  • TPA Calibration Services | 1

    Calibration Services of Industrial

    Measuring Instruments

    1. Calibration of electric measuring instruments2. Calibration of temperature measuring instruments3. Calibration of light measuring instruments4. Calibration of mass & weight measuring instruments5. Calibration of pressure & vacuum measuring instruments6. Calibration of force & torque measuring instruments7. Calibration of size & dimensional measuring instruments

    Calibration Services of Medical

    and Laboratory Measuring

    Instruments

    1. Calibration of volumetric measuring instruments2. Calibration of chemical measuring instruments3. Calibration of relative humidity measuring instruments4. Test / calibration of medical measuring instruments

    On-Site Calibration Services

    1. Calibration of weighing apparatus2. Calibration of pressure meters3. Calibration of temperature measuring instruments4. Calibration of surface plates5. Calibration of work piece inspectors: Profile Projector6. Calibration of laboratory instruments: pH Meter, Spectro-photometer, Centrifuge7. Test / calibration of medical measuring instruments: Defibrillator, Infusion Pump, Syringe Pump, ECG Monitor, Infant Radiant Warmer, NIBP Monitor

    Other Additional Services

    1. Acceptance & delivery service within (Metropolitan) Bangkok, Ayutthaya, Chachoengsao, Chonburi and Rayong2. Provision of calibration service for the whole factory by arranging all-year queue to accept/deliver3. Instrument acceptance & delivery service to the customers through transporting to companies nationwide4. Provision of credit / accumulation of total use of services to get the discount fee of calibration service5. To offer services to check the status of instruments via website6. Calibration package service for the whole factory7. Pre-assessment service for the laboratory in conformity with ISO/IEC 170258. Expertise in comparison service among laboratories (Proficiency Test)9. Consulting service on calibration works and ISO/IEC 17025 quality system

    Calibration Equipment and Testing ServicesOur laboratory, with quality system in conformity with ISO/IEC 17025 accredited

    from Thai Industrial Standards Institute (TISI), Ministry of Industry, offers calibration services of industrial, medical and various fields of laboratory measuring instruments. Our services cover every field of the industry, including instruments of secondary standard and working standard levels. Additional services are also available, e.g. acceptance & delivery of instruments, calibration package service for the whole factory, on-site calibration services, etc. We presently offer calibration services of industrial, medical and various fields of laboratory measuring instruments as follows:

    Corporate Services 3

    Technology Promotion Association (Thailand-Japan), or TPA, was officially established on 24 January 1973 through determination, commitment and cooperation of Japan Alumni and former trainees funded by ABK and AOTS. Mr. Sommai Huntrakul, the former Minister of Finance, was the Chairman of the Establishment Committee and Professor Goichi Hozumi, the former Chairman of the Japan-Thailand Economic Cooperation Society, assisted establishment. The main objectives of TPA are to be a center to promote dissemination of new knowledge and technology to Thai personnel to make advancement in the Thai economy and industry.

    TPA has grown and evolved constantly and has accumulated expertise in providing various services: organizing curriculum for seminars, trainings, self-learning, consultancy in technology, environmental quality, safety, and management, diagnosis of enterprises (Shindan), Equipments Calibration and Testing Services and School of Language and Culture, including expertise in publishing textbooks for learning foreign languages, books on cultural issues and personal development, as well as academic textbooks on technology and quality. TPA now has three business offices, i.e. Head Office at Sukhumvit Soi 29, Technology Promotion Institute at Pattanakarn Soi 18, and School of Language and Culture Zeer Rangsit Branch, and offers different services and activities as follows:

    บริการสอบเทียบ

    และทดสอบเคร�องมือวัด(เคร�องมือวัดอุตสาหกรรม / เคร�องมือวัดทางการแพทย และหองปฏิบัติการ)

    สมาคมสงเสริมเทคโนโลยี (ไทย-ญี่ปุน)

    Technology Promotion Association (Thailand-Japan)

    NSC-TISI-TIS17025CALIBRATION 0008

    TPA EQUIPMENTCALIBRATION AND

    TESTINGSERVICES

    http://www.tpa.or.th/ce/

    บริการสอบเทียบ

    และทดสอบเคร�องมือวัด

    TPA Calibration and Testing Equipment Services

    http://www.tpa.or.th/ce/

    สมาคมสงเสริมเทคโนโลยี (ไทย-ญี่ปุน)

    Technology Promotion Association (Thailand-Japan)

    Calibration and Testing Equipment Services

    (เคร�องมือวัดอุตสาหกรรม / เคร�องมือวัดทางการแพทย และหองปฏิบัติการ)

    NSC-TISI-TIS17025CALIBRATION 0008

  • 2 | TPA Calibration Services

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Pressure Gauge**

    up to 70 kg/cm2 (Pneumatic) up to 1000 bar (Hydraulic)

    Pressure Gauge (Accuracy > 0.6%) 6 Pressure Gauge (Accuracy 0.1% to 0.6%) 11 Pressure Gauge (Accuracy < 0.1%) 11

    2 Standard Pressure Gauge**

    Standard Pressure Gauge (Accuracy > 0.6%) 6 Standard Pressure Gauge (Accuracy 0.1% to 0.6%) 11 Standard Pressure Gauge (Accuracy < 0.1%) 11

    3 Pressure Indicator**

    Pressure Indicator (Accuracy > 0.6%) 6 Pressure Indicator (Accuracy 0.1% to 0.6%) 11 Pressure Indicator (Accuracy < 0.1%) 11

    4 Pressure Calibrator**

    Pressure Calibrator (Accuracy > 0.6%) 6 Pressure Calibrator (Accuracy 0.1% to 0.6%) 11 Pressure Calibrator (Accuracy < 0.1%) 11

    5 Pressure Recorder**

    Pressure Recorder (Accuracy > 0.6%) 6 Pressure Recorder (Accuracy 0.1% to 0.6%) 11 Pressure Recorder (Accuracy < 0.1%) 11

    6 Pressure Transmitter**

    Pressure Transmitter (Accuracy > 0.6%) 6 Pressure Transmitter (Accuracy 0.1% to 0.6%) 11 Pressure Transmitter (Accuracy < 0.1%) 11

    TPA Calibration ServicesTechnology Promotion Association (Thailand-Japan)

    Pressure & Vacuum

    บริการสอบเทียบ

    และทดสอบเคร�องมือวัด(เคร�องมือวัดอุตสาหกรรม / เคร�องมือวัดทางการแพทย และหองปฏิบัติการ)

    สมาคมสงเสริมเทคโนโลยี (ไทย-ญี่ปุน)

    Technology Promotion Association (Thailand-Japan)

    NSC-TISI-TIS17025CALIBRATION 0008

    TPA EQUIPMENTCALIBRATION AND

    TESTINGSERVICES

    http://www.tpa.or.th/ce/

  • TPA Calibration Services | 3

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    7 Pressure Transducer**

    Pressure Transducer (Accuracy > 0.6%)

    up to 70 kg/cm2 (Pneumatic) up to 1000 bar (Hydraulic)

    6 Pressure Transducer (Accuracy 0.1% to 0.6%) 11 Pressure Transducer (Accuracy < 0.1%) 11

    8 Pressure Controller**

    Pressure Controller (Accuracy > 0.6%) 6 Pressure Controller (Accuracy 0.1% to 0.6%) 11 Pressure Controller (Accuracy < 0.1%) 11

    9 Vacuum Gauge**

    Vacuum Gauge (Accuracy > 0.6%)

    up to 700 mmHg

    6 Vacuum Gauge (Accuracy 0.1% to 0.6%) 11 Vacuum Gauge (Accuracy < 0.1%) 11

    10 Vacuum Calibrator**

    Vacuum Calibrator (Accuracy > 0.6%) 6 Vacuum Calibrator (Accuracy 0.1% to 0.6%) 11 Vacuum Calibrator (Accuracy < 0.1%) 11

    11 Standard Vacuum Gauge**

    Standard Vacuum Gauge (Accuracy > 0.6%) 6 Standard Vacuum Gauge (Accuracy 0.1% to 0.6%) 11 Standard Vacuum Gauge (Accuracy < 0.1%) 11

    12 Barometer (Accuracy > 0.6%) 800 mbara to 1150 mbara 5 13 Dead Weight Tester up to 35 kg/cm2 (Pneumatic)

    up to 1,000 bar (Hydraulic)-

    Pressure & Vacuum (Cont.)

  • 4 | TPA Calibration Services

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Digital Multimeter

    DC Voltmeter 0 V to 1,000 V 3 AC Voltmeter 0 V to 1,000 V 2 DC Ammeter 0 A to 11 A 2 AC Ammter 0 A to 11 A 2 Ohm Meter 0 - 300 MΩ 2 Capacitance Meter 330 pF to 1,100 µF 2 Frequency 0 to 1.3 GHz 2 #

    All Range up to 20 Range - 2 Analog Multimeter

    DC Voltmeter 0 V to 1,000 V 5 AC Voltmeter 0 V to 1,000 V 5 DC Ammeter 0 A to 11 A 5 AC Ammeter 0 A to 11 A 5 Ohm Meter 0 - 300 MΩ 5 Capacitance Meter 330 pF to 1,100 µF 5 All Range up to 20 Range -

    3 Digital Multimeter (< 5 1/2 Digit)Calibrate all Function more than 20 Range

    - -

    4 Gauss Meter, Tesla Meter 0.1G to 21G, 100G,500G, 1,000G

    - #

    5 Oscilloscope (0.2 mV to 10 Vp-p, 2ns to 5s) 0.05 to 250 MHz - 6 Frequency Generator (< 1 x 10-5 Period) 0 to 300 MHz 6 7 Timer (0 to 90 Minute) Second, Minute, Hour 6 8 Digital Tachometer / Stroboscope rpm, m/min 6 9 Frequency Counter 10 MHz 1

    10 Quartz Stop Watch 1 Point Only 1 11 Fixed Resistor up to 2 GΩ 1

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Torque Wrench / Torque Screw Driver 0.33 lbf.ft. to 50 lbf.ft. 5 point fix for Accreditation 20%, 60%, 100% of fulll scale >50 lbf.ft. to 1,000 lbf.ft. 5

    2 Torque Wrench / Torque Screw Driver (1 Point Only) 0.33 lbf.ft. to 50 lbf.ft. - >50 lbf.ft. to 1,000 lbf.ft. -

    3 Torque Calibrator 0.44 lbf.ft. to 1,000 lbf.ft. -

    Torque Instrument

    Electrical Instrument

  • TPA Calibration Services | 5

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    12 AC / DC Calibrator

    DC Voltage Source 0 V to 1,000 V 5 AC Voltage Source 0.1 V to 1,000 V 5 DC Current Source 0.1 mA to 20 A 5 AC Current Source 0.1 mA to 20 A 5 Resistance Source 0 Ω to 2 GΩ 5 Frequency Source 0 to 300 MHz 5 DC Voltage Measurement 0 V to 1,000 V 5 AC Voltage Measurement 0.1 V to 1,000 V 5 DC Current Measurement 0.1 mA to 11 A 5 AC Current Measurement 10 mA to 11 A 5 Resistance Measurement 0 Ω to 330 GΩ 5 Frequency Measurement 0 to 1.3 GHz 5

    13 Temperature Recorder, Temperature Indicator

    (Input, Output : mV, Ohm) Every Range, Type & Standard 6 14 Temperature Calibrator

    (Input, Output : mV, Ohm) Every Range, Type & Standard 6 15 Temperature Transmitter (Machanic Type) Every Range, Type & Standard 6 #

    16 Temperature Transmitter (Electronic Type) Every Range, Type & Standard 5 #

    17 AC/DC Highvoltage (Source, Measurement) 0 kV to 6.5 kV (AC) 5 0 kV to 10 kV (DC) 5

    18 Power Meter, AC / DC Wattmeter (Single Phase)

    Digital 11 kW 2 Analog 11 kW 6

    19 Insulation Meter 1 MΩ to 2 GΩ (100V, 500V, 1,000V)

    6

    20 Reference Thermometer (Resistance Measurement) 0.1, 1, 10, 25, 100, 200, 400,1,000 Ω, 10 KΩ -

    21 Photometry (Illuminance/Lux Meter) 15 lx to 5,000 lx - 22 Multi-Product Calibrator Function : DCV, ACV, DCA, ACA,

    Ohm Capacitance, Phase, TC, Frequency

    -

    Electrical Instrument (Cont.)

  • 6 | TPA Calibration Services

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Outside Micrometer (Step by 25 mm) 0 mm to 525 mm 11 0 mm to 25 mm 11

    > 25 mm to 150 mm 11 > 150 mm to 350 mm 11 > 350 mm to 525 mm 11

    2 Inside Micrometer 5 mm to 30 mm 11 25 mm to 150 mm 11

    3 Micrometer Standard / Standard Bar 0 mm to 300 mm 11 4 Micrometer Head 0 mm to 50 mm - 5 Tubular Inside Micrometer

    Micrometer Head (Single Type) 50 mm to 63 mm 14 #

    Extension Rod Type

    - Micrometer Head 50 mm to 63 mm 14 #

    50 mm to 75 mm 11 #

    100 mm to 125 mm 11 #

    - Extension Rod 13 mm to 400 mm 1 #

    6 Can Seam Micrometer 0 mm to 13 mm 15 7 Dial Gauge / Dial Thickness Gauge / Dial Caliper Gauge 0 mm to 100 mm - 8 Utrasonic Thickness Gauge / Ladder Step 0 mm to 100 mm - #

    9 Dial Test Indicator (Up 1 Range, Down 1 Range) 0 mm to 1 mm - 10 Depth Gauge (Digital / Analog) 0 mm to 300 mm 15 11 Depth Micrometer 0 mm to 300 mm 11

    0 mm to 150 mm 11 150 mm to 300 mm 11

    12 High Gauge (Digital / Analog) (< 300 mm) 0 mm to 300 mm 150 mm 17 200 mm 19 300 mm 24

    High Gauge (Digital / Analog) (> 300 mm) 0 mm to 600 mm 450 mm 17 600 mm 19

    13 Vernier Caliper (Digital / Analog) 0 mm to 300 mm (inside, outside, depth) 150 mm 13

    200 mm 14 300 mm 16

    Dimension Instrument

  • TPA Calibration Services | 7

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    14 Vernier Caliper (Digital / Analog) (> 300 mm) 0 mm to 1,000 mm (inside, outside) 450 mm 16

    600 mm 17 1,000 mm 21 1,500 mm 26 #

    15 Calibration Tester, Dial Gauge Tester, Micro Meter Head 0 mm to 50 mm - 16 Gauge Block (Grade 0, 1, 2)

    0.5 mm to 100 mm - Central Length and Variation Length17 Long Gauge Block (Grade 1, 2) > 100 mm to 500 mm - 18 Steel Ruler / Mandrel / Digital Scale Unit 0 mm to 2 m

    Millimeter (mm) 10 Centimeter (cm) 10 Inch (inch) 10

    19 Scale Loupe, Zoom Loupe 0 mm to 50 mm #

    Millimeter (mm) 10 #

    Inch (inch) 10 #

    20 Steel Tape / PI Tape 0 mm to 50 m 10 21 Feeler Gauge / Thickness Gauge 0 mm to 3 mm - 22 Film Gauge 0 mm to 3 mm - #

    23 Taper Gauge (Scale Type) 0 mm to 100 mm 15 24 Riser Block 150 mm, 300 mm - 25 Depth Microchecker 0 mm to 150 mm 6

    0 mm to 300 mm 12 26 Linear Scale 0 mm to 1,000 mm 10 27 Level Gauge 0 mm to 50 mm 21 28 Height Master 0 mm to 300 mm - 29 Caliper Checker 0 mm to 300 mm - 30 Electronic Comparator up to 500 um - 31 Snap Gauge Φ 20 mm to 100 mm - 32 Pin Gauge Φ up to 100 mm - 33 Plug Gauge Φ up to 200 mm - 34 Thread Plug Gauge Φ M1 to M68 - 35 Ring Gauge Φ 0.5 mm to 200 mm - 36 Thread Ring Gauge Φ 3 mm to M68 - 37 Thread Measuring Wires (3 ea/set) All Range - 38 Bore Guage All Range -

    - Extension Rod

    Dimension Instrument (Cont.)

  • 8 | TPA Calibration Services

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Weights (Class F1)

    Measurement & Adjustment 1 mg to 20 kg> 20 kg to 50 kg

    2 Weights (Class F2, M1, M2, M3)

    Measurement & Adjustment 1 mg to 20 kg> 20 kg to 50 kg

    3 The Weight are except OIML R111-1

    Measurement & Adjustment 1 mg to 20 kg> 20 to 50 Kg

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Beam Balance 1 mg to 60 kg - 2 Electronic Balance 1 mg to 50 kg 10

    > 50 kg to 300 kg 10 3 Dial Tension Gauge 1 mg to 2 kg 5 4 Force Gauge, Push - Pull Gauge / Suspension Spring Balance 1 mg to 60 kg 10 5 Spring Balance 1 mg to 50 kg 10

    > 50 kg to 300 kg 10 6 Durometer (Scale Shore A, Shore D) 10 to 90 9 #

    Balance

    Mass

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Thermometer ** -40 ºC to 1,100 ºC

    Digital Thermometer with Sensor -40 ºC to 1,100 ºC, -38 ºC to 900 ºC Liquid in Glass Thermometer (Total Immersion) -40 ºC to 400 ºC, -38 ºC to 400 ºC #

    Liquid in Glass Thermometer (Partial Immersion) -40 ºC to 400 ºC, -38 ºC to 400 ºC

    Dial Thermometer, Temperature Gauge -40 ºC to 1,100 ºC, -38 ºC to 400 ºC

    Data Logger with Sensor -40 ºC to 1,100 ºC, -38 ºC to 400 ºC

    MIG Thermometer, Thermometer for Retort -40 ºC to 400 ºC, -38 ºC to 200 ºC

    2 Standard Thermometer **(Accuracy

  • TPA Calibration Services | 9

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Non-Invasive Blood Pressure Simulator / NIBP Analyzer Static Pressure, Heart Rate 2 ECG / Patient Simulator ECG, Lead Resistance,

    Waveform#

    3 Fetal Simulator Fetal & Maternal Heart Rate #

    4 Multiparameter Simulator ECG, BP Static, Temp Output, Baseline Respiration

    #

    5 Parameter Tester Pressure & Vacuum #

    6 Vital Signs Simulator ECG, BP Static, Temp Output, Beseline, Manometer, SpO2

    #

    7 SpO2 Analyzer / Pulse Oximeter Simulator DC Voltage Check@ Test Point, Finger Probe Check : 85 to 98%

    #

    8 Infusion Pump Analyzer / Tester 5, 50, 100, 300 ml/h & Pressure Measurement

    #

    9 Ultrasound Watt / Power Meter Power Measurement #

    Medical Equipment

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    3 Thermocouple Probe **, wire ** -40 ºC to 900 ºC

    Thermocouple Type E, T, K, J, N -38 ºC to 400 ºC Thermocouple Type K, R, S > 400 ºC to 900 ºC Thermocouple Type K -40 ºC to

  • 10 | TPA Calibration Services

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    10 Defibriilator Analyzer Operation Verification,Heart Rate, Biphasic

    Energy Point 5, 50, 100,150, 200 Joules

    #

    Model: Impulse 6000D / 7000DP #

    Model: QA-40M/45 #

    Model: Other #

    11 Spring / Digital Blood Collection Scale / Mixer Blood Volumetric, Mixer #

    12 Electrical Safety Analyzer / Tester Enclosure / Patient /Earth Leakage, Ground WireResistance, Mains Voltage,

    Insulation, ECG

    #

    13 Gas Flow Meter 1LPM to 70 LPM #

    14 Analog Gas Flow Meter / Rota Meter 1LPM to 70 LPM #

    15 Gas Flow Analyzer / Ventillator Tester 1LPM to 50 LPM, Air way / Low/High Pressure,

    Oxygen Measurement

    #

    16 Oxygen Analyzer 20.9% & 100% #

    17 Electrosurgery Analyzer / Electrosurgical Analyzer VAR.Load: 10 to 1,600Ω, Power : 50 to 300 Watt @300Ω

    #

    18 Phototherapy / Bili-Meter / IR Radiance Radiometer 5 to 40 uW/ cm2/ nm #

    19 Gas Indicator (RIKEN KEIK) Test Pump Flow confirming Sensitivities #

    20 Plasma Thawing & Warming Cal. Mode, Plasma, Warmer, Thawer

    #

    21 Infusion Pump, Syringe Pump 5 ml/h to 300 ml/h, Alarm Test #

    22 Clinical Thermometer 35 ºC, 37 ºC, 41 ºC #

    23 Defibrillator / Pacer 5 J to 360 J, Sync Time, ECG, Pacer

    #

    24 ECG Recorder ECG, Paper Speed, Sensitivity #

    25 Mechanical Sphygmomanometer 0 mmHg to 300 mmHg 26 Digital Blood Pressure Monitor 0 mmHg to 300 mmHg 27 Infant Warmers 30 ºC, 35 ºC, 37 ºC #

    28 IR Ear Thermometer 35 ºC, 37 ºC, 41 ºC #

    29 Pacemaker, AED Defibrillator Pacer, ECG, Energy #

    30 Medical Suction Unit / Pump Pressure, Vacuum #

    31 Phototherapy Unit / Lamp Spectral Irradiance Test #

    32 Vital Sings / Patient / Bedside Monitor ECG, NIBP, SpO2 #

    33 Pulse Oxymeter SpO2, Pulse Rate #

    34 Oxygen Flow / Regulator Flow, Pressure #

    35 Ventilator Volume, PIF, I:E Ratio, PIP, PEEP, Oxyyen

    #

    36 Respirator PIF, PIP, PEEP, Oxyyen #

    Medical Equipment (Cont.)

  • TPA Calibration Services | 11

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument

    Standard

    Point for

    Calibration

    ISO/IEC

    17025

    1 pH Meter

    Accredit ISO/IEC 17025

    1.1 pH Meter (Part mV) 1.2 pH Meter (Electrode)

    Set 1 Set 2

    1 point : pH 4.0 or pH 7.0 or pH 9.0 pH 4.0 or pH 7.00 or pH 10.0 2 points : pH (4.0, 7.0) or pH (7.0, 9.0) pH (4.0, 7.0) or pH (7.0, 10.0) 3 points : pH (4.0, 7.0, 9.0) pH (4.0, 7.0, 10.0) 4 points : pH (4.0, 7.0) and (7.0, 9.0) pH (4.0, 7.0) and pH (7.0, 10.0) Not Accredit ISO/IEC 17025 #

    cal. 1 point : pH 4 or pH 7 or pH 10

    cal. 2 points : pH (4, 7) or pH (7, 10)

    cal. 3 points : pH (4, 7, 10)

    cal. 4 points : pH (4, 7) and pH (7, 10)

    2 Conductivity Meter

    (25, 147, 1,409, 12,880, 111,300,) µS/cm (84, 100, 1,413, 12,880) µS/cm #

    Chemical Equipment

    Item Type of Instrument RangeISO/IEC

    17025

    1 Thermohygrometer (Electronic Type) 11.3 % R .H. to 85% R.H.@ 25 ºC (Temperature & Humidity) 10 ºC to 40 ºC Calibration & Adjustment 85% R.H. to 95% R.H. @ 25 ºC #

    (-40) ºC to 9 ºC & 41 ºC to 70 ºC #

    2 Thermohygrometer (Mechanic Type) 11.3% R .H. to 85% R.H.@ 25 ºC (Temperature & Humidity) 10 ºC to 40 ºC Calibration & Adjustment 85% R.H. to 95% R.H. @ 25 ºC #

    (-40) ºC to 9 ºC & 41 ºC to 70 ºC #

    3 Thermohygrograph 11.3% R .H. to 85% R.H.@ 25 ºC (Temperature &Humidity) 10 ºC to 40 ºC Calibration & Adjustment 85% R.H. to 95% R.H. @ 25 ºC #

    (-40) ºC to 9 ºC & 41 ºC to 70 ºC #

    Relative Humidity Instrument

  • 12 | TPA Calibration Services

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Chemical Equipment (Cont.)

    Item Type of Instrument

    Standard

    Point for

    Calibration

    ISO/IEC

    17025

    3 Spectrophotometer 8 Photometric Accuracy (3 point)

    (UV at 235, 257, 313, 350 nm.)

    (Visible at 440, 465, 546, 590, 635 nm.)

    Wavelength Accuracy 241-880 nm. (5 point)

    4 Turbidity Meter (20, 40, 100, 400 NTU) #

    5 Brix Refractometer Accredit ISO/IEC 17025 (10,20,30,50,60, % Brix)

    Refractive index : (1.34782,1.36384,1.38115,1.42009,1.44193 nD)

    Not Accredit ISO/IEC 17025 (5, 73%Brix)

    Refractive Index : (1.34026, 1.4731 nD) #

    6 Salinity Refractometer (2.50% w/w NaCI, 2.84% w/w NaCI) #

    7 Centrifuge

    Revolution per Minutes (rpm) 1,000 to13,000 rpm Revolution per Minutes (rpm) 13,000 to 30,000 rpm #

    Time (0 minute to 10 minute) 8 DO Meter 8 mg/L #

    9 TDS Meter #

    Point : 50, 100, 250, 300, 500, 1000, 2000, 25000 ppm

    10 Breath alcohol 2 Evidential breath alcohol

    0.22 mg/l

    0.35 mg/l

  • TPA Calibration Services | 13

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    1 Graduated and Volumetric Glassware Volumetric Pipette (0.5,1-10, 15, 20, 25, 30, 50, 100 ml)

    Measuring Pipette (0.1 mL to 50 mL) Volumetric Flask (1, 2, 5, 10, 20, 25, 50, 60, 100 ml)

    (150, 200, 250, 500, 1,000, 2,000 mL) Graduated Cylinder (1 mL to 2,000mL) Buret (1 mL to 50 mL)

    2 Piston Pipette (Micropipette, Autopipette) 2 µL to 1,0000 µL or 0.001 ml to 10 ml Calibration & Adjustment

    3 Dispenser (0.5 mL to 100 mL) Calibration & Adjustment

    4 Piston Burette (Digital Burette) up to 50 mL Calibration & Adjustment

    5 Auto Burette up to 100 mL 6 Graduated and Volumetric Plasticware

    Volumetric Pipette (up to 100 mL) #

    Measuring Pipette (up to 100 mL) #

    Volumetric Flask (up to 100 mL) #

    Volumetric Flask (> 100 mL to 2,000 mL) #

    Graduated Cylinder (up to 100 mL) #

    Graduated Cylinder (> 100 mL to 1,000 mL) #

    Graduated Cylinder (> 1,000 mL to 2,000 mL) #

    7 Saybolt Viscosity Flask (1 mL to 100 mL) #

    8 Erlenmeyer Flask (up to 2,000 mL) #

    9 Beaker (up to 2,000 mL) #

    10 Centrifuge Tube #

    Charge price for 25% if change the new piece.

    Volumetric

  • 14 | TPA Calibration Services

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC

    17025

    1 Pressure Gauge (Class > 0.6%) (Use Clean Air) 0 kPa to 200 kPa

    > 200 kPa to 2,000 kPa

    (Use Oil) > 200 kPa to 2,000 kPa

    > 2,000 kPa to 16,000 kPa

    2 Vacuum Gauge (Class > 0.6%) -0.9 kPa to 0 kPa

    1 Digital Thermometer with Sensor / Dial Thermometer / Temperature Controller

    -25 ºC to 400 ºC

    2 Temperature Recorder with Sensor(Electronic, Machanic Type)

    -25 ºC to 400 ºC

    3 Temperature Source

    Testing Water Bath (5 Senser) ambient +5 ºC to 100 ºC Testing Oil Bath (5 Senser) -38 ºC to 200 ºC #

    Calibration Bath (9 Senser) -38 ºC to 200 ºC #

    Liquid Bath (9 Senser) -38 ºC to 200 ºC #

    Micro Bath (9 Senser) -38 ºC to 200 ºC #

    4 Temperature Controller Chamber Oven, Incubator, Refrigerator, Freezer (9 Sensor) -35 ºC to 0 ºC

    > 0 ºC to 200 ºC Oven, Incubator, Refrigerator, Freezer (10 - 40 Sensor) -35 ºC to 200 ºC Oven, Incubator, Refrigerator, Freezer (> 40 Sensor) -35 ºC to 200 ºC Autoclave (3 Sensor) 100 ºC to 135 ºC Autoclave (10 Sensor) 100 ºC to 135 ºC #

    Refrigerator & Freezer -35 ºC to 200 ºC 5 Furnace > 200 ºC to 950 ºC #

    6 COD Reactor / Dry Bath -30 ºC to 200 ºC #

    1 Spring Balance 1 mg to 50 kg > 50 kg to 300 kg

    2 Electronic Balance 1 mg to 50 kg > 50 kg to 300 kg

    Pressure & Vacuum

    Balance

    Temperature

    On-Site Calibration Services

  • TPA Calibration Services | 15

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    1 Infusion Pump, Syring Pump 5 ml/h to 300 ml/h, Alarm test #

    2 Clinical Thermometer 35 ºC, 37 ºC, 41 ºC

    3 Defibrillator 5 J to 360 J, Sync Time, ECG, Pacer

    #

    4 ECG Recorder ECG, Print Speed, Sensitivity #

    5 Mechanical Sphygmomanometer 0 mmHg to 250 mmHg 6 Digital Blood Pressure Monitor 0 mmHg to 250 mmHg 7 Infant Warmers 35 ºC, 37 ºC #

    8 IR Ear Thermometer 35 ºC, 37 ºC, 41 ºC #

    9 Pacemaker, AEC Defibrillator Pacer, ECG, Energy #

    10 Medical Suction Unit Pressure, Vacuum #

    11 Spring / Digital Blood Collection Scale / Mixer Blood Volumetric, Mixer #

    12 Plasma Thawing & Warming Cal. Mode, Plasma, Warmer, Thawer #

    13 Phototherapy Unit / Lamp Spectral Irradiance Test #

    14 Vital Sings / Patient / Bedside Monitor ECG, NIBP, SpO2 #

    15 Pulse Oxymeter SpO2,Pulse Rate #

    16 Oxigen Flow / Regulator Flow, Pressure #

    17 Ventilator Volume, PIF, I:E Ratio PIP, PEEP, Oxyyen #

    18 Respirator PIF, PIP, PEEP, Oxyyen #

    Item Type of Instrument Range

    Standard

    Point for

    Calibration

    ISO/IEC 17025

    7 Unitrex 100 ºC to 400 ºC #

    8 Temperature & Humidity Chamber 20% R.H. to 85% R.H. @Ref.Temp.20 ºC to 25 ºC

    20% R.H. to 65% R.H. @Ref.Temp.25 ºC to 30 ºC

    Only Temperature Function : -30 ºC to 200 ºC

    Temperature (Cont.)

    Medical Equipment

  • 16 | TPA Calibration Services

    ISO/IEC 17025 Laboratory Accredited# Not ISO/IEC 17025 Accredited

    CONTACT :

    Technology Promotion Association (Thailand-Japan)

    534/4 Soi Pattanakarn 18, Pattanakarn Rd., Suanluang Bangkok 10250 ThailandPhone 66 2 717 3000 ext. 82 Fax : 66 2 719 9484, 66 2 717 3609

    MON - FRI at 08.00 am to 05.00 pmWeb Site : www.tpa.or.th/ce E-mail : [email protected]

    Item Type of InstrumentStandard Point

    for CalibrationISO/IEC 17025

    1 pH Meter

    Accredit ISO/IEC 17025

    1.1 pH Meter (Part mV) 1.2 pH Meter (Electrode)

    Set 1 Set 2

    1 point : pH 4.01 or pH 6.86 or pH 9.18 pH 4.01 or pH 7.00 or pH 10.01 2 points : pH (4.01, 6.86) or pH (6.86, 9.18) pH (4.01, 7.0) or pH (7.0, 10.01) 3 points : pH (4.01, 6.86, 9.18) pH (4.01, 7.0, 10.01) 4 points : pH (4.01, 6.86) and (6.86, 9.18) pH (4.01, 7.0) and pH (7.0, 10.01) Not Accredit ISO/IEC 17025

    cal. 1 point : pH 4 or pH 7 or pH 10 #

    cal. 2 points : pH (4, 7) or pH (7, 10) #

    cal. 3 points : pH (4, 7, 10) #

    cal. 4 points : pH (4, 7) and pH (7, 10) #

    2 Conductivity Meter

    (147, 1,400, 12,900, 111,300) µS/cm (84, 100, 1,413, 12,880) µS/cm #

    3 Spectrophotometer

    Photometric Accuracy (3 Point)

    8 (UV at 235, 257, 313, 350 nm.)

    (Visible at 440, 465, 546, 590, 635 nm.)

    Wavelength Accuracy 241-880 nm. (5 Point)

    4 Centrifuge

    Revolution per Minutes (rpm) 1,000 to 13,000 rpm Revolution per Minutes (rpm) < 1,000 rpm >13,000 to 30,000 rpm #

    Time (0 minute to 10 minute) #

    5 Breath alcohol 2 Evidential breath alcohol

    0.22 mg/l, 0.35 mg/l

    Chemical Equipment

  • วันจันทร์

    สายที่ 1: *กรุงเทพฯ ยอดใช้บริการไม่ถึง 3,000 บาท (ค่าบริการรับส่ง 300 บาท)

    สายที่ 2: พระราม 2 - สมุทรสาคร - ถนนบางขุนเทียนชายทะเล - เอกชัย

    สายที่ 3: ท้ายบ้าน - ปากน�้า - นิคมฯ บางปู - แพรกษา - กิ่งแก้ว - นิคมฯ ลาดกระบัง - มีนบุรี - เสรีไทย - ประเวศ *สุวินทวงศ์ (ค่าบริการรับส่ง 300 บาท)

    สายที่ 4: บางบอน - เพชรเกษม - บางแค - กระทุ่มแบน - อ้อมน้อย - อ้อมใหญ่ - สามพราน (ค่าบริการรับส่ง 300 บาท)

    วันอังคาร

    สายที่ 1: สุขุมวิท 62 - เทพารักษ์ - อ่อนนุช - ลาซาล - นิคมฯ บางพลี - บางบ่อ - บางโฉลง - บางนา

    สายที่ 2: นิคมฯ เวลโกว์ - บางปะกง - นิคมฯ ทองโกรว์ - อมตะนคร - แสนภูดาษ - นิคมทีเอฟด ี(ค่าบริการรับส่ง 300 บาท)

    สายที่ 3: *เมืองชลบุรี - บายพาส - พัทยา - บางแสน - ศรีราชา - แหลมฉบัง - ปิ่นทอง - บ้านบึง - เครือสหพัฒน์ฯ (ค่าบริการรับส่ง 300 บาท)

    สายที่ 4: *อมตะซิตี้ - อีสเทิร์นซีบอร์ด - สยามอีสเทิร์น - บ่อวิน (ค่าบริการรับส่ง 300 บาท) **นิคมพัฒนา - มาบตาพุด (ค่าบริการ 500 บาท) ***เมืองระยอง (ค่าบริการรับส่ง 700 บาท)

    วันพุธ

    สายที่ 1: *กรุงเทพฯ ยอดใช้บริการไม่ถึง 3,000 บาท (ค่าบริการรับส่ง 300 บาท)

    สายที่ 2: รังสิต - ล�าลูกกา - คลอง 1 ถึง คลอง 5 - ธัญบุรี - สายไหม - รามอินทรา

    สายที่ 3: นวนคร - บางปะอิน - ไฮเทค - โรจนะ

    สายที่ 4: บางซื่อ - วงศ์สว่าง - แจ้งวัฒนะ - ปากเกร็ด - กระทรวงสาธารณสุข - บางกรวย - บางกระดี *ลาดหลุมแก้ว (ค่าบริการ 300 บาท)

    วันพฤหัสบดี

    สายที่ 1: ท้ายบ้าน - ปากน�้า - นิคมฯ บางปู - แพรกษา - กิ่งแก้ว - นิคมฯ ลาดกระบัง - มีนบุรี - เสรีไทย - ประเวศ*สุวินทวงศ์ (ค่าบริการรับส่ง 300 บาท)

    สายที่ 2: พระราม 2 - สมุทรสาคร - ถนนบางขุนเทียนชายทะเล - บางบอน - เอกชัย

    สายที่ 3: ปู่เจ้า - พระประแดง - ส�าโรง - สุขสวัสดิ์ - ราษฎร์บูรณะ

    สายที่ 4: บางบอน - เพชรเกษม - บางแค - กระทุ่มแบน - อ้อมน้อย - อ้อมใหญ่ - สามพราน - บางพลัด - พุทธมณฑล (ค่าบริการรับส่ง 300 บาท)

    วันศุกร์

    สายที่ 1: สุขุมวิท 62 - เทพารักษ์ - อ่อนนุช - ลาซาล - นิคมฯ บางพลี - บางบ่อ - บางโฉลง - บางนา

    สายที่ 2: นิคมฯ เวลโกว ์- บางปะกง - นิคมฯ ทองโกรว์ - อมตะนคร - แสนภูดาษ - นิคมทีเอฟด ี(ค่าบริการรับส่ง 300 บาท)

    สายที่ 3: *เมืองชลบุรี - บายพาส - พัทยา - บางแสน - ศรีราชา - แหลมฉบัง - ปิ่นทอง - บ้านบึง - เครือสหพัฒน์ฯ (ค่าบริการรับส่ง 300 บาท)

    สายที่ 4: *อมตะซิตี้ - อีสเทิร์นซีบอร์ด - สยามอีสเทิร์น - บ่อวิน (ค่าบริการ 300 บาท) **นิคมพัฒนา - มาบตาพุด (ค่าบริการ 500 บาท) **เมืองระยอง (ค่าบริการ 700 บาท)

    สมาคมส่งเสริมเทคโนโลยี (ไทย-ญี่ปุ่น)

    เส้นทางบริการรับ-ส่งเครื่องมือ

    บริการสอบเทียบ

    และทดสอบเคร�องมือวัด(เคร�องมือวัดอุตสาหกรรม / เคร�องมือวัดทางการแพทย และหองปฏิบัติการ)

    สมาคมสงเสริมเทคโนโลยี (ไทย-ญี่ปุน)

    Technology Promotion Association (Thailand-Japan)

    NSC-TISI-TIS17025CALIBRATION 0008

    TPA EQUIPMENTCALIBRATION AND

    TESTINGSERVICES

    http://www.tpa.or.th/ce/

    บริการสอบเทียบ

    และทดสอบเคร�องมือวัด(เคร�องมือวัดอุตสาหกรรม / เคร�องมือวัดทางการแพทย และหองปฏิบัติการ)

    สมาคมสงเสริมเทคโนโลยี (ไทย-ญี่ปุน)

    Technology Promotion Association (Thailand-Japan)

    NSC-TISI-TIS17025CALIBRATION 0008

    TPA EQUIPMENTCALIBRATION AND

    TESTINGSERVICES

    http://www.tpa.or.th/ce/

  • 1. ชำ�ระโดยเงินสด2. ชำ�ระโดยเช็คธน�ค�รสั่งจ่ายในนาม “สมาคมส่งเสริมเทคโนโลยี (ไทย-ญี่ปุ่น)” หรือ “Technology Promotion Association (Thailand-Japan)”3. ชำ�ระผ่�นธน�ค�รในนาม “สมาคมส่งเสริมเทคโนโลยี (ไทย-ญี่ปุ่น)” หรือ “Technology Promotion Association (Thailand-Japan)” (บัญชีออมทรัพย์) โอนเงินผ่านธนาคาร - ธนาคารกรุงเทพ สาขาสุขุมวิท 43 เลขที่ 172-0-23923-3 - ธนาคารไทยพาณิชย์ สาขาสุขุมวิท 45 เลขที่ 009-2-23325-3 - ธนาคารกรุงไทย สาขาพัฒนาการ เลขที่ 064-1-11613-6

    กรณีลูกค้าใช้บริการรถรับ-ส่งเครื่องมือของ ส.ส.ท.

    ลูกค้านำาสำาเนาใบแจ้งหนี้มาติดต่อชำาระเงิน

    ได้ที่แผนกการเงิน (ชั้น 2)

    หลังจากทำาการสอบเทียบเสร็จแล้ว จะติดต่อแจ้งลูกค้า

    โดยโทรสาร/อีเมล ใบแจ้งหนี้ และโทรแจ้งทางโทรศัพท์

    ลูกค้าตรวจสอบความถูกต้องของข้อมูล

    และรายละเอียดในใบขอรับบริการพร้อมลงนามและรับเอกสารดังกล่าวไว้เป็นหลักฐานในการรับเครื่องมือต่อไป

    กรอกข้อมูลรายละเอียดลูกค้าในใบขอรับบริการ

    *ข้อมูลลูกค้า (ชื่อ-ที่อยู่ สำาหรับออกใบเสร็จและออกใบรับรอง) เบอร์โทรศัพท์ เบอร์โทรสาร/ชื่อผู้ติดต่อได ้ข้อมูลเครื่องมือ ยี่ห้อ รุ่น หมายเลขเครื่อง

    พิกัดที่ต้องการสอบเทียบ

    ลูกค้าส่งเครื่องมือ

    ที่สำานักงานบริการสอบเทียบฯ (ชั้น 1)

    กรณีลูกค้ารับ-ส่งเครื่องมือเอง

    ขั้นตอนการส่งเครื่องมือ

    นำาใบเสร็จรับเงินมาติดต่อ

    รับเครื่องมือและใบรับรอง (Certificate)

    ได้ที่สำานักงานบริการสอบเทียบฯ (ชั้น 1) รับเครื่องมือคืน พร้อมใบรับรอง (Certificate)

    1

    2

    3

    4

    5

    6

    7

    เมื่อลูกค้าได้รับแฟกซ์ ใบแจ้งหนี้

    หลังจากทำาการสอบเทียบเสร็จแล้ว จะติดต่อแจ้งลูกค้า

    โดยโทรสาร/อีเมล ใบแจ้งหนี้ และโทรแจ้งทางโทรศัพท์

    ลูกค้าตรวจสอบความถูกต้องของข้อมูล

    และรายละเอียดในใบขอรับบริการพร้อมลงนามและรับเอกสารดังกล่าวไว้เป็นหลักฐาน และพนักงานรับเครื่องมือกลับสำานักงานบริการสอบเทียบฯ (ชั้น 1)

    พนักงานกรอกข้อมูลของลูกค้าในใบขอรับบริการ

    รายละเอียดดังนี้

    * ข้อมูลลูกค้า (ชื่อ-ที่อยู่ สำาหรับออกใบเสร็จ และออกใบรับรอง) เบอร์โทรศัพท์ เบอร์โทรสาร / ชื่อผู้ติดต่อได้ ข้อมูลเครื่องมือ ยี่ห้อ รุ่น หมายเลขเครื่อง พิกัดที่ต้องการสอบเทียบ

    พนักงาน ส.ส.ท. นัดวันเข้าไปรับเครื่องมือที่บริษัทของลูกค้า

    โดยจะออกเอกสารใบขอรับบริการล่วงหน้าเพื่อรับเครื่องมือ

    ลูกค้าส่งโทรสาร รายการเครื่องมือ

    ที่ต้องการใช้บริการรับ-ส่ง มาที่เบอร์ 0-2719-9484

    *กรณีลูกค้�ยังไม่ได้รับเครดิตหลังจากได้รับใบแจ้งหนี้แล้ว ลูกค้าดำาเนินการเบิกจ่ายเงินสด เช็ค หรือโอนเงินเข้าบัญชีของ ส.ส.ท. แล้วแฟกซ์ใบนำาฝากเข้ามาที่ ส.ส.ท. พร้อมนัดวันส่งคืนเครื่องมือกับเจ้าหน้าที่ (พนักงานจะนำาเครื่องมือ Certificate ใบแจ้งหนี้ต้นฉบับ / ใบเสร็จรับเงิน / ใบกำากับภาษีไปให้ลูกค้า ในวันส่งเครื่องมือ)

    *กรณีลูกค้�เครดิตพนักงานจะนำาเครื่องมือพร้อม Certificate และใบแจ้งหนี้ต้นฉบับ ไปให้ลูกค้าในวันส่งเครื่องมือ

    นำาส่งเครื่องมือคืนให้กับลูกค้า

    วิธีการชำาระเงิน หมายเหตุ

    ** หากลูกค้ามีความประสงค์ใช้บริการรับ-ส่ง เครื่องมือของสมาคมฯ ทางสมาคมฯ จะไม่รับผิดชอบต่อความเสียหายในระหว่างการขนส่ง แต่จะรับผิดชอบต่อการสูญหายเท่านั้น

    n ลูกค้าต้องเตรียมเครื่องมือให้พร้อมตามวันนัด หากเจ้าหน้าที่ไม่อยู ่จะต้องมีผู้รับมอบแทน

    n เครื่องมือต้องพร้อมส่งทันทีที่เจ้าหน้าที่ของสมาคมฯ ไปรับn สมาคมฯ จะให้บริการรับ-ส่ง เฉพาะลูกค้าที่อยู่ในเส้นทางการเดินรถ

    หรือลูกค้าที่มีข้อตกลงกับสมาคมฯ เท่านั้นn กรณีลูกค้าขอเลื่อนนัดต้องแจ้งให้สมาคมฯ ทราบล่วงหน้าอย่างน้อย 2 วันn กรณีที่ลูกค้าอยู่นอกเส้นทาง แต่มีความประสงค์จะขอใช้บริการรับ-ส่ง

    จะต้องแจ้งล่วงหน้าอย่างน้อย 3 วัน และสมาคมฯ ขอสงวนสิทธิ ์ในการพิจารณาให้บริการรับ-ส่ง ตามความเหมาะสม

    แผนที่ ส.ส.ท. พัฒนาการ 18