMPONENTI12
61
I componenti il cui numero è attorniato da un cerchio non sono visibili in figura
MSH-GA50VB - (WH)MSH-GA60VB - (WH)MSH-GA80VB - (WH)E1
E1
E1
12-4. TELECOMANDO EACCESSORI
12-3. UNITA’ INTERNA COMPONENTI FUNZIONALIED ELETTRICI
23 24
12-3. COMPONENTI FUNZIONALI ED ELETTRICI DELL’UNITA’ INTERNA
19
2
6
4
7
13
5
3
12
1
18
20
10
179
CUSCINETTO
TERMISTORE DELLATEMPERATURAAMBIENTE
VARISTOREFUSIBILE
12-4. TELECOMANDO E ACCESSORI
8 15 16
11
14
E02 527 302E02 408 509E02 001 504E02 408 702E02 527 235E02 685 040E02 685 041E02 127 382E02 817 385E02 527 034E02 817 300E02 527 300E02 448 303E02 408 303E02 817 333E02 527 333E02 528 329E02 527 468E02 891 452E02 892 452E02 893 452E02 527 308E02 819 375E02 749 307E02 527 307E02 528 034E02 529 034
12345678910
11
1213
14
1516
17
1819
20
2122
GIRANTE DEL VENTILATORESUPPORTO DEL CUSCINETTOCUSCINETTOFLESSIBILE DI DRENAGGIOBOCCAGLIO (WH)DEFLETTORE SUPERIORE (WH)DEFLETTORE INFERIORE (WH)FUSIBILEVARISTORELEVISMO DEI DEFLETTORIASSIEME DEL MOTOREASSIEME DEL MOTORESERVOMOTORE DEFLETTORI VERT.SERVOMOTORE DEFLETTORI ORIZZ.FASCETTA DI FISSAGGIO DEL MOTOREFASCETTA DI FISSAGGIO DEL MOTORESCHEDA DI INDICAZIONESCHEDA DI RICEZIONESCHEDA ELETTRONICA DI CONTROLLOSCHEDA ELETTRONICA DI CONTROLLOSCHEDA ELETTRONICA DI CONTROLLOTERMISTORE TEMPERATURA AMBIENTEMORSETTIERATERMISTORE BATTERIA INTERNATERMISTORE BATTERIA INTERNASUPPORTO DESTRO DEL SERVOMOTORESUPPORTO SINISTRO DEL SERVOMOTORE
Simbolonello
schemaelettrico
Quantità/unità
3.15A
DESTRA - SINISTRASU - GIÙ
NoteCod.NO. Nome del Componente
F11NR11
MFMF
MV2MV1
RT11TB
RT12RT12, RT13
11111111111
211
11
1
111
11
1111111111
121
111
111
111
11111111111
211
111
111
11
MSH-GA50 VB -
(WH)E1
MSH-GA60 VB -
(WH)E1
MSH-GA80 VB -
(WH)E1
RC4V32 -Gommini compresi
RIAVVIAMENTO AUTOM.No. 16 compresoRIAVVIAMENTO AUTOM.No. 16 compresoRIAVVIAMENTO AUTOM.No. 16 compreso
RC4V40 -Gommini compresi
2324
E02 529 426E02 527 083
TELECOMANDOSTAFFA DEL TELECOMANDO
11
11
11
KM04A
62
I componenti il cui numero è attorniato da un cerchio non sono visibili in figura
1
20
4
13
12
11
10
987653
2
MUH-GA50VB -12-5. UNITA’ ESTERNE - COMPONENTI FUNZIONALI, ELETTRICI E STRUTTURALI
E1
TERMISTOREDI SBRINAMENTO
21
1416
1819
15 17
Simbolonello
schemaelettrico
Quantità/unità
MUH-GA50VB - NoteCod.E1
E02 817 233E02 817 232E02 817 521E02 643 630E02 141 501E02 139 515E02 075 506E02 817 900E02 817 290E02 817 661E02 820 662E02 817 245E02 891 961E02 888 353E02 816 301E02 890 383E02 891 451E02 817 374E02 821 374E02 820 310E02 817 009E02 139 936E02 340 936E02 414 936E02 095 382E02 821 490E02 891 642E02 820 385
123456789101112131415161718192021
22
23242526
PANNELLO POSTERIORECARROZZERIAPROTEZIONE DEL VENTILATOREBATTERIAGIRANTE DEL VENTILATORESUPPORTO DEL MOTORESERIE DI GOMMINI DI SUPPORTO COMPRESSORECOMPRESSOREBASAMENTOVALVOLA DI INTERCETTAZIONE DEL GASVALVOLA DI INTERCETTAZIONE DEL LIQUIDOPANNELLO DI SERVIZIOVALVOLA DI INVERSIONECONDENSATORE DEL COMPRESSOREMOTORE DEL VENTILATOREFILTRO ANTI DISTURBISCHEDA DI SBRINAMENTOMORSETTIERAMORSETTIERATERMISTORE DI SBRINAMENTOMANIGLIACAPILLARECAPILLARECAPILLAREFUSIBILEBOBINA DELLA VALVOLA DIINVERSIONEVALVOLA DI RITEGNO
MC
C1MF
DSAR
TB1TB2RT61
F6121S4
NR61
3 GOMMINI / SERIERN196VHSHT
{12.7{ 6.35
40+/440V ACRA6V50 -
3P2P
{3.0✕ {1.6✕ 750{3.0✕ {1.6✕ 450{3.0✕ {1.6✕ 300250V / 2A
NO.
1111113111111111111112111111
Nome del Componente
3
23
16
12
1
1513 14
2
4
5
6
7
8
9
10
11
17
18
19
20
21
22
24252627
63
MUH-GA60VB -12-6. UNITA’ ESTERNE - COMPONENTI FUNZIONALI, ELETTRICI E STRUTTURALI
E1
MUH-GA60VB - E1
Simbolonello
schemaelettrico
Quantità/unità
NoteCod.NO. Nome del Componente
E02 819 297E02 821 630E02 892 301E02 214 501E02 821 290E02 819 232E02 819 009E02 819 521E02 679 961E02 821 490E02 821 310E02 527 506E02 821 900E02 819 661E02 821 662E02 819 650E02 819 245E02 890 383E02 821 374E02 817 374E02 895 351E02 892 451E07 012 340E02 889 353E02 819 233E02 817 009E02 726 515E02 127 382E02 336 385E02 891 642E02 892 936
12345678910111213141516171819202122232425262728293031
PANNELLO SUPERIOREBATTERIAMOTORE DEL VENTILATOREGIRANTE DEL VENTILATOREBASAMENTOCARROZZERIAMANIGLIAPROTEZIONE DEL VENTILATOREVALVOLA DI INVERSIONEBOBINA DELLA VALVOLA DI INVERSIONETERMISTORE DI SBRINAMENTOSERIE GOMMINI SUPPORTO COMPRESSORECOMPRESSOREVALVOLA INTERCETTAZIONE DEL GASVALVOLA INTERCETTAZIONE DEL LIQUIDOCOPERCHIO DELLE VALVOLEPANNELLO DI SERVIZIOFILTRO ANTI DISTURBIMORSETTIERAMORSETTIERACONDENSATORE MOTORE VENTILATORESCHEDA DI SBRINAMENTOCONTATTORE DEL COMPRESSORECONDENSATORE DEL COMPRESSOREPANNELLO POSTERIORE (ESTERNO)MANIGLIASUPPORTO DEL MOTOREFUSIBILEVARISTOREVALVOLA DI RITEGNOCAPILLARE
RA6V85-
4RUBBERS/SETNN29VBAHT{15.88{6.35
2P3P3.0+/440V AC
55+/440V AC
250V/3.15A
{3.0x{2.0x750
MF
21S4RT61
MC
DSARTB2TB1C2
52CC1
F61NR61
1111111111141111111111111111112
64
MUH-GA60VB -12-6. UNITA’ ESTERNE - COMPONENTI FUNZIONALI, ELETTRICI E STRUTTURALI
E1
I componenti il cui numero è attorniato da un cerchio non sono visibili in figura
4
24
17
13
1
1614 15
2
5
6
7
8
9
10
11
12
18
19
20
21
22
23
25262728
3
2
65
MUH-GA80VB -12-6. UNITA’ ESTERNE - COMPONENTI FUNZIONALI, ELETTRICI E STRUTTURALI
E1
MUH-GA80VB - E1
Simbolonello
schemaelettrico
Quantità/unità
NoteCod.NO. Nome del Componente
E02 819 297E02 819 309E02 822 630E02 819 301E02 214 501E02 819 290E02 819 232E02 819 009E02 819 521E02 679 961E02 821 490E02 821 310E02 527 506E02 819 900E02 819 661E02 822 662E02 819 650E02 819 245E02 890 383E02 821 374E02 817 374E02 890 351E02 893 451E02 890 340E02 890 353E02 819 233E02 817 009E02 726 515E02 819 640E02 819 493E02 127 382E02 336 385E02 214 386E02 822 936
12345678910111213141516171819202122232425262728293031323334
PANNELLO SUPERIORETERMISTOREBATTERIAMOTORE DEL VENTILATOREGIRANTE DEL VENTILATOREBASAMENTOCARROZZERIAMANIGLIAPROTEZIONE DEL VENTILATOREVALVOLA DI INVERSIONEBOBINA VALVOLA DI INVERSIONETERMISTORE DI SBRINAMENTOSERIE GOMMINI DI SUPPORTO COMPRESSORECOMPRESSOREVALVOLA INTERCETTAZIONE DEL GASVALVOLA INTERCETTAZIONE DEL LIQUIDOCOPERCHIO DELLE VALVOLEPANNELLO DI SERVIZIOFILTRO ANTI DISTURBIMORSETTIERAMORSETTIERACONDENSATORE MOTORE VENTILATORESCHEDA DI SBRINAMENTOCONTATTORE DEL COMPRESSORECONDENSATORE DEL COMPRESSOREPANNELLO POSTERIORE (ESTERNO)MANIGLIASUPPORTO DEL MOTOREVALVOLA DI ESPANSIONEBOBINA VALVOLA DI ESPANSIONEFUSIBILEVARISTOREFILTRO ANTI DISTURBI CZCAPILLARE
MANDATA, TEMP. ESTERNA
RA6V75-
4 GOMMINI / SERIENN37VAAHT{15.88{9.52
2P3P4.0+/440V AC
60+/440V AC
250V/3.15A
{3.6x{2.4x50
RT62, RT63
MF
21S4RT61
MC
DSARTB2TB1C2
52CC1
LEVF61
NR61CZ
1111111111114111111111111111111111
66
MUH-GA80VB -12-7. UNITA’ ESTERNE - COMPONENTI FUNZIONALI, ELETTRICI E STRUTTURALI
E1
I componenti il cui numero è attorniato da un cerchio non sono visibili in figura
Simbolonello
schemaelettrico
Quantità/unità
NoteCod.NO. Nome del Componente MUH-GA50VB - E1
MUH-GA60VB - E1 E1
MUH-GA80VB -
E02 817 704E02 444 705E02 444 706
1
2
TASCA DI DRENAGGIOTAPPO DEL DRENAGGIOTAPPO DEL DRENAGGIO
[33[16
121
12
12
MUH-GA50VB -MUH-GA60VB -MUH-GA80VB -12-8. ACCESSORI
E1
E1
E1 1 2
67
68
13
FILTRO DEPURATORE● Il FILTRO DEPURATORE grazie ad un particolare effetto elettrostatico intercetta le polveri di granulometria superiore a
0,01 µm.● La sua durata normale è di 4 mesi, ma deve essere sostituito subito se si sporcasse prima.● L’intasamento del FILTRO DEPURATORE può ridurre le prestazioni del climatizzatore e causare formazioni di brina sulla
bocca di mandata dell’aria.● Il FILTRO DEPURATORE non deve essere mai riutilizzato, neppure dopo averlo lavato.● Il FILTRO DEPURATORE non deve essere mai smontato o rimontato mentre il climatizzatore sta funzionando.
Modello Codice
MAC-1700FTMSH-GA50VB - E1
MSH-GA60VB - E1
MSH-GA80VB - E1
Filtro depuratore (tipo a soffietti bianchi)
OPTIONAL DISPONIBILI
CC Copyright 2004 MITSUBISHI ELECTRIC ENGINEERING CO.,LTDDistributed in Oct. 2004.Printed in ITALY