ME MS Series overview - 星和電機株式会社 · For special units arrangement and ... 3)Red...

5
ME MS Weather Proof Type Control Boxes 101 102 Weather Proof Type Control Boxes 2015 September http://www.seiwa.co.jp [email protected] 2015 September http://www.seiwa.co.jp [email protected] Series overview ■Features FG2 FG3 FG5 FG6 150 150 150 265 200 295 400 290 100 150 250 180 59.5 84.5 84.5 64.5 95 95 95 210 4-φ7 4-φ7 4-φ7 4-φ10 ME2A/MS2A ME3A/MS3A ME5A/MS5A ME6A/MS6A A B C D E F MS stand type ME wall-mounted type Explosion-proof type Installation type (E: Wall-mounted type, S: Stand type) 1) Control box model no. ■Information required for orders ME2A ME3A ME5A ME6A MEAA MEBA MECA E A F D C B 165 50 12 形式 N4010HA A H 8 0 0 2 N A H 0 1 0 3 N ※ If requiring the stand type for the MEAA, MEBA or MECA, contact us. 40 10 30 10 20 8 4P 8P 12P 16P 24P 36P 64P ME1A ME (S)2A ME (S)3A ME (S)5A ME (S)6A MEAA MEBA MECA 1) Dust- and spray-proof construction equal to IP65 protection 2) Housed in a stainless steel box that stands up to corrosion and weather. Waterproof construction contents for use outdoors. 3) High brightness LEDs used for indicator lights because they are bright and easy to see. Long-lasting and maintenance-free. 4) Boxes come with hinges to facilitate wiring work, checks and maintenance. Box size: 1A - 5A, AA - CA Unit arrangement Options (W: Internal wiring, F: Hood) Special order (C: Special painting, H: Hub specification, X: Other * CHX indicated as X.) 2) Installation unit specifications (For details, see p. 105 - 106.) 3) Cable entry specifications ・Wall-mounted type: Select cable entry specifications from the below table. For cable wiring, select a cable gland model from p. 101 - 102. However, the cable gland is provided as an accessory. Hub size G3/4 or G1/2 G3/4 or G1/2 G3/4 or G1 G3/4 or G1/2 G1 G1 G1 Hub location 1 on bottom 1 on bottom 1 on bottom 2 on bottom 2 on bottom 3 on bottom 4 on bottom Box size Standard cable entry specifications ■Installation and connection work ・Wiring connections require either cabling and/or conduit work. ・With the stand type, use usually available foundation bolts. ■Precautions for use ※Optional adapters work with NPT and M threads. The adapter is packaged with the product as an accessory. It cannot be shipped already installed on the control box. Adapter types G1/2-NPT1/2 or M20 G3/4-NPT3/4 or M25 G1-NPT1 or M32 Adapter ・Stand type: Specify the cable outer diameter. One(1) cable can enter. Applicable cable outer diameter is within Ø8.8 - 20. The stand type is designed only for cable connection and the external cable port is fitted with packing. In normal use, these control boxes can stand up to corrosion. However if used in places where exposed to salty air or other adverse conditions, rusting and other issues may occur in a short period of timeIn such case, please contact us before purchasing. ■Construction of main parts Box: Stainless steel sheet Tightening bolts: Stainless steel Stand pole: Thick steel electrical conduit Stand base: Aluminum alloy Coating: Baked-on melamine resin (Only the outside is coated for 2-6 units control boxes.) Color: 5Y7/1 ■Optional Parts and Special Order Specifications Stainless steel Standard: no paint Special Order: painted with specified color ●Hood Type Applicable models *Can also be manufactured for the ME1A as a customized product. *Stand types (MS) cannot be retrofitted with a hood. Specify a hood when placing your order. ●Internal Terminal Block For control boxes with internal wiring, wire mark can be provided as a special order. Rating: 500 V, 25 A Max. connectable wire gauge: 3.5 mm 2 Terminal screw: M4 x 10 ●Wire Mark (Special Order) Max. internal terminals ●Name Plate Model no. N5012HA Acrylic, t2 thick, adhesive type Black letters etched from backside on white background Round gothic font (Character limit applies.) ※Stainless steel name plate is also available as a special order. ●Manufacture Label Standard: Tetoron® Film Special Order: Stainless steel ●Tropical Treatment (Special Order) Unit terminal screws are changed to stainless steel screws. ●Unite Name Plate * For repeat orders, provide the 6-digit serial No. ●Internal Wiring ・Internal terminal block is provided as well as standard wiring between units and the terminal block. For special units arrangement and wiring, please contact us. ・Control boxes with internal wiring are not the same as those without internal wiring. Thus, terminal blocks cannot be added at customer’s side. Acrylic, t2 thick, adhesive type Black letters etched from backside on white background Round gothic font (with letter limit) ※Stainless steel name plate is also available as a special order.

Transcript of ME MS Series overview - 星和電機株式会社 · For special units arrangement and ... 3)Red...

Page 1: ME MS Series overview - 星和電機株式会社 · For special units arrangement and ... 3)Red Needle provided(special ... Selector switch ……Pushbutton switch ……Buzzer

ME・MS

Weather Proof Type Control Boxes

101 102

Weather Proof Type Control Boxes

2015 September http://www.seiwa.co.jp [email protected] 2015 September http://www.seiwa.co.jp [email protected]

Series overview

■Features

FG2FG3FG5FG6

150150150265

200295400290

100150250180

59.584.584.564.5

959595210

4-φ74-φ74-φ74-φ10

ME2A/MS2AME3A/MS3AME5A/MS5AME6A/MS6A

A B C D E F

MS stand type

ME wall-mounted type

Explosion-proof type

Installation type (E: Wall-mounted type, S: Stand type)

1) Control box model no.

■Information required for orders

ME2AME3AME5AME6AMEAAMEBAMECA

EA

F

DC B

165

50

12

形式 N4010HA

AH8002N 式形

AH0103N 式形

※ If requiring the stand type for the MEAA, MEBA or MECA, contact us.

40

10

30

10

20

8

4P8P12P16P24P36P64P

ME1AME(S)2AME(S)3AME(S)5AME(S)6AMEAAMEBAMECA

1) Dust- and spray-proof construction equal to IP65 protection2) Housed in a stainless steel box that stands up to corrosion and weather. Waterproof construction contents for use outdoors.

3) High brightness LEDs used for indicator lights because they are bright and easy to see. Long-lasting and maintenance-free.

4) Boxes come with hinges to facilitate wiring work, checks and maintenance.

Box size: 1A - 5A, AA - CA

Unit arrangement

Options (W: Internal wiring, F: Hood)

Special order(C: Special painting, H: Hub specification, X: Other * CHX indicated as X.)

2) Installation unit specifications (For details, see p. 105 - 106.) 3) Cable entry specifications・Wall-mounted type: Select cable entry specifications from the below table. For cable wiring, select a cable gland model from p. 101 - 102. However, the cable gland is provided as an accessory.

Hub sizeG3/4 or G1/2G3/4 or G1/2G3/4 or G1G3/4 or G1/2

G1G1G1

Hub location1 on bottom1 on bottom1 on bottom2 on bottom2 on bottom3 on bottom4 on bottom

Box sizeStandard cable entry specifications

■Installation and connection work・Wiring connections require either cabling and/or conduit work.・With the stand type, use usually available foundation bolts.

■Precautions for use

※Optional adapters work with NPT and M threads.

The adapter is packaged with the product as an accessory. It cannot be shipped already installed on the control box.

Adapter typesG1/2-NPT1/2 or M20G3/4-NPT3/4 or M25G1-NPT1 or M32Adapter

・Stand type: Specify the cable outer diameter. One(1) cable can enter. Applicable cable outer diameter is within Ø8.8 - 20. The stand type is designed only for cable connection and the external cable port is fitted with packing.

In normal use, these control boxes can stand up to corrosion. However if used in places where exposed to salty air or other adverse conditions, rusting and other issues may occur in a short period of timeIn such case, please contact us before purchasing.

■Construction of main partsBox: Stainless steel sheetTightening bolts: Stainless steelStand pole: Thick steel electrical conduitStand base: Aluminum alloyCoating: Baked-on melamine resin (Only the outside is coated for 2-6 units control boxes.)Color: 5Y7/1

■Optional Parts and Special Order Specifications

Stainless steel Standard: no paintSpecial Order: painted with

specified color

●Hood Type Applicable models

*Can also be manufactured for the ME1A as a customized product.*Stand types (MS) cannot be retrofitted with a hood. Specify a hood when placing your order.

●Internal Terminal Block

For control boxes with internal wiring,wire mark can be provided as a special order.

Rating: 500 V, 25 AMax. connectable wire gauge: 3.5 mm2

Terminal screw: M4 x 10

●Wire Mark (Special Order)

Max. internal terminals

●Name PlateModel no. N5012HAAcrylic, t2 thick, adhesive typeBlack letters etched from backside on white backgroundRound gothic font (Character limit applies.)※Stainless steel name plate is also available as a special order.

●Manufacture Label

Standard: Tetoron® FilmSpecial Order: Stainless steel

●Tropical Treatment (Special Order)

Unit terminal screws are changed to stainless steel screws.

●Unite Name Plate

* For repeat orders, provide the 6-digit serial No.

●Internal Wiring・Internal terminal block is provided as well as standard wiring between units and the terminal block. For special units arrangement and wiring, please contact us.・Control boxes with internal wiring are not the same as those without internal wiring. Thus, terminal blocks cannot be added at customer’s side.

Acrylic, t2 thick, adhesive typeBlack letters etched from backside on white backgroundRound gothic font (with letter limit)※Stainless steel name plate is also available as a special order.

Page 2: ME MS Series overview - 星和電機株式会社 · For special units arrangement and ... 3)Red Needle provided(special ... Selector switch ……Pushbutton switch ……Buzzer

symbol S

AR30JR seriesKey Selector Switch

symbol LPilot Lamp

DR30D0L series

AR30PR series

AR30GPR series

103 1042015 September http://www.seiwa.co.jp [email protected] 2015 September http://www.seiwa.co.jp [email protected]

Contorol Units for Control Box Contorol Units for Control Box

IP 65Degree of protection

IP 65Degree of protection

symbol M

symbol S

MUM series

Selector Switch

symbol P

symbol P

AR30F0R seriesPushbutton SwitchAmmeter

Pin-lock Type Pushbutton Switch

AR30V2R seriessymbol PPush-lock Type Pushbutton Switch

Class : Class 2.5

Light Source : LED

The lens is made of Plastics.

Direct current graduation : 15A, 10A, 5A, 3A, 1ACT correspondence current graduation :

,A3 5A, 10A, 15A, 20A, 30A, 40A, 50A, 60A, 75A, 100A, 150ACT secondary current : 5A, 1AExtension scale : ×3(standard), ×2(special)Demand : /5A…1.3VA /1A…0.9VA

Demand : 1.5VARated Voltage : 100 - 110V, 200 - 220V, or 220 - 254VLens Color : Red, Green, Orange, Milk White

Contact : 1a, 1b, 1a1bColor : Black, Red, GreenLetter : ON / OFF / START / STOP / FOR / REV

Rating for Selector Switches and Push Buttons

Specifications of units Individual sale of these units is only for maintenance purpose. Specifications of units Individual sale of these units is only for maintenance purpose.

Option(with guard)

Please Specify1)Extension scale2)CT Ratio3)Red Needle provided(special) / not provided (standard)

Please Specify

1)Rated Voltage2)Lens Color

Please Specify

1)No. of Notch2)Contact3)Letter

No. of Notch : 2-notch, 3-notch,Contact : 1a, 1b, 1a1b(over-lap), 2a, 2a2b

Other letters are available.

Please Specify

1)Contact2)Color3)Letter

Contact : 1a, 1b, 1a1bColor : Black, Red, GreenLetter ( On unit name plate. ) : OFF / STOP

Other letters are available.

Please Specify

1)Contact2)Color3)Letter

1)Contact2)Letter

Contact : 1b, 1a1bColor : Red onlyLetter ( On unit name plate. ) : EMERGENCY STOP / STOP

Other letters are available.

Please Specify

DC ammeter and frequency meterare also available. Please specify input current and scale.

AC15 (coil load) AC12 (resistance load) (coil load) (resistance load)DC13 DC12

AC,DC600V10A

Rated operating voltage & current

AC DC

Rated operating voltage (V)

Rated operating current (A)

Rated operating voltage (V)

Rated operating current (A)

24 6 24 6 6110 6 110 1.3 2.5220 6 220 0.45 1440 2.5 - - -550 2

10101053 - - -

InsulationRated carried current

Letter ( On unit name plate ) : ON / OFF, MAN / AUTO, MAN / OFF / AUTOOther letters are available.

Please Specify

1)No. of Notch2)Contact3)Letter

No. of Notch : 2-notch, 3-notch,Contact : 1a, 1b, 1a1b(over-lap), 2a, 2a2b

Letter ( On unit name plate ) : ON / OFF, MAN / AUTO, MAN / OFF / AUTOOther letters are available.

Page 3: ME MS Series overview - 星和電機株式会社 · For special units arrangement and ... 3)Red Needle provided(special ... Selector switch ……Pushbutton switch ……Buzzer

Weather Proof Type Control Boxes

105 1062015 September http://www.seiwa.co.jp [email protected] 2015 September http://www.seiwa.co.jp [email protected]

Combination of 3 units IP 65Degree of protection

Unit arrangement

1 2 3 4

Connection

Provision of wiring no yes no yes no yes no yes

Wall-mounted type ME3AL3 ME3AL3W ME3AL1P2 ME3AL1P2W ME3AP3 ME3AP3W ME3AL2S1 ME3AL2S1W

Stand type MS3AL3 MS3AL3W MS3AL1P2 MS3AL1P2W MS3AP3 MS3AP3W MS3AL2S1 MS3AL2S1W

Unit arrangement

5 6 7 8

Connection

Provision of wiring no yes no yes no yes no yes

Wall-mounted type ME3AS1P2 ME3AS1P2W ME3AM1P2 ME3AM1P2W ME3AS3 ME3AS3W ME3AL2P1 ME3AL2P1W

Stand type MS3AS1P2 MS3AS1P2W MS3AM1P2 MS3AM1P2W MS3AS3 MS3AS3W MS3AL2P1 MS3AL2P1W

Mass : max.1.2kg (ME3AM1P2)……Pilot lamp ……Selector switch ……Pushbutton switch ……Buzzer ……Cam…operated switch……AmmeterM

111.5

NP

235

150

OFF

ON

Grounding terminal M4

Hinge

95(Dimension)100

115

29.5

)7φ(seloh 4

G3/4(22mm) or G1/2(16mm)Conduit socket

Grounding terminal M5

R75)41φ(seloh 3φ180

1395

100

Cable O.D. Max.φ20

235

Stand base

Stand pipe 42mm conduit

Gasket type entry

110

30° 30°

A

NP

A arrow diagram

LL

LPL

PPP

PLL

S

PS

PSS

SLL

PPPM

1 2OL

RL

GL

3 4

5 6

1 2RL

3 4

ON

5OFF

3 4

FOR

REV

1 2

5

STOP6

1 2RL

GL3

56

AUTOMANU4

4

6

5ON

OFF

AUTOMANU1 2

3

1 2ONOFF

3 4ONOFF

5 6ONOFF

1 2

3

RL

GL

4 5

ON

1 M 2

3 4

ON

5OFF

Weather Proof Type Control Boxes

Combination of 1 or 2 units IP 65Degree of protection

Unit arrangement

1 2 3 4 5

Connection

Provision of wiring no yes no yes no yes no yes no yes

Wall-mounted type ME2AL1 ME2AL1W ME2AP1 ME2AP1W ME2AP1 ME2AP1W ME2AP1 ME2AP1W ME2AS1 ME2AS1W

Stand type MS2AL1 MS2AL1W MS2AP1 MS2AP1W MS2AP1 MS2AP1W MS2AP1 MS2AP1W MS2AS1 MS2AS1W

Unit arrangement

6 7 8 9 10

Connection

Provision of wiring no yes no yes no yes no yes no yes

Wall-mounted type ME2AL2 ME2AL2W ME2AP2 ME2AP2W ME2AL1P1 ME2AL1P1W ME2AL1S1 ME2AL1S1W ME2AS2 ME2AS2W

Stand type MS2AL2 MS2AL2W MS2AP2 MS2AP2W MS2AL1P1 MS2AL1P1W MS2AL1S1 MS2AL1S1W MS2AS2 MS2AS2W

Mass : max.0.8kg (ME2AL2)……Pilot lamp ……Selector switch ……Pushbutton switch ……Buzzer ……Cam…operated switch……AmmeterM

111.5

NP

29.5Grounding terminal M4

100

145

95(Dimension)100

115

)7φ(seloh 4

Hinge

OFF

ON

G3/4(22mm) or G1/2(16mm)Conduit socket

)41φ(seloh 3

Grounding terminal M5

R75

1305

φ180

Cable O.D. Max.φ20

A arrow diagram

145

100

Stand pipe 42mm conduit

Stand base

Gasket type entry

110

30° 30°

A

NP

LL

1 2RL

3 4GL

PP

1 2ON

3OFF

PL

1 2RL

3 4ON

LS

SS

1 2RL

ONOFF3 4

ONOFF1 2

ONOFF3 4

L

1 2RL

P

1 2

ON

P

1 2OFF

P S

1 2

EMERGENCYSTOP AUTOMANU

1 23

Page 4: ME MS Series overview - 星和電機株式会社 · For special units arrangement and ... 3)Red Needle provided(special ... Selector switch ……Pushbutton switch ……Buzzer

Weather Proof Type Control Boxes

107 108

Weather Proof Type Control Boxes

2015 September http://www.seiwa.co.jp [email protected] 2015 September http://www.seiwa.co.jp [email protected]

Combination of 6 units IP 65Degree of protection

Unit arrangement

1 2 3

Connection

Provision of wiring no yes no yes no yes

Wall-mounted type ME6AL6 ME6AL6W ME6AP6 ME6AP6W ME6AL2P4 ME6AL2P4W

Stand type MS6AL6 MS6AL6W MS6AP6 MS6AP6W MS6AL2P4 MS6AL2P4W

Unit arrangement

4 5 6

Connection

Provision of wiring no yes no yes no yes

Wall-mounted type ME6AS2P4 ME6AS2P4W ME6AM2P4 ME6AM2P4W ME6AL4S2 ME6AL4S2W

Stand type MS6AS2P4 MS6AS2P4W MS6AM2P4 MS6AM2P4W MS6AL4S2 MS6AL4S2W

Mass : max.2.5kg (ME6AM2P4)……Pilot lamp ……Selector switch ……Pushbutton switch ……Buzzer ……Cam…operated switch……AmmeterM

L LL LL L

P PP PP P

L LP PP P

1 2OL

3 4RL

5 6GL

× 23 4

FOR

REV

1 2

5

STOP6

× 23 4

ON

5OFF

RL1 2

× 2

S SP PP P

L LL LS S

P PP P

M M

3 4ON

5OFF

1 M 223

5ON

AUTOMANU1

4

OFF6

× 2

1 2RL

GL3

56

AUTOMANU4

× 2

NP

112

Hinge

Grounding terminal M4

30

200

210(Dimension)230

235

180

)01φ(seloh 4

85

OFF OFF

ON ON

G3/4(22mm) or G1/2(16mm)Conduit socket

)41φ(seloh 3

Grounding terminal M5

R75

30° 30°

1395

φ180

Cable O.D. Max.φ20

Stand base

110200

235

Stand pipe 42mm conduit

Gasket type entry

NP

AA arrow diagram

× 2

Weather Proof Type Control Boxes

Combination of 4 or 5 units IP 65Degree of protection

Unit arrangement

1 2 3 4 5

Connection

Provision of wiring no yes no yes no yes no yes no yes

Wall-mounted type ME5AL2P2 ME5AL2P2W ME5AL1S1P2 ME5AL1S1P2W ME5AM1S1P2 ME5AM1S1P2W ME5AM1L1P2 ME5AM1L1P2W ME5AM1P3 ME5AM1P3W

Stand type MS5AL2P2 MS5AL2P2W MS5AL1S1P2 MS5AL1S1P2W MS5AM1S1P2 MS5AM1S1P2W MS5AM1L1P2 MS5AM1L1P2W MS5AM1P3 MS5AM1P3W

Unit arrangement

6 7 8 9 10

Connection

Provision of wiring no yes no yes no yes no yes no yes

Wall-mounted type ME5AL2P3 ME5AL2P3W ME5AL2S1P2 ME5AL2S1P2W ME5AM1L1S1P2 ME5AM1L1S1P2W ME5AM1L2P2 ME5AM1L2P2W ME5AM1L1P3 ME5AM1L1P3W

Stand type MS5AL2P3 MS5AL2P3W MS5AL2S1P2 MS5AL2S1P2W MS5AM1L1S1P2 MS5AM1L1S1P2W MS5AM1L2P2 MS5AM1L2P2W MS5AM1L1P3 MS5AM1L1P3W

Mass : max.2.1kg (ME5AM1L2P2)……Pilot lamp ……Selector switch ……Pushbutton switch ……Buzzer ……Cam…operated switch……AmmeterM

345

250

111.5

NP

29.5

OFF

ON

(seloh 4 φ7)

Grounding terminal M4

Hinge

95(Dimension)110115

G1(28mm) or G3/4(22mm)Conduit socket

)41φ(seloh 3

Grounding terminal M5

R75

30° 30°

1500

φ180

Cable O.D. Max.φ20

Stand base

Stand pipe 42mm conduit

110

345

Gasket type entry

110

NP

AA arrow diagram

LLPP

1 2RL

GL3

4 5ON

6 OFF

LSPP

RL1 2

68

7ON

OFF

AUTOMANU3 4

5

SPP

M

1 2

68

7ON

OFF

AUTOMANU3 4

5

M

LPP

MPPP

M

RL

ON

OFF

3 4

1 M 2

5 6

7

1 2

5 6

FOR

REV

3 4

7

STOP8

M

LL

PP

P

1 2RL

GL3

6 7

FOR

REV

4 5

8STOP 9

LL

PS

P

1 2

56

8

RL

GL3

ON

AUTOMANU4

7

OFF9

L

PS

P

M

67

9ON

AUTOMANU5

8

OFF10

RL3 4

1 M 2

L

PL

P

ML

PP

P

M

6 7ON

8OFF

RL

GL

3 4

5

1 M 2 1 2

4RL

3

7 8

FOR

REV

5 6

9

STOP 10

M

Page 5: ME MS Series overview - 星和電機株式会社 · For special units arrangement and ... 3)Red Needle provided(special ... Selector switch ……Pushbutton switch ……Buzzer

Weather Proof Type Control Boxes

109 110

Weather Proof Type Control Boxes

2015 September http://www.seiwa.co.jp [email protected] 2015 September http://www.seiwa.co.jp [email protected]

Combination of 12 or 15 units IP 65Degree of protection

Unit arrangement

1 2 3

Connection

Provision of wiring no yes no yes no yes

Wall-mounted type MEBAL6P6 MEBAL6P6W MEBAL3S3P6 MEBAL3S3P6W MEBAM3L3P6 MEBAM3L3P6W

Unit arrangement

4 5

Connection

Provision of wiring no yes no yes

Wall-mounted type MEBAL6S3P6 MEBAL6S3P6W MEBAM3L3S3P6 MEBAM3L3S3P6W

Mass : max.6.5kg (MEBAM3L3S3P6)

……Pilot lamp ……Selector switch ……Pushbutton switch ……Buzzer ……Cam…operated switch……AmmeterM

85

300315(Dimension)

335

OFF

ON

250

360

85

OFF

4 holes(φ10)

34Grounding terminal M4

NP

127

ON ON

OFF

G1(28mm)Conduit socket

LLPP

LLPP

LLPP

1 2RL

GL3

4 5ON

6OFF

× 3

7ON

6

OFF8

45

AUTOMANU3

RL1 2

× 3

1 2

4RL

M

3

5 6ON

7OFF

× 3

9ON

8

OFF10

67

 AUTOMANU5

RL3 4

1 2M1 2

RL

GL3

8ON

7

OFF9

56

AUTOMANU4 × 3 × 3

LSPP

LSPP

LSPP

LPP

LPP

LPP

M MM

LL

PP

LL

PP

LL

S S SPP

L

PP

L

PP

LS S S

PP

M MM

of 24 unitsCombinatain (MECA)is also available upon request.

youIf need a stand type versionof the MEBA and MECA seriesmodels,consult us.

inOnly the MEBA and MECAseries models, coating is appliedto both the inside and outsidesurfaces (melamine resin coating,colour 5Y7/1)

Combination of 8 or 10 units IP 65Degree of protection

Unit arrangement

1 2 3 4

Connection

Provision of wiring no yes no yes no yes no yes

Wall-mounted type MEAAL4P4 MEAAL4P4W MEAAL2S2P4 MEAAL2S2P4W MEAAM2L2P4 MEAAM2L2P4W MEAAL4S2P4 MEAAL4S2P4W

Unit arrangement

5 6

Connection

Provision of wiring no yes no yes

Wall-mounted type MEAAL4P6 MEAAL4P6W MEAAM2L2S2P4 MEAAM2L2S2P4W

Mass : max.5.1kg (MEAAM2L2S2P4)

……Pilot lamp ……Selector switch ……Pushbutton switch ……Buzzer ……Cam…operated switch……AmmeterM

85

215230(Dimension)

250

OFF

ON

127

360

Grounding terminal M4

250

4 holes(φ10) 34

NPON

OFF

G1(28mm)Conduit socket

L LL LP PP P

L LS SP PP P

7ON

6

OFF8

45

AUTOMANU3

RL1 2

× 2GL

1 2RL

3

8ON

7

OFF9

56

AUTOMANU4 × 2

1 2

4RL

3

9ON

8

OFF10

67

AUTOMANU5

M

3

7

FOR

REV

1

64 5

8

STOP9

2RL

GL

× 2 × 2

L L

S SL L

P PP P

1 2RL

GL3

4 5ON

6OFF

× 2

L L

P PL L

P PP P

S SL L

P PP P

M M

RL

ON

OFF

3 4

1 M 2

5 6

7

× 2

youIf need a stand type version

of the MEAA series models,

consult us.inOnly the MEAA series models,

coating is applied to both the

ins ide and outs ide sur faces

(melamine resin coating, colour

5Y7/1)

L LP PP P

M M

・ ・