Volume Scan
description
Transcript of Volume Scan
Volume Scan
福田 努 (Tsutomu Fukuda)
Nagoya-univ.
Event Brick# CC/NC Stop Plate
179264151 20122 CC PL10
180277945 33540 CC PL56
178684089 36564 NC PL38
179351516 01429 CC PL47
181543007 53486 CC PL25
182245114 40953 CC PL46
187381090 40742 CC PL54
7 Event located at Nagoya
Volume Scan
Volume Scan DATA set
• After location, Volume Scan .• Volume Scan Area is 1cm x 1cm from VTX point.• Scanning 5plates upper VTX Plate and 10plates below VTX Plate.
VTX Plate5plates
10plates
1cm
1cm
Scanning time (first 4event)OPERA ECC SUTS scanning
0
300
600
900
1200
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
plate
time
(sec
)
scanningplate changescanningplate chagescanningplate changescanningplate change
Scanning time/PL ~ time of PLATE set/PL
VTXconfirm Volume Scan
0
100
200
300
400
500
600
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16plate
sec
plate change- 1scanning- 1plate change- 2scanning- 2plate change- 3scanning- 3
Scanning time (later 3event)
1min
I change stream of PLATE set → time of PLATE set → ~1min/PL
• Penetrate cosmic (Event 17868408 Brick#36564 )PL28,29,30 – PL41,42,43 : 155Trk/cm2 (Nseg>9 -> BG=0)
Angle distribution (PL28 or 29 or 30)
~1cm
~1cm
About DATA quality
• Efficiency (Event 17868408 Brick#36564 )Reject low momentum Trks (top angle – bottom angle < 70mrad)155Trks -> 132Trks
Average of Fillfactor = 0.811 Average of Efficiency = 0.80 (Tracking eff x Connection eff)
Estimated total # of CR ~ 130/cm2
(> ~ 500MeV/c)
Transportation alignment
PL28,29,30 – PL41,42,43 : 334Trk/cm2(BG=0)
Angle distribution (PL28 or 29 or 30) Efficiency
Average of Fillfactor = 0.652 Average of Efficiency = 0.59 (Tracking eff x Connection eff) Estimated total # of CR ~ 890/cm2 (> ~ 500MeV/c)
(Event 17868408 Brick#36564 )
Short Summary (1)
Event Brick# # of Scan Plates
eff (ECC)
# of CR ( /cm2)
eff( 輸送
時 )# of CR ( /cm2)
179264151 20122 15 ( PL01-PL15 )
0.82 ~150 0.64 ~1000
180277945 33540 12 ( PL46-PL57 )
0.89 ~190 0.69 ~1060
178684089 36564 16 ( PL28-PL43 )
0.80 ~130 0.59 ~890
179351516 01429 16 ( PL37-PL52 )
0.79 ~140 0.59 ~860
181543007 53486 16 ( PL15-PL30 )
0.80 ~90 0.57 ~710
182245114 40953 16 ( PL36-PL51 )
187381090 40742 14 ( PL44-PL57 )
0.85 ~130 0.69 ~1230
BG Trk rejection
• Virtual Erase
• Linklet Quality check
• BaseTrk Quality check
Virtual Erase
• Delete BaseTrk of Linklet in transportation.
• Trk in transportation is ~1000 本 /PL
• Rate of delete of trk at ECC alignment : ~ 0.2%
Linklet Quality check• VPH sum of Linklet(4surface)
Penetrate TrkVPH sum
BG TrkVPH sum
BG Trk;XXXOXXOXXXChain
Penetrate Trk
Angle difference
Angle difference
BaseTrk Quality check• Angle difference (MicroTrk Angle – BaseTrkAngle) vs VPHsum
(2surface)
penetrateTrk BG Trk
Vertical axis : (dax1)2+(day1)2+(dax2)2+(day2)2
cut cut
Short Summary (2)
Event Brick# # of Scan
Plates
eff (ECC)
Before BG rejection
eff (ECC)
After BG rejcetion
#of BaseTrk/PL(after /before)
179264151 20122 15 ( PL01-PL15 )
0.82 0.81 2003/19680
180277945 33540 12 ( PL46-PL57 )
0.89 0.89 1203/10221
178684089 36564 16 ( PL28-PL43 )
0.80 0.79 1464/12403
179351516 01429 16 ( PL37-PL52 )
0.79 0.79 1483/11961
181543007 53486 16 ( PL15-PL30 )
0.80 0.77 1693/15742
182245114 40953 16 ( PL36-PL51 )
187381090 40742 14 ( PL44-PL57 )
0.85 0.85 1599/15967
About Event 182245114
• There is PLATE ID Xray Mark in Scan Area.
• Efficiency~60%? → fail estimation of efficiency??
• For Data quality check and BG rejection, we analyze much more detail about effect for Alignment.
→ now processing
Near Future• About Volume Scan Area
and time
VTX Analysis Scan stream
Judgment ! ・ 1ry VTX ・ 2ry VTX ・ e-pair ・ Kink
daughter
1cm
Scan Level 1:VTX confirm
Scan Level 2: Decay Search Volume (for momentum measurement)
Scan Level 3: π0 Search Volume (~3X0)
Stop Plate
5mm
Recent Scanning time• 5mm x 5mm x 7plates /Event
0
50
100
150
200
250
1 2 3 4 5 6 7 8 9 10 11 12 13 14
plate
sec plate changer
scanning
Ev187249566 Ev191894066
Sheet change
Reduction of Scanning time • Decrease Scanning Area → (16cm2 /16plate → 6.2cm2/14plate)• Omit Surface recognition of start of Scanning → already process in SUTS-03. data
quality is good. → Scanning time is reduced 30%.• Both direction Scan → scanning time will be ½. → from now (Nakano-san)
Scanning time : 6.2/16 x 0.7 x 0.5 x (390sec x 16plate) /60 ~ 14minPlate change time : 50sec x 14plate /60 ~ 12minTotal : 14+12 = 26min/event
Before vs After
0skip 1skip 2skip
Reject前
465 2221 8057
Reject後
263 389 826
# of Chain # of Group efficiency
Reject前
112563 63530 0.80
Reject後
10624 8553 0.79
Linklet
Chain