CONECCION DE PLC-1200 A LOGO
Realizado por: Ing. Edwin Ñahuis. Ing. Omar Chumbe.Aprobado por: Ing. Marlon Ly (RPC: 954776510)Versión: 4607226-250815-v252
![Page 2: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/2.jpg)
2
HACER CLICK EN CONFIGURE DEVICE
ADICIONAR EL NUEVO PLC
![Page 3: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/3.jpg)
3
EN ESTE CASO NUESTRO PLC ES UN S7_1200
![Page 4: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/4.jpg)
4
EN NUESTRO CASO ES ESTE MODELO
![Page 5: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/5.jpg)
5
HACER CLICK EN ADD NEW SUBNET
SE CAMBIA EL IP SI FUESE EL CASO
![Page 6: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/6.jpg)
6
SELECCIONAR NETWORK VIEW
HACER CLICK EN CONNECTIONS
![Page 7: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/7.jpg)
7
DAMOS CLICK DERECHO SOBLE EL PLC QUE ESTAMOS INDICANDO
HACEMOS UN CLICK EN ADD NEW CONNECTION
![Page 8: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/8.jpg)
8
NOS SALE LA SIGUIENTE PANTALLA DONDE TENEMOS QUE CAMBIAR *S7 CONECCTION*
![Page 9: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/9.jpg)
9
DESACTIVAR ESTABILISH ACTIVE CONECTION
HACER CLICK EN ADD PARA AGREGAR LA NUEVA CONECCION CON EL LOGO
![Page 10: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/10.jpg)
10
HACEMOS CLICK EN CONNECTIONS
HACER CLICK EN PROPERTIES
![Page 11: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/11.jpg)
11
PONER NOMBRE AL EQUIPO A COMUNICARSE
INGRESAR EL IP EL EQUIPO A COMUNICARSE *PLC*
![Page 12: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/12.jpg)
12
CAMBIAMOS EL *TSAP* TANTO EL LOCAL COMO EL PARTNER EN ESTE CASO PUSIMOS 10.1 PARA EL 1200 Y LOGO=20.00
![Page 13: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/13.jpg)
13
DAMOS UN CLICK
NOS SALE LA SIGUIENTE PANTALLA Y DAMOS CLICK EN *DATA BLOCK*
![Page 14: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/14.jpg)
14
CAMBIAMOS EL DB POR EL NUMERO 2
![Page 15: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/15.jpg)
15
DAMOS CLICK SOBRE DATA BLOCK_2
SE PONE LOS NOMBRE AL DATA BLOCK_2
![Page 16: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/16.jpg)
16
LUEGO COMPILAMOS COMO EN LA IMAGEN PARA QUE NOS GENERE EL OFFSET
![Page 17: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/17.jpg)
17
CON LA SIGUIENTE SECUENCIA HACEMOS UNA SIMULACION
END
![Page 18: Manual Siemens](https://reader033.fdocument.pub/reader033/viewer/2022061617/5695d2431a28ab9b0299b9f9/html5/thumbnails/18.jpg)
18