VERWELL CAMEROON CABLES NGINEERING S.A.everwell-engineering.com/wp-content/uploads/2019/03/...E V E...
Transcript of VERWELL CAMEROON CABLES NGINEERING S.A.everwell-engineering.com/wp-content/uploads/2019/03/...E V E...
CameroonCertif ied
&VERWELL CAMEROON CABLES
NGINEERING S.A.E lec t r i c Ca b les Manu fac tu r e and D i s t r i bu t i on
E
Data catalog
EVERWELL CABLES
E V E R W E L L C A M E R O O N C A B L E S
INT
RO
DU
CT
ION
ounded in 2016, Everwell Cameroon Cables and Engineering Ltd. is the F
third subsidiary of Hebei Huatong Wire and Cable Co., Ltd. after that of Tanzania and South Africa.
Our production unit is located in the industrial area of ??Bonaberi-Ndobo. Due to our professionalism, long experience and our advanced research capability, we are manufacturer of modern electrical wires and cables.
For the first phase of implementation of our project in Cameroon, we have invested more than 10 million USD on an area of ??more than one hectare where we have installed large lines of production of electrical cables and advanced verification equipment for these cables. .
Our current products include:
- PR and PVC insulated power cables with voltages up to 3KV and 1KV respectively,- Insulated PVC cables with voltage up to 450 / 750V,- Aerial distribution and connection cables,- Control cables,- Bare conductors with aluminum strands (AAC)- Bare aluminum armored steel conductors (ACSR), etc.
We also produce flame retardant special cables, high fire resistance cables, high and low temperature resistance cables, low smoke zero halogen cables (LS0H) cables and environmental protection. These cables can also be produced according to the customer's requirements.The origin of our entrepreneurial outlook is based on accountability and quality.
2
3
TABL
E O
F CO
NTE
NT
PagePage
A N D E N G I N E E R I N G S . A .
1. Low-voltage household power cables, unsheathed
1.1 HO7V-U / HO5V-U
1.2 H07V-R / H05V-R
1.3 H07V-K / H05V-K
1.4 HO7V2-U / HO5V2-U
1.5 H07V2-R / H05V2-R
1.6 H07V2-K / H05V2-K
2. Low voltage sheathed flexible household power cables
2.1 H03VV-F / H05VV-F
2.2 H03VVH2-F / H05VVH2-F
2.3 H03V2V2-F / H05V2V2-F
2.4 H03V2V2H2-F / H05V2V2H2-F
3.Low voltage power cables with a nominal voltage of 600 / 1000V
3.1 U-1000 R2V / U-1000 AR2
3.2 U-1000 RVFV / U-1000 ARVFV
4. Low voltage power supply cables, IEC standard with rated voltage
600 / 1000V
4.1 - CU / XLPE / PVC 600 / 1000V Power cable with PVC sheathing, XLPE
insulated and copper core.
- CU / PVC / PVC 600 / 1000V Power cable with PVC sheathing,
PVC insulated and copper core.
- AL / XLPE / PVC 600 / 1000V Power cable with PVC sheathing,
XLPE insulated and aluminum core.
- AL / PVC / PVC 600 / 1000V PVC sheathed power cables, PVC insulated
and aluminum core.
4.2 - CU / XLPE / STA / PVC 600 / 1000V Power cable with PVC sheathing,
polyethylene insulated, steel strip shield and copper core.
- CU / PVC / STA / PVC 600 / 1000V Power cable with PVC sheathing,
shielded with steel strip, PVC insulation and copper core.
5
7
9
11
13
15
17
19
21
23
25
30
35
35
4
E V E R W E L L C A M E R O O N C A B L E S
- AL / XLPE / STA / PVC 600 / 1000V Power cable with PVC sheathing,
shielded steel strip, insulated polyethylene and aluminum core.
- AL / PVC / STA / PVC 600 / 1000V Power cable with PVC sheathing, shielded
with steel strip, polyethylene insulation and aluminum core.
4.3- CU / XLPE / SWA / PVC 600 / 1000V Power cable with PVC sheathing,
shielded with steel wires, polyethylene insulation and copper core.
- CU / PVC / SWA / PVC 600 / 1000V Power cable with PVC sheathing,
shielded with steel wires, PVC insulation and copper core
- AL / PVC / SWA / PVC 600 / 1000V PVC sheathed power cable, shielded with
steel wires, PVC insulation and aluminum core.
- AL / XLPE / SWA / PVC 600 / 1000V PVC sheathed power cable, shielded
with steel wires, PVC insulation and aluminum core.
5. Bare conductor
5.1 AAC bare twisted aluminum conductor wire
5.2 ACSR bare aluminum and steel reinforced wire
6. Bare twisted copper wire
7. Aerial distribution and connexion LV cables
8. Contacts
9. Huatong’s certificates
36
39
40
41
43
E V E R W E L L C A M E R O O N C A B L E S
45
46
TABL
E O
F CO
NTE
NT
A N D E N G I N E E R I N G S . A .
5
Low-voltage household power cables, unsheathed 1.1.1 HO7V-U / HO5V-U
Use and description
Usually installed inside appliances especially for lightning, internal wiring and as internal cabling for production facilities.Standards:EN 50525-2-31 NF C32-201-3
Conductor type: solid bare copper conductor IEC 60228 C1-1
Insulation:PVC-TI1 insulation
H07V-U Mainly used for power systems with nominal voltage up to 450 / 750V H05V-U Mainly used for power systems with nominal voltage up to 300/500V
Test voltage:( 2000V ) H05V-U
Test voltage:( 2500V ) H07V-U
Bending radius:15D
Operating temperature:-5°C-70°C
Short-circuit temperature :+160°C
Cable composition
Technical characteristics
Conductor
PVC insulation
Structure
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
PRO
DU
CT C
ATA
LOG
6
E V E R W E L L C A M E R O O N C A B L E S
2mm
0.5
0.75
1
1.5
2.5
4
6
10
Parameters
Nominal section
Conductor composition
Conductor type Categorie Insulation
materialInsulationthickness
Outerdiameter
1 x 0.8
1 x 0.98
1 x 1.13
1 x 1.36
1 x 1.76
1 x 2.24
1 x 2.76
1 x 3.53
0.6
0.6
0.6
0.7
0.8
0.8
0.8
0.9
Circulaire non compacte
Circulaire non compacte
Circulaire non compacte
Circulaire non compacte
Circulaire non compacte
2.0
2.2
2.3
2.8
3.4
3.8
4.4
5.5
Unit : mm
Class 1 70°C PVCCircular
non compact
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
7
Copper conductor
Insulation
Structure
A N D E N G I N E E R I N G S . A .
1.2 H07V-R / H05V-R
Use and description
Cable composition
Technical characteristics
Mainly used for indoors, electrical conduit, industrial facilities or for converter stations Can also be used for appliances such as switchboards and other common electrical
installations.
Standards:EN 50525-2-31 NF C32-201-3
Conductor type:Stranded copper conductor IEC 60228 C1-2
Insulation:PVC-TI1 insulation
H07V-R Mainly used for power systems with nominal voltage up to 300/500V
Test voltage : ( 2000V) H05V-R
Test voltage: ( 2500V ) H07V-R
Bending radius:15D
Operating temperature:-5℃-70℃
Short-circuit temperature :+160℃
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
PRO
DU
CT C
ATA
LOG
E V E R W E L L C A M E R O O N C A B L E S
2mm
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
7 x 0.30
7 x 0.37
7 x 0.43
7 x 0.51
7 x 0.66
7 x 0.84
7 x 1.02
7 x 1.35
7 x 1.70
7 x 2.14
7 x 2.52
19 x 1.83
19 x 2.14
19 x 2.52
37 x 2.03
37 x 2.26
37 x 2.52
37 x 2.92
61 x 2.52
61 x 2.92
0.6
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.1
2.3
2.5
2.9
3.6
4.1
4.7
5.8
6.8
8.4
9.4
11.2
12.8
14.8
16.2
18.1
20.2
22.8
25.4
29.0
Nominal section
Conductor composition
Conductor type Categorie Insulation
materialInsulationthickness
Outerdiameter
Parameters Unit : mm
Class 2 70°C PVCCircular
non compact
8Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
9
Copper conductor
PVC insulation
Structure
A N D E N G I N E E R I N G S . A .
1.3 H07V-K / H05V-K
Use and description
Cable composition
Technical characteristic
Mainly used for indoors, electrical conduit, industrial facilities or for converter stations Can also be used for frequently moved appliances Standards:EN 50525-2-31 NF C32-201-3
Conductor type:Stranded copper conductor IEC 60228 C1-5
Insulation:PVC-TI1 insulation
H07V-K Mainly used for power systems with nominal voltage up to 450/750V.
H05V-K Mainly used for power systems with nominal voltage up to 300/500V.
Test voltage:(2000V)H05V-K
Test voltage:(2500V)H07V-K
Bending radius:15D
Operating temperature:-5℃-70℃
Short-circuit temperature :+160℃
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
10
E V E R W E L L C A M E R O O N C A B L E S
2mm
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
16 x 0.20
25 x 0.20
30 x 0.20
28 x 0.25
46 x 0.25
52 x 0.30
78 x 0.30
73 x 0.40
116 x 0.40
181 x 0.40
256 x 0.40
365 x 0.40
333 x 0.50
437 x 0.50
563 x 0.50
702 x 0.50
851 x 0.50
1121 x 0.50
0.6
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.1
2.3
2.5
2.9
3.6
4.1
4.7
5.9
7.7
9.4
11.3
13.3
14.7
16.6
18.5
20.6
22.7
26.1
Nominal section
Conductor composition
Conductor type Categorie Insulation
materialInsulationthickness
Outerdiameter
Parameters Unit : mm
Class 5 70°C PVCCircular
non compact
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
11
Copper conductor
PVC insulation
Structure
A N D E N G I N E E R I N G S . A .
1.4 H07V2-U / H05V2-U
Use and description
Cable composition
Technical characteristic
Usually installed inside appliances especially for lightning, internal wiring and as
internal cabling for production facilities.
Standards:EN 50525-2-31 NF C32-201-3
Conductor type: Solid bare copper conductor IEC 60228 C1-1
Insulation : PVC-TI3 insulation
H07V2-U Mainly used for power systems with nominal voltage up to 450/750V
H05V2-U Mainly used for power systems with nominal voltage up to 300/500V
Test voltage:( 2000V ) H05V2-U
Test voltage:( 2500V ) H07V2-U
Bending radius:15D
Operating temperature:-5℃-90℃
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
E V E R W E L L C A M E R O O N C A B L E S
12
2mm
0.5
0.75
1
1.5
2.5
4
6
10
1 x 0.8
1 x 0.98
1 x 1.13
1 x 1.36
1 x 1.76
1 x 2.24
1 x 2.76
1 x 3.53
0.6
0.6
0.6
0.7
0.8
0.8
0.8
1.0
Circulaire non compacte
Circulaire non compacte
Circulaire non compacte
Circulaire non compacte
Circulaire non compacte
2.0
2.2
2.3
2.8
3.4
3.8
4.4
5.5
Class 1 70°C PVCCirculaire
non compacte
Nominal section
Conductor composition
Conductor type Categorie Insulation
materialInsulationthickness
Outerdiameter
Parameters Unit : mm
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
13
1.5 H07V2-R / H05V2-R
Use and description
Cable composition
Technical characteristic
Mainly used for indoors, electrical conduit, industrial facilities or for converter stations. Can also be used for appliances such as switchboards and other common electrical
installations.
Standards:EN 50525-2-31 NF C32-201-3
Conductor type:Stranded copper conductor IEC 60228 C1-2
Insulation : PVC-TI3 insulation
H07V2-R Mainly used for power systems with nominal voltage up to 450/750V
H05V2-R Mainly used for power systems with nominal voltage up to 300/500V
Test voltage:( 2000V ) H05V2-R
Test voltage:( 2500V ) H07V2-R
Bending radius:15D
Operating temperature:-5℃-90℃
Short-circuit temperature :+160℃
Copper conductor
PVC insulation
Structure
A N D E N G I N E E R I N G S . A .
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
14
E V E R W E L L C A M E R O O N C A B L E S
2mm
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
7 x 0.30
7 x 0.37
7 x 0.43
7 x 0.51
7 x 0.66
7 x 0.84
7 x 1.02
7 x 1.35
7 x 1.70
7 x 2.14
7 x 2.52
19 x 1.83
19 x 2.14
19 x 2.52
37 x 2.03
37 x 2.26
37 x 2.52
37 x 2.92
61 x 2.52
61 x 2.92
0.6
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.1
2.3
2.5
2.9
3.6
4.1
4.7
5.8
6.8
8.4
9.4
11.2
12.8
14.8
16.2
18.1
20.2
22.8
25.4
29.0
Nominal section
Conductor composition
Conductor type Categorie Insulation
materialInsulationthickness
Outerdiameter
Parameters Unit : mm
Class 2 70°C PVCCircular
and compact
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
15
1.6 H07V2-K / H05V2-K
Copper conductor
PVC insulation
Structure
A N D E N G I N E E R I N G S . A .
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
E V E R W E L L C A M E R O O N C A B L E S
16
2mm
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
16 x 0.20
25 x 0.20
30 x 0.20
28 x 0.25
46 x 0.25
52 x 0.30
78 x 0.30
73 x 0.40
116 x 0.40
181 x 0.40
256 x 0.40
365 x 0.40
333 x 0.50
437 x 0.50
563 x 0.50
702 x 0.50
851 x 0.50
1121 x 0.50
0.6
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.1
2.3
2.5
2.9
3.6
4.1
4.7
5.9
7.7
9.4
11.3
13.3
14.7
16.6
18.5
20.6
22.7
26.1
Nominal section
Conductor composition
Conductor type Categorie Insulation
materialInsulationthickness
Outerdiameter
Parameters Unit : mm
Class 5 70°C PVCCircular
non compact
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
17
Copper conductor
PVC outer sheath
Structure
A N D E N G I N E E R I N G S . A .
2.1 H03VV-F / H05VV-F
Low Voltage Sheathed Flexible Household Power
Cables2.
PVC insulation
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
18
E V E R W E L L C A M E R O O N C A B L E S
2mm
2 x 0.50
2 x 0.75
3 x 0.50
3 x 0.75
4 x 0.50
4 x 0.75
2 x 0.75
2 x 1
2 x 1.5
2 x 2.5
2 x 4.0
3 x 0.75
3 x 1
3 x 1.5
3 x 2.5
3 x 4
4 x 0.75
4 x 1
4 x 1.5
4 x 2.5
4 x 4
5 x 0.75
5 x 1
5 x 1.5
5 x 2.5
5 x 4
16 x 0.20
24 x 0.20
16 x 0.20
24 x 0.20
16 x 0.20
24 x 0.20
24 x 0.20
30 x 0.20
28 x 0.25
46 x 0.25
52 x 0.30
24 x 0.20
30 x 0.20
28 x 0.25
46 x 0.25
52 x 0.30
24 x 0.20
30 x 0.20
28 x 0.25
46 x 0.25
52 x 0.30
24 x 0.20
30 x 0.25
28 x 0.25
46 x 0.25
52 x 0.30
0.92
1.13
0.92
1.13
0.92
1.13
1.13
1.26
1.53
1.96
2.50
1.13
1.26
1.53
1.96
2.50
1.13
1.26
1.53
1.96
2.50
1.13
1.26
1.53
1.96
2.50
Class 5 70°C PVC
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.8
0.8
0.6
0.6
0.7
0.8
0.8
0.6
0.6
0.7
0.8
0.8
0.6
0.6
0.7
0.8
0.8
5.0
5.5
5.3
5.8
5.8
6.4
6.7
7.0
7.9
9.6
10.9
7.1
7.4
8.6
10.4
11.7
7.7
8.2
9.6
11.3
12.8
8.6
8.9
10.6
12.5
14.3
H03VV-F300 / 300V
H05VV-F300 / 500V
Product model
Conductorcomposition
Conductor type
Insulationmaterial
Dimension and shape of theouter sheath
Conductor diameter
Insulationnominal
thickness
N° of Conductor and cross section
of Conductor
Parameters Unit : mm
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
19
PVC insulation
Copper conductor
PVC sheath
Structure
A N D E N G I N E E R I N G S . A .
2.2 H03VVH2-F / H05VVH2-F
Use and description
Cable composition
Technical characteristic
Mainly used for small household appliances and light domestic appliances like kitchen
appliances, lamps, street lamp, vacuum cleaner and other connecting lamp. Cables
with a cross-section below 0.75mm2 are not suitable for outdoor use.
Standards:EN 50525-2-11 NF C32-201-5
Conductor type:Stranded copper conductor IEC 60228 C1-5
Insulation : PVC-TI3 insulation
Sheath:Sheath type PVCTM2
H03VVH2-F Mainly used for power systems with nominal voltage up to 300/300V
H05VVH2-F Mainly used for power systems with nominal voltage up to 300/500V
Test voltage : ( 2000V ) H03VVH2-K
Test voltage:( 2000V ) H05VVH2-K
Bending radius:15D
Operating temperature:-5°C-70℃
Short-circuit temperature :+160℃
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
20
E V E R W E L L I N P I C T U R E S
E V E R W E L L C A M E R O O N C A B L E S
2mm
2 x 0.50
2 x 0.75
2 x 0.75
2 x 1.0
16 x 0.20
24 x 0.20
24 x 0.20
30 x 0.20
0.92
1.13
1.13
1.26
Class 5 70°C PVC
0.5
0.5
0.6
0.6
3.1 X 5.0
3.3 X 5.5
3.9 X 6.3
4.1 X 6.5
H05VVH2-F
300 / 500V
H03VVH2-F
300 / 300V
Product model
Conductorcomposition
Conductor type
Insulationmaterial
Outer sheath dimension and shape
Conductor diameter
Insulationnominal
thickness
N° of Conductor and cross section
of Conductor
Parameters Unit : mm
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
A N D E N G I N E E R I N G S . A .
21
2.3 H03V2V2-F / H05V2V2-F
Use and description
Cable composition
Technical characteristic
Mainly used for small household appliances and light domestic appliances like kitchen
appliances, lamps, street lamp, vacuum cleaner and other connecting lamp. Cables
with a cross-section below 0.75mm² are not suitable for outdoor use.Standards : EN 50525-2-11 NF C32-201-5
Conductor type:Stranded copper conductor IEC 60228 C1-5
Insulation : PVC-TI3 insulation
Sheath:Sheath type PVCTM2
H03V2V2-F Mainly used for power systems with nominal voltage up to 300/300V
H05V2V2-F Mainly used for power systems with nominal voltage up to 300/500V
Test voltage:( 2000V ) H03V2V2-F
Test voltage:( 2000V ) H05V2V2-F
Bending radius:15D
Operating temperature:-5℃-90℃
Short-circuit temperature :+160℃
PVC insulation
PVC insulation
PVC insulation sheath
Copper condutor
Structure
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
E V E R W E L L C A M E R O O N C A B L E S
22
2mm
2 x 0.50
2 x 0.75
3 x 0.50
3 x 0.75
4 x 0.50
4 x 0.75
2 x 0.75
2 x 1
2 x 1.5
2 x 2.5
2 x 4.0
3 x 0.75
3 x 1
3 x 1.5
3 x 2.5
3 x 4
4 x 0.75
4 x 1
4 x 1.5
4 x 2.5
4 x 4
5 x 0.75
5 x 1
5 x 1.5
5 x 2.5
5 x 4
16 x 0.20
24 x 0.20
16 x 0.20
24 x 0.20
16 x 0.20
24 x 0.20
24 x 0.20
30 x 0.20
28 x 0.25
46 x 0.25
52 x 0.30
24 x 0.20
30 x 0.20
28 x 0.25
46 x 0.25
52 x 0.30
24 x 0.20
30 x 0.20
28 x 0.25
46 x 0.25
52 x 0.30
24 x 0.20
30 x 0.25
28 x 0.25
46 x 0.25
52 x 0.30
0.92
1.13
0.92
1.13
0.92
1.13
1.13
1.26
1.53
1.96
2.50
1.13
1.26
1.53
1.96
2.50
1.13
1.26
1.53
1.96
2.50
1.13
1.26
1.53
1.96
2.50
Class 5 70°C PVC
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.8
0.8
0.6
0.6
0.7
0.8
0.8
0.6
0.6
0.7
0.8
0.8
0.6
0.6
0.7
0.8
0.8
5.0
5.5
5.3
5.8
5.8
6.4
6.7
7.0
7.9
9.6
10.9
7.1
7.4
8.6
10.4
11.7
7.7
8.2
9.6
11.3
12.8
8.6
8.9
10.6
12.5
14.3
H03VV-F300 / 300V
H05VV-F300 / 500V
Product model
Conductorcomposition
Conductor type
Insulationmaterial
Outer sheath dimension and shape
Conductor diameter
Insulationnominal
thickness
N° of Conductor and cross section
of Conductor
Parameters Unit : mm
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
23
PVC insulation
Copper conductor
PVC sheath
Structure
A N D E N G I N E E R I N G S . A .
2.4 H03V2V2H2-F / H05V2V2H2-F
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
E V E R W E L L C A M E R O O N C A B L E S
24
2mm
2 x 0.50
2 x 0.75
2 x 0.75
2 x 1.0
2 x 1.50
16 x 0.20
24 x 0.20
24 x 0.20
30 x 0.20
28 x 0.25
0.92
1.13
1.13
1.26
1.53
0.5
0.5
0.6
0.6
0.7
3.1 X 5.0
3.3 X 5.5
3.9 X 6.3
4.1 X 6.5
4.5 x 7.5
H05VVH2-F
300 / 500V
H03VVH2-F
300 / 300V
Class 5 70°C PVC
Product model
Conductorcomposition
Conductor type
Insulationmaterial
Outer sheath dimension and shape
Conductor diameter
Insulationnominal
thickness
N° of Conductor and cross section
of Conductor
Parameters Unit : mm
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
A N D E N G I N E E R I N G S . A .
25
Filling
Copper conductorXLPE insulation
PVC outer sheath
Structure
Filling
Aluminium conductorXLPE insulation
PVC outer sheath
3.1 U-1000 R2V / U-1000 AR2V
Low voltage power cables with a nominal voltage
of 600 / 1000V3.
Use and description
Cable composition
Technical characteristic
Suitable for low tension industrial connection such as urban electrical networks, buildings etc. Can also be placed in the open without additional protection, on walls, underground cable duct or electrical conduit.
Standards:NF C32-321 EN60332-1
Conductor type: U-1000 R2V Wired bare copper conductor IEC 60228 C1-2U-1000 AR2V Twisted Aluminum Conductor IEC 60228 C1-2Insulation: XLPE InsulationFilling: Filling in non-fibrous and non-absorbant materialsSheath: Black polyvinyl chloride sheath
Rated voltages: 600 / 1000VTest voltage: 1200VRadius of curvature: 6DOperating temperature: -10 ° C-90 ° CShort circuit temperature: + 250 ° C
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
26
E V E R W E L L C A M E R O O N C A B L E S
2mm
N° of conductorand cross section
of Conducteur
Conductordiameter
xSector height
Insulatorthickness
Earth conductordiameter
insulation
Underground cable
thickness
Corediameter
Cablediameter
Ribbon thickness
Thickness of the outer
sheath
Outercable
diameter
1x1.5
1x2.5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1.5
2x2.5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
1.5
2.0
2.5
3.1
3.8
4.8
6.0
7.0
8.3
10.0
11.6
13.0
14.6
16.2
18.4
20.6
1.5
2.0
2.5
3.1
3.8
4.8
6.0
4.8
5.7
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
2.9
3.4
3.9
4.5
5.2
6.2
7.8
8.8
10.3
12.2
13.8
15.4
17.4
19.4
21.8
24.2
2.9
3.4
3.9
4.5
5.2
6.2
7.8
6.6
7.7
2.9
3.4
3.9
4.5
5.2
6.2
7.8
8.8
10.3
12.2
13.8
15.4
17.4
19.4
21.8
24.2
5.9
6.8
7.8
8.9
10.4
12.4
15.6
14.5
17.7
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
5.7
6.2
6.7
7.3
8.0
9.0
10.6
11.6
13.1
15.0
16.8
18.4
20.6
22.6
25.2
27.8
9.9
10.8
11.9
13.0
14.5
16.5
19.7
18.6
21.1
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
Parameters Unit : mm
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
27
Continued ...
A N D E N G I N E E R I N G S . A .
2x70
2x95
2x120
2x150
2x185
2x240
2x300
3x1.5
3x2.5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
4x1.5
4x2.5
6.7
7.9
8.8
10.0
11.1
12.8
14.1
1.5
2.0
2.5
3.1
3.8
4.8
6.0
5.9
7.0
8.5
9.9
11.1
12.5
13.9
15.6
17.5
1.5
2.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
1.7
1.7
1.7
1.7
1.7
1.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
1.7
1.7
8.9
10.1
11.2
12.8
14.3
16.2
17.7
2.9
3.4
3.9
4.5
5.2
6.2
7.8
7.7
9.0
10.7
12.1
13.5
15.3
17.1
19.0
21.1
2.9
3.4
19.5
22.3
24.6
27.7
30.9
34.7
38.4
6.3
7.3
8.4
9.6
11.2
13.4
16.8
18.0
21.2
24.4
27.8
3.5
34.3
38.4
43.0
47.9
7.1
8.2
1.8
1.9
2
2.2
2.3
2.5
2.6
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2
2.1
2.3
2.4
2.6
2.7
1.8
1.8
23.6
26.7
29.2
32.7
36.1
40.3
44.2
10.4
11.4
12.5
13.7
15.3
17.4
20.9
22.1
25.3
28.7
32.4
35.3
39.5
43.8
48.8
53.9
11.2
12.3
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
2mm
N° of conductorand cross section
of Conducteur
Conductordiameter
xSector height
Insulatorthickness
Corediameter
Cablediameter
Ribbon thickness
Thickness of the outer
sheath
Outercable
diameter
Parameters Unit : mm
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
Earth conductordiameter
insulation
Underground cable
thickness
PRO
DU
CT C
ATA
LOG
28
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
5x1.5
5x2.5
5x4
5x6
5x10
5x16
5x25
5x35
5x50
5x70
5x95
2.5
3.1
3.8
4.8
6.0
6.7
8.0
9.5
11.2
12.6
14.1
15.6
17.8
19.8
1.5
2.0
2.5
3.1
3.8
4.8
6.0
7.0
8.8
10.3
12.1
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
3.9
4.5
5.2
6.2
7.8
8.5
10.0
11.7
13.4
15.0
16.9
18.8
21.2
23.4
2.9
3.4
3.9
4.5
5.2
6.2
7.8
8.8
10.8
12.5
14.3
9.5
10.8
12.6
15.0
18.9
20.6
24.4
27.7
31.9
35.3
39.5
44.1
49.8
55.0
7.9
9.1
10.6
12.0
14.0
16.7
21.1
23.8
27.3
31.1
35.9
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2
2.1
2.3
2.4
2.6
2.8
3
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.1
2.2
13.6
14.9
16.7
19.1
23.0
24.7
28.4
32.2
36.7
40.5
44.9
49.9
56.0
61.6
12.0
13.2
14.7
16.1
18.1
20.8
25.1
27.8
31.6
35.8
40.9
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
Continued ...
2mm
N° of conductorand cross section
of Conducteur
Conductordiameter
xSector height
Insulatorthickness
Corediameter
Cablediameter
Ribbon thickness
Thickness of the outer
sheath
Outercable
diameter
Parameters Unit : mm
E V E R W E L L C A M E R O O N C A B L E S
Earth conductordiameter
insulation
Underground cable
thickness
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
5x120
5x150
5x185
5x240
5x300
13.7
15.3
17.1
19.3
21.7
2.0
2.5
3x1
3x8
4x8
6.0
6.4
7.6
9.1
10.6
12.1
13.6
14.9
17.0
19.1
1.2
1.4
1.6
1.7
1.8
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
16.1
18.1
20.3
22.7
25.3
3.4
3.9
4.5
5.2
6.2
7.8
8.2
9.6
11.3
12.8
14.5
16.4
18.1
20.4
22.7
39.7
44.3
49.6
55.7
61.7
7.9
9.2
10.5
12.1
14.4
17.9
19.5
23.1
26.3
30.2
33.4
37.6
41.6
47.0
52.3
2.4
2.6
2.8
3
3.2
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.1
2.2
2.3
2.5
2.7
2.8
45.1
50.1
55.8
62.3
68.7
12.0
13.2
14.5
16.2
18.5
22.0
23.6
27.2
30.5
35.0
38.4
42.8
47.2
53.0
58.5
3x2.5 + 1x1.5
3x4 + 1x1.5
3x6 + 1x4
3x10 + 1x6
3x16 + 1x10
3x25 + 1x16
3x35 + 1x16
3x50 + 1x25
3x70 + 1x35
3x95 + 1x50
3x120 + 1x70
3x150 + 1x70
3x185 + 1x95
3x240 + 1x120
3x300 + 1x150
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.4
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
29
Continued ...
1.5
2.0
2.5
3.1
3.8
4.8
4.8
6.0
7.0
8.3
10.0
10.0
11.6
13.0
14.6
2mm
N° of conductorand cross section
of Conducteur
Conductordiameter
xSector height
Insulatorthickness
Corediameter
Cablediameter
Ribbon thickness
Thickness of the outer
sheath
Outercable
diameter
Parameters Unit : mm
A N D E N G I N E E R I N G S . A .
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
Earth conductordiameter
insulation
Underground cable
thickness
PRO
DU
CT C
ATA
LOG
30
PVC outer sheath
Copper conductorPVC inner sheath
XLPE insulationFillingSteel trip shield
Structure
PVC outer sheath
Copper conductorPVC inner sheath
XLPE insulationFillingSteel trip shield
E V E R W E L L C A M E R O O N C A B L E S
3.2 U-1000 RVFV / U-1000 ARVFV
Use and description
Cable composition
Technical characteristics
Suitable for low tension industrial connection such as urban electrical networks, buildings etc. Can also be placed in the open without additional protection, on walls, underground cable duct or electrical conduit by adding a shielding layer over the common power cables. Can be immediately buried without protection.
Standards:NF C32-322 EN60332-1
Conductor type: U-1000 RVFV Wired bare copper conductor IEC 60228 C1-2U-1000 ARVFV Torinable aluminum conductor IEC 60228 C1-2Insulation: XLPE InsulationFilling: Filling in non-fibrous and non-absorbent materialsDouble shielding in galvanized steel stripSheath: Black polyvinyl chloride sheath
Nominal voltage:600/1000V
Test voltage:1200V
Bending radius:6D
Operating temperature:-10°C-90°C
Short-circuit temperature:+250°C
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
A N D E N G I N E E R I N G S . A .
31
1x1.5
1x2.5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1.5
2x2.5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
1.5
2.0
2.5
3.1
3.8
4.8
6.0
7.0
8.3
10.0
11.6
13.0
14.6
16.2
18.4
20.6
1.5
2.0
2.5
3.1
3.8
4.8
6.0
4.8
5.7
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
2.9
3.4
3.9
4.5
5.2
6.2
7.8
8.8
10.3
12.2
13.8
15.4
17.4
19.4
21.8
24.2
2.9
3.4
3.9
4.5
5.2
6.2
7.8
6.6
7.7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
5.9
6.8
7.8
8.9
10.4
12.4
15.6
14.5
17.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4.9
5.4
5.9
6.5
7.2
8.2
9.8
10.8
12.3
14.2
15.8
17.4
19.4
21.4
23.8
26.2
8.3
9.2
10.3
11.4
12.9
14.9
18.1
17.0
19.5
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
6.5
7.0
7.5
8.1
8.8
9.8
11.4
12.4
13.9
15.8
17.4
19.0
21.0
23.0
25.4
28.0
9.9
10.8
11.9
13.0
14.5
16.5
19.7
18.6
21.1
2mm
Conductordiameter
xSectorheight
Insulationthickness
Earthconductordiameter
Corediameter
Cablediameter
Ribbonthickness
Outersheath
thickness
OuterDiameter
Inner insulationthickness
Steeltrip
thickness
Outer cable
diameter
N° of conductor and crosssection of
Conductor
Parameters Unit : mm
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
Undergroundcable
insulation thickness
PRO
DU
CT C
ATA
LOG
32
2x70
2x95
2x120
2x150
2x185
2x240
2x300
3x1.5
3x2.5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
4x1.5
4x2.5
6.7
7.9
8.8
10.0
11.1
12.8
14.1
1.5
2.0
2.5
3.1
3.8
4.8
6.0
5.9
7.0
8.5
9.9
11.1
12.5
13.9
15.6
17.5
1.5
2.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
1.7
1.7
1.7
1.7
1.7
1.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
1.7
1.7
8.9
10.1
11.2
12.8
14.3
16.2
17.7
2.9
3.4
3.9
4.5
5.2
6.2
7.8
7.7
9.0
10.7
12.1
13.5
15.3
17.1
19.0
21.1
2.9
3.4
19.5
22.3
24.6
27.7
30.9
34.7
38.4
6.3
7.3
8.4
9.6
11.2
13.4
16.8
18.0
21.2
24.4
27.8
30.5
34.3
38.4
43.0
47.9
7.1
8.2
1
1.2
1.2
1.2
1.4
1.4
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1
1
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1
1
0.16
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.16
0.16
0.16
0.2
0.2
0.2
0.2
0.2
0.2
0.6
0.6
22.0
25.3
27.6
30.7
34.3
38.1
42.2
8.8
9.8
10.9
12.1
13.7
15.8
19.3
20.5
23.7
27.3
30.8
33.5
37.7
41.8
46.8
51.7
9.6
10.7
0.2
0.2
0.5
0.5
0.5
0.5
0.5
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.5
0.5
0.5
0.5
0.5
0.5
0.2
0.2
1.9
2.0
2.2
2.3
2.4
2.6
2.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.2
2.3
2.4
2.6
2.7
2.9
1.8
1.8
23.8
26.9
29.6
23.9
36.3
40.5
44.6
10.4
11.4
12.5
13.7
15.3
17.4
20.9
22.1
25.3
28.9
32.8
35.7
39.7
44.2
49.0
54.3
11.2
12.3
Continued ...
2mm
Conductordiameter
xSectorheight
Insulationthickness
Earthconductordiameter
Corediameter
Cablediameter
Ribbonthickness
Outersheath
thickness
OuterDiameter
Steeltrip
thickness
Outer cable
diameter
N° of conductor and crosssection of
Conductor
Parameters Unit : mm
E V E R W E L L C A M E R O O N C A B L E S
Undergroundcable
insulation thickness
Inner insulationthickness
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
33
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
5x1.5
5x2.5
5x4
5x6
5x10
5x16
5x25
5x35
5x50
5x70
5x95
2.5
3.1
3.8
4.8
6.0
6.7
8.0
9.5
11.2
12.6
14.1
15.6
17.8
19.8
1.5
2.0
2.5
3.1
3.8
4.8
6.0
7.0
8.8
10.3
12.1
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
3.9
4.5
5.2
6.2
7.8
8.5
10.0
11.7
13.4
15.0
16.9
18.8
21.2
23.4
2.9
3.4
3.9
4.5
5.2
6.2
7.8
8.8
10.8
12.5
14.3
9.5
10.8
12.6
15.0
18.9
20.6
24.4
27.7
31.9
35.3
39.5
44.1
49.8
55.0
7.9
9.1
10.6
12.0
14.0
16.7
21.1
23.8
27.3
31.1
35.9
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.2
0.2
0.2
0.2
0.2
0.2
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.2
1
1
1
1
1
1
1
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1
1
1
1
1
1
1
1
1.2
1.2
1.4
12.0
13.3
15.1
17.5
21.4
23.1
26.8
30.6
34.9
38.7
42.9
47.5
53.6
58.8
10.4
11.6
13.1
14.5
16.5
19.2
23.5
26.2
30.2
34.0
39.3
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.5
0.5
0.5
0.5
0.5
0.5
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.5
0.5
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.1
2.3
2.4
2.6
2.7
2.9
3.1
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.4
13.6
14.9
16.7
19.1
23.0
24.7
28.6
32.4
37.1
40.7
45.3
50.1
56.2
61.8
12.0
13.2
14.7
16.1
18.1
20.8
25.1
28.0
31.8
36.0
41.3
Continued ...
2mm
Conductordiameter
xSectorheight
Insulationthickness
Earthconductordiameter
Corediameter
Cablediameter
Ribbonthickness
Outersheath
thickness
OuterDiameter
Steeltrip
thickness
Outer cable
diameter
N° of conductor and crosssection of
Conductor
Parameters Unit : mm
A N D E N G I N E E R I N G S . A .
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
Undergroundcable
insulation thickness
Inner insulationthickness
PRO
DU
CT C
ATA
LOG
34
5x120
5x150
5x185
5x240
5x300
3x2.5 + 1x1.5
3x4 + 1x1.5
3x6 + 1x4
3x10 + 1x6
3x16 + 1x10
3x25 + 1x16
3x35 + 1x16
3x50 + 1x25
3x70 + 1x35
3x95 + 1x50
3x120 + 1x70
3x150 + 1x70
3x185 + 1x95
3x240 + 1x120
3x300 + 1x150
13.7
15.3
17.1
19.3
21.7
2.0
2.5
3x1
3x8
4x8
6.0
6.4
7.6
9.1
10.6
12.1
13.6
14.9
17.0
19.1
1.2
1.4
1.6
1.7
1.8
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
1.58
1.98
2.52
3.06
3.80
4.80
4.80
6.0
7.0
8.3
10.0
10.0
11.6
13.0
14.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.4
16.1
18.1
20.3
22.7
25.3
3.4
3.9
4.5
5.2
6.2
7.8
8.2
9.6
11.3
12.8
14.5
16.4
18.1
20.4
22.7
39.7
44.3
49.6
55.7
61.7
7.9
9.2
10.5
12.1
14.4
17.9
19.5
23.1
26.3
30.2
33.4
37.6
41.6
47.0
52.3
0.2
0.2
0.2
0.2
0.2
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.2
0.2
0.2
0.2
0.2
0.2
1.4
1.4
1.6
1.6
1.8
1
1
1
1
1
1
1
1
1.2
1.2
1.2
1.4
1.4
1.6
1.6
43.1
47.7
53.4
59.5
65.9
10.4
11.6
12.9
14.6
16.9
20.4
22.0
25.6
29.1
33.2
36.4
41.0
45.0
50.8
56.1
0.5
0.5
0.5
0.5
0.5
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.5
0.5
0.5
0.5
0.5
0.5
2.6
2.7
2.9
3.1
3.4
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.5
2.6
2.8
3.0
45.5
50.3
56.0
62.5
69.1
12.0
13.2
14.5
16.2
18.5
22.0
23.6
27.4
30.7
35.2
38.6
43.2
47.4
53.2
58.9
Continued ...
2mm
Conductordiameter
xSectorheight
Insulationthickness
Earthconductordiameter
Undergroundcable
insulation thickness
Corediameter
Cablediameter
Ribbonthickness
Outersheath
thickness
OuterDiameter
Steeltrip
thickness
Outer cable
diameter
N° of conductor and crosssection of
Conductor
Parameters Unit : mm
E V E R W E L L C A M E R O O N C A B L E S
Inner insulationthickness
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
35
A N D E N G I N E E R I N G S . A .
4.Composition:
4.1. - CU/XLPE/PVC 600/1000V - CU/PVC/PVC 600/1000V
- AL/XLPE/PVC 600/1000V - AL/PVC/PVC 600/1000V
Copper conductor
Insulation
Wrap
Outer sheath
Copper conductorInsulation
Wrap
Outer sheath
4.2. - CU/XLPE/STA/PVC 600/1000V - CU/PVC/STA/PVC 600/1000V
- AL/XLPE/STA/PVC 600/1000V - AL/PVC/STA/PVC 600/1000V
Copper conductor
Insulation
Filling
Outer sheath
WrapInner linerSteel trip shield
Filling
Low voltage power cables, IEC standards with a
nominal voltage of 600 / 1000V
Copper conductorInsulation
Outer sheath
WrapInner linerSteel trip shield
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
E V E R W E L L C A M E R O O N C A B L E S
36
Use and description
Caractéristique d'utilisation
Suitable for industrial connections such as urban electrical network, buildings etc. Mainly used for AC transmission and distribution lines with nominal voltages of 0.6 / 1KV and below.
Standards:IEC 60502-1
1. Cables with a nominal voltage of 0.6/1KV
2. The PVC insulation allows the power cables to operate 70°C; the highest temperature in case of short circuit is 160 °C (it is not allowed to exceed 5S). XLPE insulation allows the power cables operation at 90 °C; the highest temperature in case of short circuit is 250 °C (it is not allowed to exceed 5S).
4.6. - CU/XLPE/SWA/PVC 600/1000V - CU/PVC/SWA/PVC 600/1000V
- AL/XLPE/SWA/PVC 600/1000V - AL/PVC/SWA/PVC 600/1000V
Copper conductorInsulationFilling
Outer sheath
WrapInner linerSteel strip shield
Copper conductorInsulation
Outer sheath
WrapInner linerSteel strip shield
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
37
Model choice
1*1.5 2*1.5 3*1.5 4*1.5 5*1.5 3*1.5+1*1.0 3*1.5+2*1.0 4*2.5+1*1.0
1*2.5 2*2.5 3*2.5 4*2.5 5*2.5 3*2.5+1*1.5 3*2.5+2*1.5 4*2.5+1*1.5
1*4 2*4 3*4 4*4 5*4 3*4+1*2.5 3*4+2*2.5 4*4+1*2.5
1*6 2*6 3*6 4*6 5*6 3*6+1*4 3*6+2*4 4*6+1*4
1*10 2*10 3*10 4*10 5*10 3*10+1*6 3*10+2*6 4*10+1*6
1*16 2*16 3*16 4*16 5*16 3*16+1*10 3*16+2*10 4*16+1*10
1*25 2*25 3*25 4*25 5*25 3*25+1*16 3*25+2*16 4*25+1*16
1*35 2*35 3*35 4*45 5*35 3*35+1*16 3*35+2*16 4*35+1*16
Nomber of conductor X section (mm²)nominal
Not categorisedConductor category(1- R conductors)N
A N D E N G I N E E R I N G S . A .
3. The required temperature for the power cables installation must not fall below 0 ? .
The allowed bend radius for unipolar unshielded cables is 20D; for unipolar cables with shielding, the allowed bend radius is 15D. Unshielded 3-pole cables have an allowed bend radius of 15D, while the allowed bending radius for 3-pole shielded cables is 12D.
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
E V E R W E L L C A M E R O O N C A B L E S
38
1*50 2*50 3*50 4*50 5*50 3*50+1*25 3*50+2*25 4*50+1*25
1*70 2*70 3*70 4*70 5*70 3*70+1*35 3*70+2*35 4*70+1*35
1*95 2*95 3*95 4*95 5*95 3*95+1*50 3*95+2*50 4*95+1*50
1*120 2*120 3*120 4*120 5*120 3*120+1*70 3*120+2*70 4*120+1*70
1*150 2*150 3*150 4*150 5*150 3*150+1*70 3*150+2*70 4*150+1*70
1*185 2*185 3*185 4*185 5*185 3*185+1*95 3*185+2*95 4*185+1*95
1*240 2*240 3*240 4*240 5*240 3*240+1*120 3*240+2*120 4*240+1*120
1*300 2*300 3*300 4*300 5*300 3*300+1*150 3*300+2*150 4*300+1*150
1*400 2*400 3*400 4*400 5*400 3*400+1*185 3*400+2*185 4*400+1*185
Nomber of conductor X section (mm²)nominal
Not categorisedConductor category(1- R conductors)N
Continued ...
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
39
Name
Structure
Stranding
20
Number/ diameter
OuterDiametre
kN Ω/km
22 MIDGE 7 / 2.06 1+6 6.18 3.99 1.227
50 ANT 7 / 3.1 1+6 9.30 8.28 0.5419
60 FLY 7 / 3.4 1+6 10.20 9.90 0.4505
100 WASP 7 / 4.39 1+6 13.17 16.00 0.2702
150 HORNET 19 / 3.25 1+6+12 16.3 25.70 0.1825
200 CHAFER 19 / 3.78 1+6+12 18.9 32.40 0.1349
250 COCKROACH 19 / 4.22 1+6+12 21.1 40.40 0.1083
300 BUTTERFLY 19 / 4.65 1+6+12 23.3 48.75 0.08916
400 CENTIPEDE 37 / 3.78 1+6+12+18 26.5 63.10 0.06944
5.1 AAC bare twisted aluminum conductor wire
Presentation
Mainly used for overhead transmission lines, long distance transmissions, transmission networks and outdoor long-range energy distribution.
CaracteristicThe product is difficult to damage once installed, which reduces electrical losses and reduces interference on transmission lines and radio waves.
Standards:BS 215-1
Aluminium wire
5.Bare conductors
Cross section
Productcode
Storage mode
Commonlayout
Minimum breaking
force
Direct current
resistance
A N D E N G I N E E R I N G S . A .
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
20
E V E R W E L L C A M E R O O N C A B L E S
40
Steel core structure
Ω/km
25 GOPHER 1 / 2.36 2.36 6 / 2.36 7.1 1.0930
30 WEASEL 1 / 2.59 2.59 6 / 2.59 7.8 0.9077
40 FERRET 1 / 3.00 3.00 6 / 3.00 9.0 0.6766
50 RABBIT 1 / 3.35 3.35 6 / 3.35 10.1 0.5426
70 HORSE 7 / 2.79 8.37 12 / 2.79 14.0 0.3936
100 DOG 7 / 1.57 4.71 6 / 4.72 14.2 0.2733
150 WOLF 7 / 2.59 7.77 30 / 2.59 18.1 0.1828
150 DINGO 1 / 3.35 3.35 18 / 3.35 16.8 0.1815
175 LYNX 7 / 2.79 8.37 30 / 2.79 19.5 0.1576
175 CARACAL 1 / 3.61 3.61 18 / 3.61 18.1 0.1563
200 PANTHER 7 / 3.00 9.00 30 / 3.00 21.0 0.1363
200 JAGUAR 1 / 3.86 3.86 18 / 3.86 19.3 0.1367
400 ZEBRA 7 / 3.18 9.54 54 / 3.18 28.6 0.0674
5.2 Bare aluminum and reinforced wireACSR steel
Presentation
Mainly used for overhead transmission lines, long distance transmissions, transmission networks and outdoor long-range energy distribution.
CaracteristicsThe product is difficult to damage once installed, which reduces electrical losses and reduces interference on transmission lines and radio waves.
Standards:BS 215-2
Steel wire
Aluminium wire
Cross section
Productcode
Cross section
Number/Diametermm
Outer
DiametreNumber/Diameter
mm
Aluminium core structure
Outer
Diametre
Direct current resistance
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
41
Name Structure Standing
20
kN Ω/km
10 7 / 1.35 4.1 3.75 1.788
14 7 / 1.6 4.8 5.27 1.273
16 3 / 2.65 5.72 6.19 1.082
16 7 / 1.7 5.10 5.95 1.128
25 7 / 2.1 6.3 9.07 0.7391
32 3 / 3.75 8.10 12.40 0.5405
32 7 / 2.46 7.4 12.44 0.5386
35 7 / 2.5 7.5 12.86 0.5215
50 7 / 3.0 9.0 18.52 0.3622
50 19 / 1.8 9.0 17.70 0.3727
70 7 / 3.55 10.65 25.93 0.2586
70 19 / 2.1 10.5 24.09 0.2738
95 19 / 2.5 12.5 34.14 0.1932
100 7 / 4.3 12.90 36.54 0.1763
120 19 / 2.8 14.0 42.83 0.154
Minimum breaking
force
Direct current resistance
Cross section
mm²
Number/Diametermm
OuterDiametre
A N D E N G I N E E R I N G S . A .
CaracteristicsThe product is difficult to damage once installed, which reduces electrical losses and reduces interference on transmission lines and radio waves.
Standards:BS 7884
Copper wire
PresentationMainly used for overhead transmission lines, long distance transmissions, transmission networks and outdoor long-range energy distribution.
6.Bare twisted copper wire
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
42
125 19 / 2.9 14.5 45.94 0.1436
150 19 / 3.2 16.0 55.94 0.118
150 37 / 2.25 15.8 53.88 0.1233
185 19 / 3.55 17.8 68.86 0.09582
185 37 / 2.5 17.5 66.49 0.09981
Name Structure Stranding
20
Minimum breaking
forceDirect current
resistance
E V E R W E L L C A M E R O O N C A B L E S
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
PRO
DU
CT C
ATA
LOG
Presentation
This series of products are mainly used for overhead insulated cables for overhead circuits with AC rated voltage of 1KV and below. Because of their certain strength and insulation performance, they are usually used in urban power grid construction.
43
Caracteristics
Operating Temperature: -20°C—90°C
Short circuit temperature:250°CInsulation: black cross linkable polyethylene insulation
Neutral conductor:High resistance stranded aluminum conductorTest wire: copper conductorPhase line: stranded aluminum conductor
Standards:BS 215-1
7.Aerial distribution and connexion
LV cables
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
A N D E N G I N E E R I N G S . A .
PRO
DU
CT C
ATA
LOG
E V E R W E L L C A M E R O O N C A B L E S
44
Main uses of the model
Registration number
Type
Number of conductors × Cross section
mm²
1
2 ABC conductors
2 * 16
2 2 * 25
3 2 * 35
4 2 * 50
5
Test lead2 ABC conductors
2*16+2*1.5
6 2*25+2*1.5
7 2*35+2*1.5
8 2*50+2*1.5
9
4 ABC conductors
4 * 16
10 4 * 25
11 4 * 35
12
4*16+2*1.5
13 4*25+2*1.5
14 4*35+2*1.5
15 ABC neutral suspension line
3*70+1*54.6+2*16
16 3*70+1*54.6+1*16
17 3*70+1*54.6
18 3*70+1*70+2*16
19 3*70+1*70+1*16
20 3*70+1*70
21 3x35+1x54.6+2x16
22 3x35+1x54.6+1x16
23 3x35+1x54.6
24 3*150+1*70+2*16
25 3*150+1*70+1*16
26 3*150+1*70
Test lead4 ABC conductors
Red Yellow Bl eu Black Orange Brown Gray White OthersG Y
These cables can be made following the customer's request.
EVERWELL CABLES
P.O. Box : 3685 Douala - Cameroon :Head office Bonapriso (Behind Castel hall)
Email : [email protected] / [email protected] Web site : www.everwell-engineering.com Tel. : (+237) 233 43 19 36 / 663 05 32 72 / 674 59 93 67 N° RCCM : RC/DLA/2018/B/2227, N° Cnb. : M091612569733M
Contacts
Copyright © 2019All rights reserved
45
A N D E N G I N E E R I N G S . A .
OHSAS18001 CertificateChinese versionEnglish version
ISO 9001 CertificateChinese version English version
34
A subsidiary
HuatongCABLES GROUP
Global Expert in Cable and Cabling System
CERTIFICATES
AND ENGINEERING S.A.E V E R W E L L C A M E R O O N C A B L E S