Industrial Noise Control & Acoustic Consultation United Can
![Page 3: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/3.jpg)
Measurement: Semua Mesin On
![Page 4: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/4.jpg)
Measurement: Mesin Off
![Page 5: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/5.jpg)
Simmulation: Panel
![Page 6: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/6.jpg)
Transmission Loss: Panel
![Page 7: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/7.jpg)
Kesimpulan Simulasi Panel
• STC pada panel chamber memiliki nilai = 30• Di bawah frekuensi 125 Hz mampu memberi redaman sebesar 25 dB• Pada frekuensi 125 Hz – 2000 Hz mampu memberi redaman sebesar
15 dB – 45 dB• Pada frekuensi di atas 2000 Hz mampu memberi redaman lebih besar
dari 35 dB
![Page 8: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/8.jpg)
Simmulation: Kolom
![Page 9: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/9.jpg)
Transmission Loss: Kolom
![Page 10: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/10.jpg)
Kesimpulan Simulasi Kolom
• STC pada panel chamber memiliki nilai = 39• Di bawah frekuensi 31,5 Hz mampu memberi redaman sebesar 40 dB• Pada frekuensi 31,5 Hz – 1000 Hz mampu memberi redaman sebesar
15 dB – 55 dB• Pada frekuensi di atas 1000 Hz mampu memberi redaman lebih besar
dari 50 dB
![Page 11: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/11.jpg)
Kesimpulan Lanjutan
• Karena adanya lubang padachamber sebagai sirkulasiudara untuk mesin genset, maka akan terjadiperubahan transmission loss.
• Besar bukaan sebesar:• Bidang insulasi = 108 m2• Lubang = 0,95 m2• (0,95/108) = 0,88%
• Perkiraan transmission loss digambarkan pada garismerah pada tabel di samping
![Page 12: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/12.jpg)
Saran
• Apabila lubang pada chamber tidak dapat diminimalisir maka padasela-sela antara pipa / conveyor / exhuast dengan dinding chamber dapat disisipklan Acourete Fiber secara rapat untuk meningkatkankualitas redaman.
![Page 13: Industrial Noise Control Consultation](https://reader033.fdocument.pub/reader033/viewer/2022042604/588a98d91a28ab904b8b6549/html5/thumbnails/13.jpg)