LLLL’’’’inquinamento da fumo di inquinamento da fumo di ... · Laboratorio per la Ricerca...
Transcript of LLLL’’’’inquinamento da fumo di inquinamento da fumo di ... · Laboratorio per la Ricerca...
LLLL’’’’inquinamento da fumo di inquinamento da fumo di inquinamento da fumo di inquinamento da fumo di
sigaretta negli ambienti sigaretta negli ambienti sigaretta negli ambienti sigaretta negli ambienti
indoor e outdoorindoor e outdoorindoor e outdoorindoor e outdoor
Giovanni InvernizziLaboratorio per la Ricerca Ambientale-SIMG
Laboratorio per la Ricerca sull’Inquinamento da Fumo di Tabacco-Istituto Nazionale dei Tumori/SIMG
Milano
ginverniginverniginverniginverni@@@@clavisclavisclavisclavis....itititit
10
A model of portable analyzer.
� Size:15x8x5 cm
� Weight: 350 g
� Sampling time:� 5 min
� 2 min
� 1 sec
11
A model of portable analyzer.
The instrument operates collecting
data on the field with
instant readable data
on the display, and
can be connected to
a PC where data can
be stored and fully
visualised
Indoor pollution from secondhand smoke
(6 cigarettes smoked in 45m3 room)
CO 7,9 ppmHydrocarbons 3,0 ppmNOX 268,0 ppbRespirable PM (PM3.0) 1.706,0 µµµµg/m3Nicotine 58 “Ammonia 707 “Formaldeide 153 “Acetaldeide 382 “Fenols 20 “Benzene 35 “Toluene 76 “Stirene 8,9 “Etilbenzene 8,8 “
P.R.Nelson, S.P. Kelly, F.W Conrad.
Studies of Environmental Tobacco Smoke Generated by Different CigarettesJ Air Waste Manage Assoc 1998; 48:336-44.
(R.J. Reinolds Tobacco Company, Rowman Gray Technical Center, Winston-Salem, NorthCarolina)
Questi dati eloquenti provengono dai
laboratori di una fonte insospettabile: la multinazionale del tabacco Reynolds Tobacco (Camel)
Questi dati eloquenti provengono dai
laboratori di una fonte insospettabile: la multinazionale del tabacco Reynolds Tobacco (Camel)
Indoor vs outdoor: smoking in the bedroom.
SMOKING IN BEDROOM WITHOUT VENTILATION
0
100
200
300
400
500
600
700
20:2
1:40
20:4
5:40
21:0
9:40
21:3
3:40
21:5
7:40
22:2
1:40
22:4
5:40
23:0
9:40
23:3
3:40
23:5
7:40
0:21
:40
0:45
:40
1:09
:40
1:33
:40
1:57
:40
2:21
:40
2:45
:40
3:09
:40
3:33
:40
3:57
:40
4:21
:40
4:45
:40
5:09
:40
5:33
:40
5:57
:40
6:21
:40
time
mic
rog
ram
s/m
3
PM1
PM2,5
PM7
PM10
TSP
Cig. Smoked
Outdooralarm level
Resuspended coarse
particulate matter generated by the person entering in the
bedroom and bed preparation
Fine particulate matter
generated by cigarettes
Invernizzi G, et al. Am J Respir Crit Care Med 2003; 167 suppl A507
Results 1.Hospitality industry.1
Air quality in a representative pizza-restaurant in downtown Milan.
"Premiata Pizzeria" - Pizza and restaurant- Milan 01.14.03
High outdoor city pollution explains high PM values at opening,
Peak PM10 levels of 1,200 m cg/m 3 were reached late in the night.
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
19.56.3
320.0
4.33
20.12.3
420.2
0.34
20.28.3
520.3
6.35
20.44.3
620.5
2.36
21.00.3
721.0
8.38
21.16.3
821.2
4.39
21.32.3
921.4
0.40
21.48.4
021.5
6.41
22.04.4
122.1
2.42
22.20.4
322.2
8.43
22.36.4
422.4
4.44
22.52.4
523.0
0.45
23.08.4
623.1
6.46
23.24.4
723.3
2.47
tim e
pm
mg
/m3
PM 1.0 m g/m 3
PM 2.5 m g/m 3
PM 7.0 m g/m 3
PM 10.0 m g/m 3
TSP m g/m 3
Invernizzi G, et al. Am J Respir Crit Care Med 2003; 167 suppl A506
Results 1.Hospitality industry.2
24 hours indoor air quality is worse than outdoors’ inside an exclusive Milan downtown restaurant (“Solferino’s”) where smoking is allowed.
Invernizzi G, et al. Am J Respir Crit Care Med 2003; 167 suppl A504
Results 1.Hospitality industry.4
PM concentrations in a disco club.
PARTICULATE MATTER GENERATED BY CIGARETTES IN A DISCO CLUB
0
100
200
300
400
500
600
700
800
00,3
0,31
00,4
0,31
00,5
0,31
01,0
0,31
01,1
0,31
01,2
0,31
01,3
0,31
01,4
0,31
01,5
0,31
02,0
0,31
02,1
0,31
02,3
3,13
time
mic
rog
ram
s/m
3
PM1
PM2,5
PM7
PM10
TSP
Outdooralarm level
Invernizzi G, et al. Am J Respir Crit Care Med 2003; 167 suppl A503
Figura 1. L’inquinamento indoor da polveri sottili prodotte dal fumo di tabacco in un ufficio con impianto di ventilazione in funzione
0
1000
2000
3000
4000
5000
6000
11,15,40 11,20,40 11,25,40 11,30,40 11,35,40 11,40,40 11,45,40 11,50,40 11,55,40 12,00,40 12,05,40 12,10,40
time
mc
g/m
3
PM1
PM2,5
PM7
PM10
TSP
Invernizzi G, et al. Epidem Prev, 2002.
Accensione sigaretta
Results 2.Transportations.1
Smoking in the car exposes to huge PM concentrations.
Invernizzi G, et al. Am J Respir Crit Care Med 2003; 167 suppl A502
Results 1.Hospitality industry.3
“Old Naples” pizza and restaurant. Physically separated smoking and non smoking areas with independent ventilation: a quite good air quality control.
0
50
100
150
200
250
300
350
400
4501
9,4
5,3
8
19
,55
,38
20
,05
,38
20
,15
,38
20
,25
,38
20
,35
,38
20
,45
,38
20
,55
,38
21
,05
,38
21
,15
,38
21
,25
,38
21
,35
,38
21
,45
,38
21
,55
,38
22
,05
,38
22
,15
,38
22
,25
,38
22
,35
,38
22
,45
,38
22
,55
,38
23
,05
,38
23
,15
,38
23
,25
,38
23
,35
,38
23
,45
,38
23
,55
,38
ora
PM
mc
g/m
3
PM1
PM2,5
PM7
PM10
TSP
smoking area
non smoking areanon smoking
area
Invernizzi G, et al. Am J Respir Crit Care Med 2003; 167 suppl A501
Results 2.Transportations.2
PM pollution permeates from smoking towards non smoking coaches.
PM and CO levels in smoking and non-smoking coaches
on a long-distance train
0
100
200
300
400
500
16.2
516
.50
17.1
517
.45
18.1
519
.00
19.1
519
.30
19.4
020
.00
20.1
020
.20
20.3
020
.40
time
PM
mc
g/m
3
0
1
2
3
4
5
CO
pp
m
PM10
PM2.5
PM1
CO ppm
Non-smoking coach
(no t immediately c lo s e
to the s mo king co ach)
Non-smoking co ach with
autho matic s liding do o rs c lo s e to
the s mo king co ach
Smoking
coach
Invernizzi G, et al. Tobacco Control, 2004.
0
100
200
300
400
500
600
700
PM
mcg
/m3
7.4
3.0
6
8.1
7.0
9
8.5
1.1
3
9.2
5.1
4
9.5
9.1
7
10.3
3.1
9
11.0
7.2
1
11.4
1.2
3
12.1
5.2
6
12.4
9.2
8
13.2
3.3
0
13.5
7.3
3
14.3
1.3
5
15.0
5.3
7
15.3
9.3
9
16.1
3.4
1
16.4
7.4
4
17.2
1.4
6
17.5
5.4
8
18.2
9.5
0
19.0
3.5
3
19.3
7.5
5
20.1
1.5
7
20.4
6.0
0
21.2
0.0
2
21.5
4.0
4
22.2
8.0
6
23.0
2.0
9
23.3
6.1
1
0.1
0.1
3
0.4
4.1
5
1.1
8.1
8
1.5
2.2
0
Time
24h monitoring personal exposure to PM
in a patient with coronary artery disease
PM 10
PM 2.5
PM 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14
PM Personal monitoring
Invernizzi G, et al. Am J Respir Crit Care Med 2003; 167 suppl A500
Indoor vs outdoor PM2.5 (mcg/m3) indoor vs outdoor before and after the implemetation of smoking ban.
Jan-Feb 2004 Jan-Feb 2005
Site of monitoring Indoor Outdoor ∆* Indoor Outdoor ∆* % PM2.5 reduction**
Barrios Cafè 709 180 109 31 600 141 281 101 7.2 40
2 94
Belluccio 187 52 134 4.8 53 15.9 7.71 13.8 2.1 2.12 96
Officina della Birra 269 156 26 5.4 243 63 251 16 2.5 472 81
Solferino 190 125 65 11 125 24 101 9 2.5 15
2 88
*Absolute differences between indoor and outdoor means
1 P<0.0001 (Student’s t-test indoor 2005 vs 2004)
2 P<0.0001 (Student’s t-test ∆ 2005 vs 2004)
Indoor vs outdoor pollution in public place in Milan before and after the implementation of
Italian smoking ban
Ruprecht A, Boffi R, Invernizzi G. Epidem Prev, 2007.La legge antifumo ha
comportato netti miglioramenti nella qualitàdell’aria nei locali pubblici
La legge antifumo ha comportato netti
miglioramenti nella qualitàdell’aria nei locali pubblici
General overview
0
20
40
60
80
100
120
140
160
180
19:5
5:0
1
20:0
0:2
9
20:0
5:5
7
20:1
1:2
5
20:1
6:5
3
20:2
2:2
1
20:2
7:4
9
20:3
3:1
7
20:3
8:4
5
20:4
4:1
3
20:4
9:4
1
20:5
5:0
9
21:0
0:3
7
21:0
6:0
5
21:1
1:3
3
21:1
7:0
1
21:2
2:2
9
21:2
7:5
7
21:3
3:2
5
21:3
8:5
3
21:4
4:2
1
21:4
9:4
9
21:5
5:1
7
22:0
0:4
5
22:0
6:1
3
22:1
1:4
1
22:1
7:0
9
22:2
2:3
7
22:2
8:0
5
22:3
3:3
3
22:3
9:0
1
22:4
4:2
9
22:4
9:5
7
22:5
5:2
5
hour
mic
rog
ram
s p
er
m3
PM diameter: 0.3 - 1.0 micrometers Cigarette smoked
PM1.0 ETS pollution in an outdoor patio restaurant in Milan.
Cigarettes lit by customers
Outdoor Winter Smoking Covered Eating Places - 2
• We measured nicotine concentration in 3 outdoor spaces (6 measurements) with a median value of
8.28 µg/m3
I gazebo non dovrebbero
essere considerati
luoghi aperti…
I gazebo non dovrebbero
essere considerati
luoghi aperti…
0
100
200
300
400
500
600
700
2 6 10 14 18 22 26 30 34 38 42 46 50 54 58 62 66 70 74 78 82 86 90 94 98 102 106 110 114 118 122
Time (min)
PM1e
PM2.5e
PM10e
PM 1d
PM 2.5d
PM 10d
Starting smoldering cigarettes
or idling diesel engine
Background
PM production from ETS (e) and an ecodiesel engine (d)
(three smoldering cigarettes or an idling engine for 30' in a 60m3 garage)
PM
µg
/m3Le sigarette producono più PM di
un motore diesel di ultima generazione
Invernizzi G, et al. Tobacco Control, 2004.
Cade un alibi di molti fumatori:
30’ di fumo di sigaretta a
confronto con 30’ di scarico di un
motore diesel in “folle”: la sigaretta produce molto più
PM del motore.
Cade un alibi di molti fumatori:
30’ di fumo di sigaretta a
confronto con 30’ di scarico di un
motore diesel in “folle”: la sigaretta produce molto più
PM del motore.
Il messaggio sembra
convincente, i media
sottolineano che mentre l’industria
automobilistica ha fatto
importanti passi avanti
nella riduzione delle
emissioni, le sigarette
diventano gli strumenti
principali di inquinamento
Il messaggio sembra
convincente, i media
sottolineano che mentre l’industria
automobilistica ha fatto
importanti passi avanti
nella riduzione delle
emissioni, le sigarette
diventano gli strumenti
principali di inquinamento
Un messaggio che la Lega Tumori di Ginevra utilizza
con manifesti sui pullman per
sottolineare che una piccola
sigaretta inquina 10 volte più di un
autobus
Un messaggio che la Lega Tumori di Ginevra utilizza
con manifesti sui pullman per
sottolineare che una piccola
sigaretta inquina 10 volte più di un
autobus
Fumare 1000 sigarette e inquinare la zona pedonale di
via Fiori Chiari causando livelli di PM10 superiori a quelli
di via Pontaccio, con un traffico di oltre 2000 macchine…
Fumare 1000 sigarette e inquinare la zona pedonale di
via Fiori Chiari causando livelli di PM10 superiori a quelli
di via Pontaccio, con un traffico di oltre 2000 macchine…
In blu i superamenti serali del PM in via
Fiori Chiari
In blu i superamenti serali del PM in via
Fiori Chiari
In blu il superamento serali del PM in via Fiori Chiari il sabato sera.
Da notare il PM1.0: nulla di strano, il fumo di sigaretta è composto prevalentemente da
particelle inferiori a 1 um di diametro…
In blu il superamento serali del PM in via Fiori Chiari il sabato sera.
Da notare il PM1.0: nulla di strano, il fumo di sigaretta è composto prevalentemente da
particelle inferiori a 1 um di diametro…
Table 4. Number of smokers recorded in Fiori Chiari
St. vs number of cars crossing Pontaccio St. in the
same time window (08.00 p.m. - 02.00 a.m.).
Number of smokers in
Fiori Chiari St.
1396
Number of cars in
Pontaccio St.
2513
Sigarette vs tubi di scappamento: peggio le
sigarette…
Sigarette vs tubi di scappamento: peggio le
sigarette…
Outdoor nicotine concentrations
in Fiorichiari St. and Pontaccio St.
Fiorichiari St. 0.07 ug/m3
Pontaccio St. below detection limit
Anche il marcatore specifico dl fumo di tabacco, la nicotina
ambientale, era misurabile in Via
Fiori Chiari, a differenza di Via
Pontaccio
Anche il marcatore specifico dl fumo di tabacco, la nicotina
ambientale, era misurabile in Via
Fiori Chiari, a differenza di Via
Pontaccio