    1www.firedos.de

    FireDoswall hydrant cabinets WHS130

    Wall hydrant cabinet with hose reelWall hydrant cabinet with collapsible hose

    Wall hydrant cabinet

  • 8/6/2019 WHS 2011 en - EWH-001

    2/4

    2www.firedos.de

    Illustrations and explanatory notes

    Figure 1 Figure 2 Figure 3

    FireDoswall hydrant cabinet WHS130 withcollapsible hose

    The well-proven FireDosadmixing system FD130 forextinguishing water flow rates of up to 130 l/min isthe centrepiece of the system. The admixture rate iseither 1% or 3%.

    The version of the wall hydrant cabinet shown abovehas a collapsible hose type C-42 with a length of 20metres fitted. The delivery also includes a regular jet

    nozzle as standard.The optionally available foam concentrate can besupplied in standard tanks of 20 or 60 litres volume(the above illustration shows 20 litres).

    The connection to the water supply offers a femalethread 1 .

    FireDoswall hydrant cabinet WHS130 with hoseon reel

    Design as already described on the left, but with ahose type S-25, length 30 metres on a hose reel.

    The above illustration shows the optionally availablefoam concentrate in a 60 litres standard tank.

    Base frame

    Instead of being wall mounted the FireDoswallhydrant cabinets can also stand on an optionallyavailable base frame, which is made of stainlesssteel.

    http://0.0.0.0/
  • 8/6/2019 WHS 2011 en - EWH-001

    3/4

    3www.firedos.de

    Figure 4 Figure 5

    Figure 6 Figure 7

    Figures 4 to 7

    Jet nozzles

    The FireDoswall hydrant cabinets are availablewith different jet nozzles.

    Figure 4: Regular jet nozzle, included in deliveryat no extra price

    Figure 5: Optionally available mediumfoam nozzle

    Figure 6: Optionally available adjustable hollowjet nozzle

    Figure 7: Foam attachment for the adjustablehollow jet nozzle shown in figure 6

    http://0.0.0.0/
  • 8/6/2019 WHS 2011 en - EWH-001

    4/4

    4www.firedos.de

    Figure 8 Figure 9 Figure 10

    Backflow preventer PN10

    Depending on the connection situation of theFireDoswall hydrant cabinet, a backflow preventermight be necessary to prevent the return flow of theextinguishing water.

    Important: When the FireDoswall hydrant cabinet issupposed to be connected to the public waternetwork, current local technical regulations must beobserved.

    For operating pressures up to 10 bar.

    Pipe disconnector PN16

    Depending on the connection situation of theFireDoswall hydrant cabinet, a pipe disconnectormight be necessary to prevent the return flow of theextinguishing water.

    Important: When the FireDoswall hydrant cabinet issupposed to be connected to the public waternetwork, current local technical regulations must beobserved.

    For operating pressures up to 16 bar.

    Pressure reducer PN25

    To adjust the operating pressure of the water supplyto the maximum permissible pressure of the FireDoswall hydrant cabinet.