Overview Features Specifications - The Lighting Quotient specifications supersede all prior...

20
Certain products illustrated may be covered by applicable patents and patents pend- ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved. 114 Boston Post Road, West Haven, Connecticut 06516, USA Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com ® solar panel (1 of 6) PIR sensor lens TOP 4.8" (122mm) 4.37" (111mm) 1.4" (36mm) SIDE LINK button Antenna 2.05" (52mm) 1.41" (36mm) BOTTOM VIEW CMS-EN-03, CMS-EN-04 Wireless Occupancy Sensors The CMS-EN-03/04 wireless, battery free occupancy sensors generate their own power using six integral photovoltaic cells that harvest energy from the ambient light in the space. They operate in low light conditions and will remain charged for over 90 hours in no light (for auto-ON occupancy response in areas with extended no-light conditions, CMS-EN-03/04 sensors accept a field installable #CR2032 battery). CMS-EN-03/04 sensors use passive infrared detection circuitry and wireless transmission to send occupancy signals to linked CLC Series load controllers and CCH control hubs within range. When occupancy signals cease, the load controllers and hubs respond by dimming and/or switching their loads OFF after a preset auto-OFF time delay. CMS-EN-03/04 sensors also double as commissioning tools for adjusting the auto-OFF time delay of each linked controller. CMS-EN occupancy sensors require no hardwired electrical connections, greatly simplifying the installation and commissioning process. The devices can be easily moved or repositioned as field conditions or changes in the space necessitate, ensuring maximum flexibility now and in the future. To order: CMS-EN-03-WH-0 Wireless occupancy sensor, large motion CMS-EN-04-WH-0 Wireless occupancy sensor, small motion Specifications Overview Features Self powered – no wiring or batteries needed. Simple installation – no special tools or hardware required. Reconfigurable – easily repositioned as space or furniture layouts change. Smart – embedded walk-test firmware ensures optimal sensor placement and easily adjustable time-out settings for uncomplicated commissioning. Maintenance free – no batteries to replace or electrical wires to service. Flexible – designed for open plan offices, private offices, and similar spaces. Programmable – easy commissioning: manual through LINK button or via optional software. Sustainable – no electrical power, wiring, batteries or maintenance; reconfigurable; long product life delivers significant savings for many years to come. Power supply: Integral solar cells. Initial charge operation: 60 seconds at 3 footcandles (30 lux). Operational light level: 3 footcandles (30 lux) minimum. Charging time period: 6 hours at 20 footcandles (200 lux). Full charge operation: Minimum 90 hours. Communications: 902 MHz EnOcean® radio. Transmission range: 75ft indoor (23m). Transmission interval: 100 seconds or on motion. Mounting height: 8 to 10 feet. Mounting: Surface mount via double-sided tape or screws by others. Optimal operating temperature: 32°F to 90°F (0°C to 32°C). Relative humidity: 5% to 95% RH (non-condensing). Weight: 3.7 oz. (104 grams). Dimensions: 4.8" x 4.37" x 1.4"D (122mm x 111mm x 36mmD). Agency listing: FCC, IC. Warranty: 2 years. 3/16 Dimensions CO 1.0

Transcript of Overview Features Specifications - The Lighting Quotient specifications supersede all prior...

Page 1: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

solar panel(1 of 6)

PIRsensor lens

TOP

4.8" (122mm)

4.37"(111mm)

1.4"(36mm)

SIDE

LINKbutton

Antenna

2.05"(52mm)

1.41"(36mm)

BOTTOM VIEW

CMS-EN-03, CMS-EN-04 Wireless Occupancy Sensors

The CMS-EN-03/04 wireless, battery free occupancy sensors generate their own power using six integral photovoltaic cells that harvest energy from the ambient light in the space. They operate in low light conditions and will remain charged for over 90 hours in no light (for auto-ON occupancy response in areas with extended no-light conditions, CMS-EN-03/04 sensors accept a field installable #CR2032 battery). CMS-EN-03/04 sensors use passive infrared detection circuitry and wireless transmission to send occupancy signals to linked CLC Series load controllers and CCH control hubs within range. When occupancy signals cease, the load controllers and hubs respond by dimming and/or switching their loads OFF after a preset auto-OFF time delay. CMS-EN-03/04 sensors also double as commissioning tools for adjusting the auto-OFF time delay of each linked controller.CMS-EN occupancy sensors require no hardwired electrical connections, greatly simplifying the installation and commissioning process. The devices can be easily moved or repositioned as field conditions or changes in the space necessitate, ensuring maximum flexibility now and in the future.

To order:

CMS-EN-03-WH-0 Wireless occupancy sensor, large motion

CMS-EN-04-WH-0 Wireless occupancy sensor, small motion

Specifications Overview Features Self powered – no wiring or batteries needed. Simple installation – no special tools or hardware required. Reconfigurable – easily repositioned as space or furniture

layouts change. Smart – embedded walk-test firmware ensures optimal

sensor placement and easily adjustable time-out settings for uncomplicated commissioning.

Maintenance free – no batteries to replace or electrical wires to service.

Flexible – designed for open plan offices, private offices, and similar spaces.

Programmable – easy commissioning: manual through LINK button or via optional software.

Sustainable – no electrical power, wiring, batteries or maintenance; reconfigurable; long product life delivers significant savings for many years to come.

Power supply: Integral solar cells.Initial charge operation: 60 seconds at 3 footcandles (30 lux).Operational light level: 3 footcandles (30 lux) minimum.Charging time period: 6 hours at 20 footcandles (200 lux).Full charge operation: Minimum 90 hours.Communications: 902 MHz EnOcean® radio.Transmission range: 75ft indoor (23m).Transmission interval: 100 seconds or on motion.Mounting height: 8 to 10 feet.Mounting: Surface mount via double-sided tape or screws by others.Optimal operating temperature: 32°F to 90°F (0°C to 32°C).Relative humidity: 5% to 95% RH (non-condensing).Weight: 3.7 oz. (104 grams).Dimensions: 4.8" x 4.37" x 1.4"D (122mm x 111mm x 36mmD).Agency listing: FCC, IC.Warranty: 2 years.

3/16

Dimensions

CO1.0

Page 2: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

CO1.1

CMS-EN-03, CMS-EN-04

Compatible Devices

Wireless Load ControllerCLC-EN-0620A 120/277V wirelessswitching controller CLC-EN-1120A 120/277V wirelessswitch/dim controllerwith 0-10V dimming

Wireless Control HubCCH-EN-03Auto-ON/auto-OFF hub, dimming disabled

Furniture CircuitSwitching InterfaceCFC-RJ-018-wire, 4 circuit, 120V

Typical ApplicationNote: Devices pictured are not precisely in scale to each other.

3/16

Use CMS-EN-03 and CMS-EN-04 for auto-ON/auto-OFF control of office lighting and plug loads. Add optional battery-free wireless wall switch for manual-ON/auto-OFF and manual-OFF lighting control. Substitute wireless load controller CLC-EN-11 in place of CLC-EN-06 to add manual dimming of office lighting.

CMS-EN-04

Wireless Load Controller CLC-EN-06

CMS-EN-03CMS-EN-04

Wireless Control Hub CCH-EN-03

Unswitched

Switched

Optional battery-freeWireless Wall SwitchCWS-EN-03, CWS-EN-04

Furniture Circuit SwitchingInterface CFC-RJ-01

Detection Coverage

CMS-EN-03 (with large motion lens)CMS-EN-04 (with small motion lens)

7 ft.

2.5 ft.

18 ft. (5.5m) Ø52 ft. (15.8m) Ø

Largemotion

Mediummotion

Largemotion

7 ft.

2.5 ft.

12 ft. (3.7m) Ø20 ft. (6.1m) Ø40 ft. (12.2m) Ø

Largemotion

Mediummotion

Smallmotion

Mediummotion

Largemotion

Page 3: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

CLS-EN-02 Wireless Daylight Sensor

The CLS-EN-02 daylight sensor is a battery free, wireless device that harvests solar energy via two integral photovoltaic cells to generate its own power. The sensor easily operates in low light conditions and requires no hardwired electrical connection – simplifying both installation and commissioning. It can be easily moved or repositioned as field conditions or changes in the space necessitate, ensuring maximum flexibility now and in the future.

In combination with The Lighting Quotient controllers, including CLC dimming controllers and CCH hubs, the CLS-EN-02 daylight sensor delivers a straightforward and effective daylight harvesting solution. The sensor monitors interior light levels and wirelessly transmits light level signals to any number of controllers within range as daylight is detected. In turn, each controller automatically switches or dims lights based on its configurable set point. The CLS-EN-02 sensor also doubles as a commissioning tool for adjusting the set point of each linked controller.

To order:

CLS-EN-02-WH-0 Wireless daylight sensor

Specifications Overview Features Self powered – no wiring or batteries needed. Simple installation – no special tools or hardware required. Reconfigurable – easily repositioned as space or furniture

layouts change. Smart – embedded firmware ensures accurate light level

feedback to daylight harvesting controllers and simplified commissioning.

Maintenance free – no batteries to replace or electrical wires to service.

Flexible – designed for open plan offices, private offices, and similar spaces.

Sustainable – no electrical power, wiring, batteries or maintenance; reconfigurable; long product life delivers significant savings for many years to come.

Power supply: Integral solar cell.Initial charge operation: 5 minutes at 4 footcandles (40 lux).Operational light level: 4 footcandles (40 lux) minimum.Charging time: 6 hours at 20 footcandles (200 lux).Full charge operation: 24 hours.Communications: 902 MHz EnOcean® radio.Sensitivity range: 1-100 footcandles.Transmission range: 75ft indoor (23m).Transmission interval: 10-110 seconds depending on light and charge level.Mounting: Surface mount via double-sided tape or screws by others.Operating temperature: –13°F to 145°F (–25°C to 65°C).Relative humidity: 5% to 95% RH (non-condensing).Weight: 2.6 oz. (74 grams).Dimensions: 3.94" diameter x 0.94" height (100mm x 24mm).Agency listing: FCC, IC.Warranty: 2 years.

10/15

Dimensions

CO2.0

∅ 3.94"(100mm)

0.94"(24mm)

LINKbutton

TOP

SIDE

Antenna(under cover)

∅ 2.37"(60mm)

BOTTOM VIEW

Page 4: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

Compatible DevicesNote: Devices pictured are not precisely in scale to each other.

CO2.1

10/15

Wireless Load ControllerCLC-EN-0620A 120/277V wirelessswitching controller CLC-EN-1120A 120/277V wirelessswitch/dim controllerwith 0-10V dimming

Wireless Control HubCCH-EN-02Manual-ON/auto-OFF hub with auxiliary dimming output

Typical ApplicationUse CLS-EN-02 to report daylight conditions to CLC-EN-11 wireless dimming controllers and CCH-EN-02 wireless control hubs for automatic daylight response dimming of hardwired lighting and portable tambient luminaires installed in proximity to exterior windows and skylights. For daylight response switching of non-dimming luminaires, use CLS-EN-02 with CLC-EN-06 wireless switching controllers.

CLS-EN-02

Wireless Load Controller CLC-EN-11

Wireless Control Hub CCH-EN-02

CLS-EN-02

Page 5: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

CWS-EN-03, CWS-EN-04 Wireless Wall Switches

The CWS-EN-03/-04 is a self-powered, battery-free, wireless switch that transmits radio signals to one or more Lighting Quotient controllers for switching lighting and other electrical loads. CWS wireless switches do not require batteries, as the simple act of pressing the rocker generates enough energy to transmit a wireless command.

Available in both single and dual rocker configurations, the CWS wireless switch mounts directly to most surfaces or to any standard switch box. More than one CWS switch can be used to control loads from multiple locations within a space. When used in conjunction with The Lighting Quotient dimming controllers, the CWS switch acts as a multi-location wall box dimmer. Combined with other wireless control products from The Lighting Quotient, the CWS switch delivers simple and maintenance free control of lighting and other electrical loads for both new construction and retrofit projects.

To order:

CWS-EN-03-WH-0 Wireless single rocker wall switch, white

CWS-EN-04-WH-0 Wireless dual rocker wall switch, whiteCWS wireless switches are also available in ivory and black finishes on special request. Minimum quantities apply. Contact factory for details.

Specifications Overview Features Self powered – no wiring or batteries needed. Simple installation – no special tools or hardware required. Reconfigurable – easily repositioned as space or furniture

layouts change. Smart – unique radio ID ensures that each switch controls

only the electrical load or lighting zone to which it has been associated.

Maintenance free – no batteries to replace or electrical wires to service.

Flexible – designed for open plan offices, private offices, and similar spaces.

Sustainable – no electrical power, wiring, batteries or maintenance; reconfigurable; long product life delivers significant savings for many years to come.

Power supply: Electrodynamic energy harvester.

Operating mode: On/off toggle; press and hold dimming.

Communications: 902 MHz EnOcean® radio.

Transmission range: 75ft indoor (23m).

Installation: Mounting frame surface mounts to most surfaces via double-sided tape or screws by others. Switch module fits standard wall boxes. Single-gang faceplate included.

Life cycle/actuations: 50,000.

Operating temperature: –13°F to 145°F (–25°C to 65°C).

Relative humidity: 5% to 95% RH (non-condensing).

Weight: 3.4 oz. (96.4 grams).

Dimensions with faceplate: 4.53"H x 2.8"W x 0.8"D (115mmH x 71mmW x 20mmD).

Agency listing: FCC, IC.

Warranty: 2 years.

CWS-EN-03CWS-EN-03 CWS-EN-04CWS-EN-04

3/16

Dimensions

CO3.0

FRONT SIDE

2.8" (71mm)

0.8"(20mm)

4.53"(115mm)

TOP

3.28"(83mm)

mounts tostandardwall box

SWITCH MODULE(front)

MOUNTING FRAME(front)

2.0"(51mm)

3.67"(93mm)

Page 6: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

Compatible DevicesNote: Devices pictured are not precisely in scale to each other.

CO3.1

3/16

Wireless Load ControllerCLC-EN-0620A 120/277V wirelessswitching controller CLC-EN-1120A 120/277V wirelessswitch/dim controllerwith 0-10V dimming

Wireless Control HubCCH-EN-02Manual-ON/auto-OFF hub with auxiliary dimming outputCCH-EN-03Auto-ON/auto-OFF hub,dimming disabled

Furniture CircuitSwitching InterfaceCFC-RJ-018-wire, 4 circuit, 120V

Typical ApplicationUse CWS-EN-03 and CWS-EN-04 wireless, battery-free switches with CLC-EN-11 and CCH-EN-02 controllers for manual switching and dimming of office lighting. Add CLC-EN-06 Wireless Load Controllers and CFC-RJ-01 Furniture Circuit Switching Interfaces to turn certain office plug loads ON when lights are ON and OFF when lights are OFF.

Wireless Load Controller CLC-EN-11

Wireless Control Hub CCH-EN-02

CWS-EN-03, CWS-EN-04

Wireless Load Controller CLC-EN-06

Unswitched

SwitchedFurniture Circuit SwitchingInterface CFC-RJ-01

CWS-EN-03 orCWS-EN-04

Page 7: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

CPP-EN-02Wireless Transmitting Power Pack

The CPP-EN-02 is a transmitting power pack that wirelessly transmits a contact closure status from a wired occupancy sensor to an unlimited number of Lighting Quotient controllers that are within range. Its onboard 24 VDC output will power any wired 24 VDC occupancy sensor, eliminating the need for a separate wiring run, and in effect, transforming the wired device into a wireless transmitter that communicates with The Lighting Quotient CLC Series wireless load controllers and CCH control hubs.

The CPP-EN-02 can also serve as a signal repeater to effectively double the range of any Lighting Quotient switch, sensor or transmitter and can work in multiples or with other Lighting Quotient controllers to triple the signal range in most applications.

To order:

CPP-EN-02-WH-U-0 Wireless transmitting power pack

Specifications Overview Features Simple installation – 1/2" mounting nipple facilitates easy

connection to electrical junction box. Reconfigurable – can be repositioned as space or furniture

layouts occur, new tenant fit-outs require, or building life-cycle changes mandate.

Smart – embedded configuration software allows the user to easily link sensors to multiple load controllers without point-to-point control wiring.

Versatile – works seamlessly with The Lighting Quotient wireless wall switches, occupancy sensors and photo sensors to deliver a complete occupancy based and daylight responsive control solution.

Flexible – designed for open plan or private offices, libraries, schools, warehouses, etc.

Sustainable – wireless communication eliminates much of the wiring normally required for multi-zone distributed lighting control.

Power supply: 120/277VAC, 60Hz.

Power consumption: 5 watts maximum full load.

Communications: 902 MHz EnOcean® radio.

Transmission range: 100ft indoor (30m).

Operating temperature: 14°F to 113°F (–10°C to 45°C).

Relative humidity: 5% to 95% RH (non-condensing).

Weight: 10.4 oz. (294.8 grams).

Dimensions: 3.6"W x 1.93"H x 1.94"D (91.4mmW x 48mmH x 49.4mmD).

Mounting: 1/2" nipple.

Safety listing: ETL; conforms to UL 508 and CSA 22.2, UL 2043 Plenum rated.

Agency listing: FCC, IC.

Warranty: 2 years.

3/16

Wiring Diagram

WHITE

BLACK

N

120V

277V BROWN

ORANGE – ANTENNA

OccupancySENSOR

(By Others)

TRANSMITTINGPOWER PACK

+24VDC

Common

Control Output

RED

BLACK

YELLOW

Dimensions

CO4.0

SIDE

0.47"(12.0mm)

2.36"(60.0mm)

TOP

FRONT

antenna

REPEATERENABLE

buttonTEACHbutton

three wires

threewires

1.23"(31.3mm)

1.8"(45.7mm)

3.6" (91.4mm)

1.94"(49.4mm)

Page 8: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

CCH-EN-02 Wireless Control Hub Manual-ON / Auto-OFF

The CCH-EN-02 control hub uses wireless technology to extend daylight harvesting, demand response, and manual-ON/auto-OFF room switching and occupancy control to portable tambient luminaires. It also works in concert with the CFC furniture circuit control interface to control power receptacles in modular office workstations. The control hub adjusts luminaire light output based on daylight and occupancy levels communicated via wirelessly coupled photo and occupancy sensors. Remote control via wirelessly coupled switches, active circuit transmitters, and building energy management system gateways is also supported as well as control via motion sensors connected directly to the hub. Manual-ON/auto-OFF programming ensures compliance with the most aggressive energy codes in applications where portable furniture-mounted general lighting systems are deployed. Connected lighting and plug load circuits are energized only via EnOcean 902MHz PTM switching telegrams and manual pushbuttons on the hub. Occupancy telegrams initiate auto-OFF actions only.

The CCH-EN-02 mounts under work surfaces in office areas where tambient luminaires and furniture plug loads are to be controlled. Two channels of plug-load control are provided, and luminaire dimming and on/off off control is provided in concert with Channel 1.

See also model CCH-EN-03 for auto-ON/auto-OFF control of furniture plug load circuits only.

To order:

CCH-EN-02-WH-0 Wireless manual-ON/auto-OFF control hub

Specifications Overview Features Simple installation – plug into standard 120-volt convenience

power receptacle. Reconfigurable – can be repositioned as space or furniture

layouts occur, new tenant fit-outs require, or building life-cycle changes mandate.

Smart – embedded configuration software allows the user to easily adjust controller and sensor settings for uncomplicated commissioning.

Versatile – works seamlessly with The Lighting Quotient wireless wall switches, motion and light sensors, and furniture circuit control interface to deliver occupancy and daylight responsive control solutions.

Flexible – designed for open plan or private offices. Sustainable – wireless communication eliminates much of the

wiring normally required for multi-zone distributed lighting and plug-load control.

Power supply: 120VAC 60Hz to 24VDC plug-in power supply with integral 6ft long 24VDC power cord and 5.5mm x 2.1mm barrel connector (center positive).Power consumption: 1.0 watt, hub only, full load; with CMS-RJ add 0.05W ea. 2.5 watts, hub with Furniture Circuit Switching Interface,

both relays closed 4.5 watts, hub with Furniture Circuit Switching Interface,

both relays open Communications: 902 MHz EnOcean® radio.Operating temperature: 14°F to 113°F (–10°C to 45°C).Relative humidity: 5% to 95% RH (non-condensing).Weight: 6.2 oz. (176 grams) including power supply. Dimensions: 5" overall width x 3.11" x 1.06" (127mm overall x 79mm x 27mm)Mounting: Surface mount via double-sided tape or screws by others.Safety listing: UL listed Class II power supply.Agency listing: FCC, IC.Warranty: 2 years.

4/16

CO5.0

Motion sensor port

Circuit control port

3.11"(79mm)

5.00" (127mm)

Antenna

Switch/Dim port

Power connector

NOTE: Plug-in power supply included (not shown).

1.06"(27mm)

FixtureSW/DIM

OCCSensor

CircuitControl

Channel 1

Channel 2

Clear/Teach1 2

Power

Learn

Status

Rear ViewTop View

Pushbuttons

US Patent 9236738. Other US and foreign patents pending.

Page 9: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

CCH-EN-02 Wireless Control Hub

Compatible Devices

4/16

CO5.1

Self-powered WirelessDaylight SensorCLS-EN-02-WH-0

Self-powered WirelessMotion SensorsCMS-EN-03-WH-0Large motion occupancy sensorCMS-EN-04-WH-0Small motion occupancy sensorCMS-EN-05-WH-0Large motion vacancy sensorCMS-EN-06-WH-0Small motion vacancy sensor

Self-powered WirelessWall Switch/DimmersCWS-EN-03-WH-0Single channelCWS-EN-04-WH-0Dual channel

Active Circuit WirelessOccupancy TransmitterCLT-EN-02120-277V.

Furniture CircuitSwitching InterfaceCFC-RJ-01-M-06-H1-08-wire, 4 circuit, 120V.Consult factory for availability.

Workstation Motion SensorCMS-RJ-00-GR-0

RJ11 Extension Cables2-way splitter/coupler included.CRJ-11-010-BK (10 ft.)CRJ-11-015-BK (15 ft.)CRJ-11-025-BK (25 ft.) CRJ-11-035-BK (35 ft.)

5-way Cable SplitterCRJ-SP5-WH (5-way)

Connect luminaires with0-10V dimming ballasts,0-10V LED dimming drivers, and/or integral tambient LED switch/dim controllers up to a maximum of twelve (12) luminaires.

Order luminaires, RJ11 interconnect cables, and cable splitters separately. Contact factory for connection to luminaires without RJ11 dimming or switch/dim ports.

On/off switching of tambient luminaires with integral switch/dim controllers is provided via hub channel 1.

Power to luminaires with0-10V ballasts and drivers must be switched for ON/OFF control.

Connect up to ten (10) CMS-RJ workstation motion sensors. Connected motion sensors work in concert with linked wireless motion sensors to establish local occupancy status.

Use 2-way and 5-way RJ11 splitters to connect multiple luminaires and sensors.

Order sensors, RJ11 interconnect cables, and cable splitters separately.

CMS-RJ sensors automatically link to BOTH hub channel 1 AND hub channel 2.

Luminaire with 0-10V dimming ballast or driver

tambient LED luminaire withintegral 24VDC switch/dim controller

Plug CCH power cord into any unswitched 120V convenience power receptacle.

Link one (1) EnOcean 902MHz wireless daylight sensor and any number of EnOcean 902MHz wireless motion sensors, switches, and active circuit transmitters up to a total of twenty (20) devices. Order separately. Link daylight sensor to Channel 1. Link other devices to one or both hub channels.

CWS-EN-03CWS-EN-04

CMS-EN-03CMS-EN-04CMS-EN-05CMS-EN-06

CLS-EN-02

CCH-EN-02

CLT-EN-02

CFC-RJ-01

CMS-RJ-00

Connect (1) CFC-RJFurniture CircuitSwitching Interface to implement two channels of plug-load control in modular furniture wiring systems. Order separately. Contact factory for availability.

Each wireless device can communicate with an unlimited number of CCH hubs, CLC Series controllers, and integral wireless luminaire controllers in a 75 ft. range.

Furniture system modular wiring

Typical Plug-and-Play Connection DiagramNote: Devices pictured are not precisely in scale to each other.

Page 10: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

CCH-EN-03 Wireless Control Hub Auto-ON / Auto-OFF

The CCH-EN-03 works in concert with the CFC furniture circuit control interface to control power receptacles in modular office workstations. The control hub communicates with the CFC interface to switch circuits feeding furniture power receptacles based on occupancy conditions communicated via wirelessly coupled sensors and active circuit transmitters. Remote control via wirelessly coupled wall switches and building energy management system gateways is also supported as well as control via motion sensors connected directly to the hub.

The CCH-EN-03 mounts under work surfaces in office areas where furniture plug loads are to be controlled. Two channels of plug-load control are provided. Each control hub can receive input from up to 10 wired motion sensors and up to 20 wireless devices including wireless switches, motion sensors, and active circuit transmitters. These enable great flexibility in creating occupancy zones within any open plan office.

Push-and-play wireless onsite commissioning allows installers and facility operators to easily manage and change occupancy zones and vacancy time delays without any tools. Wireless commissioning software is also supported.

For manual-ON/auto-OFF control of portable furniture-mounted lighting systems and plug load circuits, see model CCH-EN-02.

To order:

CCH-EN-03-WH-0 Wireless auto-ON/auto-OFF control hub

Specifications Overview Features Simple installation – plug into standard 120-volt convenience

power receptacle.

Reconfigurable – can be repositioned as space or furniture layouts occur, new tenant fit-outs require, or building life-cycle changes mandate.

Smart – embedded configuration software allows the user to easily adjust controller and sensor settings for uncomplicated commissioning.

Versatile – works seamlessly with The Lighting Quotient furniture circuit control interface, motion sensors, and active circuit transmitter to deliver occupancy responsive plug load control solutions.

Flexible – designed for open plan or private offices.

Sustainable – wireless communication eliminates much of the wiring normally required for multi-zone distributed plug-load control.

Power supply: 120VAC 60Hz to 24VDC plug-in power supply with integral 6ft long 24VDC power cord and 5.5mm x 2.1mm barrel connector (center positive).Power consumption: 2.5 watts, hub with Furniture Circuit Switching Interface,

both relays closed 4.5 watts, hub with Furniture Circuit Switching Interface,

both relays open Communications: 902 MHz EnOcean® radio.Operating temperature: 14°F to 113°F (–10°C to 45°C).Relative humidity: 5% to 95% RH (non-condensing).Weight: 6.2 oz. (176 grams) including power supply. Dimensions: 5" overall width x 3.11" x 1.06" (127mm overall x 79mm x 27mm)Mounting: Surface mount via double-sided tape or screws by others.Safety listing: UL listed Class II power supply.Agency listing: FCC, IC.Warranty: 2 years.

4/16

CO5.2

Motion sensor port

Circuit control port

3.11"(79mm)

5.00" (127mm)

Antenna

Power connector

NOTE: Plug-in power supply included (not shown).

1.06"(27mm)

OCCSensor

CircuitControl

Channel 1

Channel 2

Clear/Teach1 2

Power

Learn

Status

Rear ViewTop View

Pushbuttons

US Patent 9236738. Other US and foreign patents pending.

Page 11: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

CCH-EN-03

Compatible Devices

4/16

CO5.3

Furniture CircuitSwitching InterfaceCFC-RJ-01-M-06-H1-08-wire, 4 circuit, 120V.

Self-powered WirelessMotion SensorsCMS-EN-03-WH-0Large motion occupancy sensorCMS-EN-04-WH-0Small motion occupancy sensor

Workstation Motion SensorCMS-RJ-00-GR-0

Active Circuit WirelessOccupancy TransmitterCLT-EN-02120-277V

Self-powered WirelessWall SwitchCWS-EN-03-WH-0Single channelCWS-EN-04-WH-0Dual channel

RJ11 Extension Cables2-way splitter/coupler included.CRJ-11-010-BK (10 ft.)CRJ-11-015-BK (15 ft.)CRJ-11-025-BK (25 ft.) CRJ-11-035-BK (35 ft.)

5-way Cable SplitterCRJ-11-SP5

Connect up to ten (10) CMS-RJ-00 workstation motion sensors. Connected motion sensors work in concert with linked wireless motion sensors to turn furniture circuits OFF when areas are not occupied.

Use CRJ-11 RJ11 control cable extension kits and 5-way control cable splitters to connect multiple workstation sensors to a single control hub.

Order sensors, control cable extension kits and 5-way control cable splitters separately.

CMS-RJ-00 sensors automatically link to BOTH hub Channel 1 AND hub Channel 2.

Plug CCH power cord into any unswitched 120V convenience power receptacle.

Link any number of CWS-EN wireless switches, CMS-EN wireless occupancy sensors, and CLT-EN active circuit transmitters up to a total of twenty (20) devices. Order separately. Link each device to control one or both hub channels.

CWS-EN-03CWS-EN-04

CMS-EN-03CMS-EN-04

CCH-EN-03

CLT-EN-02

CFC-RJ-01

CMS-RJ-00

Each wireless device can communicate with an unlimited number of CCH hubs and CLC Series controllers in a 75 ft. range.

Typical Plug-and-Play Connection DiagramNote: Devices pictured are not precisely in scale to each other.

Connect (1) CFC-RJ-01 Furniture Circuit Switching Interface to implement two (2) channels of plug load control in modular furniture wiring systems. Order CFC-RJ-01 interface separately.

CRJ-11-0 _ _

CRJ-11-SP5

Unswitchedreceptacle

Unswitchedreceptacle

Unswitchedreceptacle

Unswitchedreceptacle

Page 12: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

The CLC wireless load controllers offer a simple and sustainable solution for controlling lighting, electric circuits, and plug loads for energy savings and code compliance. Using wireless technology, these controllers eliminate much of the wiring typically associated with building energy management systems.

The model CLC-EN-06 controller is preconfigured to switch connected loads in response to signals from wirelessly coupled occupancy sensors, photo sensors, wall switches, and other devices that transmit commands using the EnOcean® 2MHz wireless protocol. It implements integrated switching control strategies that include time-of-day scheduling, occupancy or vacancy response, daylight harvesting and demand response.

Intelligent onboard configuration software supports pushbutton wireless commissioning that allows installers and facility operators to easily manage and change settings via linked wireless sensors and switches. Programmable features include: vacancy time out and daylight switching set point. Wireless commissioning software is also supported. For a load controller with dimming, refer to CLC-EN-11.

To order:

CLC-EN-06-WH-U-0 Wireless load controller

Simple installation – 1/2" mounting nipple facilitates easy connection to electrical junction box.

Reconfigurable – can be repositioned as space or furniture layouts change, new tenant fit-outs require, or building life-cycle changes mandate.

Smart – embedded configuration software allows the user to easily adjust controller and sensor settings for uncomplicated commissioning.

Reliable – near cross switching technology for long relay life. Versatile – works seamlessly with The Lighting Quotient

wireless wall switches, occupancy sensors and photo sensors to deliver a complete occupancy based and daylight responsive control solution.

Flexible – designed for open plan or private offices, libraries, schools, warehouses, etc.

Sustainable – wireless communication eliminates much of the wiring normally required for multi-zone distributed lighting and plug load control.

Power supply: 120/277/347VAC, 60Hz.

Power consumption: 5 watts maximum full load 3.75 watts static state

Load rating: 20A @ 120 or 277VAC. 15A @ 347VAC.

Communications: 902 MHz EnOcean® radio.

Operating temperature: 14°F to 113°F (–10°C to 45°C).

Relative humidity: 5% to 95% RH (non-condensing).

Weight: 13.5 oz. (385 grams).

Dimensions: 3.6"W x 1.93"H x 1.94"D (91.4mmW x 48mmH x 49.4mmD).

Mounting: 1/2" nipple.

Safety listing: ETL; conforms to UL 508 and CSA 22.2, UL 2043 Plenum rated.

Agency listing: FCC, IC.

Warranty: 2 years.

CLC-EN-06 Wireless Load Controller

Specifications Overview Features

10/15

Wiring Diagram

N

277V

120V

ORANGE – ANTENNA

RED (Load)

RED (Line)

LOAD

WHITE (Neutral)

CONTROLLERWHITE

BLACK

BROWN

347V YELLOW

CO6.0

Dimensions

SIDE

TOP

FRONT

antenna

CLEARbutton

LEARNbutton

six wires0.47"

(12.0mm)

2.36"(60.0mm)

1.23"(31.3mm)

1.8"(45.7mm)

3.6" (91.4mm)

1.94"(49.4mm)

Page 13: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

Typical ApplicationUse CLC-EN-06 for ON/OFF control of office lighting and plug loads. Link to wireless, self-powered CMS series motion sensors for auto-ON/auto-OFF applications (CMS-EN-05 and CMS-EN-06 may require batteries for auto-ON in non-daylit spaces). Add CWS-EN-03 and/or CWS-EN-04 self-powered switches to implement manual-ON/auto-OFF lighting control.

CLC-EN-06

Wireless Occupancy or Vacancy Sensors CMS-EN-03, CMS-EN-04, CMS-EN-05, or CMS-EN-06

Wireless Switch CWS-EN-03

CO6.1

CLC-EN-06

Compatible Devices

Self-powered WirelessWall Switch/DimmersCWS-EN-03-WH-0Single channelCWS-EN-04-WH-0Dual channel

Self-powered WirelessMotion SensorsCMS-EN-03-WH-0Large motion occupancy sensorCMS-EN-04-WH-0Small motion occupancy sensorCMS-EN-05-WH-0Large motion vacancy sensorCMS-EN-06-WH-0Small motion vacancy sensor

Active Circuit WirelessOccupancy TransmitterCLT-EN-02120-277V

Wireless TransmittingPower PackCPP-EN-02Convert any third-party 24V sensor into a compatible wireless device

Note: Devices pictured are not precisely in scale to each other.

10/15

CLC-EN-06

Page 14: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

The CLT-EN Active Circuit Transmitter transmits a wireless occupancy signal to communicate the status of a reference circuit or switch leg to an unlimited number of Lighting Quotient CLC controllers and CCH control hubs within range to implement switching/occupancy/vacancy response over remote lighting, electrical circuits, and plug loads for energy savings and code compliance.

The Lighting Quotient CLT wireless transmitters, CLC load controllers, and CCH control hubs eliminate much of the wiring typically associated with building energy management systems in both new and existing buildings to establish a flexible scalable platform for single spaces or whole buildings.

The CLT-EN Active Circuit Transmitter can also serve as a signal repeater to effectively double the range of any Lighting Quotient switch, sensor or transmitter and can work in multiples or with other Lighting Quotient controllers to triple the signal range in most applications.

To order:

CLT-EN-02-WH-U-0 Wireless active circuit transmitter, 120-277VAC

Simple installation – compact size allows controller to reside within an electrical junction box.

Reconfigurable – can be repositioned as space or furniture layouts occur, new tenant fit-outs require, or building life-cycle changes mandate.

Smart – embedded configuration software allows the user to easily link the transmitter to multiple load controllers without point-to-point control wiring.

Versatile – works seamlessly with The Lighting Quotient wireless controllers to gain control over remote electrical loads and to emulate existing switching events.

Flexible – designed for open plan or private offices, libraries, schools, warehouses, etc.

Sustainable – wireless communication eliminates much of the wiring normally required for multi-zone distributed lighting control.

Power supply: 120-277VAC, 60Hz.

Power consumption: 1.0 watts maximum full load.

Communications: 902 MHz EnOcean® radio.

Operating temperature: 14°F to 113°F (–10°C to 45°C).

Relative humidity: 5% to 95% RH (non-condensing).

Weight: 2.0 oz. (46 grams).

Dimensions: 2.19"H x 1.48"W x 1.0"D (55.6mmH x 37.7mmW x 25.5mmD).

Mounting: Surface mount within receptacle or wall box via double-sided tape or screws, by others.

Safety listing: ETL; conforms to UL 508 and CSA 22.2.

Agency listing: FCC, IC.

Warranty: 2 years.

CLT-EN-02 Wireless Active Circuit Transmitter

Wiring Diagram

Specifications Overview Features

1/15

TRANSMITTERORANGE – ANTENNA

BLACK120-277V

Neutral

Dimensions

CO12.0

FRONT

SIDE

TOP

1.0" (25.5mm) 1.48" (37.7mm)

2.19"(55.6mm)

Page 15: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

CFC-RJ-01 Furniture Circuit Switching Interface

The CFC-RJ-01 furniture circuit switching interface offers a simple and sustainable solution for controlling plug-load circuits associated with modular office furniture for energy savings and code compliance. The interface works in concert with a CCH-EN-02 or CCH-EN-03 wireless control hub to control power receptacles in modular office workstations based on occupancy conditions communicated to the hub via wirelessly coupled sensors and active circuit transmitters (order hub and wireless sensors/transmitters separately). The CFC-RJ-01 eliminates the engineering design and field wiring coordination typically associated with delivering a combination of switched and unswitched power to modular furniture connections.

Integral 8-wire cable assemblies and two (2) integral normally-closed switching relays provide for up to two (2) independently switched and two (2) unswitched 20A circuits. The furniture circuit control interface receives power and switching instructions from the hub via a 6ft RJ11 plug-and-play control cable (provided).

To order:

CFC-RJ-01-M-06-H1-0 Furniture Circuit Switching Interface

Specifications Overview Features Simple installation – connect in-line with furniture system

starter cable; connect to control hub with plug-and-play control cable (provided).

Reconfigurable – can be repositioned as space or furniture layouts occur, new tenant fit-outs require, or building life-cycle changes mandate.

Smart – default ON operation when operated without connected control hub; maximum control circuit power state occurs when plug loads are OFF.

Versatile – works seamlessly with The Lighting Quotient wireless control hubs to convert unswitched furniture circuits to combination switched and unswitched power feeds for plug-load control.

Flexible – designed for use with all modular furniture systems and multi-circuit plug-load installations.

Sustainable – point of use implementation eliminates embedded building controls and dedicated circuiting normally required for open office plug-load control.

Power supply: 24VDC power via RJ11 control port and accessory control.Power consumption: 0 watts, both relays closed 1.0 watt, one relay open 2.0 watts, both relays open Communications: Digital link to accessory control hub via RJ11 control cable (provided).Operating temperature: 14°F to 113°F (–10°C to 45°C).Relative humidity: 5% to 95% RH (non-condensing).Dimensions: enclosure rests on predrilled mounting base 12" overall length x 2.63"W x 1.65"D (305mm overall length x 67mmW x 42mmD), metal flex/8-wire: 12" and 72" (305mm, 1829mm) Finish: Black painted enclosure. Mounting: Surface mount via screws by others.Safety listing: ETL listed.Warranty: 2 years.

6/16

CO13.0

Status LED

8-wire metal flex

12.00"(305mm)

Control port

NOTE: 6ft RJ11 control cable included (not shown; see illustration at right).

1.65"(42mm)

Side View

Top View

2.63"(67mm)

12.00"(305mm)

72.00"(1829mm)

10.00"(254mm)

8-wire metal flex

US Patent 9236738. Other US and foreign patents pending.

Page 16: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

CFC-RJ-01

Compatible Devices

6/16

CO13.1

Wireless Control HubCCH-EN-02Manual-ON/auto-OFF hub with auxiliary dimming outputCCH-EN-03Auto-ON/auto-OFF hub,dimming disabled

Control cable(provided withCFC-RJ-01)

CCH-EN-02 or CCH-EN-03(order separately)

Connection Diagram

Plug-in power supply(provided with CCH-EN-02/CCH-EN-03)

Furniture system receptacles

Unswitchedreceptacle

Switchedreceptacle

Unswitchedreceptacle

Switchedreceptacle

Furniture system multi-circuit starter cable

CFC-RJ-01

(J-box by others) Connect to furniture system starter cable

Connect to building power circuits

Wiring Diagram

— Black (1H), Switched (Channel 1)

— Red (2H), Switched (Channel 2)

— Pink (4H), Unswitched

— White (1-2N)

— Green (1-2G)

— Blue (3H), Unswitched

— White/Black (3-4N)

— Green/Yellow (3-4G)

Black (1H) —

Red (2H) —

Pink (4H) —

White (1-2N) —

Green (1-2G) —

Blue (3H) —

White/Black (3-4N) —

Green/Yellow (3-4G) —

CFC-RJ-01

“2+2” configuration shown. Refer to CFC Installation Guide for additional wiring diagrams. COLOR GAUGE COLOR GAUGE

Black 12 White 10

Red 12 White/Black 10

Blue 12

Pink 12

Green 12

Green/Yellow 12

Wire Gauges

Page 17: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

CMS-EN-05, CMS-EN-06 Wireless Vacancy Sensors

The CMS-EN-05/06 wireless, battery-free vacancy sensors generate their own power using two integral photovoltaic cells that harvest energy from ambient light in the space. When light is available, they begin to operate automatically within minutes and continue to operate without batteries until the available light falls below 6 footcandles, making them suitable for use where auto-OFF vacancy response lighting and plug-load control is desired. For auto-ON occupancy response and/or operation in low-ambient conditions, the sensors accept a field installable #CR1632 battery. For battery-free auto-ON applications, see CMS-EN-03/04 sensors. CMS-EN-05/06 sensors use passive infrared detection circuitry and wireless transmission to send occupancy signals to linked CLC Series load controllers and CCH control hubs within range. When occupancy signals cease, the load controllers and hubs respond by dimming and/or switching their loads OFF after a preset auto-OFF time delay. CMS-EN-05/06 sensors also double as commissioning tools for adjusting the auto-OFF time delay of each linked controller.CMS-EN occupancy sensors require no hardwired electrical connections. This greatly simplifies the installation and commissioning process. The sensors can be easily moved or repositioned as field conditions or changes in the space necessitate, ensuring maximum flexibility and optimum performance.

To order:CMS-EN-05-WH-0 Wireless vacancy sensor,

large motionCMS-EN-06-WH-0 Wireless vacancy sensor,

small motion

Specifications Overview Features Self powered – no wiring or batteries needed. Simple installation – no special tools or hardware required. Reconfigurable – easily repositioned as space or furniture

layouts change. Smart – embedded configuration software allows the user to

easily adjust controller and sensor settings for uncomplicated commissioning.

Maintenance free – no batteries to replace or electrical wires to service.

Flexible – designed for open plan offices, private offices, and similar spaces.

Programmable – easy commissioning: manual through LINK button or via optional software.

Sustainable – no electrical power, wiring, batteries or maintenance; reconfigurable; long product life delivers significant savings for many years to come.

Power supply: Integral solar cells.Initial charge operation: < 2 minutes @ 6 footcandles (65 lux).Operational light level: 6 footcandles (65 lux) minimum.Communications: 902 MHz EnOcean® radio.Transmission range: 75ft indoor (23m).Operating temperature: 14°F to 122°F (–10°C to 50°C).Relative humidity: 5% to 92% RH (non-condensing).Weight: 2.4 oz. (68 grams).Dimensions: 3.86" dia. x 1.00" (98mm dia. x 25.5mm).Mounting: Surface mount via integral magnets, poke-through wire straps (included), double-sided tape (by others), or screws (by others).Safety listing: UL listed Class II power supply.Agency listing: FCC, IC.Warranty: 2 years.

3/16

CO14.0

Side View

Front View

1.0"(25.5mm)

3.86" (98.0mm)

PIR sensor lens

Link button(under cover)

Solar panel1 of 2

Antenna(under cover)

Magnet, 1 of 2

Mounting hole, 1 of 2 (for screws by others)

3.00" Mounting circle

Mounting hole, 1 of 4(for wire mounting straps, provided)

Rear View

Page 18: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

CO14.1

CMS-EN-05, CMS-EN-06

Compatible Devices

Wireless Load ControllerCLC-EN-0620A 120/277V wirelessswitching controller CLC-EN-1120A 120/277V wirelessswitch/dim controllerwith 0-10V dimming

Wireless Control HubCCH-EN-02Manual-ON/auto-OFF hub with auxiliary dimming output

Furniture CircuitSwitching InterfaceCFC-RJ-018-wire, 4 circuit, 120V.

Typical ApplicationNote: Devices pictured are not precisely in scale to each other.

3/16

Use CMS-EN-05 and CMS-EN-06 for auto-OFF control of office lighting and plug loads. For auto-ON applications, use with field installed batteries or see CMS-EN-03 and CMS-EN-04 self-powered wireless occupancy sensors.

CMS-EN-06

Wireless Load ControllerCLC-EN-06, CLC-EN-11

CMS-EN-05CMS-EN-06

Wireless Control Hub CCH-EN-02

Unswitched

Switched

Self-powered Wall SwitchCWS-EN-03, CWS-EN-04

Furniture Circuit SwitchingInterface CFC-RJ-01

Detection Coverage

7 ft.

2.5 ft.

18 ft. (5.5m) Ø59 ft. (18.0m) Ø

Largemotion

Mediummotion

Largemotion

7 ft.

2.5 ft.

12 ft. (3.7m) Ø30 ft. (9.1m) Ø

Mediummotion

Smallmotion

Mediummotion

CMS-EN-05 (with large motion lens) CMS-EN-06 (with small motion lens)

Page 19: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

Certain products illustrated may be covered by applicable patents and patents pend-ing. These specifications supersede all prior publications and are subject to change without notice. Copyright © 2016 Sylvan R. Shemitz Designs, LLC, all rights reserved.

114 Boston Post Road, West Haven, Connecticut 06516, USA

Voice 203.931.4455 Fax 203.931.4464 thelightingquotient.com

®

CLC wireless load controllers offer a simple and sustainable solution for controlling lighting, electric circuits, and plug loads for energy savings and code compliance. Using wireless technology, these controllers eliminate much of the wiring typically associated with building energy management systems.The model CLC-EN-11 controller is preconfigured to switch connected loads in response to signals from wirelessly coupled occupancy sensors, photo sensors, wall switches, and other devices that transmit commands using the EnOcean® 902MHz wireless protocol. It implements integrated switching control strategies that include time-of-day scheduling, occupancy or vacancy response, daylight harvesting and demand response. In addition, the CLC-EN-11 includes a 0-10V analog dimming output for controlling fluorescent, LED and HID lighting.Intelligent onboard configuration software supports pushbutton wireless commissioning that allows installers and facility operators to easily manage and change settings via linked wireless sensors and switches. Programmable features include: vacancy time out, and daylight dimming set point. Wireless commissioning software is also supported.

To order:

CLC-EN-11-WH-U-0 Wireless load controller with dimming

Simple installation – 1/2" mounting nipple facilitates easy connection to electrical junction box.

Reconfigurable – can be repositioned as space or furniture layouts change, new tenant fit-outs require, or building life-cycle changes mandate.

Smart – embedded configuration software allows the user to easily adjust controller and sensor settings for uncomplicated commissioning.

Reliable – near cross switching technology for long relay life. Versatile – works seamlessly with The Lighting Quotient

wireless wall switches, occupancy sensors and photo sensors to deliver a complete occupancy based and daylight responsive control solution.

Flexible – designed for open plan or private offices, libraries, schools, warehouses, etc.

Sustainable – wireless communication eliminates much of the wiring normally required for multi-zone distributed lighting and plug load control.

Power supply: 120/277VAC, 60Hz. Consult factory for 347VAC, 60Hz.

Power consumption: 5 watts maximum full load 3.75 watts static state

Load rating: 20A @ 120 or 277VAC. 15A @ 347VAC.

Communications: 902 MHz EnOcean® radio.

Operating temperature: 14°F to 113°F (–10°C to 45°C).

Relative humidity: 5% to 95% RH (non-condensing).

Weight: 13.5 oz. (385 grams).

Dimensions: 3.6"W x 1.93"H x 1.94"D (91.4mmW x 48mmH x 49.4mmD).

Mounting: 1/2" nipple.

Safety listing: ETL; conforms to UL 508 and CSA 22.2, UL 2043 Plenum rated.

Agency listing: FCC, IC.

Warranty: 2 years.

CLC-EN-11 Wireless Load Controller with Dimming

Specifications Overview Features

3/16

Wiring Diagram

ORANGE – ANTENNA

DimmingBALLAST

0-10V GRAY

0-10V VIOLET

N

277V

120VRED (Load)

RED (Line)

LOAD

WHITE (Neutral)

CONTROLLERWHITE

BLACK

BROWN

Dimensions

SIDE

TOP

FRONT

CLEARbutton

LEARNbutton

seven wires0.47"

(12.0mm)

2.36"(60.0mm)

1.23"(31.3mm)

1.8"(45.7mm)

3.6" (91.4mm)

1.94"(49.4mm)

antenna

CO15.0

Page 20: Overview Features Specifications - The Lighting Quotient specifications supersede all prior publications and are subject to change ... load controller CLC-EN-11 in place of CLC-EN-06

®

CO15.1

3/16

Typical ApplicationUse CLC-EN-11 for ON/OFF and dimming control of office lighting. Link to CWS-EN-03 and/or CWS-EN-04 self-powered wall switch/dimmers to implement manual-ON/OFF and manual dimming. Add CLS-EN-02 self-powered wireless daylight sensor for automatic daylight response. Add any CMS series self-powered wireless motion sensors for automatic vacancy shut-OFF.

CLC-EN-11

Wireless Vacancy Sensor CMS-EN-06

Wireless Switch CWS-EN-03

Compatible Devices

Self-powered WirelessWall Switch/DimmersCWS-EN-03-WH-0Single channelCWS-EN-04-WH-0Dual channel

Self-powered WirelessDaylight SensorCLS-EN-02-WH-0

Self-powered WirelessMotion SensorsCMS-EN-03-WH-0Large motion occupancy sensorCMS-EN-04-WH-0Small motion occupancy sensorCMS-EN-05-WH-0Large motion vacancy sensorCMS-EN-06-WH-0Small motion vacancy sensor

Active Circuit WirelessOccupancy TransmitterCLT-EN-02120-277V

Wireless TransmittingPower PackCPP-EN-02Convert any third-party 24V sensor into a compatible wireless device

Note: Devices pictured are not precisely in scale to each other.

CLC-EN-11

Wireless Daylight Sensor CLS-EN-02

Wireless Vacancy Sensor CMS-EN-06