MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 1 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
EXPEDIENTE TECNICO
TOMO I
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN
DEL SERVICIO DE DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO
VILLA ANCAYO, DISTRITO PAMPA HERMOSA - SATIPO - JUNN
NOVIEMBRE DE 2014
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 2 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
NDICE
MEMORIA DESCRIPTIVA
CAPTULO I .............................................................................................................................. 4
1. ASPECTOS GENERALES ................................................................................................ 4
1.1. NOMBRE DEL PROYECTO ................................................................................................. 4
1.2. LOCALIZACIN ................................................................................................................. 4
1.3. GENERALIDADES Y ANTECEDENTES ................................................................................ 6
1.3.1. MARCO DE REFERENCIA ..................................................................................................................6
1.3.2. ANTECEDENTES DEL PROYECTO....................................................................................................8
1.4. OBJETIVOS ....................................................................................................................... 9
1.4.1. OBJETIVO DEL PROYECTO ...............................................................................................................9
1.4.2. OBJETIVO GENERAL ..........................................................................................................................9
1.4.3. OBJETIVO ESPECFICO ......................................................................................................................9
1.5. PROPIETARIO DE LA OBRA ........................................................................................... 10
1.6. CARACTERSTICAS GENERALES DE LA LOCALIDAD ...................................................... 10
1.6.1. ACCESO A LA LOCALIDAD ............................................................................................................. 10
1.6.2. POBLACIN Y VIVIENDA ............................................................................................................... 11
1.6.3. CARACTERSTICAS DE SERVICIOS EXISTENTES ........................................................................ 12
1.7. INFORMACIN SOCIO-ECONMICA ............................................................................... 13
1.7.1. EDUCACIN ..................................................................................................................................... 13
1.7.2. SALUD ............................................................................................................................................... 13
2. PROYECCIONES POBLACIONALES Y ANLISIS DE OFERTA Y DEMANDA ... 14
2.1. ESTUDIO POBLACIONAL ............................................................................................... 16
2.1.1. POBLACIN ACTUAL ...................................................................................................................... 16
2.1.2. DENSIDAD POBLACIONAL POR VIVIENDA ................................................................................. 16
2.1.3. TASA DE CRECIMIENTO................................................................................................................. 17
2.1.4. POBLACIN Y VIVIENDAS FUTURAS ........................................................................................... 18
2.2. DEMANDA PROYECTADA DE AGUA POTABLE ............................................................... 19
2.3. GENERACIN PROYECTADA DE AGUAS RESIDUALES .................................................... 24
2.4. ANLISIS DE LA OFERTA ............................................................................................... 24
2.4.1. SISTEMA DE AGUA POTABLE ........................................................................................................ 26
2.4.2. SISTEMA DE SANEAMIENTO ......................................................................................................... 32
2.5. BALANCE OFERTA-DEMANDA ...................................................................................... 33
2.5.1. SISTEMA DE AGUA POTABLE ........................................................................................................ 34
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 3 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
3. DESCRIPCIN DE OBRAS DE AGUA Y SANEAMIENTO ...................................... 38
3.1. DESCRIPCIN DE OBRAS PROYECTADAS DEL SISTEMA DE AGUA POTABLE ................ 38
3.1.1. SISTEMA Sector Central .................................................................................................... 38
3.1.1.1. CAPTACIN ..................................................................................................................................... 38
3.1.1.2. LNEA DE CONDUCCIN ................................................................................................................ 41
3.1.1.3. RESERVORIO APOYADO V=9.00M3 ................................................................................. 41
3.1.1.4. REDES DE DISTRIBUCIN............................................................................................................. 45
3.1.1.5. VLVULA DE CONTROL ................................................................................................................. 46
3.1.1.6. VLVULA DE AIRE ......................................................................................................................... 46
3.1.1.7. VLVULA DE PURGA ...................................................................................................................... 47
3.1.1.8. CONEXIONES DOMICILIARIAS ...................................................................................................... 48
3.1.1.9. CONEXIONES INTRADOMICILIARIAS .......................................................................................... 50
3.1.2 SISTEMA "Sector N02"51
3.1.2.1. CAPTACIN RESERVORIO ............................................................................................................. 51
3.1.2.2. REDES DE DISTRIBUCIN.......................................................................................................... 545
3.1.2.3. VLVULA DE CONTROL .............................................................................................................. 546
3.1.2.4. VLVULA DE PURGA ...................................................................................................................... 47
3.1.2.5. CONEXIONES DOMICILIARIAS ...................................................................................................... 57
3.1.2.6. CONEXIONES INTRADOMICILIARIAS .......................................................................................... 58
3.1.2.7. CAMARA ROMPE RPESION TIPO VII.59
3.2. DESCRIPCIN DE OBRAS PROYECTADAS DEL SISTEMA DE SANEAMIENTO..61
3.2.1. UNIDAD BSICA DE SANEAMIENTO TIPO ARRASTRE HIDRAULICO.61
4. RESUMEN DEL ANLISIS DE VULNERABILIDAD Y RIESGO ............................. 68
5. RESUMEN DE EVALUACION DE IMPACTO AMBIENTAL ................................... 72
6. RESUMEN DE MEMORIA DE CLCULO Y DISEOS............................................. 77
7. RESUMEN GENERAL DE COSTO DE OBRA.......................................................... 77
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 4 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
MEMORIA DESCRIPTIVA Y JUSTIFICATIVA
CAPTULO I
1. ASPECTOS GENERALES
1.1. Nombre del proyecto
El nombre del proyecto es: MEJORAMIENTO Y AMPLIACIN DEL SERVICIO
DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE DISPOSICIN
SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO,
DISTRITO PAMPA HERMOSA - SATIPO - JUNN
1.2. Localizacin
La localidad de Villa Ancayo geopoltica se ubica en el Departamento de Junn,
Provincia de Satipo, Distrito de Pampa Hermosa, en el centro poblado VILLA
ANCAYO.A una altitud aproximada de 886.96 m.s.n.m. En las coordenadas
UTM WGS84: 530,331.98 E; 8747933.61 N, con cdigo UBIGEO
120605040017
Imagen 1. Plano de situacin
Departamento de Junn Regin de Junn
ESCALA APROX.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 5 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Provincia de Satipo
Distrito: Pampa Hermosa
Localidad de Villa Ancayo en el distrito de Pampa Hermosa
Localidad Villa
Ancayo
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 6 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
1.3. Generalidades y antecedentes
1.3.1. Marco de referencia
1.3.1.1. Unidad ejecutora del proyecto
Sector: Vivienda, Construccin y Saneamiento
Pliego: Ministerio de Vivienda, Construccin y Saneamiento
Nombre: Programa Nacional de Saneamiento Rural (PNSR)
rgano Tcnico Responsable: Unidad de Desarrollo de Infraestructura -
PNSR
1.3.1.2. Marco de referencia
El PNSR tiene por objetivo el contribuir al incremento de la cobertura de los
servicios de agua y saneamiento a la poblacin de las localidades rurales y
pequeas ciudades del mbito de intervencin del Programa a nivel nacional,
que en este tem corresponde a la regin Junn.
El Programa considera soluciones integrales a la problemtica del agua potable
y saneamiento. Comprende los estudios y ejecucin de los aspectos tcnicos de
las obras de infraestructura y la atencin a los aspectos sociales como ser
fortalecimiento institucional, de gestin y ambiental. El desarrollo de
capacidades locales, entre ellos, el de los municipios distritales para que
cumplan su rol de ser gestores de la promocin y sostenibilidad de los servicios
en las localidades de su mbito, as como la fiscalizacin de la gestin rural de
los servicios a travs de un rea Tcnica (ATMS); adicionalmente, el rol de
participacin de las comunidades en la conformacin de esquemas de gestin
comunitaria de los servicios en la zona rural mediante una Organizacin
Comunal (JASS u otras); y en el mbito de pequeas ciudades la prestacin de
los servicios, a travs de Prestador de Servicio (UG y/u OE).
El Consorcio Consultor Rural N03 es la firma Consultora de Estudios
contratada por el PNSR para desarrollar los Estudios de Pre-Inversin (perfiles
de proyectos que consideran los aspectos tcnicos, sociales, de fortalecimiento
institucional, gestin y ambiental, en concordancia con las normas del Sistema
Nacional de Inversin Pblica vigente); e Inversin (Expedientes de proyectos
de agua y saneamiento que considera aspectos tcnico, social, de
fortalecimiento institucional, gestin y ambiental en concordancia con las
normas nacionales vigentes), para proyectos de agua y saneamiento en
localidades de diversas regiones del Per entre ellas de la Regin de Junin.
Incluye la definicin del componente institucional (apoyo a las comunidades y a
los municipios en el montaje de los esquemas de gestin de los servicios de
agua y saneamiento) para asegurar una adecuada gestin de los servicios en
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 7 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
las comunidades beneficiarias.
El proyecto de agua potable y saneamiento de la localidad de Villa Ancayo, est
incluido en las localidades que se ejecutarn con el PNSR y es motivo del
presente estudio.
La localidad de Villa Ancayo cuenta con servicio de agua corriente no potable de
baja cobertura, y en relacin a la infraestructura de saneamiento se tiene que
sta es precaria. Es por tanto preciso intervenir en estos aspectos ya que los
intentos de solucin que se dieron en los ltimos aos no han permanecido en
el tiempo por falta de una concientizacin a la poblacin en la operacin y
mantenimiento de los sistemas, y por las deficientes instalaciones que fueron
construidas.
a) En el contexto local - Plan Distrital
La Municipalidad Distrital de Pampa Hermosa ha firmado un convenio marco
con el PNSR, asumiendo compromisos y responsabilidades de gestin, durante
el ciclo del proyecto.
La Municipalidad Distrital, ha priorizado el mejoramiento y ampliacin del
servicio de agua potable e instalacin del servicio de disposicin sanitaria
excretas en el centro poblado Villa Ancayo, segn el Plan de Desarrollo
Concertado Local 2009 2020 en los Lineamientos de Poltica por Objetivos
Estratgicos 01: 100% de las familias de los 44 caseros consumirn agua
saludable, mediante sistemas de agua potable eficientes administrados
concertadamente con la poblacin, Municipalidad y el Sector Salud.
b) En el contexto Regional - Plan de Desarrollo Regional Concertado de Junin
El proyecto de Mejoramiento y ampliacin del servicio de agua potable e
instalacin del servicio de disposicin sanitaria excretas en el centro poblado
Villa Ancayo en el Distrito de Pampa Hermosa, Provincia de Satipo se encuentra
enmarcado en los objetivos, programas y actores por ejes estratgicos del Plan
de Desarrollo Regional Concertado de Junn, especficamente dentro del eje
estratgico Condiciones de vida de la poblacin, objetivo estratgico
Garantizar el acceso y la atencin integral de la salud con servicios de calidad
adecuados a las necesidades de la poblacin y bajo criterios de equidad. Se
enmarca en los Objetivos especficos de Formular y Ejecutar Planes y
proyectos de salud y mejorar los servicios bsicos
c) Prioridad al Proyecto de Inversin Pblica de la localidad de Villa Ancayo
Para efectos de la implementacin de las intervenciones del Programa Nacional
de Saneamiento Rural se ha establecido como criterios de priorizacin y
focalizacin los niveles de pobreza, prevalencia de enfermedades diarreicas
agudas (EDAs) en los centros poblados que carece de acceso al servicio de
agua potable y disposicin sanitaria de excretas y aguas residuales, con la
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 8 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
finalidad de revertir esta situacin de vulnerabilidad y mejorar las condiciones de
vida de la poblacin.
En el marco de la intervencin del MVCS a travs del PNSR, conforme a los
artculos 1 y 2 de la Resolucin Ministerial N 161-2012-VIVIENDA, se ha
programado desarrollar proyectos de inversin pblica para la ejecucin de
obras de agua potable y saneamiento en las localidades priorizadas y
publicadas en la mencionada Resolucin Ministerial en el cual se encuentra la
localidad de Villa Ancayo del Distrito de Pampa Hermosa, Provincia de Satipo,
Regin Junn.
1.3.2. Antecedentes del proyecto
El presente proyecto corresponde al Estudio Definitivo de las Obras de
Mejoramiento y ampliacin del servicio de agua potable e instalacin del
servicio de disposicin sanitaria excretas en el centro poblado Villa Ancayo, el
cual es un estudio integral que plantea solucionar los problemas de
Abastecimiento de Agua Potable y Saneamiento de esta localidad.
La poblacin de la localidad de Villa Ancayo, viene sufriendo muchas
enfermedades de origen hdrico, debido al consumo de agua que no se
encuentran en condiciones ptimas para el consumo humano, adems, si bien
es cierto poseen continuidad del servicio pero de calidad regular, la cual no llega
con la presin suficiente y necesaria, por tanto el sistema existente no es
ptimo, los pobladores de la localidad a travs de sus autoridades han venido
realizando las gestiones a distintas instituciones pblicas y privadas, con el fin
de solucionar este problema que aqueja gravemente a esta poblacin.
Actualmente los pobladores de la localidad de Villa Ancayo se abastecen de
agua que proviene de un sistema por gravedad sin tratamiento (SGST),
acarreando agua de manantiales y acequias aledaas a las viviendas,
empleando generalmente balde y galoneras que no garantizan la salubridad, ni
tampoco las medidas adecuadas para el almacenamiento, manipulacin y uso
del agua, la fuente principal de abastecimiento de agua proviene de tres
manantiales ubicados en terreno comunal. En cuanto al saneamiento, no se
cuenta con un adecuado sistema, la poblacin en su mayora realiza sus
necesidades fisiolgicas a campo abierto, lo que favorece la proliferacin de
patologas concomitantes esta conducta.
Los intentos anteriores de solucin al problema se dieron en el ao 2005, donde
la municipalidad distrital de Pampa Hermosa ejecuto el sistema de agua
emtubada existente con mano de obra no calificada, este sietema sistema
consta de una captacin de concreto simple artesanal y precario en mal estado
de conservacin, lnea de conduccin de PVC de 1 de dimetro, reservorio
apoyado de concreto armado de 5.00 m3, lnea de aduccin, un pase areo de
82.00 m que cruza el Rio Pampa Hermosa, el mismo que actualmente se
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 9 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
encuentra interrumpido y redes de distribucin de PVC de 1dimetro, las
conexiones existentes no cuentan con cajas de pase habindose realizado
directamente de las redes con conexiones artesanales y precarios que en
muchos casos ya no cuentan con el grifo (cao ) por lo que el agua se pierde
durante todo el da, causando el desabastecimiento en algunas viviendas. El
sistema existente no renen las condiciones tcnicas mnimas segn lo
especificado en las normas del RNE.
El presente proyecto contempla Mejoramiento y ampliacin del servicio de agua
potable e instalacin del servicio de disposicin sanitaria excretas en el centro
poblado Villa Ancayo, considerando adems un componente de capacitacin
tcnica y humana, con la finalidad de mejorar la calidad de vida de los
pobladores de dicha localidad, disminuyendo las tasas de morbilidad y
mortalidad a niveles aceptables y con tendencia a disminuir por debajo del
promedio nacional, logrando el desarrollo integral de la sociedad.
1.4. Objetivos
1.4.1. Objetivo del proyecto
Como proyecto el fin que se persigue es DISMINUIR LOS CASOS DE
ENFERMEDADES DE ORIGEN HDRICO EN LA POBLACIN DE LA
LOCALIDAD DE VILLA ANCAYO, y mejorar su calidad de vida en el marco de
desarrollo local y regional, con horizonte temporal 2034.
1.4.2. Objetivo general
Como objetivo general se trata de mejorar la calidad del servicio que
actualmente se brinda a la localidad de Villa Ancayo, optimizando el sistema de
abastecimiento de agua potable y saneamiento, con el incremento de la
cobertura y la disminucin de los desperdicios de agua en las instalaciones
intradomiciliarias.
1.4.3. Objetivo especfico
Desde el punto de vista del presente documento que forma parte del Expediente
Tcnico del Proyecto, se trata de presentar la informacin tcnica, en
descripcin, especificaciones, grficos y planos para una buena ejecucin de
obra.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 10 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
1.5. Propietario de la obra
El propietario de la Obra es el PNSR, que luego transferira a la Municipalidad
Distrital de Pampa Hermosa y esta a la JASS de esta localidad.
El propietario final de la obra ser la poblacin beneficiaria de la infraestructura
de servicios de agua potable y saneamiento proyectados.
La Junta Administradora de los Servicios de Saneamiento (JASS) es la que se
encuentra debidamente inscrita y reconocida por la Municipalidad Distrital de
Pampa Hermosa, con el compromiso de asumir la responsabilidad de
administrar, operar y mantener el servicio proyectado.
El financiamiento de los costos de administracin, operacin y mantenimiento,
sern cubiertos con las cuotas que pagarn los usuarios por cada uno de los
servicios prestados, cubriendo stos satisfactoriamente dichos costos.
1.6. Caractersticas generales de la localidad
1.6.1. Acceso a la localidad
El acceso a la localidad de Villa Ancayo tomando como punto de partida la
ciudad de lima, se hace a travs de una va asfaltada hasta la localidad de
Satipo, para luego continuar por una carretera afirmada en regular estado
estado hasta llegar a Villa Ancayo; el cuadro a continuacin nos describe el
acceso:
Cuadro 1. Vas de Acceso hacia la localidad de Villa Ancayo
TRAMO TIPO DE
CAMINO
MEDIO DE
TRANSPORTE
DURACION
DE VIAJE
(min)
DISTANCIA
(km)
COSTO
DE VIAJE
Lima La
Oroya Asfaltado
Buses, Auto,
camionetas 04 h 00 min 185.00
Bus: De
56.00 a
65.00
La Oroya
La Merced Asfaltado
Buses, Auto,
Camionetas 03 h 00 min 134.00
La Merced
Satipo Asfaltado
Buses, Auto,
Camionetas 03 h 00 min 113.00
Satipo San
Pedro Asfaltada Auto, combis 00 h 20 min 15.00
Auto: De
S/. 4.00
S/. 5.00
Combi:
S/. 3.00
San Pedro
Desvi Villa
Ancayo
Afirmado Camioneta,
combis, autos. 00 h 15 min 4.00 El pasaje
S/. 2.00 a
S/. 3.00
Desvio Villa
Ancayo - Villa
Ancayo
Trocha y
puente
peatonal
Camioneta,
combis, autos. 00 h 5 min 0.40
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 11 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Elaboracin: Consorcio Consultor Rural N03
Del cuadro anterior permite conocer las vas de acceso ms frecuentes para
llegar a la localidad a intervenir
Imagen 2. Imagen de acceso a la localidad
Elaboracin: Consorcio Consultor Rural N03
1.6.2. Poblacin y vivienda
La poblacin actual total de la localidad de Villa Ancayo, est compuesta por
234 habitantes. Siendo la tasa de crecimiento poblacional utilizada en el
proyecto de 1.65% anual. (Tasa correspondiente a la localidad de Unin
Progreso Ancayo)
De la informacin recopilada en las visitas de campo y las encuestas realizadas,
se tiene 48 lotes, de los cuales 44 son viviendas habitadas y 4 instituciones
pblicas.
Los locales publicos que seran beneficiados por el proyecto seran: I.E. N
31945, PRONOI, iglesia evangelica, local comunal.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 12 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Cuadro 2. Poblacin y distribucin de lotes
Localidad Habitantes
N
de
viviendas
N de
Instituciones
Pblicas
Villa Ancayo 234 44 4
Total 234 44 4
Elaboracin: Consorcio Consultor Rural N03
1.6.3. Caractersticas de servicios existentes
1.6.3.1. Energa elctrica
No todas las viviendas de la localidad de Villa Ancayo cuentan con servicio de
energa elctrica. El 60% de las familias encuestadas no cuenta con electricidad
en sus hogares, utilizando velas y/o linternas a pilas para el alumbrado
domiciliario.
1.6.3.2. Abastecimiento de agua
Segn los datos de la encuesta Socioeconmica aplicada a un grupo muestral
de la poblacin, se puede apreciar que el 30.8% de encuestados tiene conexin
de red entubada intra-domiciliaria, la misma que se encuentra deteriorada y; el
69.2% no tiene conexin intra-domiciliaria de la red de agua, por lo que tienen
que recurrir a una fuente de agua ms cercana a su vivienda para que pueda
consumir y realizar sus actividades necesarias. La poblacin adulta, senil y la
poblacin joven (jvenes, adultos adolescentes y nios) son los que realizan
esta actividad diariamente para contar con este lquido elemento indispensable
para nuestra vida.
Cuadro 3. Fuente de abastecimiento
ABASTECIMIENTO
DE AGUA ABS. %
CON CONEXIN 08 30.8%
SIN CONEXIN 18 69.2%
TOTAL 26 100.0%
Fuente: Encuesta socioeconmica, setiembre 2013
Elaboracin: Consorcio Consultor Rural N 03
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 13 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
1.6.3.3. Saneamiento
El 78.3% las familias no cuentan con ningn tipo de sistema de eliminacin de
excretas, por lo que emplean el campo abierto para defecar, sin embargo se
pudo observar que el 21.7% de las familias han implementado pozos ciegos, los
cuales segn refieren fueron construidos por ellos mismos, sin asistencia
tcnica para su construccin, habindolos ubicado aproximadamente a ms de
4 metros de distancia de la vivienda.
1.6.3.4. Medios de comunicacin
Se tiene que en la localidad de Villa Ancayo algunas radios son sintonizadas, no
contndose con buen alcance en la transmisin (Radio Primavera, Radio
Programas del Per, Radio Maran).
No existe acceso a seal televisiva. La seal de telefona celular Claro es dbil,
por lo que se debe buscar captarla desplazndose por la zona cntrica.
1.6.3.5. Centros educativos
A nivel educativo la poblacin en edad escolar recibe educacin en los
diferentes niveles como: nivel inicial y Primaria.
A seguir se presentan las organizaciones sociales en el rea de estudio:
Institucin educativa N Villa Ancayo
PRONOI
1.7. Informacin socio-econmica
1.7.1. Educacin
Cuadro 4. POBLACION ESCOLAR
Fuente: Ficha de Institucin Educativa, setiembre 2013
Elaboracin: Consorcio Consultor Rural N 03
Se identific 2 instituciones educativos en el centro poblado de Villa Ancayo,
como podemos observar en el cuadro, el centro poblado cuenta con 1 Institucin
Educativa del nivel Inicial PRONOEI y 1 de nivel primaria, el cual en conjunto
alberga un total de 28 alumnos con 2 docentes.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 14 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
1.7.2. Salud
El centro Poblado Villa Ancayo se encuentra dentro de la jurisdiccin del Puesto
de Salud de Santa Rosita, quien atiende a la poblacin que acude luego de no
poder solucionar sus problemas de salud con el tratamiento de hierbas
medicinales de la zona.
El nivel de complejidad de este establecimiento de Salud es I 3,
correspondindoles realizar atenciones preventivas promocionales y consultas
ambulatorias.
El horario de atencin es de 8:00 a.m. a 2:00p.m. Personal nombrado y
SERUM; y de 2:00 pm a 5:00 p.m. Personal contratado. Las emergencias son
cubiertas durante las 24 horas del da.
Cuadro 5. Personal del Puesto de Salud de Santa Rosita
Fuente: Ficha de Puesto de Salud Santa Rosita localidad, 2013
Elaboracin: Consorcio Consultor Rural N 03
Principales causa de morbilidad:
Analizando los datos obtenidos en el Puesto de Salud Santa Rosita, con
respecto a las principales causas de morbilidad en el Centro Poblado de Villa
Ancayo, tenemos porcentajes altos con respecto a las enfermedades digestivas
y respiratorias que oscilan durante los tres ltimos aos.
Despus de enfermedades respiratorias la segunda causa de enfermedades
ms frecuentes, se ha identificado las de origen hdrico con mayor incidencia en
la poblacin la representan las enfermedades gastrointestinales, infecciosas y
parasitarias, las cuales durante el ao 2010 se reportaron en 248 casos, en el
ao 2011 en 236 casos, mostrando una reduccin en el ao 2012 (157 casos).
Otra de las patologas que han mostrado incremento son las relacionadas al
sistema digestivo las que se han incrementado de 133 casos en el 2010 a 120
casos durante el 2012.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 15 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Cuadro 6. Morbilidad General de los ltimos tres aos
Fuente: Puesto de Salud Santa Rosita, setiembre 2013
Elaboracin: Consorcio Consultor Rural N 03
El presente cuadro refleja el comportamiento de la incidencia de las
enfermedades durante el periodo del 2010 al 2012, observndose que las
enfermedades directamente relacionadas al consumo de agua contaminada
como son: diarreicas, parasitosis intestinal, enfermedades de infeccin a la
piel, y las enfermedades respiratorias se mantienen como las principales
causas de morbilidad local.
Las enfermedades diarreicas, registraron en el ao 2010 un porcentaje de
26% y con el mismo porcentaje se registr en el ao 2011; para el ao 2012
varia a un porcentaje de 24.5%. Y la parasitosis intestinal, en este periodo
registro una variacin como para el ao 2010 con el porcentaje de 11%, para
el ao 2011 con un porcentaje de 12%, y para el ao 2012 con un porcentaje
de 10%.
Estos datos nos permiten identificar el problema central que afecta al Centro
Poblado de Villa Ancayo, proponiendo alternativas para combatir y disminuir
estos altos porcentajes de enfermedades de origen hdrico, planteando
capacitaciones y talleres de educacin sanitaria y fortalecimiento de
capacidades, para que la poblacin conozca y practique hbitos saludables
que le permitan mejorar su calidad de vida y evitar las constantes
enfermedades en adultos como en nios que son la poblacin vulnerable de la
zona.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 16 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
2. PROYECCIONES POBLACIONALES, ANLISIS DE OFERTA Y
DEMANDA
2.1. Estudio poblacional
Para el clculo de la tasa de crecimiento poblacional, se tom como informacin
de base los censos del INEI, se aplic el mtodo analtico tipo crecimiento
aritmetico. Este mtodo es representativo de poblaciones rurales que estn en
el inicio de su desarrollo.
Su formulacin es la que se presenta a seguir:
Dnde:
Pf: Poblacin final
Pi: Poblacin inicial
r: Tasa de crecimiento poblacional
t: Variacin de tiempo en aos
2.1.1. Poblacin actual
La localidad de Villa Ancayo, segn el estudio socioeconmico realizado cuenta
con una poblacin total de 234 habitantes, distribuida en 44 viviendas.
Cuadro 7. Poblacin y viviendas
Localidad Habitantes N de
Viviendas
N de
Instituciones
Pblicas
Villa
Ancayo 234 44 4
Fuente: Ficha de empadronamiento, Septiembre
2014
Elaboracin: F.C. Consorcio Consultor Rural N03
2.1.2. Densidad poblacional por vivienda
Los habitantes de la zona de influencia del proyecto se concentran en lotes de
vivienda cada uno de los cuales se considera como un usuario de los servicios
de agua potable y saneamiento. La densidad por vivienda para este proyecto es
de 5.18 hab./viv. de acuerdo al siguiente detalle:
)*1( trPP if
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 17 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Cuadro 8. Densidad Poblacional por vivienda
Fuente: Ficha de empadronamiento, septiembre 2014
Elaboracin: F.C. Consorcio Consultor Rural N03
2.1.3. Tasa de crecimiento
La tasa de crecimiento poblacional a ser utilizada para proyectar la poblacin en
este estudio, se estima a partir de la informacin de los censos nacionales de
poblacin y vivienda correspondiente a los aos 1993 y 2007, del Instituto
Nacional de Estadstica e Informtica (INEI) y del empadronamiento realizado
en la localidad el ao 2014.
Con la informacin obtenida de las antes mencionadas se obtuvo los siguientes
resultados:
Cuadro 9. Tasa de crecimiento
Descripcin Censos Tasa
Anual
Tasa a
utilizar De ndole
2007 1993
DEPARTAMENTO JUNIN 1,225,474 1,035,841 1.21% 1.21% Departamental
PROVINCIA SATIPO 193,872 94,250 5.29% 5.29% Provincial
DISTRITO PAMPA
HERMOSA 7,508 3,543 5.51% 5.51% Distrital
LOCALIDAD VILLA
ANCAYO 213 102 7.77% 7.77%
Centro
Poblado
Fuente: Censos INEI
Elaboracin: F.C. Consorcio Consultor Rural N03
Las tasas de crecimiento obtenidas a excepcin de la departamental (1.21%)
son muy altas para ser consideradas en un proyecto de saneamiento rural. De
esta manera la tasa de crecimiento a utilizar en el proyecto ser la de una
localidad cercana (en esta caso UNION PROGRESO ANCAYO) que utilizando
el censo del 2007 y la poblacin empadronada el 2013, se obtiene una tasa de
crecimiento de 1.65%.
Descripcin Cantidad
Poblacin 234
Viviendas 44
Densidad h/v 5.32
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 18 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Cuadro 10. Tasa de crecimiento asumida
Descripcin Censos Tasa
Anual 2007 2013
LOCALIDAD
UNION
PROGRESO
ANCAYO
198 275 1.65%
Fuente: Censos INEI
Elaboracin: F.C. Consorcio Consultor Rural N03
2.1.4. Poblacin y viviendas futuras
Aplicando la tasa de crecimiento poblacional adoptada para el proyecto (1.65%),
se han efectuado las proyecciones de poblacin para cada ao durante el
perodo horizonte de proyecto.
Cuadro 11. Proyeccin de la poblacin
Periodo Ao Poblacin
Total
0 2014 234
1 2015 238
2 2016 242
3 2017 246
4 2018 249
5 2019 253
6 2020 257
7 2021 261
8 2022 265
9 2023 269
10 2024 273
11 2025 276
12 2026 280
13 2027 284
14 2028 288
15 2029 292
16 2030 296
17 2031 300
18 2032 303
19 2033 307
20 2034 311
Elaboracin: F.C. Consorcio Consultor Rural N03
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 19 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Segn el cuadro anterior, la poblacin al ao 20 asciende a 311 habitantes.
Dicho valor es el que se emplear para el proyecto del sistema de agua Potable.
2.2. Demanda proyectada de agua potable
Considerando que actualmente el 60% de la poblacin de esta localidad dispone
de servicios de agua potable mediante conexiones domiciliarias artesanales sin
tratamiento; se ha procedido a estimar los niveles de consumo de agua de las
familias que no cuentan con el servicio a nivel domiciliario y que realizan otras
formas de abastecimiento (en este caso gran parte de la poblacin realizan el
acarreo de la acequia, quebradas y manantiales), utilizando la informacin de
los pobladores en las encuestas realizadas respecto al nmero de viajes para
acarrear agua.
Todas las viviendas habitadas de la localidad sern beneficiadas con el servicio,
es decir las 44 viviendas (234 hab.) contaran con agua potable a nivel de
conexiones domiciliarias
De acuerdo a las caractersticas demogrficas, culturales, y condiciones
tcnicas se propone la implementacin de un sistema de agua potable a travs
de redes, y sistema de saneamiento domiciliario.
Para el proyecto se ha considerado un valor de consumo promedio de 120
l/hab./da, segn recomendacin de PNSR para las localidades ubicadas en la
selva peruana.
Para determinar el volumen en los reservorios se deber considerar el 20% del
caudal promedio diario (segn recomendaciones del PNSR). Esto con el fin de
regular consumos de la poblacin durante el da.
Por ltimo, a efectos de diseo y tambin basado en recomendaciones
establecidas en la gua K1 elaborada por PNSR, se asume un volumen de
prdidas fsicas de 25% adicional al caudal medio diario a fin de proyecto.
A continuacin se presentan los parmetros utilizados para calcular la demanda
de agua para el proyecto:
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA,
- SATIPO - JUNN
Pgina 20 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Cuadro 12. Parmetros para el clculo de la demanda de agua
Detalle Sin
Proyecto Con
Proyecto
Poblacin actual (hab) 234 234
Poblacin con servicio de agua potable 0 234
N de Viviendas total 44 44
N de Viviendas con conexin domiciliaria
0 44
N de Viviendas sin conexin domiciliaria
44 0
N Usuarios Pblicos Conectados 4 4
Densidad poblacional (hab/viv) 5.32 5.32
Dotacin domiciliaria (l/hab/da) 120.0 120.0
Dotacin de pob.no conectada (l/hab/d) 120.0
Dotacin Estatal (lt/da) 1,546.4 1,546.4
Cobertura Agua Potable% 0.0% 100.0%
Rendimiento de las captaciones (l/s) 0.22 0.85
% de Regulacin 9% 20%
Reservorio (M3) 5 11.00
Demanda mxima diaria k1 1.3
Demanda mxima horaria k2 2.0
Nmero de alumnos de inicial y primaria 12 12
Nmero de alumnos de secundaria 6 6
Tasa de crecimiento poblacional 1.65% 1.65%
N de horas de servicio 24 24
Elaboracin: F.C. Consorcio Consultor Rural N03
Con la ejecucin del proyecto se plantea generar una cobertura del 100% de la
poblacin al servicio de agua potable. Se consider un consumo medio de la
poblacin de 120 L/hab/da.
Para el sistema de agua potable propuesto se consider realizar dos sistemas
para darle solucin y beneficiar a todos las familias:
Sistema N01: Denominado Sector Central, que consta de 3
captaciones tipo manantial de ladera, una lnea de conduccin de ,
un reservorio apoyado tipo circular de V=9.00m3, 2428.44 m redes de
distribucin, un pase areo de 71 m que brindaran el servicio a 36
viviendas y 4 instituciones pblicas.
Sistema N02: Denominado Sector N02, Se construir una obra de
arte especial que consiste en una estructura de captacin seguido de un
volumen de almacenamiento de V=2.00 m3, redes de distribucin que
brindaran el servicio a 8 viviendas mediante conexiones domiciliarias
A continuacin se presentan los cuadros que resumen los clculos efectuados
para la estimacin de demandas y volumen de almacenamiento requerido por la
poblacin.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO
VILLA ANCAYO, DISTRITO PAMPA HERMOSA - SATIPO - JUNN
Pgina 21 de 81 MEMORIA DESCRIPTIVA Y JUSTIFICATIVA
Cuadro 13. Demanda proyectada General de la localidad de Villa Ancayo
Elaboracin: F.C. Consorcio Consultor Rural N03
Consum
o
Caudal
prome
Demand
a
Antiguas Nuevas Total lt/da Viv.lt/da
est.total lt/seg m3/ao lt/da lt/seg m3/ao lt/seg lt/seg
0 2014 234 0% 0 0 0 0 4 4 0 1,546 1,546 0.018 564 50% 3,093 0.04 1,129 0.05 0.07 0.62
1 2015 238 100% 238 44 1 45 4 49 28,560 1,546 30,106 0.348 10,989 25% 40,142 0.46 14,652 0.60 0.93 8.03
2 2016 242 100% 242 44 2 46 4 50 29,040 1,546 30,586 0.354 11,164 25% 40,782 0.47 14,885 0.61 0.94 8.16
3 2017 246 100% 246 44 2 46 4 50 29,520 1,546 31,066 0.360 11,339 25% 41,422 0.48 15,119 0.62 0.96 8.28
4 2018 249 100% 249 44 3 47 4 51 29,880 1,546 31,426 0.364 11,471 25% 41,902 0.48 15,294 0.63 0.97 8.38
5 2019 253 100% 253 44 4 48 4 52 30,360 1,546 31,906 0.369 11,646 25% 42,542 0.49 15,528 0.64 0.98 8.51
6 2020 257 100% 257 44 4 48 4 52 30,840 1,546 32,386 0.375 11,821 25% 43,182 0.50 15,761 0.65 1.00 8.64
7 2021 261 100% 261 44 5 49 4 53 31,320 1,546 32,866 0.380 11,996 25% 43,822 0.51 15,995 0.66 1.01 8.76
8 2022 265 100% 265 44 6 50 4 54 31,800 1,546 33,346 0.386 12,171 25% 44,462 0.51 16,229 0.67 1.03 8.89
9 2023 269 100% 269 44 7 51 4 55 32,280 1,546 33,826 0.392 12,347 25% 45,102 0.52 16,462 0.68 1.04 9.02
10 2024 273 100% 273 44 7 51 4 55 32,760 1,546 34,306 0.397 12,522 25% 45,742 0.53 16,696 0.69 1.06 9.15
11 2025 276 100% 276 44 8 52 4 56 33,120 1,546 34,666 0.401 12,653 25% 46,222 0.53 16,871 0.70 1.07 9.24
12 2026 280 100% 280 44 9 53 4 57 33,600 1,546 35,146 0.407 12,828 25% 46,862 0.54 17,105 0.71 1.08 9.37
13 2027 284 100% 284 44 9 53 4 57 34,080 1,546 35,626 0.412 13,004 25% 47,502 0.55 17,338 0.71 1.10 9.50
14 2028 288 100% 288 44 10 54 4 58 34,560 1,546 36,106 0.418 13,179 25% 48,142 0.56 17,572 0.72 1.11 9.63
15 2029 292 100% 292 44 11 55 4 59 35,040 1,546 36,586 0.423 13,354 25% 48,782 0.56 17,805 0.73 1.13 9.76
16 2030 296 100% 296 44 12 56 4 60 35,520 1,546 37,066 0.429 13,529 25% 49,422 0.57 18,039 0.74 1.14 9.88
17 2031 300 100% 300 44 12 56 4 60 36,000 1,546 37,546 0.435 13,704 25% 50,062 0.58 18,273 0.75 1.16 10.01
18 2032 303 100% 303 44 13 57 4 61 36,360 1,546 37,906 0.439 13,836 25% 50,542 0.58 18,448 0.76 1.17 10.11
19 2033 307 100% 307 44 14 58 4 62 36,840 1,546 38,386 0.444 14,011 25% 51,182 0.59 18,681 0.77 1.18 10.24
20 2034 311 100% 311 44 14 58 4 62 37,320 1,546 38,866 0.450 14,186 25% 51,822 0.60 18,915 0.78 1.20 10.36
Qmd Poblacin
Servida
Qmh Consumo Total Total N
Conexiones
Prdidas
(%) Ao
Otras
ConexionesPeriodo
Poblacin
Total
Cobertura
%
Volumen de
Almacena-
miento
(m3/dia)
N de viviendas Servidas
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO
VILLA ANCAYO, DISTRITO PAMPA HERMOSA - SATIPO - JUNN
Pgina 22 de 81 MEMORIA DESCRIPTIVA Y JUSTIFICATIVA
Consum
o
Caudal
prome
Demand
a
Antiguas Nuevas Total lt/da Viv.lt/da
est.total lt/seg m3/ao lt/da lt/seg m3/ao lt/seg lt/seg
0 2014 192 0% 0 0 0 0 4 4 0 1,546 1,546 0.018 564 50% 3,093 0.04 1,129 0.05 0.07 0.62
1 2015 195 100% 195 0 0 0 4 4 23,400 1,546 24,946 0.289 9,105 25% 33,262 0.38 12,141 0.50 0.77 6.65
2 2016 198 100% 198 35 2 37 4 41 23,760 1,546 25,306 0.293 9,237 25% 33,742 0.39 12,316 0.51 0.78 6.75
3 2017 202 100% 202 35 3 38 4 42 24,240 1,546 25,786 0.298 9,412 25% 34,382 0.40 12,549 0.52 0.80 6.88
4 2018 205 100% 205 35 4 39 4 43 24,600 1,546 26,146 0.303 9,543 25% 34,862 0.40 12,725 0.52 0.81 6.97
5 2019 208 100% 208 35 4 39 4 43 24,960 1,546 26,506 0.307 9,675 25% 35,342 0.41 12,900 0.53 0.82 7.07
6 2020 211 100% 211 35 5 40 4 44 25,320 1,546 26,866 0.311 9,806 25% 35,822 0.41 13,075 0.54 0.83 7.16
7 2021 214 100% 214 35 5 40 4 44 25,680 1,546 27,226 0.315 9,938 25% 36,302 0.42 13,250 0.55 0.84 7.26
8 2022 217 100% 217 35 6 41 4 45 26,040 1,546 27,586 0.319 10,069 25% 36,782 0.43 13,425 0.55 0.85 7.36
9 2023 221 100% 221 35 7 42 4 46 26,520 1,546 28,066 0.325 10,244 25% 37,422 0.43 13,659 0.56 0.87 7.48
10 2024 224 100% 224 35 7 42 4 46 26,880 1,546 28,426 0.329 10,376 25% 37,902 0.44 13,834 0.57 0.88 7.58
11 2025 227 100% 227 35 8 43 4 47 27,240 1,546 28,786 0.333 10,507 25% 38,382 0.44 14,009 0.58 0.89 7.68
12 2026 230 100% 230 35 8 43 4 47 27,600 1,546 29,146 0.337 10,638 25% 38,862 0.45 14,185 0.58 0.90 7.77
13 2027 233 100% 233 35 9 44 4 48 27,960 1,546 29,506 0.342 10,770 25% 39,342 0.46 14,360 0.59 0.91 7.87
14 2028 236 100% 236 35 9 44 4 48 28,320 1,546 29,866 0.346 10,901 25% 39,822 0.46 14,535 0.60 0.92 7.96
15 2029 240 100% 240 35 10 45 4 49 28,800 1,546 30,346 0.351 11,076 25% 40,462 0.47 14,769 0.61 0.94 8.09
16 2030 243 100% 243 35 11 46 4 50 29,160 1,546 30,706 0.355 11,208 25% 40,942 0.47 14,944 0.62 0.95 8.19
17 2031 246 100% 246 35 11 46 4 50 29,520 1,546 31,066 0.360 11,339 25% 41,422 0.48 15,119 0.62 0.96 8.28
18 2032 249 100% 249 35 12 47 4 51 29,880 1,546 31,426 0.364 11,471 25% 41,902 0.48 15,294 0.63 0.97 8.38
19 2033 252 100% 252 35 12 47 4 51 30,240 1,546 31,786 0.368 11,602 25% 42,382 0.49 15,469 0.64 0.98 8.48
20 2034 255 100% 255 35 13 48 4 52 30,600 1,546 32,146 0.372 11,733 25% 42,862 0.50 15,645 0.64 0.99 8.57
Periodo AoPoblacin
Total
Cobertura
%
Poblacin
Servida
N de viviendas ServidasOtras
Conexiones
Total N
Conexiones
Consumo Total Prdidas
(%)
Qmd Qmh Volumen de
Almacena-
miento
(m3/dia)
Cuadro 14. Demanda proyectada para el sistema de agua potable Sector Central
Elaboracin: F.C. Consorcio Consultor Rural N03
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO
VILLA ANCAYO, DISTRITO PAMPA HERMOSA - SATIPO - JUNN
Pgina 23 de 81 MEMORIA DESCRIPTIVA Y JUSTIFICATIVA
Consum
o
Caudal
prome
Demand
a
Antiguas Nuevas Total lt/da Viv.lt/da
est.total lt/seg m3/ao lt/da lt/seg m3/ao lt/seg lt/seg
0 2014 42 0% 0 0 0 0 0 0 0 0 0 0.000 0 50% 0 0.00 0 0.00 0.00 0.00
1 2015 43 100% 43 8 0 8 0 8 5,160 0 5,160 0.060 1,883 25% 6,880 0.08 2,511 0.10 0.16 1.38
2 2016 43 100% 43 8 0 8 0 8 5,160 0 5,160 0.060 1,883 25% 6,880 0.08 2,511 0.10 0.16 1.38
3 2017 44 100% 44 8 0 8 0 8 5,280 0 5,280 0.061 1,927 25% 7,040 0.08 2,570 0.11 0.16 1.41
4 2018 45 100% 45 8 0 8 0 8 5,400 0 5,400 0.063 1,971 25% 7,200 0.08 2,628 0.11 0.17 1.44
5 2019 45 100% 45 8 0 8 0 8 5,400 0 5,400 0.063 1,971 25% 7,200 0.08 2,628 0.11 0.17 1.44
6 2020 46 100% 46 8 1 9 0 9 5,520 0 5,520 0.064 2,015 25% 7,360 0.09 2,686 0.11 0.17 1.47
7 2021 47 100% 47 8 1 9 0 9 5,640 0 5,640 0.065 2,059 25% 7,520 0.09 2,745 0.11 0.17 1.50
8 2022 48 100% 48 8 1 9 0 9 5,760 0 5,760 0.067 2,102 25% 7,680 0.09 2,803 0.12 0.18 1.54
9 2023 48 100% 48 8 1 9 0 9 5,760 0 5,760 0.067 2,102 25% 7,680 0.09 2,803 0.12 0.18 1.54
10 2024 49 100% 49 8 1 9 0 9 5,880 0 5,880 0.068 2,146 25% 7,840 0.09 2,862 0.12 0.18 1.57
11 2025 50 100% 50 8 1 9 0 9 6,000 0 6,000 0.069 2,190 25% 8,000 0.09 2,920 0.12 0.19 1.60
12 2026 50 100% 50 8 1 9 0 9 6,000 0 6,000 0.069 2,190 25% 8,000 0.09 2,920 0.12 0.19 1.60
13 2027 51 100% 51 8 2 10 0 10 6,120 0 6,120 0.071 2,234 25% 8,160 0.09 2,978 0.12 0.19 1.63
14 2028 52 100% 52 8 2 10 0 10 6,240 0 6,240 0.072 2,278 25% 8,320 0.10 3,037 0.13 0.19 1.66
15 2029 52 100% 52 8 2 10 0 10 6,240 0 6,240 0.072 2,278 25% 8,320 0.10 3,037 0.13 0.19 1.66
16 2030 53 100% 53 8 2 10 0 10 6,360 0 6,360 0.074 2,321 25% 8,480 0.10 3,095 0.13 0.20 1.70
17 2031 54 100% 54 8 2 10 0 10 6,480 0 6,480 0.075 2,365 25% 8,640 0.10 3,154 0.13 0.20 1.73
18 2032 54 100% 54 8 2 10 0 10 6,480 0 6,480 0.075 2,365 25% 8,640 0.10 3,154 0.13 0.20 1.73
19 2033 55 100% 55 8 2 10 0 10 6,600 0 6,600 0.076 2,409 25% 8,800 0.10 3,212 0.13 0.20 1.76
20 2034 56 100% 56 8 3 11 0 11 6,720 0 6,720 0.078 2,453 25% 8,960 0.10 3,270 0.13 0.21 1.79
Volumen de
Almacena-
miento
(m3/dia)
Periodo AoPoblacin
Total
Cobertura
%
Poblacin
Servida
N de viviendas ServidasOtras
Conexiones
Total N
Conexiones
Consumo Total Prdidas
(%)
Qmd Qmh
Cuadro 15. Demanda proyectada para el sistema de agua potable Sector N02
Elaboracin: F.C. Consorcio Consultor Rural N03
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 24 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
2.3. Generacin proyectada de aguas residuales
La localidad de Villa Ancayo no cuenta con un adecuado sistema de disposicin
sanitaria de excretas, los pobladores utilizan pozos o silos empricos, los cuales
se encuentran en mal estado. Gran parte de las familias realizan sus
necesidades fisiolgicas a campo abierto, lo que favorece la proliferacin de
patologas gastrointestinales relacionadas a esta conducta.
Para los datos de partida de clculo de demandas se han utilizado los siguientes
valores de consumo, segn informacin proporcionada por la Gua para la
Elaboracin de Proyectos de Agua Potable y Saneamiento del Programa
Nacional de Saneamiento Rural (Anexo K1):
Se proyectaran UBS tipo arrastre hidrulico para todas las viviendas
beneficiadas, de esta manera se construirn 44 UBS AH para viviendas , 2 UBS
AH para instituciones pblicas y 2 UBS AH para instituciones educativas.
Dado que para la deposicin de excretas de los sistemas generales ser del tipo
UBS AH, segn el cuadro anterior el consumo de diseo ser de 120 litros por
habitante, considerando la zona geogrfica de Selva
En el caso de instituciones educativas el consumo de diseo ser de 15 litros
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 25 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
por alumno al da.
En cuanto al consumo social, en el caso de locales, organizaciones o
instituciones que tengan concurrencia de poblacin o presten atencin al pblico
la dotacin a usar ser la dotacin estipulada por vivienda segn la gua
mencionada (Anexo K1).
El caudal de contribucin al alcantarillado considerado es del 80% del caudal de
agua potable consumida segn el Reglamento Nacional de Edificaciones, por lo
tanto el coeficiente de de retorno utilizado es de 0.8.
Cuadro 16. Demanda proyectada para el sistema de saneamiento
Periodo Ao Poblacin
Total Cobertura
% Poblacin Servida
N de UBS Total N
UBS Viviendas UBS-AH
Instituciones UBS-AH
0 2014 234 0% 0 0 0 0
1 2015 238 100% 238 45 4 49
2 2016 242 100% 242 46 4 50
3 2017 246 100% 246 46 4 50
4 2018 249 100% 249 47 4 51
5 2019 253 100% 253 48 4 52
6 2020 257 100% 257 48 4 52
7 2021 261 100% 261 49 4 53
8 2022 265 100% 265 50 4 54
9 2023 269 100% 269 51 4 55
10 2024 273 100% 273 51 4 55
11 2025 276 100% 276 52 4 56
12 2026 280 100% 280 53 4 57
13 2027 284 100% 284 53 4 57
14 2028 288 100% 288 54 4 58
15 2029 292 100% 292 55 4 59
16 2030 296 100% 296 56 4 60
17 2031 300 100% 300 56 4 60
18 2032 303 100% 303 57 4 61
19 2033 307 100% 307 58 4 62
20 2034 311 100% 311 58 4 62
Elaboracin: F.C. Consorcio Consultor Rural N03
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 26 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
2.4. Anlisis de la oferta
2.4.1. Sistema de agua potable
2.4.1.1. Diagnstico del servicio
La localidad de Villa Ancayo se abastece mediante un sistema de
gravedad sin tratamiento (SGST)
Se caracterizan por tener 02 sectores de viviendas. Las familias del
sector Central consumen agua entubada del sistema existente, mientras
que las familias del sector 2 no cuentan con ningn sistema de agua.
En cuanto al sistema de agua entubada existente en el sector 1: fue
construido en el ao 2005, por la Municipalidad Distrital de Pampa
Hermosa con el aporte de la mano de obra no calificada de la poblacin
beneficiaria, en esa poca la Municipalidad Distrital, no estaba
enmarcado en las polticas del sistema nacional de inversin pblica
El servicio de agua es continuo durante 24 horas al da.
2.4.1.2. Diagnstico de la infraestructura existente
a) Captacin
La caja de la captacin, es una proteccin de afloramiento del manantial, tiene
el agua estancada, causando la proliferacin de mosquitos e insectos. Tambin
se observa que el agua ingresa con material de arrastr, la tapa es de concreto
simple y no cumple con la condiciones sanitarias para este tipo de obras.
La captacin no cuenta con caja de vlvulas, la lnea de conduccin sale
directamente desde la caja y se encuentra expuesto a la intemperie.
La estructura no cumple los requisitos mnimos establecidos en el RNE, ya que
fue construido sin direccin tcnica, por lo que no garantiza las correctas
prcticas constructivas, lo que se traduce en el mal estado en que se encuentra.
Se observ que todo el agua que afloraba de la fuente era captada en la
estructura por que no presentaba perdida, de esta manera se aforo en la llegada
al reservorio obtenindose un caudal aforado de 0.22 l/seg.
Desde el punto de vista tcnico la fuente de agua existente con la que cuenta el
centro poblado de Villa Ancayo son provenientes de los ojos de agua
denominados manantiales de ladera.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 27 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Imagen 3. Captacion existente en Villa Ancayo
b) Lnea de conduccin
Existe en la actualidad una lnea de conduccin de 12.00 ml de tubera, de
dimetro PVC DE 1 que sale desde la captacin existente hasta el reservorio.
Las tuberas segn las inspecciones oculares realizadas estn expuestas a la
intemperie, en todo el tramo, siendo vulnerable a impactos por el trnsito de
personas y animales, y presentan reparaciones en varios tramos.
Imagen 4. Lnea de conduccin existente
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 28 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
c) Reservorio
La estructura de almacenamiento tiene las siguientes caractersticas:
Tipo: Apoyado
Estructura: concreto armado
Volumen de almacenamiento: 5.00m3
Los accesorios son de PVC y no cuentan con tapa sanitaria.
En la inspeccin ocular realizada, se determin que se encuentra en mal estado
de conservacin. Se verifico que los muros, losas de concreto y cmara de
vlvulas presentaban fisuras, adems de moho y musgo en su superficie. La
losa del reservorio presenta corrosin en el acero. Adems presenta descascara
miento y resquebrajamiento en sus aristas. Actualmente el reservorio est fuera
de servicio.
La estructura no cumple los requisitos mnimos establecidos en el RNE, ya que
fue construido sin direccin tcnica, por lo que no garantiza las correctas
prcticas constructivas, lo que se traduce en el mal estado en que se encuentra.
Imagen 5. Reservorio Existente
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 29 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
d) La lnea de aduccin
Existe en la actualidad una lnea de aduccin de 205.00 ml de tubera, de
dimetro PVC de 1 que sale desde el reservorio existente hasta la carretera, se
encuentra en mal estado de conservacin, actualmente se encuentra
interrumpida en dos puntos (En la carretera hacia mariposa, y el tramo del
puente peatonal).Las tuberas segn las inspecciones oculares realizadas estn
expuestas, y presentan reparaciones en varios tramos.
Imagen 6. Lnea de aduccin
e) Redes de Distribucin existentes
Existe en la actualidad una red de distribucin de 288.00 ml de tubera, de
dimetro PVC de 3/4 que sale desde el reservorio existente hasta la carretera,
se encuentra en mal estado de conservacin, actualmente se encuentra
interrumpida al ingreso del puente peatonal. Las tuberas segn las
inspecciones oculares realizadas estn expuestas, y presentan reparaciones en
varios tramos.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 30 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Imagen 7. Lnea de aduccin y red de distribucin
f) Instalaciones domiciliarias
La localidad de Villa Ancayo cuenta con 18 conexiones domiciliarias artesanales
de agua, que los beneficiarios han construido usando tuberas PVC, los mismos
que se encuentran expuestos, y en deficiente estado de conservacin, y no
cumple los requisitos mnimos establecidos en el RNE, ya que fue construido
sin direccin tcnica, por lo que no garantiza las correctas prcticas
constructivas, lo que se traduce en el mal estado en que se encuentra.
Imagen 8. Instalaciones intradomiciliarias
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 31 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Imagen 9. Esquema del sistema existente
g) Sistema de abastecimiento no convencional
El sistema no convencional lo constituyen, los sistemas que no cuentan
con los componentes convencionales como la captacin, lneas de conduccin,
distribucin, reservorios, etc., por lo que la poblacin se abastece de diversas
fuentes como son agua empozada, ros, acequias, manantiales, etc.
En el Centro Poblado Villa Ancayo aquellas familias que no se abastecen
mediante conexiones domiciliarias o de piletas pblicas usan otros sistemas no
convencionales como son:
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 32 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
2.4.2. Sistema de saneamiento
2.4.2.1. Diagnstico del servicio
El Centro Poblado Villa Ancayo no dispone de servicio de disposicin sanitaria
de excretas, slo algunos pobladores han construido silos artesanales sin
consideraciones tcnicas que se encuentran muy deterioradas, presentan mal
olor debido a que no poseen un sistema de ventilacin adecuado, y son un foco
infeccioso para los pobladores. La mayor parte de poblacin al no disponer de
un medio adecuado para evacuar las excretas, hace uso de los silos en
condiciones precarias o del espacio libre de los terrenos o las orillas de las
fuentes de agua existentes.
Los silos artesanales, en su mayora han sido construidos sin direccin tcnica,
por los propios pobladores, empleando material de la zona.
En cuanto la operacin y mantenimiento, los beneficiarios solo refieren que al
llenarse el silo, proceden al cierre del mismo.
2.4.2.2. Cobertura y calidad del servicio segn las opciones tcnicas utilizadas
De acuerdo a la encuesta aplicada tenemos que el 76.9% de los pobladores
tienen pozo ciego o letrina y el 23.1% no tiene y utiliza el campo para realizar
sus necesidades. Cabe indicar que la referencia pozo ciego o letrina, es
identificado por los pobladores como silos artesanales, los cuales no cumplen
con las condiciones tcnicas mnimas para su funcionamiento. Ante esta
situacin se concluye que el servicio con que cuenta actualmente el Centro
Poblado Villa Ancayo es deficiente y de mala calidad.
2.4.2.3. Situacin de la operacin y mantenimiento, costos de operacin y
mantenimiento
Actualmente no existe la operacin ni mantenimiento de los silos existentes,
tanto es as, que stas se inundan cuando llega poca de lluvias,
generando un peligro para las familias especialmente para los nios por lo
que estn ms propensos a contraer enfermedades. Al no disponer de un
servicio sanitario esto trae como consecuencia la contaminacin ambiental
incrementando an ms los focos de infeccin que afectan la salud de la
poblacin.
A continuacin se muestran unas imgenes del aspecto que presentan los silos
artesanales.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 33 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Imagen 10. Silos Artesanales existentes
Imagen 11. Vista de Hoyo donde disponen las excretas
2.5. Balance oferta-demanda
Del balance ofertademanda del sistema de agua potable para todo el horizonte
de evaluacin del proyecto, resulta que el sistema de abastecimiento de agua es
deficiente y no apta para consumo humano.
En cuanto al sistema de saneamiento se cuenta con letrinas artesanales en
psimas condiciones de conservacin de material rustico y sin asistencia tcnica
en su construccin.
Por todo lo anterior se concluye que tanto el sistema de agua corriente como el
de saneamiento son deficitarios.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 34 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
0 0.22 0.05 0.17
1 0.22 0.59 -0.37
2 0.22 0.60 -0.38
3 0.22 0.61 -0.39
4 0.22 0.62 -0.40
5 0.22 0.62 -0.40
6 0.22 0.63 -0.41
7 0.22 0.64 -0.42
8 0.22 0.65 -0.43
9 0.22 0.66 -0.44
10 0.22 0.67 -0.45
11 0.22 0.68 -0.46
12 0.22 0.69 -0.47
13 0.22 0.70 -0.48
14 0.22 0.71 -0.49
15 0.22 0.71 -0.49
16 0.22 0.72 -0.50
17 0.22 0.73 -0.51
18 0.22 0.74 -0.52
19 0.22 0.75 -0.53
20 0.22 0.76 -0.54
Oferta
(l/s)
Demanda
(l/s)
Balance O-
D (l/s)Ao
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Qp
(lp
s)
Aos
BRECHA: Oferta "Sin Proyecto" Vs Demanda "Proyectada"COMPONENTE: Fuente de Abastecimiento (LPS)
DEMANDA
OFERTA
DEFICIT
2.5.1. Sistema de agua potable
2.5.1.1. Balance Oferta-Demanda Fuente de abastecimiento
La fuente actual de abastecimiento de agua de la comunidad de Villa Ancayo es
el manantial Villa Ancayo N01, de acuerdo a lo aforado presenta un caudal de
0.22 L/s.
En el cuadro siguiente se muestra el balance oferta y demanda para la fuente de
abastecimiento tomando en cuenta la demanda que requiere el proyecto.
Cuadro 17. Balance oferta-demanda Fuente de Abastecimiento de agua
Elaboracin: F.C. Consorcio Consultor Rural N03
2.5.1.2. Balance Oferta Demanda de estructura de captacin
La captacin actual abastece de manera continua a la localidad de Villa Ancayo
y fue construida sin criterio tcnico. Esto se refleja en el estado de la estructura
la cual presenta rajadura y filtraciones.
Por lo anterior, para la ejecucin de obra, se proceder con la demolicin total
de la captacion existente, y posterior construccin de las captaciones
propuestas, las cuales estar diseada de acuerdo a normativa y
recomendaciones, en funcin a la demanda del proyecto.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 35 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Cuadro 18. Balance oferta-demanda Estructura de captacin
Elaboracin: F.C. Consorcio Consultor Rural N03
2.5.1.3. Balance Oferta Demanda para la Lnea de Conduccin
La lnea de conduccin instalada para abastecer el sistema actual tiene una
longitud de 12 m PVC SP C-10 de 1, la cual tiene una capacidad mxima de
transporte de 1.95 l/s y se encuentra expuesta en todo su recorrido.
Por lo tanto se concluye que se remover la tubera existente y se instalara una
nueva lnea de conduccin que cumplir con criterios y normas establecido en el
RNE.
Cuadro 19. Balance oferta-demanda Lnea de conduccin
0 0.00 0.05 -0.05
1 0.00 0.60 -0.60
2 0.00 0.61 -0.61
3 0.00 0.62 -0.62
4 0.00 0.63 -0.63
5 0.00 0.64 -0.64
6 0.00 0.65 -0.65
7 0.00 0.66 -0.66
8 0.00 0.67 -0.67
9 0.00 0.68 -0.68
10 0.00 0.69 -0.69
11 0.00 0.70 -0.70
12 0.00 0.71 -0.71
13 0.00 0.71 -0.71
14 0.00 0.72 -0.72
15 0.00 0.73 -0.73
16 0.00 0.74 -0.74
17 0.00 0.75 -0.75
18 0.00 0.76 -0.76
19 0.00 0.77 -0.77
20 0.00 0.78 -0.78
Oferta
(l/s)
Demanda
(l/s)
Balance O-
D (l/s)Ao
0
0
0
0
0
1
1
1
1
1
0 5 10 15 20
m3
Aos
BRECHA: Oferta "Sin Proyecto" Vs Demanda "Proyectada"
COMPONENTE: Linea de conduccion
DEMANDA
OFERTA
DEFICIT
Elaboracin: F.C. Consorcio Consultor Rural N03
0 0.00 0.05 -0.05
1 0.00 0.60 -0.60
2 0.00 0.61 -0.61
3 0.00 0.62 -0.62
4 0.00 0.63 -0.63
5 0.00 0.64 -0.64
6 0.00 0.65 -0.65
7 0.00 0.66 -0.66
8 0.00 0.67 -0.67
9 0.00 0.68 -0.68
10 0.00 0.69 -0.69
11 0.00 0.70 -0.70
12 0.00 0.71 -0.71
13 0.00 0.71 -0.71
14 0.00 0.72 -0.72
15 0.00 0.73 -0.73
16 0.00 0.74 -0.74
17 0.00 0.75 -0.75
18 0.00 0.76 -0.76
19 0.00 0.77 -0.77
20 0.00 0.78 -0.78
AoOferta
(l/s)
Demanda
(l/s)
Balance O-
D (l/s)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Qp
(lp
s)
Aos
BRECHA: Oferta "Sin Proyecto" Vs Demanda "Proyectada"COMPONENTE: Estructura de Captacion
DEMANDA
OFERTA
DEFICIT
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 36 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
2.5.1.4. Balance Oferta-Demanda reservorio de almacenamiento
Se cuenta con un reservorio existente de 5 m3, el cual se encuentra en regular
estado de conservacin, pero segn el clculo de la demanda proyectada al ao
20 el volumen que se requiere es de 11.00 m3, es por ello que se demoler el
reservorio existente y se construir uno nuevo.
Cuadro 20. Balance oferta-demanda Reservorio Apoyado
0 0.00 0.62 -0.62
1 0.00 8.03 -8.03
2 0.00 8.16 -8.16
3 0.00 8.28 -8.28
4 0.00 8.38 -8.38
5 0.00 8.51 -8.51
6 0.00 8.64 -8.64
7 0.00 8.76 -8.76
8 0.00 8.89 -8.89
9 0.00 9.02 -9.02
10 0.00 9.15 -9.15
11 0.00 9.24 -9.24
12 0.00 9.37 -9.37
13 0.00 9.50 -9.50
14 0.00 9.63 -9.63
15 0.00 9.76 -9.76
16 0.00 9.88 -9.88
17 0.00 10.01 -10.01
18 0.00 10.11 -10.11
19 0.00 10.24 -10.24
20 0.00 10.36 -10.36
AoOferta
(m3)
Demanda
(m3)
Balance O-
D (m3)
0
2
4
6
8
10
12
0 5 10 15 20
m3
Aos
BRECHA: Oferta "Sin Proyecto" Vs Demanda "Proyectada"
COMPONENTE: Reservorio Apoyado
DEMANDA
OFERTA
DEFICIT
Elaboracin: F.C. Consorcio Consultor Rural N03
2.5.1.5. Balance Oferta-Demanda red de distribucin
El sistema actual cuenta con una longitud de 288 m de red de distribucin de
tubera que abastece a las viviendas mediante conexiones domiciliarias
artesanales. Las tuberas segn las inspecciones oculares realizadas estn
expuestas, y presentan reparaciones en varios tramos, lo que acrecent el
porcentaje de prdidas de agua. Por lo que en una situacin con proyecto las
redes de distribucin se desecharan. La oferta optimizada de la red de
distribucin es cero.
Por esto se instalar una nueva red de distribucin que considerar criterios de
diseo adecuados en base a normativa y recomendaciones, que no se han
tomado en cuenta para instalar la red que abastece actualmente a la Localidad
de Villa Ancayo
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 37 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Cuadro 21. Balance oferta-demanda Redes de Distribucin
0 0.00 0.07 -0.07
1 0.00 0.93 -0.93
2 0.00 0.94 -0.94
3 0.00 0.96 -0.96
4 0.00 0.97 -0.97
5 0.00 0.98 -0.98
6 0.00 1.00 -1.00
7 0.00 1.01 -1.01
8 0.00 1.03 -1.03
9 0.00 1.04 -1.04
10 0.00 1.06 -1.06
11 0.00 1.07 -1.07
12 0.00 1.08 -1.08
13 0.00 1.10 -1.10
14 0.00 1.11 -1.11
15 0.00 1.13 -1.13
16 0.00 1.14 -1.14
17 0.00 1.16 -1.16
18 0.00 1.17 -1.17
19 0.00 1.18 -1.18
20 0.00 1.20 -1.20
AoOferta
(l/s)
Demanda
(l/s)
Balance O-
D (l/s)
0
0
0
1
1
1
1
1
0 5 10 15 20m
3
Aos
BRECHA: Oferta "Sin Proyecto" Vs Demanda "Proyectada"
COMPONENTE: Redes de Distribucion
DEMANDA
OFERTA
DEFICIT
2.5.1.6. Balance Oferta-Demanda Conexiones domiciliarias
La localidad de Villa Ancayo cuenta con 18 conexiones domiciliarias artesanales
de agua, que los beneficiarios han construido usando tuberas PVC, los mismos
que se encuentran expuestos, y en deficiente estado de conservacin, y no
cumple los requisitos mnimos establecidos en el RNE, ya que fue construido
sin direccin tcnica, por lo que no garantiza las correctas prcticas
constructivas, lo que se traduce en el mal estado en que se encuentra, que la
oferta optimizada de las conexiones domiciliarias es cero.
Cuadro 22. Balance oferta-demanda Conexiones domiciliarias
0 0.00 4.00 -4.00
1 0.00 49.00 -49.00
2 0.00 50.00 -50.00
3 0.00 50.00 -50.00
4 0.00 51.00 -51.00
5 0.00 52.00 -52.00
6 0.00 52.00 -52.00
7 0.00 53.00 -53.00
8 0.00 54.00 -54.00
9 0.00 55.00 -55.00
10 0.00 55.00 -55.00
11 0.00 56.00 -56.00
12 0.00 57.00 -57.00
13 0.00 57.00 -57.00
14 0.00 58.00 -58.00
15 0.00 59.00 -59.00
16 0.00 60.00 -60.00
17 0.00 60.00 -60.00
18 0.00 61.00 -61.00
19 0.00 62.00 -62.00
20 0.00 62.00 -62.00
Balance O-
D (UND)Ao
Oferta
(l/s)
Demanda
(UND)
0
10
20
30
40
50
60
70
0 5 10 15 20
m3
Aos
BRECHA: Oferta "Sin Proyecto" Vs Demanda "Proyectada"
COMPONENTE: Conexiones domiciliarias
DEMANDA
OFERTA
DEFICIT
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 38 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
0 0.00 0.00 0.00
1 0.00 49.00 -49.00
2 0.00 50.00 -50.00
3 0.00 50.00 -50.00
4 0.00 51.00 -51.00
5 0.00 52.00 -52.00
6 0.00 52.00 -52.00
7 0.00 53.00 -53.00
8 0.00 54.00 -54.00
9 0.00 55.00 -55.00
10 0.00 55.00 -55.00
11 0.00 56.00 -56.00
12 0.00 57.00 -57.00
13 0.00 57.00 -57.00
14 0.00 58.00 -58.00
15 0.00 59.00 -59.00
16 0.00 60.00 -60.00
17 0.00 60.00 -60.00
18 0.00 61.00 -61.00
19 0.00 62.00 -62.00
20 0.00 62.00 -62.00
AoOferta
(l/s)
Demanda
(UND)
Balance O-
D (UND)
0
10
20
30
40
50
60
70
0 5 10 15 20
m3
Aos
BRECHA: Oferta "Sin Proyecto" Vs Demanda "Proyectada"
COMPONENTE: UBS
DEMANDA
OFERTA
DEFICIT
2.5.2. Balance Oferta-Demanda Sistema de Saneamiento
Al no existir un sistema de UBS (Unidades bsicas de Saneamiento), no es
posible optimizar, por lo tanto la oferta optimizada es cero.
Cuadro 23. Balance oferta-demanda UBS
3. DESCRIPCIN DE OBRAS DE AGUA Y SANEAMIENTO
3.1. Descripcin de obras proyectadas del Sistema de Agua Potable
Para el sistema de agua potable propuesto se consider realizar dos sistemas
para darle solucin y beneficiar a todos las familias:
Sistema N01: Denominado Sector Central, tiene las siguientes
componentes:
Captacin tipo ladera : 03 und.
Lnea de conduccin : 161.21 ml.
Reservorio apoyado V=9m3 : 01 und.
Red de Distribucin : 2428.44 ml.
Vlvula de Purga : 03 und.
Vlvula de aire : 01 und.
Vlvula compuerta : 03 und.
Pase areo (70 m) : 01 und.
Conexiones domiciliarias : 40 und.
Sistema N02: Denominado Sector N02, tiene las siguientes
componentes.
Captacin reservorio : 01 und.
Red de distribucin : 1613.68 ml.
Vlvula de Purga TII : 03 und.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 39 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Vlvula de compuerta : 02 und.
Cmara Rompe Presin T7 : 03 und.
Conexiones domiciliarias : 08 und
3.1.1. Sistema Sector Central
3.1.1.1. Captacin
En este sistema se proyect 3 captaciones tipo manantial de ladera, las tres
captaciones (Villa Ancayo N01, Villa Ancayo N03 y Villa Ancayo N05) son de
las mimas dimensiones y captaran caudales de 0.35 l/seg, 0.13 l/seg y 0.22
l/seg respectivamente, no se construirn cmaras de reunin con la finalidad de
ganar altura en los diseo, estos caudales se unirn en la cmara hmeda de
las captaciones.
L
a
c
aptacin Villa Ancayo N01, se encuentra ubicada en las coordenadas
530603.79 E, 8,747,793.51 N y a una altura de 961 m.s.n.m., el aforo de la
fuente en poca de estiaje es de 0.35 L/s y en poca de lluvias es de 0.70 L/s,
se ha diseado teniendo en cuenta el caudal de mxima avenida y una tubera
de salida de conduccin de PVC SP C-10.
La estructura ser de concreto armado de fc=210 kg/cm2, en donde la cmara
hmeda tendr seccin cuadrada con dimensiones interiores de 1.00 m de lado
y 0.90 m de altura, con un espesor de muro terminado de 0.15 m; tendr tapa
metlica de 0.60 m x 0.60 m x 1/8.En la cmara hmeda se colocar un
vertedero de vertedero 1.00 m x 0.15 m x 1/4 el cual proporcionar carga
hidrulica y a su vez podr generar un control del caudal que ingresa a la
captacin.
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 40 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Luego se construir una cmara seca de 0.65 m x 0.60 m con un espesor de
muro de 0.15 m, ir con una tapa metlica de 0.60 m x 0.60 m x 1/8. Dentro de
la cmara seca irn las vlvulas que dan salida a la tubera de conduccin de
PVC-U C-10 de . Se construirn dos aletas de concreto armado fc= 175
kg/cm2 de 2.25 m x 0.80 m y 0.15 m de espesor, las cuales servirn para
asegurar la direccin del flujo del manantial. Dentro de stas se colocarn 04
capas filtrantes colocadas a lo largo de 1.30 m, que permitirn obtener un mejor
filtrado. Se colocar un sello sanitario de concreto simple fc=140 kg/cm2, que
ir con tapa metlica de inspeccin de 0.60 m x 0.60 m x 1/8
La captacin Villa Ancayo N03, se encuentra ubicada en las coordenadas
530,603.79 E, 8747862.79 N y a una altura de 930 m.s.n.m., el aforo de la
fuente en poca de estiaje es de 0.13 L/s y en poca de lluvias es de 0.26 L/s,
se ha diseado teniendo en cuenta el caudal de mxima avenida y una tubera
de salida de conduccin de 1 PVC SP C-10.
La estructura ser de concreto armado de fc=210 kg/cm2, en donde la cmara
hmeda tendr seccin cuadrada de dimensiones interiores de 1.00 m de lado y
0.90 m de altura, con un espesor de muro terminado de 0.15 m; tendr tapa
metlica de 0.60 m x 0.60 m x 1/8.En la cmara hmeda se colocar un
vertedero de PVC de 1.00 m x 0.15 m x 1/8 el cual proporcionar carga
hidrulica y a su vez podr generar un control del caudal que ingresa a la
captacin.
Luego se construir una cmara seca de 0.65 m x 0.60 m con un espesor de
muro de 0.15 m, ir con una tapa metlica de 0.60 m x 0.60 m x 1/8. Dentro de
la cmara seca irn las vlvulas que dan salida a la tubera de conduccin de
PVC-U C-10 de 1. Se construirn dos aletas de concreto armado fc= 175
kg/cm2 de 2.25 m x 0.80 m y 0.15 m de espesor, las cuales servirn para
asegurar la direccin del flujo del manantial. Dentro de stas se colocarn 04
capas filtrantes colocadas a lo largo de 1.30 m, que permitirn obtener un mejor
filtrado. Se colocar un sello sanitario de concreto simple fc=100 kg/cm2, que
ir con tapa metlica de inspeccin de 0.60 m x 0.60 m x 1/8.
La captacin Villa Ancayo N05, se encuentra ubicada en las coordenadas
530,541.75 E, 8747901.78 N y a una altura de 919 m.s.n.m., el aforo de la
fuente en poca de estiaje es de 0.22 L/s y en poca de lluvias es de 0.44 L/s,
se ha diseado teniendo en cuenta el caudal de mxima avenida y una tubera
de salida de conduccin de 1 PVC SP C-7.5
La estructura ser de concreto armado de fc=210 kg/cm2, en donde la cmara
hmeda tendr seccin cuadrada de dimensiones interiores de 1.00 m de lado y
0.90 m de altura, con un espesor de muro terminado de 0.15 m; tendr tapa
metlica de 0.60 m x 0.60 m x 1/8.En la cmara hmeda se colocar un
vertedero de PVC de 1.00 m x 0.15 m x 1/8 el cual proporcionar carga
hidrulica y a su vez podr generar un control del caudal que ingresa a la
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 41 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
captacin.
Luego se construir una cmara seca de 0.65 m x 0.60 m con un espesor de
muro de 0.15 m, ir con una tapa metlica de 0.60 m x 0.60 m x 1/8. Dentro de
la cmara seca irn las vlvulas que dan salida a la tubera de conduccin de
PVC-U C-10 de 1 1/2. Se construirn dos aletas de concreto armado fc= 175
kg/cm2 de 2.25 m x 0.80 m y 0.15 m de espesor, las cuales servirn para
asegurar la direccin del flujo del manantial. Dentro de stas se colocarn 04
capas filtrantes colocadas a lo largo de 1.30 m, que permitirn obtener un mejor
filtrado. Se colocar un sello sanitario de concreto simple fc=100 kg/cm2, que
ir con tapa metlica de inspeccin de 0.60 m x 0.60 m x 1/8.
3.1.1.2. Lnea de Conduccin
Se ah diseado tres tramos en la lnea de conduccin, cada tramo tiene
diferentes parmetros.
El primer tramo tiene los siguientes parmetros de diseo
Cuadro 24. Diseo de lnea de conduccin Tramo N01
1.- DATOS DE DISEO
DESCRIPCION FORMULA VALOR UND
Caudal Promedio Qp = 0.27 lts/seg
Caudal de Diseo (Maximo
Diario) Qmd = 0.35 lts/seg
Longitud Del Tramo L= 98.78 m
Material de la Tuberia PVC
Coef. De Hazen y Williams C= 150.00
Clase de la Tuberia cl= 10
Cota de Inicio Ci= 961.08 m.s.n.m.
Cota de Fin Cf= 931.00 m.s.n.m.
2.- CALCULO PARA DETERMINAR PRESION FINAL
DESCRIPCION FORMULA VALOR UND
Carga Disponible CD=Ci-Cf 30.08 m
Pendiente Max Smax=CD/L 0.30 m/m
Diametro Teorico Dt=(Q/(0.2785*C*S^0.54)^(1/2.63) 14.99 mm
Diametro Comercial Dint= 22.90 mm
Pendiente S=(Q/(0.2785*C*D^2.63)^(1/0.54) 0.04 m/m
Area A=pi*Di^2/4 0.00041 m2
Velocidad V=0.8494*C*(Di/4)^0.63*S^0.54 0.85 m/seg
Hf Accesorios (Asumimos
de 1-2m) Hfacc= 0.40 m
Hf Tuberias Hftub=S*L 3.81 m
Hf Total Hft=Hfacc+Hftub 4.21 m
-
MEJORAMIENTO Y AMPLIACIN DEL SERVICIO DE AGUA POTABLE E INSTALACIN DEL SERVICIO DE
DISPOSICIN SANITARIA EXCRETAS EN EL CENTRO POBLADO VILLA ANCAYO, DISTRITO PAMPA HERMOSA
- SATIPO - JUNN
Pgina 42 de 81 MEMORIA DESCRIPTIVA Y
JUSTIFICATIVA
Cota de GHD Final GHDf1=Ci-Hft 956.87 m.s.n.m.
Presion Final Pf1=GHDf-Cf 25.87 m.s.n.m.
Cuadro 25. Diseo de lnea de conduccin Tramo N02
1.- DATOS DE DISEO
DESCRIPCION FORMULA VALOR UND
Caudal Promedio Qp = 0.37 lts/seg
Caudal de Diseo (Maximo
Diario) Qmd = 0.48 lts/seg
Longitud Del Tramo L= 47.26 m
Material de la Tuberia PVC
Coef. De Hazen y Williams C= 150.00
Clase de la Tuberia cl= 10
Cota de Inicio Ci= 931.12 m.s.n.m.
Cota de Fin Cf= 919.30 m.s.n.m.
2.- CALCULO PARA DETERMINAR PRESION FINAL
DESCRIPCION FORMULA VALOR UND
Carga Disponible CD=Ci-Cf 11.82 m
Pendiente Max Smax=CD/L 0.25 m/m
Diametro Teorico Dt=(Q/(0.2785*C*S^0.54)^(1/2.63) 17.59 mm
Diametro Comercial Dint= 29.40 mm
Pendiente S=(Q/(0.2785*C*D^2.63)^(1/0.54) 0.02 m/m
Area A=pi*Di^2/4 0.00068 m2
Velocidad V=0.8494*C*(Di/4)^0.63*S^0.54 0.71 m/seg
Hf Accesorios (Asumimos
de 1-2m) Hfacc= 0.40 m
Hf Tuberias Hftub=S*L 0.97 m
Hf Total Hft=Hfacc+Hftub 1.37 m
Cota de GHD Final GHDf1=Ci-Hft 929.75 m.s.n.m.
Presion Final Pf1=GHDf-Cf 10.45 m.s.n.m.
Cuadro 26. Diseo de lnea de conduccin Tramo N03
1.- DATOS DE DISEO
DESCRIPCION FORMULA VALOR UND
Caudal Promedio Qp = 0.50 lts/seg
Caudal de Diseo (Maximo
Diario) Qmd = 0.64 lts/seg
Longitud Del Tramo L= 15.57 m
Material de la Tuberia PVC
Coef. De Haz