OperatingManual
Automatic A/C Charging Station
For Refrigerant R-134a Systems Only!
-
8/9/2019 Robinair Mod 10324
2/16
This equipment is intended for professional use only. The service technician should be familiarwith proper servicing of air conditioning systems as well as the dangers and use of refrigerants and
pressurized components before using the equipment.
WARNING Always wear safety goggles when working with refrigerants. Contact with refrigerants can causeinjury.
Connecting hoses to the wrong ports may cause personal injury or may damage the equip-
ment. Check the operating manual for your air conditioning system for the correct hookup.
Disconnect hoses with extreme caution! All hoses may contain liquid refrigerant under pressure.Contact with refrigerant can cause injury. Wear proper, personal protective equipment, including safety
goggles. Point the disconnected end of a hose away from you and anyone who is nearby.
Use only with refrigerant type R-134a! Cross-contamination with other refrigerant types will causesevere damage to the A/C system and to service tools and equipment. Do not mix refrigerant types
through a system or in the same container!
Avoid breathing A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, noseand throat. To remove R-134a from the A/C system, use service equipment certified to meet therequirements of SAE J2210 (R-134a recycling equipment). If accidental system discharge occurs,
ventilate work area before resuming service.
HFC-134a service equipment or vehicle A/C systems should not be pressure tested or leak tested with compressed air. Some mixtures of air/HFC-134a have been shown to be combustible atelevated pressures. These mixtures are potentially dangerous and may result in fire or explosion
causing injury or property damage. Additional health and safety information may be obtained from
refrigerant and lubricant manufacturers.
Improper use or connections may cause electrical shock hazards. Read and follow these
instructions carefully and take all necessary precautions to avoid electrical shock hazards. Before
energizing circuits, be sure that all associated devices are properly grounded. Unplug the station from
the power source before removing the control box.
Safety Precautions
!!
Limited Warranty
This product is warranted to be free from
defects in workmanship, materials, and compo-
nents for a period of one year from date of
purchase. All parts and service center labor
required to repair defective products coveredunder the warranty will be at no charge. The
following restrictions apply:
1. The limited warranty applies to the original
purchaser only.
2. The warranty applies to the product in
normal usage situations only, as described
in the Operating Manual. The product
must also be serviced and maintained as
specified.
3. If the product fails, it will be repaired or
replaced at the option of the manufacturer.
4. Transportation charges for warranty service
will be reimbursed by the factory uponverification of the warranty claim and
submission of a freight bill for normal
ground service. Approval from Robinair
must be obtained prior to shipping to either
an authorized service center or the factory.
5. Warranty service claims are subject to
factory inspection for product defect(s).
6. Robinair shall not be responsible for any
additional costs associated with a product
failure including, but not limited to, loss of
work time, loss of refrigerant, and non-
authorized shipping and/or labor charges.7. All warranty service claims must be made
within the specified warranty period. Proof-
of-purchase date must be supplied to the
manufacturer.
8. Use of Robinair charging equipment with
non-authorized refrigerants will void our
warranty. Authorized refrigerants are listed
on the equipment or are available through
our Technical Service Department.
This Limited Warranty does not apply if:
• The product, or product part, is broken by
accident.
• The product is misused, tampered with, or
modified.
• The product is used for recharging any
substance other than the specified refriger-
ant type.
-
8/9/2019 Robinair Mod 10324
3/161R-134a Smart Cart ® Automatic A/C Charging Station
In troduction ................................................................................................................... 2
Set U p Inst ructions ....................................................................................................... 2
P repar ing the Vacuum P ump .................................................................................. 2
Di agram of Vacuum Pump Components ................................................................. 2
Inst a lling a Refrigera nt Ta nk .................................................................................. 3
Di agram of Disposable Tan k I nstal lat i on ............................................................... 3
Di agram of Refi l lable Tan k In stal l at ion ................................................................. 4
Removing an E mpty Ta nk ........................................................................................ 4
U sing the Hea ter B la nket ........................................................................................ 4
Operat ing Procedures ................................................................................................... 5
Summar y Char t of Operat in g Procedur es ............................................................... 5
To Att a ch Hoses to the S ystem ................................................................................ 5
To Dia gnose Sy stem P roblems ................................................................................. 5
To Add Refrigera nt to P ar tia lly Ch ar ged S ystems .. . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. 5
To Recover Refrigera nt ............................................................................................. 6
To P rogram Vacuum/Ch ar ging C ycle ...................................................................... 6
To Use Automa tic Vacuum /Ch a rging Cycle ............................................................ 6
To Check Fina l Syst em Opera tion ........................................................................... 7To Disconnect t he Sy stem ........................................................................................ 7
Ma intena nce Inst ructions ............................................................................................. 7
St oring the Sta tion .................................................................................................... 7
Ma inta ining th e Vacuum P ump ............................................................................... 7
Checking the Sca le Accura cy ................................................................................... 7
Ca libra ting the Sca le ................................................................................................ 8
U sing Ma nua l Dia gnostics ....................................................................................... 8
Additional Operat ing G uidelines ................................................................................. 9
How to U se the Cont rols ........................................................................................... 9
Di agram of Contr ol Components ............................................................................. 9
U sing t he K eypad ...................................................................................................... 10
Di agram of K eypad ................................................................................................... 10
U sing th e Displa y P a nel ........................................................................................... 10
Qu i ck Refer ence Cha r t .............................................................................................. 11
Di agram of Di splay Panel ........................................................................................ 11
Replacement P a rt s List ................................................................................................. 12
Troubleshooting Tips ..................................................................................................... 13
Temperat ure/P ressure Relation Cha rt ........................................................................ 14
Conversion Cha rt .......................................................................................................... 14
Table of Contents
U.S. Patent Nos.: 4,523,897; 5,005,375; 4,688,388 RE: 33,212
Other U.S. and Foreign Patents Pending
A/C Air conditioning
System The A/C sy st em bein g ser viced
Tank The refrigera nt supply t an k
Station The a utoma tic A/C cha rging sta tion
Glossary of Terms
-
8/9/2019 Robinair Mod 10324
4/162 © 1991 Robinair Division, SPX Corporation
This a utoma tic A/C cha rging st a tion is
designed with you in mind. It is a ccura te,
easy t o program , a nd simple to use.
Be for e us i n g the sta t i on , r ead and
unders tand a l l ins truct ions a nd w arnings
in this operating manual.
The 220V 50Hz m odels ha ve some
operating exceptions, which are noted inthis operating manual.
Introduction In a ddition, all measurements are metrican d the ma nifold is equipped with kP a/
bar ga uges showing tempera ture in
degrees Celsius.
B efore opera ting th e 220V 50Hz m odel,
plug the short pow er cord from t he upper
contr ol box into th e outlet on the lower
power box. Plug the main power cordinto a 220V 50Hz power source tha t is
free of transients and electrical noise.
To set up th e sta tion for opera tion, you
need to prepare the va cuum pump and
install the refrigerant tank.
PREPARING THE VACUUM PUMP
The Va cuMast er® vacuum pump is
shipped with out oil in the reservoir.
Be for e sta r t i ng th e sta t i on , you m us t
f i l l t h e p um p w i t h o i l a n d r emo ve t h e
exhau st p l ug f r om the end o f t he
pum p ’ s han d l e.
Note: The Iso-ValveTM isolation va lve on
th e side of the pump mus t remain open
(the position shown in the illustration)
for t he sta tion to opera te.
CAUTION! D o no t at tempt to run thevacuum pump when the ma nifold gauge
set shows pressure rea dings a bove 5 psi.
In the vacuum mode, positive pressure
will:• High pressure — not a l low the
vacuum solenoids t o open.
• Low pressure — blow oil out of the
pump handle when the va cuum
solenoids do open.
Running t he vacuum pump with posit ive
pressure locks high pressure between the
tw o solenoids a nd prevents operat ion of
the pump.
Follow th ese procedures to prepare t hevacuum pump for use with t he cha rging
sta t ion.
1. Remove an d discar d the exhaust plug
from the end of the pump’s handle.
2. Remove and reta in the black plug on
the oil fill port.
3. P our vacuum pump oil into the oil fill
port until oil appear s in t he sight
glass on th e reservoir. The a pproxi-
ma te oil ca pacity of th e pump is 13
ounces (384 millilit ers).4. Close both t he high side an d low side
valves on t he sta tion’s ma nifold.
Di agram of Vacuum Pump Components
Set Up Instructions
EXHAUST PLUG
OIL FILL PORT
SIGHTGLASS
OILDRAINVALVE
ISO-VALVEˇ
-
8/9/2019 Robinair Mod 10324
5/163R-134a Smart Cart ® Automatic A/C Charging Station
INSTALLING A REFRIGERANT TANK
Follow these steps to insta ll a r efrigerant
tank on the charging station.
WARNING
Always wear safety goggles whenworking with refrigerants. Read and
follow a ll wa rnings at the beginning ofthis ma nua l before operat ing the unit .
Connecting hoses to the wrong portsmay cause personal injury or maydamage the equipment. Read and follow all wa rnings at t he beginning of this
ma nua l before operating the unit .
Use only with refrigerant type R-134a!Cross-conta mina tion w ith other refriger-
an t t ypes will cause severe da ma ge to the
sta tion and t o tools an d equipment.
Do not mix refrigerant types through a
system or in the sa me conta iner!
1. Att ach the sta tion’s yellow charging
hose to a full refrigerant ta nk, as
follows:
• Disposab le ta nks — Connect t he
yellow hose, open the t a nk’s valve,
an d place the inverted tan k (wit h its
valve down) on the scale platform.
B e sure to center th e tan k over the
stud w elding point. U se only ta nks
designed for use w ith R-134a, includ-
ing Acme threa ds on the fit t ings.
5. P lug the sta tion into the proper
voltage outlet , an d tur n on the MAIN
POWER switch.
6. Simulta neously press the ENTER
a nd zero keys on th e keypad to a ccess
the ma nua l diagnostic mode.
7. P ress “1” on the keypad t o star t the
pump.
8. While the pump is running, add
enough va cuum pump oil so tha t t he
oil level is even wit h t he line on t he
reservoir’s sight glass.
9. P ress “1” or the RES ET CYCLE key
on the keypad t o stop th e pump.
10. Replace the black plug on th e oil fill
port .
IMPORTANT! For maximum perfor-ma nce, change th e vacuum pump oil
frequently (approximately after every
four hours of running time). We recom-
mend using our Premium H igh Vacuum
Pump Oil; it is specifically blended to
mainta in ma ximum viscosity a t normal
running t empera tures a nd to improve
cold weather starts (see the “Replace-
ment P ar t s Lis t ”).
Read a nd follow the deta iled instructions
in the Vacu-Master ® Vacuum P ump
Opera ting Ma nua l. You do not need to
return the wa rranty regis tra t ion card
contained in the Vacu-Master ® VacuumPump Operating Manual — return only
the wa rranty regis tra t ion card a t ta ched
to the s ta t ion to va lidate your w arra nty .
Di agram of Di sposable Tan k I nstal lat i on
Set Up Instructions
Bulk Refrigerant Tank(Not Included)
TankValve Handle
Ball
Valve
Yellow Hose ToRefrigerantSolenoid
Dual PurposeHold-Down
Bracket
! !
(Continued)
-
8/9/2019 Robinair Mod 10324
6/164 © 1991 Robinair Division, SPX Corporation
WARNING
Disconnect hoses with extreme caution!All hoses may contain liquid refrigerantunder pressure. Read a nd follow a llwa rnings a t t he beginning of this manual
before operating the unit.
2. Disconnect th e hose from the tank.
3. Release the retaining stra p buckle.
4. Loosen the wing nut on the hold-
down bra cket a nd remove the empty
ta nk from the platform.
USING THE HEATER BLANKET
A heat er blanket speeds the t ra nsfer of
refrigera nt a nd a ssures a complete
charge by raising the pressure with in the
refr igerant ta nk.
1. Wrap the heater blanket a round the
refrigerant ta nk, secure it wit h theVelcro® s tra p, and plug its power cord
into the heater outlet on the bottom
of the control box (right receptacle).
2. Turn on the MAIN P OWER sw itch
on t he front of the sta tion.
The heater blanket is on whenever the
sta tion’s MAIN P OWER switch is on,
elimina ting t he need for ma nua l control.
You can extend the life of the heater
blanket by unplugging the heat er when
it’s not being used or tu rning off th e
MAIN P OWER switch.
• Re f i l l a b l e ta nks — Leave the tank
upright, at tach the yellow charging
hose to the blue LIQUI D va lve on th e
ta nk, an d open the blue valve.
2. Open th e ball valve on the yellow
char ging h ose (th e open position ru ns
par a llel to the hose).
Note: Use a ma ximum ta nk size of 50pounds (23 kilograms) with this charging
sta t ion.
3. Fas ten the tank securely with the
ta nk hold-down bra cket. P lace the
heater bla nket a round the center of
the ta nk, an d fast en it securely (see
“Using the Heater Blanket”).
4. Secure the reta ining s t rap a round
the tank.
Note: Adjust the stra p so that it comes in
contact w ith the ta nk, b u t i s n ot t i g h t a r ou n d t h e t a n k .
5. I f the tank wa s changed a f ter press-
ing the HOLD key to interrupt the
cycle, press the CONT key or RES ET
CYCLE key, depending on the
operation you require next.
REMOVING AN EMPTY TANK
Follow t hese steps to remove an empt y
refrigerant tank from the charging
sta t ion.
1. If the stat ion is opera ting, press theHOLD key. You do not need to turn
off the MAIN POWER switch.
Di agram of Refi l lable Tank I nstal lat i on
PlatformMountRing
Blue LIQUID Valve
Ball Valve
YellowHose To
RefrigerantSolenoid
BulkRefrigerant
Tank(Not Included)
Set Up Instructions
! !
-
8/9/2019 Robinair Mod 10324
7/165R-134a Smart Cart ® Automatic A/C Charging Station
Operating Procedures
Summar y Char t of Operat in g Procedur es
TO DIAGNOSE SYSTEM PROBLEMS
1. Sta r t the A/C sys tem and w atch the
gauge pressures (refer to the
manufacturer’s specifications for
proper opera ting pressures).
2. P er form any other visual and diag-
nostic inspections recommend ed by
the ma nufacturer .
3. If t he A/C sy stem is operat ing prop-
erly, disconnect t he h ose couplers
from the A/C syst em. To recha rge or
ma ke necessary repairs, see the
appropriate sections that follow.
TO ADD REFRIGERANT TO PARTIALLYCHARGED SYSTEMS
1. In t he progra m mode, press ADD .2
lbs. REF RIG . The messa ges “AU TO-
MATIC” an d “RE FRIG ERANT”
appear on the display.
2. Open t he low side valve. The sta tion
dispenses .2 pounds (.1 kilograms) of
refrigeran t, th en displays t he mes-
sage “CP L.” Close the low side valve.
3. Monitor the A/C syst em opera ting
pressures. Correct a ny low cha rge
indicat ions by pressing RE SE T
CYCLE ; repeat S tep 1 as n ecessary.
N ote: There a re oth er A/C s yst em pr ob-
lems which cause symptoms similar t o a
low refrigerant charge — refer to youroperat or’s ma nua l or a relia ble A/C
troubleshooting cha rt . I f a dding one
pound of refrigerant does not correct the
low charge symptoms, you ma y need to
recover a nd/or recharg e refrigeran t, a s
described next.
B efore opera ting th e 220V 50Hz m odel,
plug th e short power cord from t he upper
cont rol box into th e outlet on th e lower
power box. Plug the main power cord
into a 220V 50Hz power source tha t is
free from transients and electrical noise.
The chart below summarizes the steps in
each of th e following sections.TO ATTACH HOSES TO THE SYSTEM
1. Be sure a l l va lves on the manifold are
closed.
WARNING
Connecting hoses to the wrong portsmay cause personal injury or maydamage the equipment. Check your A/Csystem operat ing ma nua l for the correct
hook-up.
Use only with refrigerant type R-134a!Cross-conta mina tion w ith other refriger-
an t t ypes will cause severe da ma ge to the
sta tion and t o tools an d equipment.
Do not mix refrigerant types through a
system or in the sa me conta iner!
2. Att ach th e red high side hose’s
coupler to t he h igh side of t he A/C
system.
3. Att ach t he blue low side hose’s
coupler to t he low side of t he A/C
system.
N ote: The ma nifold is ported so tha t t hegauges indicate pressure wh ether or not
the valves are open.
! !
SUMMARY
1. Attach hoses to the A/C system.
2. Start the A/C system and compare operating pressures to
manufacturer’s specifications.
3. Add a partial charge, if necessary.
4. Discharge the A/C system, if required.
5. Program the vacuum/recharge cycles.
6. Start the A/C system and perform final operating check.
7. Disconnect the hoses from the A/C system.
-
8/9/2019 Robinair Mod 10324
8/166 © 1991 Robinair Division, SPX Corporation
TO RECOVER REFRIGERANT
IMPORTANT! U se a recovery unit . Dono t vent refrigera nt t o the at mosphere.
1. B e sure the A/C syst em is turn ed off,
then connect t he yellow hose from
the m a nifold’s center port to your
recovery un it’s inlet port.
2. Open th e manifold’s red high side
valve, blue low side valve, and center
valve, and sta rt t he recovery unit .
Follow the recovery unit’s instruc-
tions to recover refrigerant.
TO PROGRAM VACUUM/ CHARGING CYCLE
Vacuum is programmed in minutes a nd
refrigera nt is programmed by w eight. If
no quant ity for an y particular cat egory is
required, enter zeros.
1. I f the message “PROGRAM” is not
displayed, press RES ET CYCLE.
2. The message “VACU UM” should
appear on the display. If it does not,
press the RE VIEW PROG RAM key
repeatedly until it does.
Note: Follow the A/C sys tem m a nufa ctur-
er’s recommenda tions for t he proper
vacuum and refrigerant requirements.
3. P ress the appropriate number keys
until the desired vacuum t ime
appears on the display. E ntervacuum time in w hole minutes.
For example, to program 20 minutes,
press two and zero — the display
shows “20.00.” P ress ENTER an d th e
display flashes once indicat ing t he
progra mmed da ta is accepted.
4. P ress the REVIEW P ROGRAM key.
The message “REFRIGERANT”
appears on the display. Ent er the
am ount of refrigerant to be recha rged
to hundredths of a pound.
For example, to program 23/4 pounds,
press two, seven, five and ENTER.
The display sh ows “2.75” a nd fla shes
once, indicating the programmed
data is accepted. To program 21/2
pounds, press t wo, five, zero a nd
ENTER — be sure to add t he last
zero.
Note: U se th e convenient conversion
chart on t he back cover of this ma nua l if
you need help convertin g ounces to
hundredths of a pound.
TO USE AUTOMATIC VACUUM/ CHARGING CYCLE
IMPORTANT! Before start ing the
va cuum pump, be sur e tha t a ll A/Csystem pressure is discharged.
1. Close the SYSTEM D ISCH ARGE
valve, and open the appropriat e high
side a nd/or low side va lves on th e
station.
2. P ress the START key on t he keypad.
The display shows the message
“AUTOMATIC” followed by the
message “VACU UM.”
3. After a s l ight delay the vacuum
pump start s . The display shows theam ount of t ime program med and
begins a countdown to zero.
4. At the end of the automa tic vacuum
cycle, the display shows the message
“HOLD.” C lose the high and low side
valves a nd m a ke sure the A/C syst em
holds a vacuum (if it doesn’t, perform
a ny n ecessa ry r epairs). Then open
the high a nd low side valves, and
press CONT to cont inue cha rging.
Note: Consu lt y our A/C sy st em service
guide for the proper chargingprocedure.
5. During the cha rging cycle, the
message “REFRI G ERANT” appears
on the display. The display shows the
progra mmed a mount of refrigeran t,
counts d own to zero as the char ging
process proceeds, a nd indica tes t he
end of the char ging process by
showing the message “CP L.”
6. If the refrigerant t ran sfer is too slow,
the sta tion emits an a udible signal,
the display countdown st ops, and the
message “CHE CK REFRIG ERANT”
appears on the display. P ress the
HOLD key and close the high side
valve, but leave the low side valve
open. St a rt t he A/C syst em, a nd press
the C ONT key to pull the rema inder
of the cha rge into th e low sid e of the
A/C sy st em.
Operating Procedures
-
8/9/2019 Robinair Mod 10324
9/167R-134a Smart Cart ® Automatic A/C Charging Station
2. Compare the gauge pressure read-
ings to the system ma nufacturer’s
specifications.
3. Check the cool air vent discharge
temperature to be sure that the
syst em cooling is a cceptable.
TO DISCONNECT THE SYSTEM
1. Turn off the A/C syst em.
WARNING
Disconnect hoses with extreme caution!All hoses may contain liquid refrigerantunder pressure. Read a nd follow a llwa rnings a t t he beginning of this manual
before operating the unit.
2. Disconnect the blue an d red hose
couplers from t he A/C s yst em.
3. Replace the caps on all fit t ings. Store
the hoses on the cart , a nd store thecouplers by connecting t hem t o the
coupler ra ck.
!
If the signal continues and t he
display does not count down, press
the HOLD key an d replace the tank
as described in “Insta lling a Refriger-
an t Tan k.” P ress the CONT key to
complete th e au toma tic cycle, or
press RESET to access the program
mode.
7. When th e aut omatic cycle is com-
pleted, the sta tion beeps once, an d
the message “CPL” appears on the
display , followed by the “H OLD”
message. Pr ess any key to a ccess the
program mode.
TO CHECK FINAL SYSTEM OPERATION
B efore disconn ecting t he A/C sy st em
from the sta tion, you should check tha t it
is operating properly.
CAUTION! B efore st a rt ing t he A/Csystem, be sure both valves on the
station’s manifold are closed.
1. Run th e A/C system unt il the gauge
readings sta bilize.
Operating Procedures
!
Follow t hese instru ctions to properly
ma inta in your a utomat ic A/C charging
sta tion. Be sure to wipe up any spills
immediately a nd keep the sta tion clean.
STORING THE STATION1. Turn off the MAIN P OWER switch,
and unplug the station.
2. St ore the hoses on the car t , an d store
the couplers by connecting them to
the coupler rack.
3. Close all valves when the sta tion is
not in use.
MAINTAINING THE VACUUM PUMP
1. Check the vacuum pump oil daily,
a nd a dd oil as necessary. The proper
level is at the midpoint of the sight
glass w hen the vacuum pump is
runn ing a nd t he A/C syst em is under
vacuum.
N ote: Use only our P remium High
Vacuum P ump Oil (see “Repla cement
P ar ts Lis t ”).
2. For maximum efficiency a nd longer
pump life, change the vacuum pump
oil frequently (approximately after
every four hours of running time).
Read a nd follow the deta iled instructionsin the vacuum pump operat ing man ual
to chan ge oil.
CHECKING THE SCALE ACCURACY
You should routinely check the accuracy
of the scale platform a nd calibrat e the
scale, if necessary, to assure th at the unit
charges accurately.
1. While in the P ROGRAM mode,
simultan eously press the E NTER an d
zero keys on the keypa d to clea r th e
display.
2. P ress the “6” key on the keypad to
display the a pproximate scale
platform weight.
3. Remove the ta nk from the scale
platform. The empty platform weight
display ed should range from + tw o
pounds. If it does not, contact the
factory.
Maintenance Instructions
-
8/9/2019 Robinair Mod 10324
10/168 © 1991 Robinair Division, SPX Corporation
USING MANUAL DIAGNOSTICS
The s ta t ion has internal and m anua l
dia gnostic modes. The int erna l or self-
dia gnostic mode checks for entr ies or
pressures outside of normal limits and
for cert a in electrical conditions. The
ma nua l diagnostic mode allows you to
check major components for properoperation.
The station’s safety features include a
check valve which prevents high side
pressure from entering t he refrigera nt
tank. Also, any operating problems
resulting in an error message on the
display prevent opera tion until th e
problem is corrected.
WARNING
Be sure to discharge any system pres-sure before performing any manualdiagnostics.
1. I f the message “PROGRAM” is not
displayed, press the RES ET CYCLE
key.
2. Simulta neously press the ENTER
a nd zero keys. The display should be
blan k except for the decimal point.
3. P ress the following keys to perform
these functions:
Pr ess “1” — The VACU U M displa y
segment comes on, the vacuumsolenoid opens, and the pump starts.
P ress “1” aga in to turn off.
Pr ess “3” — The REF RIG ERANT
display segment comes on and the
solenoid opens. This is a momenta ry
conta ct switch w hich turns off when
released. C lose the high an d low side
valves to perform this test.
Pr ess “5” — All display segments
light up. Pr ess “5” a gain t o turn off.
Pr ess “6” — The display shows t he
approximat e weight on t he scale. See
“Checking the Scale Accuracy” for
dia gnostic procedures.
4. P ress the RESET CYCLE key to
return t o the program mode.
CALIBRATING THE SCALE
You should also routinely calibrate the
scale, if necessary, to a ssure that the
compressor shuts off when t he ta nk is
full. You can a utomat ically calibrat e the
scale through the keypad.
WARNING
Proper operation of the scale is essen-tial to safety features built into thestation. If you have any questions aboutscale accuracy, call the factory.
1. P ress ENTER a nd the zero key on
the keypad to access the diagnostic
mode, then press 8-7-8-7. The display
will sh ow “A1.”
Note: If you press a ny other key before
the 8-7-8-7 sequence, you cannot enter
the a utomat ic calibration routine.
2. B e sure the scale is empty of all
weight (e.g. ta nk). P ress “0” a nd t hen
press ENTER on the keypa d. The
display shows “0.00” and then
chan ges to the messa ge “A2.”
3. P lace a known weight (between 10
a nd 80 pounds) in th e cent er of the
scale platform. Enter tha t w eight on
the display using the keypad, t hen
press ENTER . The display r eturn s to
the VACU UM mode.
4. To re-enter th e diagnostics mode a ndverify t he calibrat ion, simulta neously
press ENTER and the zero key on the
keypad. Then press “6.” The display
shows the known w eight on th e scale
platform.
5. Remove the known weight , and the
display r eturn s to “0.00.”
Maintenance Instructions
! !
! !
-
8/9/2019 Robinair Mod 10324
11/169R-134a Smart Cart ® Automatic A/C Charging Station
HOW TO USE THE CONTROLS
The charging station has various compo-
nents t ha t control its opera ting func-
tions.
CAUTION! D o no t operate t he stat ionuntil you ha ve filled the vacuum pump
wit h oil and removed th e exha ust plug
from the pump’s handle, as outlined in“Preparing the Vacuum Pump.”
1. SYSTEM DISCHARGE Valve — Letsyou depressu rize t he A/C sy st em.
Connect to a refrigerant recovery
unit — do no t vent refrigerant t o the
atmosphere.
2. LOW Side Valve — When closed,isolat es th e low sid e of the A/C
system from t he sta tion controls.
N ote: The ma nifold is ported so tha t t he
gauges indicate pressure wh ether or notthe valves are open.
3. LOW Side Compound Gauge — Whenconnected t o the low side of a n A/C
system, indicates the system’s low
side pressure.
4. HIGH Si de Va lve — When closed,isolat es th e high side of th e A/C
system from t he sta tion controls.
5. HIGH Side P ressure Ga uge — Whenconnected t o the h igh side of a n A/C
system, indicates t he system’s highside pressure.
6. Display — Shows the t ime pro-
gram med for vacuum, the w eight of
refrigeran t programm ed for charg-
ing, the control sta tus, a nd t he cycle
of operation. Detailed instructions for
program ming th e display follow the
next section.
7. Keypa d — Accomplishes specific
operating functions, as described in
the next section.
8. MAIN POWER Switch — Supplieselectrica l power t o the cont rol panel.
9. ACCESSORY Outlet — Pr ovides anelectrica l outlet for a ccessory equip-
ment, such as a thermistor vacuum
ga uge. This outlet is energized w hen
the sta tion is plugged in, an d it is
loca ted on t he side of the control box.
N ote: There is no accessory outlet on the
220V 50Hz m odel.10. HEATER Outlet — Provides a n
electrical outlet for the refrigerant
tank’s heater blanket. This outlet is
contr olled by th e MAIN P OWER
switch a nd is energized when the
pow er is on.
11. PUMP Outlet — Provides an electri-cal outlet for th e vacuum pum p. This
outlet is controlled by t he logic board.
Additional Operating Guidelines
Di agram of Contr ol Components
-
8/9/2019 Robinair Mod 10324
12/1610 © 1991 Robinair Division, SPX Corporation
Additional Operating
Guidelines
USING THE KEYPAD
The cha rging sta tion also has a unique
keypad for da ta entry. It uses only six
keys for sequence control, and the LCD
display indicat es the opera ting m ode.
CAUTION! Do no t operate t he sta tionuntil you ha ve filled th e vacuum pump
with oil an d removed th e exha ust plugfrom the pump’s handle, as outlined in
“Preparing the Vacuum Pump.”
START — P ress to begin the a utomat iccycle after t he charging st at ion is pro-
grammed.
CONT — Pr ess to resume (or cont inue)operations a fter pressing the H OLD key
(described below).
HOLD — P ress to interrupt t heaut oma tic cycle.
REVIEW PROGRAM — P ress to review the existing programmed data.
ENTER — P ress to enter program da tainto t he computer’s memory.
RESET CYCLE — Press t o accessprogram mode.
ADD .2 LB. REFRIG. — P ress to partia llycha rge t he A/C sy st em.
USING THE DISPLAY PANEL
The charging sta tion a lso displays
various messages on the display pa nel.
CAUTION! Do no t operate t he sta tionuntil you ha ve filled th e vacuum pump
with oil an d removed th e exha ust plug
from the pump’s handle, as outlined in
“Preparing the Vacuum Pump.”
Segment A — Indicat es in wh ich modethe sta tion is operating:
PROGRAM — The sta tion is in t heprogra mming m ode, which a llows
you to program va cuum time and
refrigerant weight or to review th e
existing program.
HOLD — The evacuation process iscomplete a nd t he vacuum pump is
off, or no refrigerant is being
charged; also HOLD is used whilechanging a refr igerant ta nk or to
interr upt t he vacuum /char ging
cycles.
AUTOMATIC — Eith er the vacuumor refrigerant charging cycle is in
process.
Segment B — Indicates th e stat ion iseither eva cuat ing t he A/C sy stem or
charging refrigerant or the sta tion is
rea dy t o be program med for one of these
tw o functions:
VACUUM
• Wi t h PR O GR AM, ind ica t e s t h e
sta tion is ready t o be programmed for
evacuation.
• With AUTOMATIC, indicates the
vacuum pump is running; the num-
ber displayed counts down in sec-
onds, showing the a mount of t ime
remaining for evacuat ion.
• With HOLD, indica tes the vacuum
cycle is complete (if t he displa y sh ows
“0.00”), or if you pressed the H OLD
key to interrupt the vacuum cycle,
indicat es the rema ining t ime the
pump runs when you press the
CONT key.
Di agram of K eypad
-
8/9/2019 Robinair Mod 10324
13/1611R-134a Smart Cart ® Automatic A/C Charging Station
Qu i ck Refer ence Cha r t
Segment B Messages
VACUUM + PROGRAM = Program station for vacuumVACUUM + AUTOMATIC = Vacuum pump is runningVACUUM + HOLD = Evacuation complete or
interrupted vacuum cycle
REFRIGERANT + PROGRAM = Program station for chargeREFRIGERANT + AUTOMATIC = Station is charging A/C systemREFRIGERANT + HOLD = Interrupted charging cycle
REFRIGERANT (POUNDS)
• Wi t h PR O GR AM, ind ica t e s t h e
sta tion is ready to be programmed
for t he am ount of refrigera nt to be
char ged int o the A/C system ;
on the keypad enter th e charge in
pounds (or kilogram s, depending on
th e model you ha ve).
• With AUTOMATIC, indicat es the
sta tion is charging refrigerant into
th e A/C sy stem; t he num ber shown
on the display counts down, showing
the remaining a mount of refrigerant
to be dispensed.
• With HOLD, indica tes the HOLD key
wa s pressed to interrupt the charging
cycle; the number shown on the
display is the a mount of refrigerantremaining t o be charged into the
syst em. To cont inue cha rging, press
CONT.
Use the quick reference chart above to
interpret Segment B messages.
Segment C — Shows a number or acoded error m essage on the display tha t
indicat es the sta tion’s operating sta tus or
a ny specific problems.
NUMBER
Indicates the vacuum time in min-
utes or the refrigerant weight in
pounds (or kilogram s, depending on
th e model you ha ve).
MESSAGE CODES
• C PL — I n dica t e s t h e r ef ri ger a n t
char ging cycle is complete.
• ERR5 — Indica tes an over loaded or
broken scale.
Segment D — Indicat es the tra nsfer ofrefrigerant is slow or has stopped.
• I f th e d i sposab l e ta nk i s emp ty or
t h e r ef i l l a b l e t an k i s l ow , replace
the t an k following the instr uctions in
“Insta lling a Refrigerant Tan k.” A
small amount of refr igerant a lwaysremains in a refillable ta nk.
• I f t h e r e i s adequa t e r ef r i g er an t i n
t h e t a n k , you need to pull the
remainder of the program med charge
int o the low si de of the A/C sy st em,
a s outlined in S tep 7 of “To Use
Automa tic Vacuum /Cha rging Cycles.”
Additional Operating Guidelines
Di agram of Di splay Panel
-
8/9/2019 Robinair Mod 10324
14/1612 © 1991 Robinair Division, SPX Corporation
Replacement Parts List
The followin g is a list of replacement
part s you ma y need to service or ma in-
tain your automatic charging station.
Because of ongoing product improvements, we
reserve the right to change design, specifications,
or materials without notice.
Our P remium High Vacuum P ump Oil is
also available in handy quart containers
or in convenient gallon containers:
Qua rt (shipped 12 qua rt s per case) 13203
G a llon (shipped 4 gallons per case) 13204
This oil ha s been specifically blended t o
mainta in ma ximum viscosity and to
improve cold w eather st ar ts .
Description 115V 60 Hz 220V 50 Hz
Handle (Red) 40448 40448
Handle (Blue) 40447 40447
Gauge, Blue Low Side Compound 11741 11726
Gauge, Red High Side Pressure 11742 11727
High Side Coupler 18191 18191
Low Side Coupler 18190 18190
Vacuum Pump RA15427 RA15428120” Blue Hose 62120 62120
120” Red Hose 63120 63120
60” Yellow Hose 37160 37160
9” Blue Hose 37059 37059
Tank Hose 37024 37024
Black Vacuum Hose 40586 40586
Main Power Switch RA40994 RA40994
Scale Assembly RA19008 RA19008
Tank Platform RA14967 RA14967
Heater Blanket 10994 45605
Vacuum Solenoid Assembly RA19020 RA19020
Refrigerant Solenoid RA19006 RA19006
Main Board RA18761 RA19092
Keypad RA18751 RA18751
Check Valve RA17112 RA17112
Tank Strap RA19056 RA19056
Cover 17495 17495
Wheel & Nut RA10751 RA10751
Transformer N/A RA19091
High Vacuum Grease 13033 13033
-
8/9/2019 Robinair Mod 10324
15/1613R-134a Smart Cart ® Automatic A/C Charging Station
Symptom Cause Cure
• Station unplugged • Plug station into power
source
• No power at wall outlet • Locate problem with outlet or
change outlets
• Vacuum pump unplugged • Plug pump into power source
• Vacuum time not entered • Program required vacuum
time
• Defective vacuum pump • Remove and replace pump
• Faulty components • Call factory
• Transfer stopped or • Start A/C system and pulltoo slow rest of refrigerant into system
(Step 6 in “To Use Automatic
Vacuum/Charge Cycle”)
• Tank safety strap too tight • Loosen the safety strap
• Refrigerant supply empty • Replace the refrigerant tankor call factory
• Refrigerant supply empty • Replace the refrigerant tank
• Discharge valve open • Close discharge valve
• Low side valve closed • Open low side valve
• Pump oil contaminated • Flush and change pump oil
• Hose gasket damaged • Replace gasket or hose
• Charging line loose • Check connections
• Manifold leaking • Check connections
• Pump’s Iso-valve closed • Open Iso-valve
• Overloaded or broken • Check tank weight, recali-
scale brate if necessary, or callfactory
Trouble- Shooting Tips
No power when
POWER switch is on — no display showing
Vacuum pump does not start
Audible tone sounds and “ CHECK REFRIG- ERANT ” message
displays during refrigerant transfer
Refrigerant doesn ’ t flow
or “ REFRIGERANT ” message doesn ’ t
display
Vacuum pump runs, but
low side gauge does not register an appropriate
vacuum
ERR5
-
8/9/2019 Robinair Mod 10324
16/16
For assistance in servicing or using theAutomatic A/C Charging Station, call thetoll-free Service Line, 800-822-5561, inside
the continental U.S. In Canada, call 419-485-5561, Ext. 300. In all other locations,contact your local distributor. To help usserve you better, please be prepared toprovide the model number, serial number,and date of purchase.
To validate your warranty, you must com-plete the warranty card attached to yourstation and return it within ten days fromdate of purchase.
Ounce Pound
1 .062 .123 .19
4 .255 .31
6 .387 .44
8 .509 .5610 .62
11 .6912 .75
13 .81
14 .8815 .9416 1.00
PSI(oF) R-34a
-20 -1.8-15 0
-10 2.0-5 4.1
0 6.55 9.1
10 12.0
15 15.120 18.4
25 22.130 26.1
35 30.4
40 35.045 40.1
50 45.455 51.3
60 57.465 64.0
70 71.175 78.580 86.7
85 95.390 104.3
95 113.9100 124.1
105 134.9110 146.3
115 158.4120 171.1125 184.5
130 198.7135 213.5
140 229.2
Note : Gauge pressures are approximationsrounded to the nearest 1/20 PSI.
Temperature — Pressure RelationR-134a Refrigerant
Conversion ChartOunces to Hundredths of a Pound