Kamin-Kessel 45 101 GB

5
 BRUNNER WATER BOILERS Kamin-Kessel 45/101 lifting doors  made in germany State: 25.02.2013

Transcript of Kamin-Kessel 45 101 GB

  • BRUNNER WATER BOILERS

    Kamin-Kessel 45/101lifting doors

    made in germany

    State: 25.02.2013

  • Kamin-Kessel 45/101 lifting doorsDimension sheet |

    with mounting frame 50 mm

    VL supply 1"RL return boiler 1"E drain 1/2"SVL supply cooling pipe outletSRL return cooling pipe outletFTAS socket for thermometer cooling TF1 socket 1/2" for thermometerTF2 socket 1/2" for thermometer

    with mounting frame 70 mm

    VL supply 1"RL return boiler 1"E drain 1/2"SVL supply cooling pipe outletSRL return cooling pipe outletFTAS socket for thermometer cooling TF1 socket 1/2" for thermometerTF2 socket 1/2" for thermometer

    We suggest for CAD planing Palette CAD. Permanent updated drawings: www.brunner.deFrames / front versions are marked colored.Art.-Nr I019490 flue gas adapter for horizontal outlet (E= 250mm / A= 200mm)

  • Kamin-Kessel 45/101 lifting doorsDimension sheet |

    with door frame

    VL supply 1"RL return boiler 1"E drain 1/2"SVL supply cooling pipe outletSRL return cooling pipe outletFTAS socket for thermometer cooling TF1 socket 1/2" for thermometerTF2 socket 1/2" for thermometer

    We suggest for CAD planing Palette CAD. Permanent updated drawings: www.brunner.deFrames / front versions are marked colored.Art.-Nr I019490 flue gas adapter for horizontal outlet (E= 250mm / A= 200mm)

  • Planning and installationKamin-Kessel 45/101

    meets requirement limit values forGermany / Austria / Switzerland / Norway 1.BlmSchV (Stufe 2) / 15. BVG / LRV / -

    Rated heat power

    Combustion performanceFlue gas mass flow

    adjoining cast iron radiator (GNF10)accumulation rings (MAS)adjoining ceramic accumulatorceramic modular accumulator (KMS system)water boiler

    Necessary supply pressure

    Firewood consumption

    Combustion air consumptionCombustion air connection

    Distance to oven chamber wallDistance to floor

    WallFloorCeilingBrick lining of protected walls

    Data for functional demonstration

    Flue gas temperature after

    Heat distribution

    Cross-section of gratings for max. warm air power

    Space inside oven chamber

    Heat insulation without / with

    Insert / heating surface

    Boiler

    attached steel smoke hood

    Outlet temperature (before heating surface)

    Supply airWarm air

    kWkg/hkWg/sC

    CCCCCCPam/hmm

    %

    %

    cmcm

    cmcm

    cmcmcmcm

    Tested according to

    Glass (single / double)

    1)

    2)

    %

    max. operating pressuremax. flow temperatureWater volumeConnections flow / return

    Water boiler databarClitresinch

    EN 13229 W

    WeightFireplace + burning chamber 182 + 154 + 89kg

    3) air gratings

    EN 13229 W

    4)

    -

    24,521,5

    ----

    2001555125

    62

    20

    1010

    3100551

    -

    15 / -

    45 - 50

    400400

    6

    40 / 35

    19

    2315

    ----

    1701245

    125

    62

    201010

    -

    15 / -

    45 - 50

    400400

    5,2

    40 / 35

    3100551

    Ulrich Brunner GmbHZellhuber Ring 17 -18D-84307 EggenfeldenPhone: +49 / (0)87 21 / 7 71-0Fax: +49 / (0)87 21 / 7 [email protected] | www.brunner.de

    BRUNNER products are offered and sold only by qualified dealers and service centres.Subject to technical and assortment changes. Errors excepted.

    Approximate value, must be calculated eventually1)2)

    Throttle flap recommended

    Values with air gratings, stove casing is heat conducting3)heater = body + mounted exchanger4)

    (02/13)