Investment Engineering and Principal Contractor Ltd .

21
Vocational publication System of thermography with the sponsorship of project ‘Application of modern building diagnostic methods at South-Transdanubian region using professional thermal imager and dew point measuring’ Investment Engineering and Principal Contractor Ltd. H-7400 Kaposvar, 1st Kontrassy Street A projekt a Nemzeti Kutatási és Technológiai Hivatal támogatásával valósult meg.

description

Vocational publication System of thermography with the sponsorship of project ‘ Application of modern building diagnostic methods at South-Transdanubian region using professional thermal imager and dew point measuring ’. A projekt a Nemzeti Kutatási és Technológiai - PowerPoint PPT Presentation

Transcript of Investment Engineering and Principal Contractor Ltd .

Page 1: Investment  Engineering  and  Principal Contractor  Ltd .

Vocational publication 

System of thermography with the sponsorship of project ‘Application of modern building

diagnostic methods at South-Transdanubian region using professional thermal imager and

dew point measuring’

Investment Engineering and Principal Contractor Ltd. H-7400 Kaposvar, 1st Kontrassy Street

A projekt a Nemzeti Kutatási és Technológiai

Hivatal támogatásával valósult meg.

Page 2: Investment  Engineering  and  Principal Contractor  Ltd .

Beneficiary: Investment Engineering and Principal Contractor Ltd. H-7400 Kaposvar, 1st Kontrassy Street

 Construction activity: Technical research and innovation, engineering activity, counsel, organization of construction projects Procurement cost of project: net 8,035,450.00 HUF Sponsor Authority: National Research and Science Office of Technology (’Nemzeti Kutatasi és Technologiai Hivatal’) – in the name of the responsible minister for developing of research and innovation of technology Sponsor resource: Innovational foundation for research and science

(’Kutatasi és Technologiai Innovacios Alap’)Provided assistance: net 5,614,00.00 HUF

Page 3: Investment  Engineering  and  Principal Contractor  Ltd .

Contents of publication 1.Insight of pursuit of our company2.Determining milestones of procurement project3.Achievements of the project4.Possibilities of economics and societal exploitation to the long term

Page 4: Investment  Engineering  and  Principal Contractor  Ltd .

1.Insight of pursuit of our company Forming : The Ltd is formed by two private persons in September 1992. Main activity: Technical research and innovation, engineering activity, counsel, organization of construction projects. Previous activities coherent with the project::• own investment of an A+ energetics category condominium building• using of WinWatt and DanWattPlus softvers• producing expert’s appraisal of building energetics• producing applications of nationwide block of flats - program, expert advice• expert’s appraisal of justice

Our colleagues participant the project:• Certified civil engineer 2 persons• Certified economist 1 person• Mechanical engineer 1 person• Engineer of systems analyst 2 persons• Architect 1 person

Page 5: Investment  Engineering  and  Principal Contractor  Ltd .

2.Determinig milestones of procurement project  

Equipment and service procured with the sponsorship :• VarioCAM inspect 680 type 640 x 480 pixel thermal imager 30 mK sensitivity with accessories• IRBIS 3 evaluating softver, theoretical and practical training for 2 persons• Testo 410-2 airspeed, air humidity, and temperature measurer• HP 6830s Notebook for the evaluate in site

PR activity• informing the previous clientele for the possibilities of the procured equipment• finding new costumers (also private persons) with advertising activity• connecting and interview with the partners of interdisciplinary use

Page 6: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

The system of thermography has been operated to support the new and pending expert’s appraisals :• evaluation of old buildings• searching for heat-technics errors of renovated buildings • making outside and inside photos to search of thermal insulation errors• checking the thermal insulation and air-locking of windows and doors• producing repairing conception with the methods of evaluation used lately

 

Page 7: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

• exploration of heat bridges, prevention of the moisture condensation.

Our goal is a healthy home!• cost optimization of building renovations with refinement of the conventional heat-technics calculation• searching errors of windows, doors, and roller-blinds, giving suggestion about repairing• constitution of renovating policy with systematizing the long term results of measuring and valuations

 

Page 8: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

1. photo: B30 brick wall, reinforced concrete bearers and rings are heat bridges.

Page 9: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

2. photo: the heat bridge effect of reinforced concrete bearer and balcony plate is visible.

Page 10: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

3. photo: attic covered with plasterboard. The error of thermal insulation causes temperature under dewpoint. Moisture condensation causes mouldiness on the both sides of plasterboard. The solution is to fill in the place behind the cover with foam.

Page 11: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

4. photo: heat bridge is caused by breast-wall-ring.

Page 12: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

5. photo: thermal insulated building, errors of insulation can be seen under the plaste. In top of the picture the the grossness of insulation was reduced under the gas pipeline.

Page 13: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

6. photo: the previous thermal insulated house, the thin heat insulation along the pipeline caused heat bridge.

Page 14: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

7. photo: thermal image of balcony door. because of the bad air-lock, the air chills the floor and the frame of the door.

Page 15: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

8. photo: thermal image of front door, was made from inside. bad air-lock can be observed at the doorstep.

Page 16: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

9. photo: good thermal insulated building, fitting and air-locking of window should be repaired.

Page 17: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

10. photo: excellent thermal insulated building, no heat bridges.

Page 18: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.1. Achievements of own application

11. photo: the previous thermal insulated building, thermal insulation of foundation can also be observed. Warm air of the air-outlet can be seen on the upper part of the photo.

Page 19: Investment  Engineering  and  Principal Contractor  Ltd .

3.Achievements of the project

3.2. Achievements of interdisciplinary applications

Partners of the project, and their functions :

• University of Pecs, Mihaly Pollack Faculty of Engineering (’Pecsi Tudomanyegyetem Pollack Mihaly Muszaki Kar’) Department of Building Engineering (’Epuletgepeszeti

Tanszek’) Supporting science research and diploma thesis

works at mechatronics research3. University of Kaposvar, Faculty of Zoografic

(’Kaposvari Egyetem Allatudományi Kar’) Supporting science research in the examination

of animals and animal therapy

The beginning of the science programs has proceeded recently, the achievements of application can be prognosticated to the next year.

 

Page 20: Investment  Engineering  and  Principal Contractor  Ltd .

4.Possibilities of economics and societal exploitation to the long term

We plan to exploit our thermography system, and to establish bilaterally prosperous collaborations with industrial undertakings, medical and educational institutes. Realistically possible applications of the procured technical equipment :• thermografy of buildings• finding of errors of electricity, errors in building engineering• checking large systems of electricity (power-lines and installations)• support of undertakings using a unique and valuable machine• planned, preventive service• monitoring a procedure• support of spa and orthopaedics• using a painless and alternative method of medical diagnostics• supporting science research programs• audit of any kind of process of natural science which causes 0.03 °C temperature changing or difference.

 

Page 21: Investment  Engineering  and  Principal Contractor  Ltd .

Thank you for your kind attention!

Investment Engineering and Principal Contractor Ltd.H-7400 Kaposvar, 1st Kontrassy Street

+36 82 529 250www.investment.hu