SDR Hardware and Fault Treatment Brief Introduction

42
SDR Hardware and Fault Treatment Brief Introduction Chen Jie Chen Jie 2010-12-4 2010-12-4

description

troubleshooting

Transcript of SDR Hardware and Fault Treatment Brief Introduction

Page 1: SDR Hardware and Fault Treatment Brief Introduction

SDR Hardware and Fault Treatment Brief Introduction

Chen JieChen Jie

2010-12-42010-12-4

Page 2: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

Directory 1 、 硬件介绍( 09:00~11:00 ) Hardware Brief Introduction 2 、 LMT 的使用 / Usage of LMT ( 11:10~11:30 ) 3 、常见故障处理( 13:30~15:30 ) Common Fault Treatment 4 、两种 RRU/RSU 的区分和替换( 11:30~12:00 ) Distinguish and exchange between

RRU/RSU 5 、现场提问 / Q&A(15:30~16:00) 6 、 6370 站点现场讲解( 16:30~18:00 ) Demo of 6370

Page 3: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

SDR : Software Define Radio ,软件定义无线电

The base band and RF unit are in the same module in V2,3 BTS. ZTE SDR BBU and RU are separated 。

lower power consumption 。

SDR compare with the V2,3 BTS

Page 4: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

ZTE SDR structure

BBU ( B8200 ) +RRU(R8860) /RU(RSU60)BBU: BaseBand UnitRRU: Remote Radio UnitRU: Radio Unit,

ZTE SDR station family BS8900: OutdoorBS8800: IndoorBS8700: BBU indoor; RRU indoor or outdoorBS8906: Outdoor; microcell

R8860 R8860E ; RSU60 RSU60E

Page 5: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

Pakistan SDR BTS Family and composing

8700:BS8900A-BC8910A Rack+R88608900:BS8900A-BC8910A Rack+RC8910A Rack8800:BS8800 Rack

BC8910A Rack : 1 BBU is in BTS RACK of outdoor 、 LPU, DDF, DCPD,FAN, to process Baseband functionRC8910A Rack : 6 RSU RF unit in 1 rack of outdoor 、 FAN and DCPD to process RF function.BS8800 Rack : indoor cabinet , BBU and RSU inside , to process baseband and RF function.R8860 : Remote RF unit, the same function as RSU to process RF funtion.

1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

Page 6: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲8700 Schematic diagram

Page 7: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲8900

Schematic diagram

Page 8: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

8800 Schematic diagram

Page 9: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

BBU and Board1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

缩写 英文全称 中文名称CC Control and Clock Module 控制与时钟板

UBPGUniversal Baseband Processing Board for GSM

通用 GSM 基带处理板

FS Fabric Switch Module 网络交换板SA Site Alarm Module 现场告警板SE Site Alarm Extension Module 现场告警扩展板NIS Network Interface of STM-1 STM-1 网络接口板PM Power Module 电源模块FA FAN Module 风扇模块

Page 10: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

CC Board Introduction

Page 11: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

UBPG Board Introduction

Page 12: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

FS Board Introduction

Page 13: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

SA Board Introduction

Page 14: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

SA Board Jumper

Page 15: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲E1 Cable

Page 16: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

Page 17: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲RSU /RRU Implements

Page 18: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

RSU60 Module Introduction

RSU60

RSU60E

RSU60 Panel and Interfaces Reference 《 BS8800 GU360(V4.00.21) Indoor GSM&UMTS Macro Node B Hardware Description 》

Page 19: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲RRU Introduction

RSU60 Panel and Interfaces Reference 《 BS8700 (V4.00.30) Hardware Description 》

Page 20: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

室外防雷箱内电源线和干结点线缆连接方法

OLP Power Cable and Dry Contact Cable

Page 21: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲1 、 Hardware Brief Introduction1 、 Hardware Brief Introduction

OLP Dry Contact Cable

Page 22: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

Directory 1 、 硬件介绍( 09:00~11:00 ) Hardware Brief Introduction 2 、 LMT 的使用 / Usage of LMT ( 11:10~11:30 ) 3 、常见故障处理( 13:30~15:30 ) Common Fault Treatment 4 、两种 RRU/RSU 的区分和替换( 11:30~12:00 ) Distinguish and exchange between

RRU/RSU 5 、现场提问 / Q&A(15:30~16:00) 6 、 6370 站点现场讲解( 16:30~18:00 ) Demo of 6370

Page 23: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

2 、 Usage of LMT 2 、 Usage of LMT

Software install and login 软件安装和登录顺序Install Java—install LMT software—run LMT—set IP ,Set your PC IP —login SDR BTS

BBU CC IP: 192.254.1.16Computer IP: 192.254.1.*

JAVA folder :

Page 24: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

2 、 Usage of LMT 2 、 Usage of LMT

LMT folder :

LMT run :

Page 25: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

2 、 Usage of LMT 2 、 Usage of LMT

Set Station IP

Page 26: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

2 、 Usage of LMT 2 、 Usage of LMT

login

Page 27: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

Directory 1 、 硬件介绍( 09:00~11:00 ) Hardware Brief Introduction 2 、 LMT 的使用 / Usage of LMT ( 11:10~11:30 ) 3 、常见故障处理( 13:30~15:30 ) Common Fault Treatment 4 、两种 RRU/RSU 的区分和替换( 11:30~12:00 ) Distinguish and exchange between

RRU/RSU 5 、现场提问 / Q&A(15:30~16:00) 6 、 6370 站点现场讲解( 16:30~18:00 ) Demo of 6370

Page 28: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲3 、 Common Fault Treatment3 、 Common Fault Treatment

RU common Alarm is as follows:

Board communication link interruptedOutdoor lightning protection box alarm Remote Antenna Vswr Alarm Remote antenna over VSWR alarm Improper DPD running status

RU Alarm

Page 29: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲3 、 Common Fault Treatment3 、 Common Fault Treatment

RU AlarmBoard communication link interrupted

Advice :Maintenance team meet this alarm. First check optical fiber, if not ok, check the RU or FS board.Change order : optical interface 、 optical fiber 、 RU、 FS board 。

Page 30: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲3 、 Common Fault Treatment3 、 Common Fault Treatment

RU Alarm

Remote Antenna VSWR AlarmRemote antenna over VSWR alarm

Advise :The same as V3 VSWR alarm 。 If VSWR of antenna is ok, need to change the RU. 。If the alarm is over VSWR alarm, reset the RU after you do the active, the alarm can disappear.

Page 31: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲3 、 Common Fault Treatment3 、 Common Fault Treatment

About RU Alarm

Outdoor lightning protection box alarm

If happening at SWAP time , this alarm maybe due to cable connection of LPB is wrong. If happening at Maintenance time, this alarm may be due to LPB is fault. Maybe need to change the LPBHere is the cable connection 。 Refer to this map。

Improper DPD running status

This alarm will affect network quality 。 Need to reset the RU, otherwise should be change the RU.

Page 32: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲3 、 Common Fault Treatment3 、 Common Fault Treatment

About CC AlarmThose alarm are due to the transmission. You should check the transmission.If you want to re-patch the EI , SDR E1 Refer to this map

One thing more , if Relay circuit fault appear on CC board , the alarm due to Lucid Channel is not working of eass. Check the MISSU of MISU.

Page 33: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

UBPG: Antenna data link error alarmFS: Loss of Signal at Ir interface

3 、 Common Fault Treatment3 、 Common Fault Treatment

UBPG & FS Alarm

If these two alarms appear , RU should hasBoard communication link interrupted alarm 。 Check the RU,the alarm will be disappear after RU running normal 。

BBU Board & FCE & Fan Alarm

Board communication link interruptedIf BBU or FCE have Board communication link interrupted alarm , the board or FCE is fault. Change the fault board 。

Fan alarmIf Fan alarm appear on FCE , should change the Fan or subrack 。 8700 Schematic diagram。

Page 34: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲3 、 Common Fault Treatment3 、 Common Fault Treatment

Dry Contact Alarm

SDR Dry contact alarm have two parts , One is from FCE , the other is from SA 。 You can see the B/W tableFCE dry contact alarm is from SDR itself. Like : BC door alarm 、 water proof 、 SMOG faultSA dry contact alarm is like V3.If you want to repatch the cableRegard this map。

Board Type Alarm Code Remark

FCE5Self-defined dry contact alarm(198084317) Dry Contact Alarm Content:BC gate safety signal

From SDR itself

SASelf-defined dry contact alarm(198084317) Dry Contact Alarm Content:Water Leakage Alarm From EASS

SA Self-defined dry contact alarm(198084317) Dry Contact Alarm Content:DG Low Fuel

Page 35: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲3 、 Common Fault Treatment3 、 Common Fault Treatment

SITE Reset: CC Board Reset (in configuration management)

Page 36: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

Directory 1 、 硬件介绍( 09:00~11:00 ) Hardware Brief Introduction 2 、 LMT 的使用 / Usage of LMT ( 11:10~11:30 ) 3 、常见故障处理( 13:30~15:30 ) Common Fault Treatment 4 、两种 RRU/RSU 的区分和替换( 11:30~12:00 ) Distinguish and exchange between

RRU/RSU 5 、现场提问 / Q&A(15:30~16:00) 6 、 6370 站点现场讲解( 16:30~18:00 ) Demo of 6370

Page 37: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

4 、 Distinguish and exchange between RRU/RSU4 、 Distinguish and exchange between RRU/RSU

You can see the difference between RSU60 and RSU60E. R8860 and R8860E outlook 。

RSU60E and R8860E are advanced RSU60 and R8860 RF unit.

They change each other should change the configuration of BTS and BSC both end and reload the software.

Note: The RSU60 can not replace RSU60E , or R8860 replace R8860E 。

Page 38: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

Directory 1 、 硬件介绍( 09:00~11:00 ) Hardware Brief Introduction 2 、 LMT 的使用 / Usage of LMT ( 11:10~11:30 ) 3 、常见故障处理( 13:30~15:30 ) Common Fault Treatment 4 、两种 RRU/RSU 的区分和替换( 11:30~12:00 ) Distinguish and exchange between

RRU/RSU 5 、现场提问 / Q&A(15:30~16:00) 6 、 6370 站点现场讲解( 16:30~18:00 ) Demo of 6370

Page 39: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

5 、 Q & A5 、 Q & A

Page 40: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

Directory 1 、 硬件介绍( 09:00~11:00 ) Hardware Brief Introduction 2 、 LMT 的使用 / Usage of LMT ( 11:10~11:30 ) 3 、常见故障处理( 13:30~15:30 ) Common Fault Treatment 4 、两种 RRU/RSU 的区分和替换( 11:30~12:00 ) Distinguish and exchange between

RRU/RSU 5 、现场提问 / Q&A(15:30~16:00) 6 、 6370 站点现场讲解( 16:30~18:00 ) Demo of 6370

Page 41: SDR Hardware and Fault Treatment Brief Introduction

Internal Use Only ▲

6 、 Demo of 63706 、 Demo of 6370

Page 42: SDR Hardware and Fault Treatment Brief Introduction