Scambiatori ispezionabili TTT
-
Upload
dfi-energia -
Category
Documents
-
view
255 -
download
6
description
Transcript of Scambiatori ispezionabili TTT
t.t.t. total transfer technology S.r.l.Sede legale: Via Gorizia, 647122 - Forlì - ITALYTel. +39 045 7514142 - Fax +39 045 [email protected] - www.totaltransfer.it
Scambiatori di calore a piastre
Plate heat exchangers
s c a m b i a t o r i d i c a l o r e a p i a s t r e p l a t e h e a t e x c h a n g e r s
s c a m b i a t o r i d i c a l o r e a p i a s t r e p l a t e h e a t e x c h a n g e r s
indice/contents
06
07
08
10
11
12
14
SCAMBIATORI DI CALORE A PIASTRE ISPEZIONABILIGASKETED PLATE HEAT EXCHANGERS
Attacco filettato / Threaded fitting DN 32 / DN 40 / DN 50FP043 / FP081 / FP14 / FP20 / FP10 / FP16 / FP22
Attacco flangiato / Flanged fitting DN 100FP205 / FP31 / FP40 / FP50 / FP71
Attacco flangiato / Flanged fitting DN 150FP41 / FP60 / FP80 / FP42 / FP62 / FP82 / FP112
Attacco flangiato / Flanged fitting DN 200FP405 / FP70 / FP100 / FP130
Attacco flangiato / Flanged fitting DN 300FP81 / FP120 / FP160 / FP190
Attacco flangiato / Flanged fitting DN 500FP150 / FP200 / FP250 / FP300
SCAMBIATORI DI CALORE A PIASTRE SALDO-BRASATEBRAZED PLATE HEAT EXCHANGERS
GPLT4 / GPLT5 / GPLT7 / GPLT8
Abbinamenti materiali/Material matching table
1. Canale di mandata o ritorno
2. Distributore: zona della piastra destinata a diffondere uniformemente il fluido lungo tutta la piastra
3. Zona di scambio termico. Disponibile in diverse corrugazioni per massimizzare lo scambio termico e ridurre le perdite di pressione.
4. Guarnizione Clip-on disponibile in NBR, EPDM o VITON
5. Zona di sicurezza: la doppia barriera della guarnizione e la via di fuga impedisce la contaminazione dei due circuiti in caso di rottura della guarnizione.
1. Delivery or return channel
2. Header: area of the plate which distributes the fluid evenly throughout the entire plate surface.
3. Heat exchange area. Different corrugation profiles are available to maximize heat exchange and minimize pressure drop.
4. Clip-on gasket available in NBR, EPDM or VITON.
5. Safety: the double gasket and outer leakage groove prevents primary and secondary fluids from mixing if one of the two gaskets fails.
04
Scambiatori a piastre ispezionabili con attacco filettatoGli scambiatori di calore a piastre ispezionabili T.T.T. della serie FP sono frutto dell’esperienza pluriennale dell’azienda nel settore.Alta efficienza, dimensioni compatte ed affidabilità sono alla base della gamma di scambiatori a piastre ispezionabili T.T.T.Disponibili versioni con connessioni a partire da DN 32 mm filettato fino a DN 500 flangiate. Guarnizioni Clip-on ed uno speciale disegno del telaio permettono una facile e veloce ispezione dello scambiatore.
Gasketed plate heat exchangers with threaded fittingT.T.T. FP series gasketed plate heat exchangers result from long experience in the field.High efficiency, compact design and reliability are the key features of the range of T.T.T. gasketed plate heat exchangers.Available with threaded fittings from DN 32 mm and with flanged fittings up to DN 500.Clip-on glue free gaskets and a special design of the frame ensure a rapid and easy inspection of the exchanger.
1
2
34
5
Piastre/Plates
Guarnizioni/Gaskets
Telaio/Frame
ACCIAIO AL CARBONIO
CARBON STEEL
ACCIAIO INOX AISI 304
STAINLESS STEEL AISI 304
ACCIAIO INOXAISI 316
STAINLESSSTEEL AISI 316
TITANIOTITANIUM
SMOSMO
EPDMEPDN
NBRNBR
VITONVITON
Scambiatori di calore a piastre ispezionabiliGasketed plate heat exchangers
05
ACCESSORI E OPTIONALSCoibentazione realizzata il elastomero espanso a cellula chiusa anti-condensa il tutto contenuto in un box ispezionabile in lamiera di alluminio.Vaschetta raccolta gocce dotato di connessione per scarico.Piedi di ancoraggio a terra.Verniciature particolari.
ACCESSORIES AND OPTIONALSInsulation made of closed-cellelastomeric foam preventingthe formation of condensate and contained within a removable casing made of aluminium sheet.Condensate collection tank with draining coupling.Feet for ground anchoring.Special paintings.
Beispiel eines Prinzip-Anschlussplans
INOX AISI 304STAINLESS STEEL AISI 304
INOX AISI 316STAINLESS STEEL AISI 316
NYLONNYLON
RICAVATA SUL FUSTO/GROOVEON BODY
CON RUBBER LINERWITH RUBBER LINER
CON METAL LINER/WITH METAL LINER
CON FLANGIA LIBERA/WITH FREE FLANGE
CON FLANGIA SALDATA/WITH WELDED FLANGE
Esecuzione standard / Standard version
Esecuzione su richiesta / Version on request
Connessioni scambiatori a piastre/Plate exchanger couplings
Connessioni/ModelloCouplings/Model CONNESSIONE FILETTATA/THREADED COUPLING CONNESSIONE FLANGIATA/FLANGED COUPLING
FP043/FP081
FP14/FP20/FP10/FP16/FP22
FP205/FP31/FP40/FP50/FP71
FP41/FP60/FP80/FP42/FP82/FP112
FP405/FP70/FP100/FP130
FP81/FP120/FP160/FP190
FP150/FP200/FP250/FP300
06
Layout connessioni possibili / Layout of allowed couplings
Con piastre offset attenersi esclusivamente al layout indicato nella scheda di calcolo.Con circuito primario si intende quello più caldo che cede calore.Con circuito secondario si intende quello più freddo che prende calore.With offset plates: strictly respect the layout shown in the calculation sheet.By primary circuit it is meant the hotter one which releases heat.By secondary circuit it is meant the cooler one which receives heat.
Model Coupling Plate Max working A B C D E PP Number of L2 Diameter surface area pressure plates
m2 bar mm mm
FP043 1”1/4 GAS M 0.042 16 470 200 380 68 45 NPx3,1+2 NP≤14 165
14<NP≤38 263
38<NP≤64 363
FP081 1”1/2 GAS M 0.085 16 725 250 555 100 90 NPx3,05+2 NP≤14 265
14<NP≤38 385
38<NP≤64 485
64<NP≤90 785
FP14 2” GAS M 0.14 16 837 310 590 135 132 NPx2,4 0<NP≤150 340-1090
FP20 2” GAS M 0.20 16 1066 310 819 135 132 NPx2,4 0<NP≤150 340-1090
FP10 2” GAS M 0.10 16 735 310 494 126 128 NPx2,4 NP≤60 590
60<NP≤150 1090
FP16 2” GAS M 0.14 16 932 310 694 126 128 NPx2,9+3 NP≤60 590
60<NP≤150 1090
FP22 0.22 16 1132 310 894 126 128 NPx2,9+3 NP≤60 590
60<NP≤150 1090
Modello Diametro Superficie Pressione A B C D E PP Numero L2 Connessioni Piastra massima di Piastre esercizio
PRIMARIO/PRIMARY SECONDARIO/SECONDARY
INGRESSO/IN USCITA/OUT INGRESSO/IN USCITA/OUT
1F 4F 3F 2F
4F 1F 2F 3F
3F 2F 1F 4F
2F 3F 4F 1F
Scambiatori di calore a piastre ispezionabiliGasketed plate heat exchangers
FP043/FP081/FP14/FP20/FP10/FP16/FP22
Scambiatori a piastre ispezionabili con attacco filettato DN32/DN40/DN50Gasketed plate heat exchangers with threaded fitting DN32/DN40/DN50
3F 4F
2F 1F
L2
PP
A C
E
B
D
07
Layout connessioni possibili / Layout of allowed couplings
Con piastre offset attenersi esclusivamente al layoutindicato nella scheda di calcolo.Con circuito primario si intende quello più caldo che cede calore. Con circuito secondario si intende quello più freddo che prende calore.With offset plates: strictly respect the layout shown in the calculation sheet.By primary circuit it is meant the hotter one whichreleases heat. By secondary circuit it is meant the cooler one which receives heat.
PRIMARIO/PRIMARY SECONDARIO/SECONDARY
INGRESSO/IN USCITA/OUT INGRESSO/IN USCITA/OUT
F1 F4 F3 F2
F4 F1 F2 F3
F3 F2 F1 F4
F2 F3 F4 F1
F1 F2
F4 F3
D
B
EC A
L2
PP
Model Coupling Plate Max. working A B C D E PP Number L2 diameter surface area pressure of plates
m2 bar mm mm
FP205 DN 100 UNI PN 16 0.21 16 1160 480 719 225 204 NPx3.1* NP≤60 620
60<NP<150 1120
FP31 DN 100 UNI PN 16 0.30 16 1332 480 894 225 204 NPx3.1* NP≤60 620
60<NP≤150 1120
FP40 DN 100 UNI PN 16 0.40 16 1579 480 1141 225 204 NPx3.1* NP≤60 620
60<NP≤150 1120
FP50 DN 100 UNI PN 16 0.50 16 1826 480 1388 225 204 NPx3.1* NP≤60 620
60<NP≤150 1120
FP71 DN 100 UNI PN 16 0.70 10 - 16 - 25 2320 480 1882 225 204 NPx3.1* NP≤60 600
60<NP≤150 1100
150<NP≤250 1600
250<NP≤350 2100
350<NP≤500 2600
500<NP≤600 3100
Modello Diametro Superficie Pressione A B C D E PP Numero L2 connessioni piastra massima di piastre esercizio
* con rubber line NPx3,1+1,5* with rubber line NPx3,1+1,5
Scambiatori di calore a piastre ispezionabiliGasketed plate heat exchangers
FP205/FP31/FP40/FP50/FP71
Scambiatori a piastre ispezionabili con attacco flangiato DN100Gasketed plate heat exchangers with flanged fitting DN100
08
F1 F2
F4 F3
D
BE
C A
L2
PP
Model Coupling Plate surface Max working A B C D E PP Number of L2 diameter area pressure plates
m2 bar mm mm
FP41 DN 150 UNI PN 16 0.40 10 - 16 - 25 1470 620 941 290 225 NPx3.5 NP≤80 860
80<NP≤130 1110
130<NP≤220 1610
220<NP≤300 2110
300<NP≤500 3110
500<NP≤700 4110
FP60 DN 150 UNI PN 16 0.60 10 - 16 - 25 1835 620 1306 290 225 NPx3.5 NP≤80 860
80<NP≤130 1110
130<NP≤220 1610
220<NP≤300 2110
300<NP≤500 3110
500<NP≤700 4110
FP80 DN 150 UNI PN 16 0.80 10 - 16 - 25 2200 620 1671 290 225 NPx3.5 NP≤80 860
80<NP≤130 1110
130<NP≤220 1610
220<NP≤300 2110
300<NP≤500 3110
500<NP≤700 4110
Scambiatori di calore a piastre ispezionabiliGasketed plate heat exchangers
FP41/FP60/FP80
Scambiatori a piastre ispezionabili con attacco flangiato DN150Gasketed plate heat exchangers with flanged fitting DN150
Modello Diametro Superficie Pressione A B C D E PP Numero L2 connessioni piastra massima di piastre esercizio
09
F1 F2
F4 F3
D
B
EC A
L2
PP
Model Coupling Plate surface Max working A B C D E PP Number of plates L2 diameter area pressure
m2 bar mm mm
FP42 DN 150 UNI PN 16 0.40 10 - 16 - 25 1470 620 941 290 225 NPx3.1 NP≤80 860
80<NP≤130 1110
130<NP≤220 1610
220<NP≤300 2110
300<NP≤500 3110
500<NP≤700 4110
FP62 DN 150 UNI PN 16 0.60 10 - 16 - 25 1835 620 1306 290 225 NPx3.5 NP≤80 860
80<NP≤130 1110
130<NP≤220 1610
220<NP≤300 2110
300<NP≤500 3110
500<NP≤700 4110
FP82 DN 150 UNI PN 16 0.80 10 - 16 - 25 2200 620 1671 290 225 NPx3.5 NP≤80 860
80<NP≤130 1110
130<NP≤220 1610
220<NP≤300 2110
300<NP≤500 3110
500<NP≤700 4110
FP112 DN 150 UNI PN 16 1.15 10 - 16 - 25 2687 620 2157 290 225 NPx3.5 NP≤80 860
80<NP≤130 1110
130<NP≤220 1610
220<NP≤300 2110
300<NP≤500 3110
500<NP≤700 4110
Scambiatori di calore a piastre ispezionabiliGasketed plate heat exchangers
FP42/FP62/FP82/FP112
Modello Diametro Superficie Pressione massima A B C D E PP Numero Piastre L2 connessioni piastra di esercizio
010
F1 F2
F4 F3
D
BE
C A
L2
PP
Model Coupling Plate surface Max working A B C D E PP Number of plates L2 diameter area pressure
m2 bar mm mm
FP405 DN 200 UNI PN 16 0.41 10 - 16 - 25 1380 760 770 395 285 NPx3.1 NP≤150 1110
150<NP≤250 1610
250<NP≤350 2110
350<NP≤450 2610
450<NP≤550 3110
550<NP≤750 4110
FP70 DN 200 UNI PN 16 0.70 10 - 16 - 25 1740 760 1130 395 285 NPx3.1 NP≤150 1110
150<NP≤250 1610
250<NP≤350 2110
350<NP≤450 2610
450<NP≤550 3110
550<NP≤750 4110
FP100 DN 200 UNI PN 16 1.00 10 - 16 - 25 2100 760 1490 395 285 NPx3.1 NP≤150 1110
150<NP≤250 1610
250<NP≤350 2110
350<NP≤450 2610
450<NP≤550 3110
550<NP≤750 4110
FP130 DN 200 UNI PN 16 1.30 10 - 16 - 25 2460 760 1850 395 285 NPx3.1 NP≤150 1110
150<NP≤250 1610
250<NP≤350 2110
350<NP≤450 2610
450<NP≤550 3110
550<NP≤750 4110
Modello Diametro Superficie Pressione A B C D E PP Numero di piastre L2 connessioni piastra massima di esercizio
Scambiatori di calore a piastre ispezionabiliGasketed plate heat exchangers
FP405/FP70/FP100/FP130
Scambiatori a piastre ispezionabili con attacco flangiato DN200Gasketed plate heat exchangers with flanged fitting DN200
011
F1 F2
F4 F3
D
B
EC A
L2
PP
Model Coupling Plate surface Max working A B C D E PP Number of plates L2 diameter area pressure
m2 bar mm mm
FP81 DN 300 UNI PN 16 0.80 6 - 10 - 16 - 25 1930 980 1100 480 365 NPx3.8 NP≤201 2090
201<NP≤301 2590
301<NP≤401 3090
401<NP≤501 3590
501<NP≤601 4090
601<NP≤701 4590
FP120 DN 300 UNI PN 16 1.20 6 - 10 - 16 - 25 2320 980 1490 480 365 NPx3.8 NP≤201 2090
201<NP≤301 2590
301<NP≤401 3090
401<NP≤501 3590
501<NP≤601 4090
601<NP≤701 4590
FP160 DN 300 UNI PN 16 1.60 6 - 10 - 16 - 25 2710 980 1879 480 365 NPx3.8 NP≤201 2090
201<NP≤301 2590
301<NP≤401 3090
401<NP≤501 3590
501<NP≤601 4090
601<NP≤701 4590
FP190 DN 300 UNI PN 16 1.90 6 - 10 - 16 - 25 3100 980 2267 480 365 NPx3.8 NP≤201 2090
201<NP≤301 2590
301<NP≤401 3090
401<NP≤501 3590
501<NP≤601 4090
601<NP≤701 4590
Scambiatori di calore a piastreGasketed plate heat exchanger
FP81/FP120/FP160/FP190
Scambiatori a piastre ispezionabili con attacco flangiato DN300Gasketed plate heat exchangers with flanged fitting DN300
Modello Diametro Superfice Pressione A B C D E PP Numero piastre L2 connessioni piastra massima di esercizio
012
F1 F2
F4 F3
D
BE
C A
L2
PP
Model Coupling Plate surface Max working A B C D E PP Number of plates L2 diameter area pressure
m2 bar mm mm
FP150 DN 500 UNI PN 16 1.50 6 - 10 - 16 2500 1370 1466 672 480 NPx4.1 NP≤201 2310
201<NP≤301 2810
301<NP≤401 3310
401<NP≤501 3810
501<NP≤601 4310
601<NP≤701 4810
FP200 DN 500 UNI PN 16 2.00 6 - 10 - 16 2855 1370 1822 672 480 NPx4.1 NP≤201 2310
201<NP≤301 2810
301<NP≤401 3310
401<NP≤501 3810
501<NP≤601 4310
601<NP≤701 4810
FP250 DN 500 UNI PN 16 2.50 6 - 10 - 16 3211 1370 2178 672 480 NPx4.1 NP≤201 2310
201<NP≤301 2810
301<NP≤401 3310
401<NP≤501 3810
501<NP≤601 4310
601<NP≤701 4810
FP300 DN 500 UNI PN 16 2.50 6 - 10 - 16 3567 1370 2534 672 480 NPx4.1 NP≤201 2310
201<NP≤301 2810
301<NP≤401 3310
401<NP≤501 3810
501<NP≤601 4310
601<NP≤701 4810
Modello Diametro Superficie Pressione A B C D E PP Numero di piastre L2 connessioni piastra massima di esercizio
Scambiatori di calore a piastre ispezionabiliGasketed plate heat exchangers
FP150/FP200/FP250/FP300
Scambiatori a piastre ispezionabili con attacco flangiato DN500Gasketed plate heat exchangers with flanged fitting DN500
013
FP30
0
FP25
0
FP20
0
FP19
0
FP16
0
FP12
0
FP81 FP
130
FP10
0
FP70
FP40
5 FP80
FP60
FP41 FP
50
FP40
FP31
FP20
5
FP19 FP22
FP16
FP10 FP
20
FP14
FP82
FP04
3
t.t.t. total transfer technology S.r.l.Sede legale: Via Gorizia, 647122 - Forlì - ITALYTel. +39 045 7514142 - Fax +39 045 [email protected] - www.totaltransfer.it
Scambiatori di calore a piastre
Plate heat exchangers