September 2012 18002313990 Intelligent Flushing (black section, page 4) Automatic Flushing (red section, page 8) Yard Hydrants (yellow section, page 40) Sampling Stations (green section, page 32) Manual BlowOffs (blue section, page 18) Ratcheting Valve Wrench (see page 28) 18002313990 www.hydrants.com [email protected] 3142312829 fax Water Main Flushing Hydrants Automatics • Post • BlowOff Bacteriological Sampling Stations Dedicated Site • Meter Box • Valve Box

description

Product catalog for Kupferle Foundry

Transcript of Kupferle Foundry Catalog - September 2012

Page 1: Kupferle Foundry Catalog - September 2012

September 2012

1‐800‐231‐3990

Intelligent Flushing(black section, page 4)

Automatic Flushing(red section, page 8)

Yard Hydrants(yellow section, page 40)

Sampling  Stations(green section, page 32)

Manual Blow‐Offs(blue section, page 18)

Ratcheting Valve Wrench(see page 28)

1‐800‐231‐3990 • www.hydrants.com • [email protected] • 314‐231‐2829 fax     

Water  Main Flushing HydrantsAutomatics • Post • Blow‐Off

Bacteriological Sampling StationsDedicated Site • Meter Box • Valve Box

Page 2: Kupferle Foundry Catalog - September 2012

It was 1857, the year of the historic Dred Scott decision,  when John C. Kupferle  founded The Kupferle Foundry Company in St Louis, Missouri.  For over 150 years, The Kupferle Foundry Company has been making quality products for the waterworks industry andbeen making quality products for the waterworks industry and continues to  be the leader in innovation. Our Eclipse line of 

products have been an industry standard since the 19th century and along with our MainGuard, Truflo, Total Eclipse , Corn King and new Eclipse i‐Series product lines The Kupferle Foundry 

Company continues to deliver the best in quality and performance with ease of maintenance. 

Manufacturer ofManufacturer of 

Intelligent Flushing ‐ Automatic Flushing ‐ Sampling Stations ‐Manual Blow‐offs ‐ Yard Hydrants ‐Washdown Hydrants

Page 3: Kupferle Foundry Catalog - September 2012

Table of ContentsIntelligent Flushing

Eclipse i‐Series• Model #9700i  page 4• Model #9800i page 6

Table of ContentsWater Sampling Stations

Eclipse• Model #88  page 32• Model #88‐SS   page 33

d lModel #9800i  page 6• Model #9800WC‐i  page 7

Automatic & Continuous Flushing

Eclipse• Model #9400  page 8• Model #9400WC page 9

• Model #88WC  page 34• Model #88WC‐SS  page 35• Model #82  page 38

MainGuard• Model #66  page 36• Model #66WC  page 37• Model #94WM  page 39

Model #9400WC  page 9• Model #9700  page 10• Model #9700 Accessories  page 11• Model #9800  page 12• Model #9800WC  page 13

MainGuard• Model #5100  page 14• Model #5200  page 15

Water Quality Stations

Eclipse• Model #9900  page 40• Model #9900WC‐2  page 41

Manual Flushing

Eclipse• Model #2 Post Hydrant  page 16• Model #85  page 17• Model #8 Post Hydrant  page 18R t h ti V l W h (RVW) 26

Yard Hydrants

Total Eclipse• Model #1  page 42• Model #7  page 43• Model #36 Street Washer  page 44• Model #3400 Companion  page 45

• Ratcheting Valve Wrench (RVW)  page 26

MainGuard• Model #77 Blow‐Off  page 20• Model #78 Blow‐Off  page 21• Model #7500 Blow‐Off  page 22• Model #7600 Blow‐Off  page 23 

Truflo• Model #TF500 page 27

Corn King• Model #903  page 46• Model #909  page 47

Additional Information• Kupferle Overview  inside front cover 

• Model #TF500  page 27• Model #TF550  page 28• Model #TF800  page 29• Model #TF200  page 30• Model #TF300  page 31

• Kupferle’s Green Initiative  page  2• Water Saving Calculator  page 3• Cost Saving Calculator  page 5• Flushing versus Fire Hydrants  page 24‐25• Flushing Flow Rate Chart page 19• Novelty Items  page 48• Ordering Info/Quality Assurance  inside back cover

Page 4: Kupferle Foundry Catalog - September 2012

Kupferle’s Green InitiativeKupferle s Green Initiative

Kupferle’s full line of intelligent and automatic flushing devices help the environment by conserving water (up to 50% less water usage 

Automatic Flushing Helps Conserve Our Water Resources

compared to manual flushing) when flushing to raise chlorine residual levels and remove disinfectant byproducts (DBPs).  Better water for consumers, less water wasted…now that’s a good thing for all of us! See the water and cost benefit calculators on pages  3 and 5 be sure to look for the EnviroGreen™ label on water‐saving Kupferle products to start saving water, time and money!

Kupferle Automatic Flushing Products

Intelligent Flushing Automatic FlushingEclipse i‐Series #9700i  page 4 Eclipse #9400  page 8p p g p p gEclipse i‐Series #9800i  page 6 Eclipse #9400WC  page 9Eclipse i‐Series #9800WC‐I  page 7 Eclipse #9700  page 10

Eclipse #9800  page 12Eclipse #9800WC  page 13

Now EPA     Approved!In April 2010, the EPA categorically approved portable and permanent automatic flushing devices (Attachment 2—2010 Clean Water and Drinking Water State Revolving Fund,  Part B‐DWSRF 2.2‐11) for their Green Project Reserve Funding Program. Public Water Systems (PWS) can now apply for j g g y ( ) pp yfunding in the form of grants or low‐interest and long‐term loans to install automatic flushing devices in order to start saving water, time and money (see water‐saving calculator on page 3)!

The Green Project Reserve Funding Program (GPR) is designated by the EPA to promote green infrastructure by funding projects and products that provide water and energy efficiency improvements. The EPA requires that a minimum of 20% of the funds made available to each state’s Drinking Water State Revolving Fund (DWSRF) capitalization grants be used by the state for projectsDrinking Water State Revolving Fund (DWSRF) capitalization grants be used by the state for projects to address green infrastructure, water or energy efficiency improvements, or other environmentally innovative activities. For more information, go to www.hydrants.com /envirogreen

21‐800‐231‐3990 / www.hydrants.com

Page 5: Kupferle Foundry Catalog - September 2012

Kupferle’s Green InitiativeKupferle s Green Initiative

show

s og

reen

gs c

alcu

lato

r tha

t dr

ants

.com

/env

irod

this

wat

er-s

avin

ggs

go

to w

ww

.hyd

To d

ownl

oad

wat

er s

avin

g

31‐800‐231‐3990 / www.hydrants.com

Page 6: Kupferle Foundry Catalog - September 2012

I t lli t Fl hiEclipse i‐Series #9700iIntelligent Portable Automatic Hydrant Flushing Device

Intelligent Flushing

ng The Eclipse i‐Series model #9700i is one of the many

ellig

ent F

lush

in The Eclipse i Series model #9700i is one of the many new intelligent flushing devices Kupferle offers to maintain safe residual levels and remove DBPs from consumer’s water. This portable analytical device easily attaches to any fire hydrant (2½” NST) and incorporates a built‐in chlorine analyzer to measure and record disinfectant residual levels based on a programmed sampling schedule. Using the Programmable Logic 

Inte p g g g g

Control (PLC) interface, users can input minimum and desired residual levels, initial blow‐off times and maximum flushing durations. The unit will then operate under these parameters and will flush only when residuals fall below minimum prescribed levels and flush only the exact amount of water until desired residuals are attained.  All residual and flushing data is captured on  PLC allows users to a micro‐SD card or can be transmitted via telemetry or SCADA device.  Since this unit is portable, data from this unit can be used to maximize manual and/or automatic flushing efficiency.

Standard Features •2‐1/2” NST Inlet•Programmable Logic Controller (PLC)

program minimum and maximum residual levels, initial blow-off times and

maximum flushing duration.

Programmable Logic Controller (PLC) •2” Automatic Fail‐Safe Solenoid Operated Valve•Free or Combined Amperometric Chlorine Analyzer           (no reagents required)•Flow Adjustment (up to 200 gpm)•Two Micro‐SD Cards and Two Standard SD Adapters•Powder‐Coated Aluminum Lockable Enclosure w/Key •120VAC or 24VDC Rating Available

Additional Options and Accessories•24VDC Power Box Option•Sampling Point Bibb•Multi‐Directional Diverter •Security Swivel Collar Lock  

Approx. shipping weight 70 lbs.

See page 2

Specification sheets and additional resources are available at 

www.hydrants.com/products

Approx. shipping weight 70 lbs.

1‐800‐231‐3990 / www.hydrants.com4

24VDC Power Unit Detaches Easily for Recharging

Page 7: Kupferle Foundry Catalog - September 2012

Kupferle’s Savings InitiativeKupferle s Savings Initiative

Intelligent Flushi

show

s og

reen

ng

t ca

lcul

ator

that

sdr

ants

.com

/env

irod

our c

ost-b

enef

itgs

go

to w

ww

.hyd

To d

ownl

oado

llar s

avin

g

1‐800‐231‐3990 / www.hydrants.com5

Page 8: Kupferle Foundry Catalog - September 2012

I t lli t Fl hiEclipse i‐Series #9800iIntelligent Automatic Flushing Device for Cold Climates

Intelligent Flushing

ng The Eclipse i‐Series model #9800i is one of the many new

ellig

ent F

lush

in The Eclipse i Series model #9800i is one of the many new intelligent flushing devices Kupferle offers to maintain safe residual levels and remove DBPs from consumer’s water. This permanently installed device incorporates a built‐in chlorine analyzer to measure and record disinfectant residual levels based on a programmed sampling schedule. Using the Programmable Logic Control (PLC) interface, users can input minimum and desired residual levels initial blow

Inte can input minimum and desired residual levels, initial blow‐

off times and maximum flushing durations. The unit will then operate under these parameters and will flush only when residuals fall below minimum prescribed levels and flush only the exact amount of water until desired residuals are attained.  All residual and flushing data is captured on a micro‐SD card or can be transmitted via telemetry or SCADA d i Th l l h i l i i f R 9 ddevice.  Thermal enclosure has a insulation rating of R‐9 and is equipped with 120VAC heater. Sampling lines are heated using  self‐regulating heat trace. Unit is self‐draining, non‐freezing based on depth of bury and is maintainable from above ground – no digging!

R-9 thermal enclosure

Flushing valve and drain located below freeze line

Standard Features •3’ Depth of Bury•Programmable Logic Controller (PLC) •2” Automatic Fail‐Safe Solenoid Operated Valve•Free or Combined Amperometric Chlorine Analyzer (no reagents required)

•Flow Adjustment (up to 200 gpm)

PLC allows users to program minimum and

maximum residual levels, initial blow-off times and

maximum flushing duration.

•Two Micro‐SD Cards and Two Standard SD Adapters•SCADA Compatible•120VAC High Performance Heater with Fan •Self‐Regulating Heat Trace•R‐9 Rated Lockable Thermal Enclosure •120VAC rating

Additional Options and AccessoriesSee page 2 Additional Options and Accessories•Depths of Bury over 3’•Dechlorination Tablet Basket or Inline Option •Low‐Lead Brass

Approx. shipping weight 70 lbs.

See page 2

1‐800‐231‐3990 / www.hydrants.com

Specification sheets and additional resources are available at 

www.hydrants.com/products

6

Page 9: Kupferle Foundry Catalog - September 2012

I t lli t Fl hiEclipse i‐Series #9800WCiIntelligent Automatic Flushing Device for Warm Climates

Intelligent Flushing

In

The Eclipse i‐Series model #9800i is one of the many new telligent Flushi

The Eclipse i Series model #9800i is one of the many new intelligent flushing devices Kupferle offers to maintain safe residual levels and remove DBPs from consumer’s water. This permanently installed device incorporates a built‐in chlorine analyzer to measure and record disinfectant residual levels based on a programmed sampling schedule. Using the Programmable Logic Control (PLC) interface, users can input minimum and desired residual levels initial blow ngcan input minimum and desired residual levels, initial blow‐off times and maximum flushing durations. The unit will then operate under these parameters and will flush only when residuals fall below minimum prescribed levels and flush only the exact amount of water until desired residuals are attained.  All residual and flushing data is captured on a micro‐SD card or can be transmitted via telemetry or SCADA d i Th i i h d i UV i l k bl

Standard Features •1’ Depth of Bury•Programmable Logic Controller (PLC)

device.  The unit is housed in a UV‐resistant lockable enclosure. Lockable

UV-Resistant Enclosure

Programmable Logic Controller (PLC) •2” Automatic Fail‐Safe Solenoid Operated Valve•Free or Combined Amperometric Chlorine Analyzer (no reagents required)•Flow Adjustment (up to 200 gpm)•Two Micro‐SD Cards and Two Standard SD Adapters•120VAC or 24VDC rating available

PLC allows users to program minimum and

maximum residual levels, initial blow-off times and

maximum flushing duration.

Additional Options and Accessories•Depths of Bury over 3’•24VDC Solar Power Package•Dechlorination Tablet Basket or Inline Option •Low‐Lead Brass      

Approx. shipping weight 70 lbs.

1‐800‐231‐3990 / www.hydrants.com

Specification sheets and additional resources are available at 

www.hydrants.com/products

7

See page 2

Page 10: Kupferle Foundry Catalog - September 2012

A t ti & C ti Fl hiEclipse #9400Permanent Automatic Flushing Device for All Climates

Automatic & Continuous Flushing

The Eclipse #9400 Automatic Flushing device is designed andThe Eclipse #9400 Automatic Flushing device is designed and engineered specifically for automatic flushing in all climates. The permanently installed #9400 provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) so as to keep water safe for consumers. The #9400 can be easily installed on a main waterline and flushes directly to the ground A 1” option isuo

us F

lush

ing

waterline and flushes directly to the ground. A 1  option is also available with flow rates up to 65 gallons per minute.

The Eclipse  #9400 comes standard with a UV resistant locking cover. Each unit contains a double valve, all brass sampling point, UV resistant ground plate, solenoid valve and self contained digital controller. The #9400 allows for 12 flushing cycles per day at up to 6 hours of flush time per m

atic

& C

ontin

cycle. Operates on one 9‐Volt battery (compartment holds two batteries). The Eclipse  #9400 is self‐draining, non‐freezing and is fully serviceable from above ground – no digging required!

Standard Features

Aut

o

•3’ Bury•2” FIP Inlet•Self Draining, Non‐Freezing•2”Automatic Valve, Controller, Battery•Above‐Grade Flow Adjustment•UV Resistant Cover and Base

Additional Options

Easy‐to‐program Digital Controller

Additional Options•Any Depths of Bury Over 3’•Optional 1” Model #9400‐A •Dechlorination Tablet Basket•2” Debris Flushing Pipe•1” Debris Flushing Pipe•Low‐Lead Brass 

See Page 21” Model = Approx. shipping weight 55 lbs. for 3ft. Bury2” Model = Approx. shipping weight 65 lbs. for 3ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

g

2” Debris Flushing Pipe

81‐800‐231‐3990 / www.hydrants.com

Page 11: Kupferle Foundry Catalog - September 2012

A t ti & C ti Fl hiEclipse #9400WC Permanent Automatic Flushing Device for Warm Climates

Automatic & Continuous Flushing

The Eclipse #9400WC Automatic Flushing device is designedThe Eclipse #9400WC Automatic Flushing device is designed and engineered specifically for automatic flushing in warm climates. The permanently installed #9400WC provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) so as to keep water safe for consumers. The #9400WC can be easily installed on a main waterline and flushes directly to the ground A 1” option is

Autom

atic & C

waterline and flushes directly to the ground. A 1  option is also available with flow rates up to 65 gallons per minute.

The Eclipse  #9400WC comes standard with a UV resistant locking cover. Each unit contains a double valve, all brass sampling point, UV resistant ground plate, solenoid valve and self contained digital controller. The #9400WC allows for 12 flushing cycles per day at up to 6 hours of flush time per 

ontinuous Flus

cycle. Operates on one 9‐Volt battery (compartment holds two batteries). The Eclipse  #9400WC is fully serviceable from above ground – no digging required!

Standard Features •1’ Bury•2” MIP Inlet

hing

•Non‐Draining•2” Automatic Valve, Controller, Battery•Above‐Grade Flow Adjustment•UV Resistant Cover and Base

Additional Options•Optional 1” Model #9400WC‐A•Dechlorination Option

Easy‐to‐program Digital Controller

•Dechlorination Option

1” Model = Approx. shipping weight 55 lbs. for 1 ft. Bury2” Model = Approx. shipping weight 65 lbs. for 1 ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

See Page 2

91‐800‐231‐3990 / www.hydrants.com

Page 12: Kupferle Foundry Catalog - September 2012

A t ti & C ti Fl hiAutomatic & Continuous Flushing

The Eclipse #9700 Portable Automatic Flushing device is 

Eclipse #9700 Portable Automatic Hydrant Flushing Device

designed and engineered specifically for automatic flushing in all climates. The portable #9700 easily attaches to any 2½” NST outlet and provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) so as to keep water safe for consumers. The #9700 can be easily installed onto any 2½ NST fire hydrant or flushing blow‐off outlet,  uo

us F

lush

ing

flushing water directly to the ground. A 1” option is also available with flow rates up to 65 gallons per minute.

The Eclipse  #9700 comes standard with a powder‐coated aluminum locking enclosure. Each unit  includes a solenoid valve and self contained digital controller. The #9700 allows for 12 flushing cycles per day at up to 6 hours of flush time per cycle. Operates on one 9‐Volt battery (compartment m

atic

& C

ontin

pe cyc e Ope ates o o e 9 o t batte y (co pa t e tholds two batteries). The Eclipse  #9700 is designed to operate during non‐freezing seasons and is easily stored in the winter. Collar lock, directional diverter and other optional accessories are available (see page 11).

Standard Features •2‐1/2” NST Inlet

See Page 21” Model #9700‐A 

Aut

o

•2” Automatic Valve, Controller, Battery•Powder‐Coated Aluminum Lockable Box

Additional Options and Accessories•Multi‐Directional Diverter •Sampling Point Bibb•Collar Lock (red or yellow)•Dechlorination Tablet Basket

Easy‐to‐program Digital Controller

•Dechlorination Tablet Basket•Meter Stand•1” Model #9700‐A • Special Threads Available

1” Model = Approx. shipping weight 15 lbs.2” Model = Approx. shipping weight 25 lbs.

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

101‐800‐231‐3990 / www.hydrants.com

Page 13: Kupferle Foundry Catalog - September 2012

A t ti & C ti Fl hiEclipse #9700 Accessories Accessories for your #9700 Flushing Unit

Automatic & Continuous Flushing

Kupferle Foundry offers several accessories to go with its best‐selling Eclipse #9700 and #9700‐A portable automatic flushing devices.  From multi‐directional diffusers, meter stands, dechlorination option sampling bibbs to

Autom

atic & C

Multi‐Directional Diverter

dechlorination option, sampling bibbs to security collar locks. Kupferle provides numerous quality accessories to choose from!

ontinuous Flus

Water Meter Stand

hing

Dechlorination BasketSampling Bibb

Security Collar Lock

Serving the Waterworks Industry for over 150 years!

111‐800‐231‐3990 / www.hydrants.com

Page 14: Kupferle Foundry Catalog - September 2012

A t ti & C ti Fl hiEclipse #9800 Permanent Automatic Flushing device for All Climates

Automatic & Continuous Flushing

The Eclipse #9800 Automatic Flushing device isThe Eclipse #9800 Automatic Flushing device is designed and engineered specifically for automatic flushing in all climates. The permanently installed #9800 provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs), so as to keep water safe for consumers The #9800 can be easily installed on auo

us F

lush

ing

consumers. The #9800 can be easily installed on a main waterline and flushes underground directly to a sanitary sewer, storm sewer or culvert. A 1” option is also available with flow rates up to 65 gallons per minute.

The Eclipse  #9800 comes standard with a UV‐resistant locking cover. Each unit contains a double m

atic

& C

ontin

Lockable UV Resistant

valve, all brass sampling point, solenoid valve and self contained digital controller. The #9800 allows for 12 flushing cycles per day at up to 6 hours of flush time per cycle. Operates on one 9‐Volt battery (compartment holds two batteries). The Eclipse  #9800 is self‐draining, non‐freezing and is fully serviceable from above ground – no digging 

Standard Features•3’ Bury•2” FIP Inlet

Aut

o

Easy‐to‐program Digital Controller

UV-Resistant Enclosure

g gg grequired! •Self Draining, Non‐Freezing

•2”Automatic Valve, Controller, Battery•Above Grade Flow Adjustment•UV Resistant Lockable Cover and Key

Additional Options and Accessories•Any depths of Bury over 3’• 1” Model #9800‐A1  Model #9800 A• Dechlorination Tablet Basket• 2” Debris Flushing Pipe • 1” Debris Flushing Pipe•Additional keys 

1” Model = Approx. shipping weight 55 lbs. for 3ft. Bury

See Page 2

2” Debris Flushing Pipe

2” Model = Approx. shipping weight 65 lbs. for 3ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

121‐800‐231‐3990 / www.hydrants.com

Page 15: Kupferle Foundry Catalog - September 2012

A t ti & C ti Fl hiEclipse #9800WC Permanent Automatic Flushing device for Warm Climates

Automatic & Continuous Flushing

The Eclipse #9800WC Automatic Flushing device isThe Eclipse #9800WC Automatic Flushing device is designed and engineered specifically for automatic flushing in warm climates. The permanently installed #9800WC provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) so as to keep water safe for consumers The #9800WC can be easily

Autom

atic & C

safe for consumers. The #9800WC can be easily installed on a main waterline and flushes  underground directly to a sanitary sewer, storm sewer or culvert. A 1” option is also available with flow rates up to 65 gallons per minute.

The Eclipse  #9800WC comes standard with a UV‐resistant locking cover. Each unit contains a double 

ontinuous Flus

valve, all brass sampling point, solenoid valve and self contained digital controller. The #9800WC allows for 12 flushing cycles per day at up to 6 hours of flush time per cycle. Operates on one 9‐Volt battery (compartment holds two batteries). The Eclipse  #9800WC is fully serviceable from above ground – no digging required!

hing

Easy‐to‐program Digital Controller

Lockable UV-Resistant

Enclosure

g gg g qStandard Features •1’ Bury•2” MIP Inlet•Non ‐ Draining                                                •2” Automatic Valve, Controller, Battery•Above Grade Flow Adjustment•UV Resistant Lockable Cover and Key

Additional Options and Accessories•1” Model #9800WC‐A•Dechlorination Tablet Basket•Spare Key, #9812

Approx. shipping weight 65 lbs. for 1 ft. Bury

See Page 2

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

131‐800‐231‐3990 / www.hydrants.com

Page 16: Kupferle Foundry Catalog - September 2012

A t ti & C ti Fl hiMainGuard #5100Permanent Continuous Flusher for All Climates (in ground)

Automatic & Continuous Flushing

The MainGuard #5100 Continuous Flushing deviceThe MainGuard #5100 Continuous Flushing device provides a continuous flow of water on stagnant dead ends! The #5100 is permanently installed on a water main line and provides an adjustable constant flow to keep chlorine residual levels in water safe and prevent the formation of disinfectant byproducts (DBPs).

The MainGuard  #5100 comes standard with a 3/8” l h d d i l i ll b

uous

Flu

shin

g

male threaded inlet connection, all brass waterway, orifice to control flow of water and provide constant flow, catch basin to discharge water underground, and a lockable UV protected plastic cover. The standard #5100 maintains a constant flow of .1 to 6 GPM. As with all Kupferle products, the Eclipse  #5100 is fully serviceable from above ground – no digging!m

atic

& C

ontin

Aut

o

Standard Features•Buries Direct in Ground with no Flange•Water Inlet Enters from Underneath FlusherWater Inlet Enters from Underneath Flusher•3’ Below Grade Piping Standard

Approx. shipping weight 25 lbs.

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

141‐800‐231‐3990 / www.hydrants.com

Page 17: Kupferle Foundry Catalog - September 2012

A t ti & C ti Fl hiMainGuard #5200Portable Continuous Flusher for All Climates (bolts to meter box lid)

Automatic & Continuous Flushing

The MainGuard #5200 Continuous Flushing device Autom

atic & C

The MainGuard #5200 Continuous Flushing device provides a continuous flow of water on stagnant dead ends! The #5200 is temporarily installed by bolting to a meter box lid and provides an adjustable constant flow to keep chlorine residual levels in water safe and prevent the formation of disinfectant byproducts (DBPs).

Th M i G d #5200 d d i h 3/8”

ontinuous Flus

The MainGuard  #5200 comes standard with a 3/8” male threaded inlet connection, all brass waterway, orifice to control flow of water and provide constant flow, catch basin to discharge water underground and a lockable UV protected plastic cover. The standard #5200 maintains a constant flow of .1 to 6 GPM. As with all Kupferle products, the Eclipse  #5200 is fully  hing

serviceable from above ground – no digging!

Standard Features •Furnished with Four‐Bolt Flange 6” High•Water Connection Enters From Underneath Flusher•Discharge Pipe Exits HORIZONTALLY through Pedestal

Flange has four 1/2” bolt holes at 

5‐9/16” centers

Approx shipping weight 25 lbs.

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

151‐800‐231‐3990 / www.hydrants.com

Page 18: Kupferle Foundry Catalog - September 2012

M l Fl hiEclipse #2 Post Flushing HydrantPermanent Flushing Hydrant for all Climates

Manual Flushing

The Eclipse #2 Post Hydrant is one of the best selling flushing hydrants for water main dead ends. Designed for performance and durability, the Eclipse #2 provides excellent flow rates for improving chlorine residual levels and flushing disinfection byproducts (DBPs) to keep water safe for consumers. 

The Eclipse #2 comes standard with all brass working parts, nozzle sizes up to 2½” NST, self draining, non‐parts, nozzle sizes up to 2½  NST, self draining, nonfreezing, 3’ bury or less, 2‐3/16” valve opening and 1½” pentagon operating nut. Various inlets available (see below). The Eclipse  #2 is fully serviceable from above ground – no digging!

* See flushing flow rate chart on page 19

Flus

hing

Man

ual F

Standard Features•3’ Bury or Less•Any size nozzle up to 2‐1/2” NST

Inlet Options include 2”, 2½”, 3” FIP or 2” 3” 4”Any size nozzle up to 2 1/2  NST

•2‐3/16” Valve Opening •Self Draining, Non‐Freezing•1‐1/2” Pentagon Nut

Additional Options and Accessories•Any Depths of Bury over 3’•2” , 2‐1/2” or 3” FIP Inlet Eclipse #2A

1¼” 1½”

3  FIP or 2 , 3 , 4  MJ

•2”, 3” or 4” MJ Inlet•Two Nozzles of any size up to 2‐1/2” NST•Tamper‐Proof Option•Bolted Flange Top‐Stock•10” Hand Wheel•Multiple Wrenches•Call for Additional Custom Options                                                                                       

1¼” or 1½”also available

Approx. shipping weight 130 lbs. for 3ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

161‐800‐231‐3990 / www.hydrants.com

Page 19: Kupferle Foundry Catalog - September 2012

M l Fl hiEclipse #85 Blow‐Off HydrantPermanent Flushing Hydrant for All Climates

Manual Flushing

The Eclipse #85 Blow‐Off Hydrant is designed and engineered specifically for flushing and provides excellent flow rates for improving chlorine residual levels and flushing disinfection byproducts (DBPs) to keep water safe for consumers.  The #85 Eclipse Blow‐Off Hydrant is designed with a heavy wall cast‐iron box. The box sits at ground level and is not traffic rated.

The Eclipse #85 comes standard with all brass working parts, numerous outlet sizes 2½” NST or smaller, self draining non‐freezing drain, and numerous inlet sizes also available. The Eclipse  #85 is fully serviceable from above ground – no digging!

Manual F

Wrench Sold Separately

* See flushing flow rate chart on page 19

Flushing

Standard Features•3’ Bury or Less•Any Size Nozzle up to 2‐1/2” NSTAny Size Nozzle up to 2 1/2  NST•2‐3/16” Valve Opening•Self Draining, Non‐Freezing•Cast‐Iron Box with Locking Lid

Additional Options and Accessories•Any Depths of Bury over 3’•1‐1/4”, 1‐1/2”, 2”, 2‐1/2”, 3” IP Inlet•2”, 3” or 4” MJ Inlet•Nozzle Cap•Long and Short Handle Wrenches                                                              

Approx. shipping weight 100 lbs. for 3ft. Bury

Inlet Options include 2”, 2½”, 3” FIP or 2”, 3”, 4” 

MJ

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

171‐800‐231‐3990 / www.hydrants.com

Page 20: Kupferle Foundry Catalog - September 2012

M l Fl hiEclipse #8 Post Flushing HydrantPermanent Flushing Hydrant for all Climates

Manual Flushing

The new Eclipse #8 Post Hydrant is designed to deliver performance and durability for flushing water main dead‐ends at a value price. The Eclipse  #8 provides excellent flow rates for improving chlorine residual levels and flushing disinfection byproducts (DBPs) to keep water safe for consumers.

The Eclipse  #8 comes standard with all brass working parts, nozzle size up to 2½” NST, self draining, non‐parts, nozzle size up to 2½  NST, self draining, nonfreezing, 3’ bury or less, 2‐3/16” valve opening and 1½” pentagon operating nut. Various inlets available. As with all Kupferle products, the Eclipse  #8 is fully serviceable from above ground – no digging!

Flus

hing

Man

ual F

Standard Features•3’ Bury or Less•Any size nozzle up to 2‐1/2” NSTAny size nozzle up to 2 1/2  NST•2‐3/16” Valve Opening •Self Draining, Non‐Freezing•1‐1/2” Pentagon Nut

Additional Options and Accessories•Any Depths of Bury over 3’•2” , 2‐1/2” or 3” FIP Inlet•2”, 3” or 4” MJ Inlet•Tamper‐Proof  Option•Bolted Flange Top‐Stock•10” Hand Wheel•Multiple Wrenches•Call for Additional Custom Options                                                                                       

Approx. shipping weight 130 lbs. for 3ft. Bury

Inlet Options include 2”, 2½”, 3” FIP or 2”, 3”, 4” 

MJApprox. shipping weight 130 lbs. for 3ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

181‐800‐231‐3990 / www.hydrants.com

Page 21: Kupferle Foundry Catalog - September 2012

K f l M l Fl hi G id liKupferle Manual Flushing Guidelines

s nfectant guide

lines

e/Ch

loramines

m: 0.5mg/L

m: 4.0 m

g/L

)EPA disin

Chlorine

Minim

umMaxim

um

Manual F

g Ve

locity  (5.0 fps)

pm pm pm 0 gpm

Flushing

Ideal Scouring

4” = 195

.72 gp

6” = 440

.40 gp

8” = 782

.90 gp

10” = 12

23.30

t. of p

ipe eq

uals:

2.42

 gallons

468.00

 gallons

609.70

 gallons

,078

.00 gallons

eet =

 1 m

ile

1000

 ft4” = 65

6” = 1,4

8” = 2,6

10” = 4

5,28

0 fe

191‐800‐231‐3990 / www.hydrants.com

Page 22: Kupferle Foundry Catalog - September 2012

M l Fl hiMainGuard #77 Post Flushing HydrantPermanent Flushing Hydrant for All Climates

Manual Flushing

The MainGuard #77 Blow‐Off provides the best in performance and value. Designed and engineered specifically for flushing, the #77 provides excellent flow rates for improving chlorine residual levels and flushing disinfection byproducts (DBPs) to keep water safe for consumers. The unique valve design allows for a full clear‐channel flow (see illustrations) that is superior to other blow‐offs for moving water and p gpassing debris easily. The #77 plunger is also designed to allow for throttling the flow of water while at the same time covering the drain hole to avoid unnecessary erosion.

The MainGuard #77 comes standard with all brass and aluminum working parts, nozzle sizes up to 2 ½” NST, traffic break away self draining non freezing 2” FIPFl

ushi

ng

traffic break‐away, self draining non‐freezing, 2  FIP vertical (straight) inlet and locking security cover standard.  The MainGuard #77 is fully serviceable from above ground – no digging!

* See flushing flow rate chart on page 19

Man

ual F

Standard Features•3’ Bury or Less•2” FIP Vertical (straight) Inlet•2‐1/2” NST Nozzle (or any size smaller)•Self Draining, Non‐Freezing•All Brass and Aluminum Working Parts•Traffic Break‐Away•Locking Security CoverLocking Security Cover•Slotted Corp Style Operating Nut

Additional Options and Accessories•Any Depths of Bury over 3’•90° Horizontal (side) Inlet•2” MJ Inlet Iron with Epoxy Coating•2” MJ Inlet all Brass ValveO i h

Unique Valve Design Allows for Full“Clear Channel” Flow and Passing of•Operating Wrench

•Low‐Lead Brass

Approx. shipping weight 60 lbs. for 3ft. Bury

Clear Channel  Flow and Passing ofLarge Debris (see flow rates on page 19)

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

201‐800‐231‐3990 / www.hydrants.com

Page 23: Kupferle Foundry Catalog - September 2012

M l Fl hiManual Flushing

The MainGuard #78 Blow‐Off installs underground in a

MainGuard #78 Blow Off HydrantPermanent Flushing Hydrant for All Climates

The MainGuard #78 Blow Off installs underground in a standard meter box. Designed and engineered specifically for flushing, the #78 provides excellent flow rates for improving chlorine residual levels and flushing  disinfection byproducts (DBPs) to keep water safe for consumers. Its unique valve design allows for a full clear‐channel flow (see illustrations) that is superior to other blow offs for moving water and passing debris

Manual

other blow‐offs for moving water and passing debris easily. The #78 plunger is also designed to allow for throttling the flow of water while at the same time covering the drain hole to avoid unnecessary erosion.

The MainGuard #78 comes standard with all brass and aluminum working parts, nozzle sizes 2 ½” NST or smaller, traffic break‐away, self draining non‐freezing,  Flushing

2” FIP vertical (straight) inlet and locking security cover standard. The MainGuard #78 is fully serviceable from above ground – no digging!

* See flushing flow rate chart on page 19

Standard Features•3’ Bury or Less•2” FIP Vertical (straight) Inlet•2‐1/2” NST Nozzle (or any size smaller)•All Brass and Aluminum Working Parts•Self Draining, Non‐Freezing•Installs Underground in Meter Box•Locking Security Cover•Locking Security Cover•Slotted Corp Style Operating Nut

Additional Options and Accessories•Any Depths of Bury over 3’•90º  Horizontal (side) Inlet•2” MJ Inlet Iron with Epoxy Coating•2” MJ Inlet all Brass Valve

Unique Valve Design Allows for Full“Clear Channel” flow and Passing of

Approx. shipping weight 37 lbs.

Large Debris (see Flow rates on page 19)

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

211‐800‐231‐3990 / www.hydrants.com

Page 24: Kupferle Foundry Catalog - September 2012

M l Fl hiMainGuard #7500 Post Flushing HydrantPermanent Flushing Hydrant for All Climates

Manual Flushing

The MainGuard #7500 Blow‐Off Hydrant is designed and engineered specifically for flushing large amounts of water quickly. The unit provides excellent flow rates comparable to  a standard fire hydrant. The MainGuard #7500 Blow‐Off Hydrant accommodates a high flow volume for bio‐film scouring applications and the unique valve design allows for flushing of large debris. The unit provides ample flushing velocities p p gusually at half the cost of a fire hydrant.

The MainGuard #7500 comes standard with all brass and aluminum working parts, 4” inlet and outlet and is self draining and non‐freezing. The MainGuard #7500 is fully serviceable from above ground – no digging!

Flus

hing

* See flushing flow rate chart on page 19

Man

ual F

Standard FeaturesStandard Features•3’ Bury•4” MJ Inlet•4” FIP Outlet with Plug•Self Draining, Non ‐Freezing

Additional Options and Accessories•Any Depths of Bury over 3’•6” MJ Inlet•Locking Cap Feature

Approx. shipping weight 100 lbs. for 3ft. Bury Unique Valve Design Allows for Full“Clear Channel” Flow and Passing of

Large Debris (see flow rates on page 19)Large Debris (see flow rates on page 19)

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

221‐800‐231‐3990 / www.hydrants.com

Page 25: Kupferle Foundry Catalog - September 2012

M l Fl hiManual Flushing

The MainGuard  #7600 Blow‐Off Hydrant installs 

MainGuard #7600 Blow Off HydrantPermanent Flushing Hydrant for All Climates

underground in a meter box and is designed and engineered specifically for flushing large amounts of water quickly. The unit provides excellent flow rates comparable to  a standard fire hydrant. The MainGuard #7600 Blow‐Off Hydrant accommodates a high flow volume for bio‐film scouring applications and its unique valve design allows for flushing of large debris. The unit 

Manual

g g gprovides ample flushing velocities usually at half the cost of a fire hydrant.

The MainGuard  #7600 comes standard with all brass and aluminum working parts, 4” inlet and outlet and is self draining and non‐freezing. The MainGuard #7600 is fully serviceable from above ground – no digging!

Flushing

* See flushing flow rate chart on page 19

Standard Features•3’ Bury•4” MJ Inlet•4” FIP Outlet with Plug•Self Draining, Non–Freezing

Additional Options and Accessories•Any Bury Depths over 3’

Unique Valve Design Allows for Full“Clear Channel” Flow and Passing of

•Any Bury Depths over 3  •6”MJ Inlet•Locking Feature•Lid for 12” Sewer Pipe

Approx. shipping weight 90lbs.

Large Debris (see Flow rates on page 19)

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

231‐800‐231‐3990 / www.hydrants.com

Page 26: Kupferle Foundry Catalog - September 2012

Fl hi H d t Fi H d tFlushing Hydrants versus Fire HydrantsKupferle offers a better solution to placing expensive fire hydrants on water main dead ends. The MainGuard #7500 and #7600 provides comparable flow rates for flushing and scouring, but usually at g g, yabout half the cost of a fire hydrant. Fire hydrants provide fire protection for 250 feet on either side of the unit, but when placed on dead ends the downstream area of protection is wasted (see illustration below). Additionally, fire departments prefer NOT to have fire hydrants placed at the end of a cul‐de‐sac and residents will enjoy having no above

Flus

hing

cul de sac, and residents will enjoy having no above ground installations or parking issues on their property (MainGuard #7600 below grade fits inside a meter box). 

The MainGuard #7500 and #7600 are specifically engineered for flushing with a unique valve design that allows larger debris to pass versus a fire hydrant. See h b fi l l 27 h

MainGuard #7500 MainGuard #7600

Man

ual F the cost benefit calculator on page 27 to see how 

much you can save using Kupferle’s MainGuard #7500 and #7600 flushing hydrants!

PLAN 1: 1500 foot water main with fire hydrant at dead‐end

PLAN 2: 1250 foot water main with flushing hydrant at dead‐end = $$$ savedPLAN 2: 1250 foot water main with flushing hydrant at dead‐end = $$$ saved

Flushing Hydrant

250

241‐800‐231‐3990 / www.hydrants.com

Page 27: Kupferle Foundry Catalog - September 2012

Fl hi H d t Fi H d tFlushing Hydrants versus Fire Hydrants

Manual sh

ows

ogre

en

Flushing

t ca

lcul

ator

that

sdr

ants

.com

/env

irod

our c

ost-b

enef

itgs

go

to w

ww

.hyd

To d

ownl

oado

llar s

avin

g

251‐800‐231‐3990 / www.hydrants.com

Page 28: Kupferle Foundry Catalog - September 2012

M l Fl hiManual Flushing

The Eclipse RVW is specifically designed to make operating valves easier! With its dual ratcheting feature

Eclipse Ratcheting Valve Wrench (RVW)Ratcheting Valve Wrench with Swivel Action Socket

operating valves easier! With its dual ratcheting feature and swivel action socket, the Eclipse RVW eliminates the need to turn the operating handle 360º. The Eclipse RVW can be made with a solid or telescoping shaft at various lengths up to 20 feet. 

The Speedy Valve Wrench (SVW) can be made as a stand alone wrench or as an attachment to the RVW.  

NEW

Flus

hing

With its non‐stationary rotating handle for smooth, quick turning the SVW is designed to open valves quickly and easily. 

Standard Features – RVW•Solid Shaft Available

Independently tested up to 777 ft‐lbs. of torque!

Man

ual F

•Solid Shaft Available•Telescoping Shaft Available•Dual Ratcheting Action•Ductile Gear and Pawl•Swivel Action Socket

Additional Options and Accessories•Solid Socket•Custom Lengths Upon Request• Auger (for valve box cleanout)•Attachable 1¼” Pentagon Key•Attachable 1½” Pentagon Key•Attachable 1” Square Key•Attachable 1½” Square Key•Attachable 2” Square Key

NEW

Speedy Valve 

Approx. shipping weight 10 lbs. for 6 ft. telescoping model

Wrench (SVW)

Attachable Swivel Handle

Attachable Pent and 

Square Keys

Attachable Auger for Valve Box Clean Out

261‐800‐231‐3990 / www.hydrants.com

Page 29: Kupferle Foundry Catalog - September 2012

M l Fl hiManual Flushing

The Truflo #TF500 Blow‐Off is designed and engineered

Truflo #TF500 Blow Off (fits inside a 5¼” valve box)

Permanent Flushing for All Climates

The Truflo #TF500 Blow Off is designed and engineered with a slim profile that fits into a standard 5¼” adjustable valve box. The #TF500 provides an alternative to a gate valve, 2” blow‐off assembly with  two valve boxes and is built for frequent exercising and longevity with minimal maintenance. The #TF500 is cast iron, steel, and brass construction with all brass and aluminumworking parts An all brass option (see photo

Manual

aluminum working parts . An all brass option (see photo to the right) is also available.

The Truflo  #TF500 comes standard with a 2” MIP outlet, 2” FIP vertical straight inlet. Horizontal inlet and low‐lead brass options are also available. The Truflo  #TF500 is fully serviceable from above ground – no digging!

Flushing

* See flushing flow rate chart on page 19

Standard Features•3’ Bury or Less•2” MIP Outlet2  MIP Outlet•2” Vertical (straight) Inlet•9/16” Square Operating Nut•Cast Iron Headstock•Fits Inside 5‐1/4” Valve Box•Self Draining, Non‐Freezing

Additional Options and Accessories

When Plunger is Raised, Water Flows Around 

Plunger Housing All i f F ll •Any Bury Depths Over 3’

•2” MJ Inlet Iron Adapter•2” MJ Inlet Brass Adapter•Horizontal Side Inlet•All Brass and Aluminum Model•Epoxy Coated Cast Iron•24” Riser•36” Operating Wrench

Allowing for a Full Dual‐Channel Flow

36  Operating Wrench•Low‐Lead Brass

Approx. shipping weight 35lbs. for 3ft. BurySpec sheets, installation details and additional resources are available at 

www.hydrants.com/products

271‐800‐231‐3990 / www.hydrants.com

Page 30: Kupferle Foundry Catalog - September 2012

M l Fl hiTruflo #TF550 Blow‐Off (fits inside a 5¼” valve box)

Permanent Flushing for Warm Climates

Manual Flushing

The Truflo #TF550 Blow‐Off is designed and engineered with a slim profile that fits into a standard 5¼” adjustable valve box. The #TF550 provides an alternative to a gate valve, 2” blow‐off assembly with  two valve boxes and is built for frequent exercising and longevity with minimal maintenance. The #TF550 is all brass construction with all brass working parts .

The Truflo #TF550 comes standard with a 2” MIPThe Truflo  #TF550 comes standard with a 2  MIP outlet, 2” FIP vertical straight inlet. A low‐lead brass option is also available. The Truflo  #TF550 is fully serviceable from above ground – no digging!

Flus

hing

Man

ual F Standard Features

•2” FIP Inlet•2” MIP Outlet•Non‐Draining•9/16” Square Operating Nut•All Brass Design

Additional Options and Accessories•Epoxy Coated Cast‐Iron•24” Riser •36” Operating Wrench•Low‐Lead Brass

Approx. shipping weight 15 lbs.Approx. shipping weight 15 lbs.

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

281‐800‐231‐3990 / www.hydrants.com

Page 31: Kupferle Foundry Catalog - September 2012

M l Fl hiManual Flushing

The Truflo #TF800 Blow‐Off fits into a standard meter

Truflo #TF800 Blow Off Permanent Flushing for Warm Climates

The Truflo #TF800 Blow Off fits into a standard meter box and provides an alternative to a gate valve, 4” blow‐off assembly. It features all brass construction and working parts.

The Truflo  #TF800 comes standard with a 4” MIP outlet, 4” FIP vertical straight inlet. A Low‐lead brass option is also available. The Truflo  #TF800 is fully serviceable f b d di i !

Manual

from above ground – no digging!

Flushing

Standard Features•4” FIP Inlet•4” MIP Outlet4  MIP Outlet•Non –Draining•All Brass Design•Operates with Corp. Wrench

Additional Options and Accessories•Low‐Lead Brass

Approx. shipping weight 35lbs. for 3ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

291‐800‐231‐3990 / www.hydrants.com

Page 32: Kupferle Foundry Catalog - September 2012

M l Fl hiTruflo #TF200 Blow‐OffPermanent Flushing for All Climates

Manual Flushing

The Truflo #TF200 Blow‐Off is an excellent choice for performance and value. Designed and engineered specifically for flushing, the Truflo TF#200 provides excellent flow rates for improving chlorine residual levels and flushing disinfection byproducts (DBPs) to keep water safe for consumers. The unique valve design allows for a dual‐channel flow (see illustrations) that is superior to other blow‐offs for moving water p gand passing debris easily. The Truflo TF#200 plunger is engineered to cover the drain hole while flushing to avoid unnecessary ground erosion.

The Truflo TF#200 comes standard with all brass and aluminum working parts, outlet nozzle sizes up to 2 ½” NST, 2” vertical inlet (horizontal option available and is self draining non freezing) The Truflo TF#200 is fullyFl

ushi

ng

self‐draining, non‐freezing).  The Truflo TF#200 is fully serviceable from above ground – no digging!

* See flushing flow rate chart on page 19Man

ual F

Standard Features•3’ Bury or Less

When Plunger is Raised, Water Fl A d•2” FIP Inlet

•2½” NST Outlet•Self‐Draining, Non‐Freezing•9/16” Square Operating Nut

Additional Options and Accessories•Any Depths of Bury over 3’•Any Outlet up to 2½” NST

Flows Around Plunger Housing Allowing for a Full Dual‐Channel Flow

Any Outlet up to 2½  NST•Anti‐Vandal Cap•Breakaway Traffic Flange•90° Horizontal (side) Inlet•Operating Wrench•Operating Handle•2” MJ Inlet Iron Adapter•2” MJ Inlet Brass Adapter

Truflo #TF250 is a below grade option 

for the Truflo #TF200 and fits 

inside a meter box

•Low‐Lead Brass

Approx. shipping weight 60 lbs.Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

301‐800‐231‐3990 / www.hydrants.com

Page 33: Kupferle Foundry Catalog - September 2012

M l Fl hiManual Flushing

The Truflo #TF300 Blow‐Off is an excellent choice for

Truflo #TF300 Post Hydrant Permanent Washdown for All Climates

The Truflo #TF300 Blow Off is an excellent choice for washdown  and general use applications on waterlines, water treatment or waste water treatment plants. Designed for washdown, the Truflo TF#300 provides excellent flow rates. The unique valve design allows for a dual‐channel flow (see illustrations) that is superior to other hydrants for moving water at high velocities. The Truflo TF#300 plunger is engineered to cover the drain hole

Manual

Truflo TF#300 plunger is engineered to cover the drain hole while flowing to avoid unnecessary ground erosion.

The Truflo TF#300 comes standard with all brass working parts, 2 ½” NST outlet, 2” vertical inlet and is self‐draining, non‐freezing).  The Truflo TF#300 is fully serviceable from above ground – no digging! Flushing

g gg g

Standard Features•3’ Bury or Less•2” FIP Vertical Inlet•2½” NST Outlet•Aluminum Casing Guard•Bronze Head Stock and Cap•Brass Interior Operating Parts•Bronze Valve Body•Stainless Steel Interior Operating Rod•Stainless Steel Exterior Casing Pipe•Operating Handle

When Plunger is Raised, Water Flows Around 

Plunger Housing Allowing for a Full 

•Operating Handle•Self –Draining, Non‐Freezing

Additional Options and Accessories•Depths of Bury Over 3’•Any nozzle up to 2½” NST•Horizontal Inlet•Brass or Galvanized Interior Operating Rod

Dual‐Channel Flow

•Brass or Galvanized Exterior Casing Pipe•2” MJ Inlet Brass Adapter

Approx. shipping weight 35lbs. for 3ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

311‐800‐231‐3990 / www.hydrants.com

Page 34: Kupferle Foundry Catalog - September 2012

S li St tiEclipse #88 Sampling Station (bacteriological)Permanent Sampling Station for All Climates

Sampling Stations

The Eclipse #88 Sampling Station is designed specifically for collecting bacteriological and other  water samples at a designated point directly from the water main. The #88 provides a 24/7 designated sampling site to retrieve samples at any time versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times, and reduce liability concerns. Sampling stations have been approved for use in the EPA’s Total Coliform Rulethe EPA’s Total Coliform Rule.The Eclipse  #88 is a non‐draining unit that comes standard with an all brass waterway and a lockable cast‐aluminum enclosure. Unit is manual‐draining, non‐freezing with use of an attachable manual hand pump (sold separately). An extreme cold climate protection package and low‐lead brass are also available. The Eclipse #88 is fully serviceable from above ground – no digging!above ground  no digging!

ng S

tatio

ns

Standard Features•3’ Bury or Less•¾” FIP Inlet •Unthreaded Nozzle•Lockable Cast‐Aluminum Enclosure•All Brass Working Parts and Waterway•Freeze‐Proof (with use of a hand pump)

Sam

pli •Freeze‐Proof  (with use of a hand pump)

•100% Serviceable from Above Ground

Additional Options and Accessories•Any Depths of Bury over 3’•Threaded Nozzle•PSI Gauge with Custom Threaded Nozzle•Brass Exterior Piping

Optional Plastic Cover

Optional Casted Door Logo

•Pedestal •¼” Ball Valve Versus ¼” Standard Pet‐Cock•Extreme Cold Climate Package•Casted Door Logo•Plastic Enclosure•Hand Pump •Larger Pump for Extreme Cold Climate

Optional Pedestal

Evacuation Hand Pump

PLEASE CONSIDER EXTREME COLD CLIMATE OPTION FOR DEPTHS OF BURY 5’ AND GREATER  

Approx. shipping weight 42 lbs. for 3ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

Optional Pedestal

321‐800‐231‐3990 / www.hydrants.com

Page 35: Kupferle Foundry Catalog - September 2012

S li St tiSampling Stations

The Eclipse #88‐SS Surgical Stainless Steel Sampling

Eclipse #88‐SS Sampling Station (bacteriological)Permanent Sampling Station for All Climates

The Eclipse #88 SS Surgical Stainless Steel Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the water main. The #88‐SS provides a 24/7 designated sampling site to retrieve samples at any time versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times and reduce liability concerns Samplingcollection times, and reduce liability concerns. Sampling Stations have been approved for use by the EPA’s Total Coliform Rule.The Eclipse  #88‐SS is a non‐draining unit that comes standard with an all surgical stainless steel waterway and a lockable cast‐aluminum enclosure. Unit is non‐freezing with use of manual evacuation hand pump (sold separately) Extreme cold climate package available for

Sam

pling S

separately). Extreme cold climate package available for depths of bury of 5’ or more. The Eclipse #88‐SS is fully serviceable from above ground – no digging! 

Standard Features•3’ Bury or Less•½” FIP Inlet  tations

•Unthreaded Nozzle•Lockable Cast‐Aluminum Enclosure•All Stainless Steel Working Parts and Waterway•Freeze‐Proof  (with the use of a hand pump)•100% Serviceable from Above Ground

Additional Options and Accessories•Any Depths of Bury over 3’

Optional Plastic Cover

Optional Casted Door Logo

#88‐SS

Any Depths of Bury over 3•Pedestal •Extreme Cold Climate Package•Casted Door Logo•Plastic Enclosure•Evacuation Hand Pump •Larger Pump for Extreme Cold Climate

Evacuation Hand Pump

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

33

PLEASE CONSIDER EXTREME COLD CLIMATE OPTION FOR DEPTHS OF BURY 5’ AND GREATER  

Approx. shipping weight 42 lbs. for 3ft. Bury

1‐800‐231‐3990 / www.hydrants.com

Optional Pedestal

Page 36: Kupferle Foundry Catalog - September 2012

S li St tiSampling Stations

The Eclipse #88WC Sampling Station is designed

Eclipse #88WC Sampling Station (bacteriological)Permanent Sampling Station for Warm Climates

Standard Low‐Lead Brass!

The Eclipse #88WC Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the water main. The #88WC provides a 24/7 designated sampling site to retrieve samples at any time, versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times, and reduce liability concerns Sampling stations areand reduce liability concerns. Sampling stations are approved for use in the EPA’s Total Coliform Rule.The Eclipse  #88WC is a non‐draining warm climate unit that comes standard with an all brass waterway and a lockable cast‐aluminum enclosure. The option of a durable plastic enclosure is also available. The Eclipse  #88WC is fully serviceable from above ground – no di i !

ng S

tatio

ns

digging!

Standard Features•1’ Bury •All Brass Parts and Waterway

Sam

pli All Brass Parts and Waterway

•Lockable Cast‐Aluminum Enclosure•1” MIP Inlet• Non‐Draining

Additional Options and Accessories•Any Depths of Bury over 1’•Pedestal 

Optional Plastic Cover

Optional Casted Door Logo

•PSI Gauge•Casted Door Logo•Plastic Enclosure•Stainless, PVC Construction•Customized Units Available

Approx. shipping weight 40lbs. for 1ft. BuryOptional Pedestal

Optional  PSI Gauge

Approx. shipping weight 40lbs. for 1ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

1‐800‐231‐3990 / www.hydrants.com34

Page 37: Kupferle Foundry Catalog - September 2012

S li St tiSampling Stations

The Eclipse #88WC‐SS Sampling Station is designed

Eclipse #88WC‐SS Sampling Station (bacteriological)Permanent Sampling Station for Warm Climates

The Eclipse #88WC SS Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the water main. The #88WC‐SS provides a 24/7 designated sampling site to retrieve samples at any time, versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times, and reduce liability concerns Sampling Stations haveand reduce liability concerns. Sampling Stations have been approved for us by the EPA’s Total Coliform Rule.The Eclipse  #88WC‐SS is a warm climate unit that comes standard with an all surgical stainless steel waterway and a lockable cast‐aluminum enclosure. The Eclipse  #88WC‐SS is fully serviceable from above ground – no digging!

Sam

pling SStandard Features•1’ Bury tations

Optional Plastic Cover

Optional Casted Door Logo

•1  Bury •All Surgical Stainless Steel Parts and Waterway•Lockable Cast‐Aluminum Enclosure•½” MIP Inlet and Flow• Non‐Draining

Additional Options and Accessories•Any Depths of Bury over 1’

Optional Pedestal

#88WC‐SS

•Pedestal •Casted Door Logo•Plastic Enclosure

Approx. shipping weight 40lbs. for 1ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

351‐800‐231‐3990 / www.hydrants.com

Page 38: Kupferle Foundry Catalog - September 2012

S li St tiSampling Stations

TheMainGuard #66 Surgical Stainless Steel Sampling

MainGuard #66 Sampling Station (bacteriological)Permanent Sampling Station for All Climates

The MainGuard #66 Surgical Stainless Steel Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the water main. The MainGuard #66 provides a 24/7 designated sampling site to retrieve samples at any time versus sampling from homes and businesses. Sampling stations have been shown to lower false positives speed collection times and reduce liabilitypositives, speed collection times, and reduce liability concerns. Sampling stations have been approved for use by the EPA’s Total Coliform Rule.The MainGuard #66 is a non‐draining unit that comes standard with an all surgical stainless steel waterway and a lockable aluminum enclosure. Unit is non‐freezing with use of manual evacuation hand pump. Extreme cold climate package available for depths of bury of 5’ orclimate package available for depths of bury of 5  or more. The Eclipse #88 is fully serviceable from above ground – no digging! 

Standard Features•3’ Bury or Less•½” FIP Inlet /

ng S

tatio

ns

Flange BottomOptionWith

•7/16” Unthreaded Nozzle•Lockable Aluminum Enclosure•All Stainless Steel Working Parts and Waterway•Freeze‐Proof  (with the use of a hand pump)•100% Serviceable from Above Ground

Additional Options and Accessories•Any Depths of Bury over 3’

Sam

pli Powder‐

CoatedPaint

Optional Plastic Cover

Any Depths of Bury over 3•Customize Enclosure Height / Flange•Extreme Cold Climate Package•Plastic Enclosure•Powder‐Coated Enclosure•Evacuation Hand Pump •Larger Pump for Extreme Cold Climate #66Evacuation 

Hand PumpL k bl Al i

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

PLEASE CONSIDER EXTREME COLD CLIMATE OPTION FOR DEPTHS OF BURY 5’ AND GREATER  

Approx. shipping weight 42 lbs. for 3ft. Bury

1‐800‐231‐3990 / www.hydrants.com36

Lockable AluminumEnclosure

Page 39: Kupferle Foundry Catalog - September 2012

S li St tiSampling Stations

The MainGuard #66 Sampling Station is designed

MainGuard #66WC Sampling Station (bacteriological)Permanent Sampling Station for Warm Climates

The MainGuard #66 Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the water main. The MainGuard #66WC provides a 24/7 designated sampling site to retrieve samples at any time, versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times and reduce liability concerns Sampling Stationstimes, and reduce liability concerns. Sampling Stations have been approved for use by the EPA’s Total Coliform Rule.The MainGuard #66WC is a warm climate unit that comes standard with an all surgical stainless steel waterway and a lockable aluminum enclosure. The MainGuard #66 is fully serviceable from above ground –

di i !

Sam

pling S

no digging!

Standard Features•1’ Bury tations

•1  Bury •All Surgical Stainless Steel Parts and Waterway•Lockable Aluminum Enclosure•½” MIP Inlet and Flow•Non‐Draining

Additional Options and Accessories•Any Depths of Bury over 1’

Optional Plastic Cover Lockable AluminumEnclosure

Flange Bottom

•Customized Enclosure Height / Flange•Plastic Enclosure

Approx. shipping weight 40lbs. for 1ft. Bury #66WC

BottomOptionWith

Powder‐CoatedPaint

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

371‐800‐231‐3990 / www.hydrants.com

Page 40: Kupferle Foundry Catalog - September 2012

S li St tiSampling Stations

The Eclipse #82 Sampling Station is designed specifically for

Eclipse #82 Sampling Station (bacteriological)Permanent Sampling Station for All Climates

The Eclipse #82 Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the water main. The #82 provides a 24/7 designated sampling site to retrieve samples at any time, versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times, and reduce liability concerns. Sampling Stations have been approved for use by the EPA’s Total pp yColiform Rule.The Eclipse  #82 is an all climate unit that comes standard with an all stainless steel waterway, temperature control  valve (non‐freezing unit ) and a lockable UV resistant enclosure (1” model also available). The option of a powder‐coated steel enclosure is also available. The Eclipse  #82 is fully serviceable from above ground – no digging!

ng S

tatio

ns

Standard Features•1’ Bury •All Stainless Steel Parts and Waterway

Sam

pli All Stainless Steel Parts and Waterway

•Lockable UV‐Resistant Enclosure•2” Inlet, 2” Ball Valve Blow‐Off•3/8” Sampling Point w/ ¼” Ball Valve• Freeze‐Proof Temperature Control Valve 

Additional Options and Accessories•Any Depths of Bury over 1’

Optional Powder‐CoatedLockable Steel Enclosure

•Powder‐Coated Steel Enclosure

Approx. shipping weight 75lbs. for 1ft. Bury

Hex‐Lock for Security

Temperature Control Valve and Sampling 

PointApprox. shipping weight 75lbs. for 1ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

1‐800‐231‐3990 / www.hydrants.com38

Page 41: Kupferle Foundry Catalog - September 2012

S li St tiMainGuard #94WM Sampling StationInstalls and resets into Existing Customer Meter Box

Sampling Stations

The MainGuard #94WM Sampling Station is designedThe MainGuard #94WM Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the main water line. The #94WM provides a 24/7 designated sampling site to retrieve samples at any time versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times, and lower liability concerns. Sampling Stations have been approved y p g ppfor use by the EPA’s Total Coliform Rule.

The MainGuard  #94WM is a non‐draining unit that comes standard with an all brass waterway and fits into a standard 5/8” x ¾” existing meter setter. The unique threaded valve connects easily to the sampling rod and eliminates stress on the meter setter as with other quick‐disconnect models. The sampling rod (sold separately) includes a multi‐directional swivel blow‐off head and separate sampling bibb. The option of 1” and 2” sizes and low‐lead brass are available.

Standard Features•Installs in Existing Meter Setting (5/8” x 3/4”)•Male Valve – No Contamination

Sam

pling S

•Custom Threaded Valve (no quick disconnect)

Additional Options and Accessories•All Brass Sampling Rod (variable lengths)•Carrying Case•Brass Valve Cover•5/8” and 1” Resetter Model•Low‐Lead Brass

tations

Low Lead Brass

Approx. shipping weight 42 lbs.

No Meter Box?Same sampling nozzle can be housed in either a galvanized

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

1‐800‐231‐3990 / www.hydrants.com

housed in either a galvanized enclosure or 5¼” valve box

MainGuard #92 / MainGuard #92VB

39

Page 42: Kupferle Foundry Catalog - September 2012

W t Q lit St tiEclipse #9900 Water Quality StationPermanent All‐In‐One Station for All Climates

Water Quality Stations

The Eclipse model #9900 allows a water company to install a reliable blow‐off today, that can be converted into an automatic flushing device in the future.  The initial unit comes standard with a 4” blow‐off  (2” option available) and sampling point for bacteriological samples, but is equipped for easy installation of a 1” automatic flushing component.  A continuous flushing component is also an option.tio

ns

Manual Flushing (2”or 4”)p p

Each station comes with a lockable, UV resistant enclosure.  The Eclipse #9900 is fully serviceable from above ground – no digging!

ter Q

ualit

y S

tat

Sampling Station

Wat

Standard Features•3’ Bury or Less•4” MJ Inlet•4” FIP Outlet• Self Draining, Non‐Freezing•Auto Flushing “Ready”

Automatic Flushing

Auto Flushing  Ready•Bac‐T Sampling Point•Manual Drain On/Off•Locking UV‐Resistant Enclosure

Additional Options and Accessories•Any  Depths of Bury over 3’•6” MJ Inlet

Continuous Flushing

Lockable Enclosure

•1” Automatic Option•Sampling Rod and Case•Continuous Flushing Rod•2” or 4” Riser•Optional Outlet Sizes•Dechlorination Tablet Basket                                                                                        

4” Model = Approx. shipping weight 200 lbs. for 3ft. Bury

See Page 2

4  Model   Approx. shipping weight 200 lbs. for 3ft. Bury2” Model = Approx. shipping weight 120 lbs. for 3ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

401‐800‐231‐3990 / www.hydrants.com

Page 43: Kupferle Foundry Catalog - September 2012

W t Q lit St tiWater Quality Stations

The Eclipse model #9900WC‐2 allows a water company

Eclipse #9900WC Water Quality StationPermanent All‐In‐One Station for Warm Climates

Wate

The Eclipse model #9900WC 2 allows a water company to install a reliable blow‐off today, that can be converted into an automatic flushing device in the future.  The initial unit comes standard with a 2” blow‐off and sampling point for bacteriological samples, but is equipped for easy installation of a 1” automatic flushing component.  A continuous flushing component is also an option

er Quality S

tatio

option.

Each station comes with a lockable, UV resistant enclosure.  The Eclipse #9900WC‐2 is fully serviceable from above ground – no digging!

ons

Standard Features•1’ Bury

Lockable EnclosureSee Page 2

•2” FIP Inlet•2” MIP Outlet•Non‐Draining•Auto Flushing Ready•Bac‐T Sampling Point•Locking Enclosure with Key

Additional Options and AccessoriesAdditional Options and Accessories•Any  Depths of Bury over 1’•1” Automatic Option•Sampling Rod and Case•Continuous Flushing Rod•2” Riser•Dechlorination Option                                                                                        

2” Model = Approx. shipping weight 120 lbs. for 1ft. Bury

Spec sheets, installation details and additional resources are available at 

www.hydrants.com/products

411‐800‐231‐3990 / www.hydrants.com

Page 44: Kupferle Foundry Catalog - September 2012

Y d H d tTotal Eclipse #1 Yard HydrantPermanent Yard Hydrant for All Climates

Yard Hydrants

The Total Eclipse model #1 yard hydrant provides the best in performance and value! Designed and engineered specifically for use in parks, campgrounds, golf courses and homes for non‐drinking use. The Total Eclipse #1 has a unique decorative heavy cast iron top stock and four‐pronged turn handle. Tamper proof key operated option available.

The Total Eclipse model #1 comes standard with all brass working parts, the option of ¾” GHT or 1” MIP hose connection and ¾” or 1” MIP Inlet, self draining non‐freezing drain and key lock option. The Total Eclipse #1 is fully serviceable from above ground – no digging!

Standard Features•3’ Bury or Less•¾” or 1” MIP Inlet

Yard

Hyd

rant

s ¾  or 1  MIP Inlet•All Brass Working Parts•Self‐Draining, Non‐Freezing

Additional Options and Accessories•Any Depths of Bury over 3’•¾” Vacuum Breaker for Nozzle•1” Check Valve for Nozzle

/Y •1” x 3/4" Brass Reducing Adapter•Key Operated•Galvanized Interior Operating Rod•Galvanized Exterior Casing Pipe

Approx. shipping weight for ¾” 29 lbs.Approx. shipping weight for  1” 37 lbs. 

Specification sheets and additional resources are available at 

www.hydrants.com/products

421‐800‐231‐3990 / www.hydrants.com

Page 45: Kupferle Foundry Catalog - September 2012

Y d H d tYard Hydrants

The Total Eclipse model #7 yard hydrant provides the

Total Eclipse #7 Yard HydrantPermanent Yard Hydrant for All Climates

The Total Eclipse model #7 yard hydrant provides the best in performance and value! Designed and engineered specifically for use in parks, campgrounds, golf courses and homes for non‐drinking use. The Total Eclipse #7 has a unique decorative heavy cast iron top stock and spring‐loaded self‐closing lift handle. Tamper proof locking option available. Best used on lines with 90 psi or less (is pressure is greater than 90 psi see our90 psi or less (is pressure is greater than 90 psi , see our Total Eclipse #1 on facing page).

The Total Eclipse model #7 comes standard with all brass working parts, the option of ¾” GHT or 1” MIP hose connection and ¾” or 1” MIP Inlet, self draining non‐freezing drain and locking option. The Total Eclipse g g p p#7 is fully serviceable from above ground – no digging!

Standard Features•3’ Bury or Less•¾” or 1” MIP Inlet Yard H

ydrants

•Spring‐Loaded, Self‐Closing Handle•All Brass Working Parts•Self‐Draining, Non‐Freezing

Additional Options and Accessories•Depths of Bury Over 3’•3/4" Vacuum Breaker for Nozzle•1” x 3/4" Brass Reducing Adapter s1  x  3/4  Brass Reducing Adapter•Lockable Feature

Approx. shipping weight for ¾” 30 lbs. +2 lbs. for every 6”Approx. shipping weight for 1” 38 lbs. +2 lbs. for every 6”

Specification sheets and additional resources are available at 

www.hydrants.com/products43

1‐800‐231‐3990 / www.hydrants.com

Page 46: Kupferle Foundry Catalog - September 2012

Y d H d tTotal Eclipse #36 Street WasherPermanent Box Hydrant for All Climates

Yard Hydrants

The Total Eclipse model #36 Street Washer is designed and engineered for wash down and filling needs. The Total Eclipse #36 provides a point to retrieve water to wash down sidewalks and streets or used to water gardens and lawn areas. The Total Eclipse #36 sits flush with the ground saving space in walking areas. The cast iron box and lid is not traffic rated.

The Total Eclipse #36 comes standard with all brass working parts, available nozzle and Inlet sizes are ¾” or 1”, compression type self draining non‐freezing drain, cast iron box and lid. The Total Eclipse model #36 is fully serviceable from above ground – no digging!

Standard Features•3’ Bury or Less•Cast iron Box

Yard

Hyd

rant

s Cast iron Box•¾” or 1” MIP Inlet•All Brass Working Parts•Key Operated

Additional Options and Accessories•Any Depths of Bury over 3’•Locking Lid

Y •Brass Box & Lid•Deep Box•¾” Vacuum Breaker with Deep Box•1” Check Valve with Deep Box•Galvanized Pipe•#159 Key (spare)

Approx. shipping weight for ¾” 20 lbs. + 2 lbs for every 6”

Specification sheets and additional resources are available at 

www.hydrants.com/products

Approx. shipping weight for ¾  20 lbs. + 2 lbs for every 6Approx. shipping weight for 1” 22 lbs + 3 lbs. for every 6”

441‐800‐231‐3990 / www.hydrants.com

Page 47: Kupferle Foundry Catalog - September 2012

Y d H d tYard Hydrants

Kupferle’s Yard Hydrant Companion is a pre‐installation

Total Eclipse #3400 Yard Hydrant CompanionPermanent Yard Hydrant Companion for All Climates

Kupferle s Yard Hydrant Companion is a pre installation sleeve for any  ¾” yard hydrant. Install the Yard Hydrant Companion first, and then slide any ¾” yard hydrant down the sleeve and screw it onto the Yard Hydrant Companion’s internal ¾” nipple.  Clamps at the ground line hold the hydrant in place. Then, when your hydrant needs to be replaced it can be done WITHOUT DIGGING! Just undo the clamps unscrew the entireDIGGING! Just undo the clamps, unscrew the entire hydrant  and then repair and replace or install a new hydrant into the sleeve. Available in any depth of bury.

Standard Features

Additional Options and Accessories•Depths of Bury over 3’

Yard Hydrantss

Approx. shipping weight 25 lbs. +2 lbs. for every 6” See our compatible Yard Hydrants on page

44-45

Specification sheets and additional resources are available at 

www.hydrants.com/products

451‐800‐231‐3990 / www.hydrants.com

Page 48: Kupferle Foundry Catalog - September 2012

Y d H d tCorn King #903 Yard HydrantPermanent Yard Hydrant for All Climates

Yard Hydrants

The Corn King model #903 Yard hydrant is designed as a “dry and wet” pipe principal of construction. The outer or dry pipe encloses and protects the inside parts while the inner or wet pipe protects water as it passes to the brass outlet nozzle.

The Corn King model #903 comes standard with galvanized inside and outside pipe with all brassgalvanized inside and outside pipe with all brass working parts, ¾” FIP Inlet and ¾” GHT outlet, self draining non‐freezing drain. The Corn King model #903 is fully serviceable from above ground – no digging!

Standard Features•3’ Bury or Less•Compression Type

Yard

Hyd

rant

s Compression Type•True ‘dry pipe’ design•¾” FIP Inlet•¾” Hose Outlet•Galvanized Pipe

Additional Options and Accessories•Any Depths of Bury over 3’

Y •¾” Vacuum Breaker for Nozzle• Lockable Enclosure

Approx.  shipping weight 25 lbs + 5 lbs. for every 6”

#903 shown with optional cast‐aluminum lockable enclosure, 

great for ball fields, garden areas, etc.

Specification sheets and additional resources are available at 

www.hydrants.com/products

461‐800‐231‐3990 / www.hydrants.com

Page 49: Kupferle Foundry Catalog - September 2012

Y d H d tYard Hydrants

The Corn King model #909 Yard hydrant is designed as a

Corn King #909 Yard HydrantPermanent Yard Hydrant for All Climates

The Corn King model #909 Yard hydrant is designed as a “dry and wet” pipe principal of construction. The outer or dry pipe encloses and protects the inside parts while the inner or wet pipe protects water as it passes to the brass outlet nozzle. Best used on lines with 90 psi or less (is pressure is greater than 90 psi , see our Corn King #903 on facing page).

The Corn King model #909 comes standard with galvanized inside and outside pipe with all brass working parts, ¾” FIP Inlet and ¾” GHT Outlet, self draining non‐freezing drain. The Corn King model #909 is fully serviceable from above ground – no digging!

Standard Features•3’ Bury or Less•Spring–Loaded, Self‐Closing Type Yard H

ydrants

•True ‘dry pipe’ design•¾” FIP Inlet•¾” Hose Outlet•Galvanized Pipe

Additional Options and Accessories•Any Depths of Bury Over 3’•¾” Vacuum Breaker for Nozzle s¾  Vacuum Breaker for Nozzle•Lockable Features

Approx. shipping weight 25 lbs. + 5 lbs for every 6”

Specification sheets and additional resources are available at 

www.hydrants.com/products

471‐800‐231‐3990 / www.hydrants.com

Page 50: Kupferle Foundry Catalog - September 2012

N lt ItHydrant LampAuthentic Brass‐Plated Hydrant Lamp

Novelty Items

The Kupferle Foundry Company, maker of hydrants for over 150 years, now offers its 19th century decorative Eclipse #2 post hydrant as a lamp! Made of solid cast‐iron and then brass‐plated to provide it with a beautiful finish, this unique lamp will become one of your most prized possessions!

Dimensions: 30” H x 7¾” W

NEW

Dimensions: 30  H x 7¾ W

Weight: 36 lbs.

Only $349.99Order direct by calling 800‐231‐3990 or faxing an order 

form to 314‐231‐2820Order forms can be found at 

h d t /h d tl

Puppy Dog HydrantAuthentic Cast‐Iron Hydrant

NEW

www.hydrants.com/hydrantlamp

The Kupferle Foundry Company, maker of authentichydrants for over 150 years, now offers its 19th

century decorative Eclipse #2 post hydrant to dogowners! This original cast‐iron hydrant comes with a

personalized name plate and chain. Optional urn that fits inside also available, making it a lasting memorial to your 

faithful friend and companion.

NEW

Dimensions: 23” H x 7¾” W

Weight: 36 lbs.

Only $199.99

Order direct by calling 800‐231‐3990 or faxing an order form 

t 314 231 2820to 314‐231‐2820Order forms can be found at 

www.hydrants.com/puppydoghydrant

481‐800‐231‐3990 / www.hydrants.com

Page 51: Kupferle Foundry Catalog - September 2012

O d i I f i /A f Q liOrdering Information/Assurance of Quality

Placing Orders by Fax:314‐231‐2820

The Kupferle Foundry Company proudly sells its

products through waterworks

For Product Inquiries/Quotes800‐231‐3990

F P t /C t S i

products through waterworks distributors across the United States and Canada. To obtain pricing on Kupferle products,

please contact your local waterworks distributor(s) or call 1 800 231 3990 for a listing ofFor Parts/Customer Service

800‐231‐3990

Spec Sheets, Installation Details, Cut Sheets, Product Info:h d t / d t

1-800-231-3990 for a listing of distributors in your area.

www.hydrants.com/products

Kupferle is proud to state that its products are made in America! We guarantee our product’s parts and labor for up to one full year (automatic flushing units up to three years) under normal installation and operational use. Additionally, Kupferle strives to deliver not only the best in quality products, but also customer service. If you have an issue with any Kupferle product, please contact us at 1‐800‐231‐3990.  

In response to the ARRA Compliance of Manufactured Goods as American Made, The Kupferle Foundry Company provides answers to three (3) questions furnished by the USEPA that determines The Kupferle Foundry Companymeets the ARRA compliance. To obtain a copy of our compliance document please go to our website at www hydrants comdocument, please go to our website at www.hydrants.com

Kupferle offers low‐lead brass versions of the following products:•Eclipse Automatic Flushing devices (all models)•Eclipse #88•Eclipse #88WC, standard•MainGuard #77, #78•MainGuard #94WM•Truflo TF200, TF250•Truflo TF500, TF550, TF800•Total Eclipse #1, #7, #36•Corn King #903, #909

Low Lead

1‐800‐231‐3990 / www.hydrants.com

Page 52: Kupferle Foundry Catalog - September 2012

1‐800‐231‐3990 toll free  •  www.hydrants.com  •  [email protected] •  314‐231‐2820 fax     

2511 North 9th Street, St. Louis, MO 63102