vers VILLEMUR Les jardins de Paule 31620 CEPET · Echelle 1/750 imprimé en A3 06/11/2014 CEPET u...

1
EU TN = 139.32 FE = 136.84 X=1573. 350 X=1573. 400 X=1573. 450 X=1573. 500 X=1573. 550 N A 1179 A 1180 A 1187 A 1188 A 1200 A 1201 A 1199 A 1198 A 1197 A 1196 A 419 A 424 A 1019 A 1020 A 1021 A 1022 A 1280 A 1281 A 1282 A 997 A 1400 A 1348 A 1204 GAZ BI EP TN = 134.80 FE = 133.65 FT FT EU TN = 138.74 FE = 136.28 EU TN = 138.98 FE = 136.50 EU TN = 139.86 FE = 137.21 EU TN = 136.57 FE = 135.16 EU TN = 134.80 FE = 133.22 A B C D E Limite A-B-C-D-E : Alignement proposé BASSIN -13.81% -16.31% -20.14% -17.14% -18.06% 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 0 10 20 30 40 50 Echelle 1/750 imprimé en A3 06/11/2014 CEPET Chemin Mourau lotissement "LES JARDINS DE PAULE" ECOLE MAIRIE vers ST SAUVEUR et BRUGUIERES vers VILLEMUR vers GRATENTOUR BP 37 - 3 place de France 31 132 BALMA CEDEX Tel : 05 61 244 799 - Fax : 05 61 241 351 E-mail: [email protected] / www.amenageurs-reunis.com 0 10 20 30 40 50 Chemin Mourau "Les jardins de Paule" 31620 CEPET position pour poste transformateur éventuel BASSIN -13.81% -16.31% -20.14% -17.14% -18.06% 5 300 m2 29,16 19,64 25,18 20,68 30,73 19,71 22,78 24,88 22,48 20,25 21,27 20,25 21,58 21,27 20,74 19,6 20,74 19,57 21,77 23 19 23 19 23 19 27,07 31,03 19 24,06 19 23,87 21,85 31,7 17 26,66 19,39 30,25 19,44 27,73 18,92 21,99 24,1 19,61 25,93 18,75 18,75 20,69 21,05 20,69 16 20,69 17,53 20,46 18,74 26,87 17 23,16 19 18,07 30

Transcript of vers VILLEMUR Les jardins de Paule 31620 CEPET · Echelle 1/750 imprimé en A3 06/11/2014 CEPET u...

EUTN = 139.32FE = 136.84

X=1573. 350

X=1573. 400

X=1573. 450

X=1573. 500

X=1573. 550

N

A 1179

A 1180

A 1187

A 1188

A 1200

A 1201

A 1199

A 1198

A 1197A 1196

A 419

A 424

A 1019A 1020A 1021A 1022

A 1280A 1281A 1282

A 997A 1400

A 1348

A 1204

GAZ

BI

EPTN = 134.80FE = 133.65

FT

FT

EUTN = 136.98FE = 134.58

EUTN = 137.97FE = 135.12

EUTN = 138.74FE = 136.28

EUTN = 138.98FE = 136.50

EUTN = 139.86FE = 137.21

EUTN = 136.57FE = 135.16

EUTN = 134.80FE = 133.22

A

B

C

D

E

Limite A-B-C

-D-E : Alignem

ent proposé

position pour poste transformateur éventuel

BASSIN

-13.81%

-16.31%

-20.

14%

-17.

14%

-18.06%

1 2 3

4 5 6 7

89

1011

12

1314

1516

17

18 19

20 21 2223

24

2526

272829

30

0 10 20 30 40 50

Echelle 1/750 imprimé en A3 06/11/2014

CEPET

Chem

in M

oura

u

lotissement!"LES JARDINS DE PAULE"

ECOLE

MAIRIEvers ST SAUVEUR et BRUGUIERES

vers VILLEMUR

vers GRATENTOUR

! BP 37 - 3 place de France 31 132 BALMA CEDEX

Tel : 05 61 244 799 - Fax : 05 61 241 351 E-mail: [email protected] / www.amenageurs-reunis.com

0 10 20 30 40 50

Chemin M

ourau

"Les jardins de Paule"!31620 CEPET

position pour poste transformateur éventuel

BASSIN

-13.81%

-16.31%

-20.

14%

-17.

14%

-18.06%

5 300 m2

29,16

19,6

425,18

20,6

8

30,73

19,71

22,78

24,88

22,48

20,25

21,27

20,25

21,58

21,27

20,74

19,6

20,74

19,57

21,77

23

19

23

19

23

19

27,0

7

31,03

19

24,06

19

23,87 21,8

5

31,717

26,6619,3

9

30,25

19,44

27,73

18,92

21,99

24,1

19,61 25,93

18,7

5

18,7

5

20,69

21,05

20,69

16

20,69

17,5320,46

18,74

26,87

17

23,16

1918,07

30