BayTech Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnetBuild Logical and Functional Views of RPC’s in Remote LocationsSupports Equipment with Single or Redundant Power SuppliesProvides easy “Click Through” control of RPC’s anywhereDisplays Alerts for All or Individual RPC’sNotification of Alert via EmailGraphically Displays Power Environment Per RPC
Global Power Management
Discovers BayTech devices on existing subnet Global Power Management detects BayTech SNMP devices on the local subnet or can be given IP’s to discover remote BayTech SNMP devices.
Once discovered a status screen displays the controllers and associated RPC’s with their receptacles.
GPM Software for BayTech Remote Power Controllers
Automatic Discovery of BayTech SNMP Devices
Discover controllers on the same subnet, or enter the IPs of remote controllers
Status Screen for Discovered BayTech Controllers
Status screen provides a snap shot of all BayTech power solutions. Controllers, RPC’s and Outlets are displayed. On/Off, reboot and status funtions are supported by a simple right click of the mouse.
Global Power Management
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
One of the power features of GPM is the ability to group equipment in many ways. Whether you need to view a data center server cabinet by location or view all your Unix servers together GPM lets you group any way you need
GPM Software for BayTech Remote Power Controllers
Build Logical Views of RPC’s in Remote Locations
Tree View shows a logical or functional view of a data center. Equipment can be grouped any way as well as many ways.
Global Power Management
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
Supports Equipment with Single or Redundant Power Supplies
Through an easy to use drag and drop interface you can assign device names(servers) for single or multiple receptacles. Receptacles can be assigned from any active controller in the Power Management Network.
A single device name can support any number of receptacle so if you want to make a group of devices which are turned off during critical power outages you can simply do this with the click of a button.
Power sequence can be assigned to devices with multiple receptacles. This is useful for bringing up device power supplies in a desired sequence.
GPM Software for BayTech Remote Power Controllers
Supports Equipment with Single or Redundant Power Supplies
Supports redundant power sources. Assign multiple receptacles to any device.
Simply drag discovered receptacles from outlet list to device name.
Power Sequence any Supplies on any Device
GPM allows you to sequence power supplies in any order. Delays can be set between operations.
Global Power Management
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhereSimply right click on any device name with an assigned receptacle and you can turn on/off or reboot that device. The option to remove or change the name of this device is provided at this point.
GPM Software for BayTech Remote Power Controllers
Provides easy Click Through control of RPC’s anywhere
Simply right click on defined equipment and you have the option(s) to turn on/off or reboot the equipment
Global Power Management
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
GPM maintains a list of all alerts received from RPC devices being monitored. A clicked alert will trigger GPM’s tree view to drill down to the specific devices causing the alert.
GPM Software for BayTech Remote Power Controllers
Displays Alerts for All or Individual RPC’s
The “Alerts” view displays all SNMP traps received for all controllers monitored by GPM. Selecting the alert automatically navigates the user to physical location within the organization.
Global Power Management
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
GPM allows a user to monitoring and receive alarms based on the BayTech SNMP mib. Emails and associated messages can be sent to individuals or groups of individuals.
The GPM configuration provides a means to pick and choose which alerts will be flagged for notification.
GPM Software for BayTech Remote Power Controllers
Environmental Alarm Thresholds Set per RPC
Current, voltage and temperature thresholds can be set for every circuit in your in your data center. Based on thresholds and trap settings NOC personal can be notified via email when circuits reach capacity.
Alerts are Customized Based on Preset Conditions
To: [email protected]: Global Power Management Alert !!! -- Please Review Immediately *--ALERT--**--ALERT--**--ALERT--**--ALERT--**--ALERT--**--ALERT--* Baytech Power Management Message:
Subject :Outlet(s) turned OFFSent To :[email protected],[email protected] Date/Time :20020827Controller Name :NORLINX CONTROLLER IN CABINET 1 Controller Ip :66.83.91.37 Power Strip Name :BT RPC4-1001092 Location :Raleigh Data CenterOutlet(s) Name :(1) - alexnorth008329 (2) – Server 1 (3) - Server 2 (4) - Outlet 3 (5) - Outlet 4 (6) - Outlet 5 (7) - Outlet 6 (8) - Outlet 7 (9) – Outlet 8 (10) – Outlet 9 (11) – Outlet 10 (12) - Outlet 11 (13) - Outlet 12 (14) - Outlet 13 (15) - Outlet 14 (16) - Outlet 15
*--ALERT--**--ALERT--**--ALERT--**--ALERT--**--ALERT--**--ALERT--*
Email Alerts Sent to Single or Multiple Recipients
Global Power Management
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
Graphically Displays Power Environment Per RPC
GPM graphically displays the circuits power environment. Prior to adding devices NOC managers can easily check the capacity of a circuit, then make an informed decision on whether to add more equipment.
GPM Software for BayTech Remote Power Controllers
Graphically Displays Power Environment Per RPC
Power environment is displayed through graphical and textual displays
Global Power Management
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
Graphically Displays Power Environment Per RPC
GPM Software for BayTech Remote Power Controllers
GPM graphically displays the circuits power environment. Prior to adding devices NOC managers can easily check the capacity of a circuit, then make an informed decision on whether to add more equipment.
Global Power Management
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
Graphically Displays Power Environment Per RPC
Provides Graphical Reporting for any segment or organization node.
Exposes Enterprise Security Model for Access to Power Control
GPM Software for BayTech Remote Power Controllers
See power utilization in any segment of the data center by simply clicking the segment. For example clicking on IBM Cabinet1 would yield combined power utilization for that cabinet. This could be extended to the entire Raleigh segment, again by simply clicking on Raleigh.
Power Utilization
Graph power, voltage, current, max current and temperature over a specified time interval. Great for detecting power and temperature trends within any segment of the datacenter or organization.
Power Utilization over Time
Expose Enterprise Security and Control Access.
WinNT/2000 Login
WinNT/2000 Domains exposed to the power infrastructure. Administrators can drag users or groups to any level within the organizational structure.
User and groups can be assigned specific operations.