Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

6
Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

description

Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou. ☆Helium bag design and arrangement. ・Helium bag is designed for reducing multiple scattering in D5 magnet. ・D5 magnet have arch formed hole. The hole size is 380×120. - PowerPoint PPT Presentation

Transcript of Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

Page 1: Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

Status report for Helium bag and Gauss meter installation for D5

2009.9.24Hiroshi Kou

Page 2: Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

☆Helium bag design and arrangement

・ Helium bag is designed for reducing multiple scattering in D5 magnet.

・ D5 magnet have arch formed hole.

The hole size is 380×120.

・ Helium bag is designed through the magnet’s hole.

・ The bag’s thickness is 38μm about the part of passing particles . (the other part is all 50μm )

・ The bag is made using Mylar.

・ gas connector is connected sinflex tube (called 64)

・ The bag is manufacturing now and delivered September 24th or 25th.

Fig.1 the design of D5 magnet

Fig.2 the design of Helium bag

Part of passing particles

arch formed hole end guard

Page 3: Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

☆The arrangement plan about Gauss meter

・ In D5 magnet,magnet's center and particle's orbit center is different (~60.9mm)

・ The center of magnet is ~1100mm from end-guard and Gauss meter's tube is ~2000mm.

・ we put hole probe on the magnet center

・ I designed Gauss meter and hole probe holder.

60.9

red:particle orbitblue:magnet center

Fig 3.difference of center in D5 magnet

68.75°

55°

Gauss meter

1100

Hole probe

Page 4: Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

☆the design of hole probe holder

・ hole probe holder will be arranged,from the end-guard to the magnet center

・ the probe has to be fixed perpendicularly to the magnetic field

・ clear cover is designed to protect probe's head from the helium bag's pressure

Magnet center

end-guard

3

Fig.4 the design of hole probe holder

Probe

Clear cover

Page 5: Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

☆the design of Gauss meter holder

・ There is a limited space to install the Gauss meter holder between D5 end-guard and Beam-line chamber.

・ aluminum plate(the thickness is ~1cm) is necessary for attaching the Gauss meter holder

・ we need request support for tapped holes to fix aluminum plate on D5 magnet

Fig5. The arrangement plan chamber and CDC

end-guard

Gauss meterholder

Aluminum plate

Fig 6.the arrangement plan of Gauss meter holder

Anchorhole

D5 end-guard

Beam linechamber

CDS

beam

6.875°

~6cm56cm

Page 6: Status report for Helium bag and Gauss meter installation for D5 2009.9.24 Hiroshi Kou

☆time table

・ Range stack holder → installed already

・ Helium bag → delivered by September 24th or 25th

・ Hole probe holder and Gauss meter holder → manufacturing now,delivered until September 28th and installed around September 30th