TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE...
Transcript of TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE...
![Page 1: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/1.jpg)
TECNOLOGIAS MODERNAS PARA MEDIÇÃO
CONTINUA DE EMISSÕES Aplicação em Coprocessamento na Indústria de Cimento – São
Paulo 29 de novembro de 2012
CARLOS ALBERTO TUMANG
![Page 2: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/2.jpg)
SISTEMAS DE MEDIÇÃO DE
EMISSÕES:
MC1000 Comercial Ltda.
![Page 3: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/3.jpg)
MC 1000 COMERCIAL LTDA.
Carlos Alberto Tumang
Diretor
Av. das Américas 500 Bl. 09 Lj. 122 CEP 22640-100 Rio de Janeiro - RJ - Brasil
Tel./Fax: (+55 21) 3982-2222 Cel.: (+5521) 8269-1881
E-mail: [email protected]
![Page 4: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/4.jpg)
All Cement Plants
Holcim Eclépens
Holcim Siggenthal
Holcim Untervaz
All Cement Plants are
equiped with OPSIS
JCF Cornaux
Vigier Ciment Péry JCF Wildegg
![Page 5: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/5.jpg)
AR600 : NO / NH3 / SO2 / BEN / Hg / NO2
AR650 : HCl / CO / CO2 / HF / H2O
Temp. / Press. / O2 / Dust / FID
TIS
Modbus
ComVisioner PC
Profibus
![Page 6: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/6.jpg)
MONITORAMENTO DA POLUIÇÃO ATMOSFÉRICA
-FONTES DE EMISSÕES-QUALIDADE DO AR
CARLOS ALBERTO TUMANG - MC1000 Comercial Ltda.
![Page 7: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/7.jpg)
MONITORAMENTO DA POLUIÇÃO
ATMOSFÉRICA
![Page 8: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/8.jpg)
Metodos de Amostragem Técnicas Analíticas
•In Situ - Sem coleta de amostra
• No local – termopar
• Feixe luz “Cross Stack”
• Open path (Wikipedia)
•Amostragem extrativa
•Wet-hot extractive
•Dry extractive
•DOAS
•FTIR
•IR absorption
•UV absorption
•Chemiluminescense
•UV-fluorescense
•TDL
•Etc....
METODOS E TECNICAS
![Page 9: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/9.jpg)
Sistema de Medição de Gases em Fontes de Emissão
SISTEMAS EXTRATIVOS
• Extração de Amostra
• Transporte de Amostra
até Instrumentos
• Condicionar a amostra para sua análise
• Analisadores
![Page 10: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/10.jpg)
SISTEMAS EXTRATIVOS: DILUIÇÃO
SONDA DILUIÇÃO
NOx
SO2
CO
H2O
Hg
O2
Sistema de Medição de Gases em Fontes de Emissão
![Page 11: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/11.jpg)
SISTEMAS NÃO-EXTRATIVOS
• NÃO HÁ EXTRAÇÃO: Os gases não tem
contato e não atacam os sensores
Sistema de Medição de Gases em Fontes de Emissão
![Page 12: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/12.jpg)
TECNOLOGIA OPSIS DOAS
Differential Optical Absorption Spectroscopy
![Page 13: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/13.jpg)
SISTEMAS NÃO-EXTRATIVOS: DOAS.
VANTAGENS:
• Podem medir com precisão SO2, NO2,
NO3, NO, SO3, Hg+, NH3, Benzeno, CH4,
CO, CO2, Phenol, Formaldeído, HF, HCl,
etc.
• Homologados e certificados por: TÜV,
EPA, SIREP, NPL, INERIS, EUROPEAN
RESEARCH CENTRE, CNR. Etc.
• Únicos multiparamétricos certificados por
TÜV para todos os gases, incluidos HF.
Sistema de Medição de Gases em Fontes de Emissão
![Page 14: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/14.jpg)
What Happens in the Computer?
![Page 15: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/15.jpg)
What Happens in the Computer?
1. Once the data has been collected, the raw spectrum is stored in the computer’s
memory.
2. First the raw spectrum is compared with a zero-gas spectrum. This has previously
been registered with no absorption gases present and is used as a system reference.
3. After division by the zero-gas spectrum, the total light absorption between the
transmitter and the receiver is obtained. This result is caused not just by the gases that
are present but also by e.g. dust in the atmosphere or dirty optics. The task now is to
separate the light absorption of the gases from other influence.
4. To do this, the system takes advantage of the fact that only gas molecules will cause
rapid variations in the absorption spectrum. The slow variations, which give rise to the
gradient on the absorption curve, result from a large number of known and unknown
factors. Their influence can be eliminated completely by matematically matching a curve
which does not follow the rapid variations in the spectrum.
![Page 16: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/16.jpg)
What Happens…cont’d
5. After a new division, all that remains are the rapid variations. For the remaining
calculations, the logarithm of the curve is taken, which turns the curve upside down. A
differential absorption spectrum has now been obtained. This spectrum is a
combination of the various gases present between the transmitter and the receiver at
the moment of detection. In the example this is called Z.
6-7. The gases that absorb light in this wavelength range are already known, and a pre-
recorded reference spectrum for each gas is stored in the computer’s memory. In this
example there are only two gases, called X and X. The task is to determine the
proportions of X and X that combine to give the best match for Z. The system achieves
this by very rapidly creating a new curve out of the sum of the two reference spectra,
varying values until the best correspondence is achieved.
The equation the computer uses can be expressed as CX + CX = Z, where C and C are
the proportions of each gas. From C and C it is then possible to calculate the current
concentrations.
8. Finally, the result is checked by determining the difference between the measured and
the calculated curves (the shaded area). Every measurement result can be stated with a
standard deviation. The more reference curves stored in the computer’s memory, the more
accurate the result of the calculation will be. Even if there should be some unknown
interference, the computer evaluates the gases it is programmed for.
![Page 17: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/17.jpg)
Typical Wavelength Intervals
CO
N2O CH4 HF
NO,NH3 NO2 SO2, CS2
Hg
O3
Cl2, ClO2
BTX,Phenol
Formaldehyde
CO2 HCl H2O
/nm
/nm
200 400 600
1300 1600 1900 2200 2500
AR500/AR600
Analyser
AR650
Analyser
CxHx
![Page 18: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/18.jpg)
Span and Zero Calibration – AQM
![Page 19: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/19.jpg)
Automatic Calibration – CEM
![Page 20: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/20.jpg)
CALIBRATION Manual span and zero bench calibration
Calibration bench
Calibration lamp Analyser
Standard gas
Calibration cell
![Page 21: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/21.jpg)
Calibration
gas
Rotameter
(flow control)
Receiver Emitter with
Xe lamp
Calibration bench Gas valves
CALIBRATION KIT
![Page 22: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/22.jpg)
![Page 23: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/23.jpg)
Opsis Software Packages
Alarms
Emission calculations
Data validation
Password security
Communication
Remote control
Graphic and numeric
presentation
Automatic reports
Analogue and digital
input/output interface
Statistical
analysis
![Page 24: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/24.jpg)
Data Acquisition and Validation
Presentation, Emission
Calculations
and Reporting,
Advanced analysis
of data
Dispersion Modelling
Export to Intranet/ Internet
Software Products - EnviMan
![Page 25: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/25.jpg)
Real-time data presentation.
User friendly interface
Instant feedback of the Air
Pollution Situation
Application 5
Presentation of AQM and CEM
Data
![Page 26: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/26.jpg)
Enviman Reporter
DATA PRESENTATION
![Page 27: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/27.jpg)
EMISSION CALCULATIONS
![Page 28: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/28.jpg)
Automatic Reports
![Page 29: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/29.jpg)
Data exceeding the given
level will trigger an alarm.
Data will be marked and
operators alerted.
Alarm export to almost
any output.
Enviman ComVisioner
Application 4
ALARM HANDLING
![Page 30: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/30.jpg)
Real time CEMS and metereological data is used as input for the dispersion model. The impact from industrial emissions can be followed with less than 5 minute intervals
Enviman Nowcaster
MODELAGEM EM TEMPO REAL
![Page 31: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/31.jpg)
OPSIS AB
• Fundada em 1985 por Svante Wallin e Leif Unéus
• Localizada em Furulund, Sweden.
![Page 32: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/32.jpg)
Presença mundial
![Page 33: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/33.jpg)
• Cerca de 90 sistemas
• Europa 50
• HOLCIM, 26 systems
• LAFARGE, 14 systems
Coprocessamento Referencias
![Page 34: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/34.jpg)
Cementos Bocaya, Colombia
Merone, Italy
Aalborg, Denmark Alpha
Cement,South
Africa
WORLDWIDE REFERENCES
![Page 35: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/35.jpg)
CEM location
Main Stack
![Page 36: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/36.jpg)
EMITTER
![Page 37: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/37.jpg)
RECEIVER
![Page 38: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/38.jpg)
EMITTER WITH PURGE AIR
CASSETTE
![Page 39: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/39.jpg)
![Page 40: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/40.jpg)
Making Holes in the Stack
![Page 41: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/41.jpg)
Flange ANSI 4” for Opsis
RE062 receiver
½”connection for
Temperature sensor
3” flange for
Oxygen Probe
![Page 42: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/42.jpg)
Flange ANSI 4” for
OPSIS EM062 Emitter
![Page 43: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/43.jpg)
OPSIS RE062
Receiver
![Page 44: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/44.jpg)
Emitter location Receiver
location Dust monitor location
Instrument Air System
![Page 45: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/45.jpg)
Training Session
![Page 46: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/46.jpg)
Equipment has Arrived
![Page 47: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/47.jpg)
Shelter on site
![Page 48: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/48.jpg)
Shelter is close to the stack to reduce optical fibre cable lenght
![Page 49: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/49.jpg)
![Page 50: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/50.jpg)
![Page 51: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/51.jpg)
ANALYSER CABINET
The cabinet
includes the
analysers,
screen, signal
handling, air-
conditioner and
keyboard
![Page 52: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/52.jpg)
I/O MODULES
![Page 53: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/53.jpg)
Installing the AC181 cabinet for Opsis UV and IR analysers
![Page 54: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/54.jpg)
OPSIS O2000
Oxygen analyser Power Circuit Breakers
![Page 55: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/55.jpg)
Conduits for cables and optical fibres
![Page 56: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/56.jpg)
![Page 57: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/57.jpg)
MULTIPLOS GASES CL2,HCL,HF,BTX,CH4, Hg, NH3 etc.
CERTIFICAÇÃO INTERNACIONAL
SEM AMOSTRAGEM IN-SITU – CROSS STACK
OPSIS DOAS RESUMO
![Page 58: TECNOLOGIAS MODERNAS PARA MEDIÇÃO CONTINUA DE …coprocessamento.org.br/cms/wp-content/uploads/2012/12/Tecnologias... · tecnologias modernas para mediÇÃo continua de emissÕes](https://reader034.fdocument.pub/reader034/viewer/2022052309/5bf79f9a09d3f2e7208b466f/html5/thumbnails/58.jpg)
Muito obrigado !