StyleView® SLA Change Power System Batteries · Two Sealed Lead Acid, Absorbed Glass Mat, 12VDC...
Transcript of StyleView® SLA Change Power System Batteries · Two Sealed Lead Acid, Absorbed Glass Mat, 12VDC...
1 of 10888-83-065-G-01 rev. E • 03/19
10mm (3/8")or8mm (5/16")
SV32-S
SV32-T
SV32
SV32 PHD SV423 6 8
www.ergotron.com | USA: 1-800-888-8458 | Europe: +31 (0)33-45 45 600 | China: 400-120-3051 | Japan: [email protected]
English, Español, Français, Deutsch, Nederlands, Italiano, Svenska, 日本語, 汉语
10 °C50 °F
29 °C 86 °F
RelativeHumidity
Range5-95% rH
Operational
-20 °C- 4 °F
50 °C122 °F
RelativeHumidity
Range5-95% rH
Storage
BATTERY
LEAD
Please dispose of all batteries in accordance with local law
Two Sealed Lead Acid, Absorbed Glass Mat, 12VDC batteries.
Depends on battery
StyleView® SLA
Change Power System Batteries· SV32-S
· SV32-T
· SV32
· SV32 PHD
· SV42
EnglishFor the latest User Installation Guide please visit: www.ergotron.com
User's Guide
2 of 10 888-83-065-G-01 rev. E • 03/19
Maintenance & Safety
Color Symbol Signal
WordLevel of Hazard
Red DANGERIndicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Orange WARNINGIndicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Yellow CAUTIONIndicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
None CAUTIONUsed without the safety alert symbol indicates a poten-tially hazardous situation which, if not avoided, may result in property damage.
Red,
Orange
or
Yellow
ElectricalIndicates an impending electrical hazard which, if not avoided, may result in personal injury, fi re and/or death.
Hazard Symbols Review The Meaning of Symbols appearing in this Guide, on the Cart or on the Power SystemThese symbols alert you to a safety condition that demands your attention. You should be able to recognize and understand the signifi cance of the following Safety Hazards if you encounter them on the Cart or within Cart documentation such as this Set-up Guide.
33 Amp-Hour Batteries
BATTERY
LEAD
WARNING: RISK OF ELECTRICAL DISCHARGE
• Do NOT swap battery cables, doing so will cause arcing and trip the circuit breaker.
• Do not remove or replace the batteries while cart is located in an oxygen rich or hazardous environment, arcing may occur and cause combustion.
• Replace fi rst battery before removing second battery to reduce the risk of cables touching terminals and causing arcing.
• Always replace both batteries!• Replace fi rst battery before removing second battery.• Replace batteries with same Amp/Hour rating batteries only.• Only Ergotron-specifi ed batteries may be used in the StyleView Power System. Please call customer care for more details.• Recycle battery or contact Ergotron for proper battery disposal guidelines.
20 Amp-hour Batteries
BATTERY REPLACEMENTThe power module is configured for two, 33 -Ah batteries. Only the following batteries are compatible with this system:
• B&B EP33-12 • SBS S-12330• Longway 6FM33G • Vision 6FM33D• Vision 6FM33HD-X • PBQ PBQ33-12L• Werker WKA12-33C • Werker WKA12-35C• Duracell Dura 12-35CInstalling batteries other than the 33 -Ah listed above will void the product warranty. Failure to heed this warning may result in severe damage to batteries, power module and possible fire hazard.
REMPLACEMENT DE LA BATTERIELe module d’alimentation est configuré pour deux batteries 33 A-h. Seules les batteries suivantes sont compatibles avec ce système :
• B&B EP33-12 • SBS S-12330• Longway 6FM33G • Vision 6FM33D• Vision 6FM33HD-X • PBQ PBQ33-12L• Werker WKA12-33C • Werker WKA12-35C• Duracell Dura 12-35CL’installation de batteries autres que les batteries 33 A-h citées ci-dessus annulera la garantie du produit. Si vous ne vous conformez pas à cette précaution d’utilisation, les batteries et le module d’alimentation risquent d’être sérieusement endommagés, ce qui pourrait provoquer un incendie.
WARNINGAVERTISSEMENT
822-386
www.ergotron.com
3 of 10888-83-065-G-01 rev. E • 03/19
ba c d
1 2
3
4
5
SV32-S
SV32-T
SV32
Turn off all mounted equipment. Disconnect Power System from power source.
Turn power system off by holding down the AC Outlet Power button for 1 - 3 seconds. Power light will shut off .
If your cart has circuit breakers, switch them both to "OFF".
4 of 10 888-83-065-G-01 rev. E • 03/19
6
7
8
b ca
10mm (3/8")or8mm (5/16")
b
ef
ca
d
ef
d
Red Black
BATTERY
LEAD
Caution: Remove Black (-) before removing Red (+).
Recycle battery or contact
Ergotron for proper battery
disposal guidelines.
Caution: Replace only one battery at a time.
Do NOT swap battery cables, doing so will cause
sparking and trip the circuit breakers.
Depends on battery
Black
Caution: Connect Red (+) before connecting Black (-).
Caution: Remove Black (-) before removing Red (+).
Red
Red Black
BATTERY
LEAD Recycle battery or contact
Ergotron for proper battery
disposal guidelines.
Red
Caution: Connect Red (+) before connecting Black (-).
Black
5 of 10888-83-065-G-01 rev. E • 03/19
10
11
12
a
or
b
dcba9
8hrs7 hrs
07.00
Wake power system from sleep mode by holding down the two buttons at the same time for about 7 seconds until it beeps.
Turn cart's power on by holding down the power button until it beeps.
For carts with these part numbers only:
· SV32-32001-S
· SV32-32002-S
· SV32-32025-S
· SV32-32026-S
· SV32-32051-S
· SV32-32052-S
Turn on power system by holding power buttondown for 1 - 3 seconds.
With cart's power cord plugged into the wall outlet, wait until cart is at 100% charge. (takes aproximately up to 7 hours to charge)
Plug Cart's Power Cord into wall outlet.
Do Not stretch coiled cord further than 8 feet (2.5 meters), damage to the cord may occur.
CAUTION: There is no on/off switch on this equipment; the AC power cord is the only power disconnect. The socket outlet should be easily accessible and should be installed near the equipment.
Initial Power on/Charge
Battery (takes aproximately 7 hours to charge)
All other powered StyleView (SV32) carts
6 of 10 888-83-065-G-01 rev. E • 03/19
a
a
b
b
c
c
bca
ef
d
SV32 PHD
1
2
3
4
Turn off all mounted equipment. Disconnect Power System from power source.
Turn power system off by holding down the AC Outlet Power button for 1 - 3 seconds. Power light will shut off .
BATTERY
LEAD Recycle battery or contact
Ergotron for proper battery
disposal guidelines.
Caution: Replace only one battery at a time.
Do NOT swap battery cables, doing so will cause
sparking and trip the circuit breakers.
Turn both circuit breakers to "OFF".
RedBlack
Caution: Remove Black (-) before removing Red (+).
Red
Caution: Connect Red (+) before connecting Black (-).
Black
7 of 10888-83-065-G-01 rev. E • 03/19
b c
a
ef
d
8
7
6
5
a
c
b
8hrs7 hrs
07.00
BATTERY
LEAD Recycle battery or contact Ergotron for
proper battery disposal guidelines.
RedBlack
Caution: Remove Black (-) before removing Red (+).
Red
Caution: Connect Red (+) before connecting Black (-).
Black
Initial Power on/Charge Battery (takes aproximately 7 hours to charge)
Turn on power system by holding power buttondown for 1 - 3 seconds.
With cart's power cord plugged into the wall outlet, wait until cart is at 100% charge. (takes aproximately up to 7 hours to charge)
Plug Cart's Power Cord into wall outlet.
Do Not stretch coiled cord further than 8 feet (2.5 meters), damage to the cord may occur.
CAUTION: There is no on/off switch on this equipment; the AC power cord is the only power disconnect. The socket outlet should be easily accessible and should be installed near the equipment.
Note: If StyleLink is installed, it will report battery status “checking” until battery has gone through one full cycle (charge to 100%, discharge to < 70%, and then plug cart into wall outlet). After battery has gone through one full cycle, StyleLink will provide battery status. In the event that StyleLink still reports status “checking’, repeat the discharge / recharge and plug in.
8 of 10 888-83-065-G-01 rev. E • 03/19
a b c
b
b
g
c
e
h
a
d
f
10mm (3/8")
SV42
1
2
3
a
Turn off all mounted equipment. Disconnect Power System from power source. Turn power system off by holding down the AC Outlet Power button for 1 - 3 seconds. Power light will shut off .
Turn both circuit breakers to "OFF".
Red
Red
Black
Black
BATTERY
LEAD
Caution: Remove Black (-) before removing Red (+).
Recycle battery or contact
Ergotron for proper battery
disposal guidelines.
Caution: Replace only one battery at a time. Do NOT swap battery cables, doing so will cause sparking and trip the circuit breakers.
Caution: Connect Red (+) before connecting Black (-).
9 of 10888-83-065-G-01 rev. E • 03/19
5
b
a
b
g
c
e
h
a
d
f
4
Black
Black
Red
Red
BATTERY
LEAD
Caution: Remove Black (-) before removing Red (+).
Recycle battery or contact
Ergotron for proper battery
disposal guidelines.
Caution: Replace only one battery at a time. Do NOT swap battery cables, doing so will cause sparking and trip the circuit breakers.
Caution: Connect Red (+) before connecting Black (-).
10 of 10 888-83-065-G-01 rev. E • 03/19
6a b c
8hrs7 hrs
07.00
© 2012 Ergotron, Inc. All rights reserved. StyleView™ is a registered trademark of Ergotron, Inc.
www.ergotron.com | USA: 1-800-888-8458 | Europe: +31 (0)33-45 45 600 | China: 400-120-3051 | Japan: [email protected]
Initial Power on/Charge Battery (takes aproximately 7 hours to charge)
Turn on power system by holding power button down for 1 - 3 seconds.
With cart's power cord plugged into the wall outlet, wait until cart is at 100% charge. (takes aproximately up to 7 hours to charge)
Plug Cart's Power Cord into wall outlet.
Do Not stretch coiled cord further than 8 feet (2.5 meters), damage to the cord may occur.
CAUTION: There is no on/off switch on this equipment; the AC power cord is the only power disconnect. The socket outlet should be easily accessible and should be installed near the equipment.
Note: If StyleLink is installed, it will report battery status “checking” until battery has gone through one full cycle (charge to 100%, discharge to < 70%, and then plug cart into wall outlet). After battery has gone through one full cycle, StyleLink will provide battery status. In the event that StyleLink still reports status “checking’, repeat the discharge / recharge and plug in.
For local customer care phone numbers visit: http://contact.ergotron.comFor Service visit: www.ergotron.comFor Warranty visit: www.ergotron.com/warranty