Guide to BTS3900 and BTS3900A SDR and RFU Co-
Cabinet Slot Configuration Principles and Internal
Cable Connections V1.0
(For internal use only)
Prepared by Song Zhifa Date 2009-11-24
Reviewed by Date 2009-11-24
Approved by Date
Huawei Technologies Co., Ltd.
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Change History
Date Revision Version Description Author
2009-11-24 V1.0 Initial release. Song Zhifa
2023-4-17 Huawei Confidential Page 2 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Contents
1 Preface.......................................................................................................................................... 5
2 Basic Principles........................................................................................................................... 5
2.1 Basic Configuration Principles for the RFU.........................................................................5
2.2 Basic Configuration Principles for the Antenna System......................................................6
3 Basic Configuration Principles for the CPRI Port.....................................................................6
3.1 Overview............................................................................................................................. 6
3.1.1 Configuration Scope.................................................................................................6
3.1.2 Numbering Descriptions...........................................................................................6
3.1.3 Descriptions on Site Type Name..............................................................................7
3.2 Configuration Principles for the CPRI Port..........................................................................7
4 Slot Configurations and Cable Connections in Scenarios Only with MRFUs........................8
4.1 Single-Cabinet Single-Band Scenarios...............................................................................8
4.1.1 Scenario 1: Single-Band Site with No More Than Three Sectors.............................8
4.1.2 Scenario 2: Single-Band Site with More Than Three Sectors.................................11
4.2 Single-Cabinet Dual-Band Scenarios................................................................................13
4.2.1 Scenario 3: Dual-Band Site with No More Than Three Sectors..............................13
5 Slot Configuration Principles and Cable Connections in Scenarios with Co-Cabinet MRFU,
DRFU, GRFU, and WRFU.............................................................................................................14
5.1 Single-Band Scenario.......................................................................................................15
5.2 Dual-Band Scenarios with Co-Cabinet MRFUs and GRFUs/DRFUs................................15
5.2.1 Scenario 4: Single-Cabinet with No More Than Three Sectors at All Bands..........15
5.2.2 Scenario 5: Single-Cabinet Site with More Than Three Sectors at One Band........17
5.2.3 Scenario 6: Dual-Cabinet Site with Non-Inter-Cabinet GRFUs/DRFUs and No More
Than Three Sectors at All Bands.....................................................................................18
5.2.4 Scenario 7: Dual-Cabinet Site with Non-Inter-Cabinet GRFUs/DRFUs and More
Than Three Sectors at One Band....................................................................................20
5.2.5 Scenario 8: Dual-Cabinet with Inter-Cabinet GRFUs/DRFUs and No More Than
Three Sectors at All Bands..............................................................................................21
5.2.6 Scenario 9: Dual-Cabinet Site with Inter-Cabinet GRFUs/DRFUs and More Than
Three Sectors at One Band.............................................................................................22
5.3 Dual-Band Scenario with Co-Cabinet MRFU and WRFU..................................................24
5.3.1 Scenario 10: Single-Cabinet Site with No More Than Three Sectors at Dual-Band
........................................................................................................................................ 24
5.3.2 Scenario 11: Dual-Cabinet Site with No More Than Three Sectors at Dual-Band. .25
5.3.3 Scenario 12: Dual-Cabinet Site with More Than Three Sectors at One Band........27
2023-4-17 Huawei Confidential Page 3 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
5.4 Three-band MRFU and GRFU/DRFU Sharing the Cabinet with WRFU............................29
5.4.1 New and Swapped Scenarios with Co-Cabinet MRFU, GRFU/DRFU, and WRFU 29
5.4.2 Scenarios Expanded from MRFU+WRFU to MRFU+WRFU+GRFU/DRFU at Other
Bands.............................................................................................................................. 35
6 Appendix...................................................................................................................................... 37
2023-4-17 Huawei Confidential Page 4 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
1 PrefaceThe GSM-UMTS (GU) co-cabinet RFU solutions to the 3900 series BTSs are used in
scenarios with various modules. In this case, the on-site data configuration, assembly,
and in-board transport are difficult to implement. To facilitate the field engineers to
allocate slots and connect RF cables and to improve the product installation
feasibility, this document describes the RFU slot configuration principles and internal
cable connections based on scenarios with co-cabinet MRFU and other modules.
This document describes basic principles for the GSM only, UMTS only, and GU co-
cabinet. Slots and cable connections are regular, which can facilitate subsequent
expansion and maintenance. It serves as a brochure to guide customers in how to
apply such basic principles. The configuration tool is developed based on this
document. It can be obtained from http://support.huawei.com. The calculation
configuration tool can fast display the configuration and cable connection figures to
assist field engineers in the product delivery.
2 Basic PrinciplesThe GRFU, DRFU, WRFU, and MRFU can be combined flexibly to form various co-
cabinet solutions to the 3900 series BTSs. This document is only for dual cabinets or
one cabinet. The cabinet is the indoor middle-sized cabinet or outdoor RFC. The
RFU, antenna system, and CPRI are involved.
The basic principles in this chapter serve as the overview of all principles. You are
advised to read this chapter beforehand to fully understand the principles and
configuration tool in this document.
2.1 Basic Configuration Principles for the RFU
The smooth upgrade and expansion principles are specified. When the
configuration parameters can be set in multiple hardware configuration modes,
you can select the optimal mode to facilitate the subsequent smooth upgrade
and expansion.
This document only describes the slot configuration principles and cable
connections for the BTS3900 and BTS3900A with MRFUs and co-cabinet
MRFU+GRFU/WRFU.
The single-cabinet or dual-cabinet described in this document indicates the
middle-sized cabinet or RFC.
This document is only used with the SRAN3.0 and SRAN5.0. The principles can
be applied to the SRAN3.0 and SRAN5.0 otherwise specified. Features
dedicated to the SRAN3.0 or SRAN5.0 are specified in this document.
2023-4-17 Huawei Confidential Page 5 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
2.2 Basic Configuration Principles for the Antenna System
To ensure proper connections of antenna systems, all sectors are arranged from
left to right in sequence. For example, the three sectors 900 MHz are arranged in
G1/G2/G3 and the three sectors in 1800 MHz are arranged in G7/G8/G9.
The MRFU, GRFU, and WRFU work in RX diversity mode by default. One sector
is configured with a minimum of one antenna system, which consists of two
single-polarized antennas or one dual-polarized antenna and two feeders. The
single sector with no more than two modules is configured with only one antenna
system. In the single sector with more than two modules, every two modules are
configured with one antenna system.
Each sector is configured with a minimum number of antenna systems.
The slot configuration principles and cable connections in this document are not
applied to scenarios in PBT, TX diversity, and 4-way RX diversity modes.
This document does not describe configuration principles for the BTS3900 and
BTS3900A with more than six sectors.
3 Basic Configuration Principles for the CPRI Port
3.1 Overview
3.1.1 Configuration Scope
A maximum of two cabinets are configured.
The MRFU, GRFU, DRFU, and WRFU are called RFU.
The GSM network is classified into single-band network and dual-band network.
3.1.2 Numbering Descriptions
1. The GSM only cells are numbered in sequence with the start number of G1. At
low band, cells are numbered from G1 to G6. At high band, cells are numbered
from G7 to G12.
2. The UMTS only cells are numbered in sequence with the start number of U1,
such as U1, U2, and U3.
3. The GU cells are numbered in sequence with the start number of M1, such as
M1, M2, and M3.
4. The slots are numbered in sequence with the start number of Slot0, such as
Slot0, Slot1, and Slot2. The slot can be positioned through the cabinet No. and
slot No., Slot1 of Cabinet1 for example.
5. Numbering of WBBP CPRI ports: The WBBPb and WBBPd are not
differentiated. The WBBPs in Slot3 on the BBU are numbered from left to right
2023-4-17 Huawei Confidential Page 6 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
with the start number of U-CPRI0. The WBBPs in Slot2 are numbered from left to
right with the start number of U-CPRI3.
6. Numbering of GSM CPRI ports: The GTMUs are consistent with ports numbered
from G-CPRI0 to G-CPRI5. The UBRIs are consistent with ports numbered from
G-CPRI6 to G-CPRI11.
3.1.3 Descriptions on Site Type Name
The configuration principles for the dual-band GSM BTSs are based on the 900 MHz
and 1800 MHz dual-band topologies. The configuration principles for 850 MHz, 1900
MHz, and other dual-band topologies are similar. In this document, the 900 MHz site
connects to 1800 MHz site by &. For example, in GSM S4/4/4&S4/4/4+UMTS S1/1/1,
GSM S4/4/4&S4/4/4 indicates that the dual-band GSM shares one site and GSM
S4/4/4&S4/4/4 shares one site with UMTS S1/1/1.
For example, in S2/2/2 (1G+1G+1G), S2/2/2 indicates the site type. G indicates the
module type. Wherein, G indicates the GRFU, W indicates the DRFU, and M
indicates the MRFU. In this case, 2G indicates two GRFUs.
3.2 Configuration Principles for the CPRI Port
7. The GTMU CPRI ports are consistent with slots in Cabinet 1 in sequence. That
is, Slot0 of Cabinet1 connects to G-CPRI0 and Slot1 connects to G-CPRI1.
8. The UBRI CPRI ports are consistent with slots in Cabinet 2 in sequence. That is,
Slot0 of Cabinet2 connects to G-CPRI6 and Slot1 connects to G-CPRI7.
9. The WBBPb CPRI ports are consistent with UMTS sectors. The WBBPb CPRI
ports are consistent with slots of Cabinet1 in sequence.
10. The slot configurations and cable connections are specified according to
scenarios. The basic configuration principles can be applied to most scenarios.
2023-4-17 Huawei Confidential Page 7 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
4 Slot Configurations and Cable Connections in
Scenarios Only with MRFUsThis section describes internal cable connections and slot configuration principles in
scenarios only with MRFUs in terms of layouts and typical site types, serving as test
cases.
In scenarios only with MRFUs in the SRAN3.0 and SRAN5.0, each site (a single
middle-sized cabinet or single RFC) can be configured with a maximum of six
MRFUs.
4.1 Single-Cabinet Single-Band Scenarios
4.1.1 Scenario 1: Single-Band Site with No More Than Three Sectors
In this scenario, no more than three sectors are configured at GSM and UMTS
sites. The slot and sector allocation principles are described as follows:
Sector No. M1 M2 M3
Slot Slot0–Slot1 Slot2–Slot3 Slot4–Slot5
Mapping Between Slots and CPRI Ports
Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 None U-CPRI1 None U-CPRI2 None
WBBPd CPRI U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
2023-4-17 Huawei Confidential Page 8 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Slot Configuration Principles
Preferably, the RFUs are inserted into slots of the local sector. Generally, one sector
is not configured with more than two MRFUs. The typical configurations of GSM
900M S4/4/4+UMTS 900M S1/1/1(1M+1M+1M) are shown in Figure 1, Figure 2.
Figure 1 (WBBPb) GSM 900M S4/4/4+UMTS 900M S1/1/1(1M+1M+1M)
2023-4-17 Huawei Confidential Page 9 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 2 (WBBPd) GSM 900M S4/4/4+UMTS 900M S1/1/1 (1M+1M+1M)
2023-4-17 Huawei Confidential Page 10 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
4.1.2 Scenario 2: Single-Band Site with More Than Three Sectors
In this scenario, the GSM or UMTS is configured with more than three sectors.
The slots are not consistent with the sectors.
Mapping Between Slots and CPRI Ports
Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb
CPRI
U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
WBBPd
CPRI
U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Slot Configuration Principles
The RFUs are installed from left to right in sequence. The typical configurations of
GSM 900M S4/4/4/4/4/4+UMTS 900M S1/1/1/1/1/1 (1M+1M+1M+1M+1M+1M) are
shown in Figure 3 and Figure 4.
Figure 3 (WBBPb) GSM 900M S4/4/4/4/4/4+UMTS 900M S1/1/1/1/1/1 (Each sector
is configured with one MRFU)
2023-4-17 Huawei Confidential Page 11 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 4 (WBBPd) GSM 900M S4/4/4/4+UMTS 900M S1/1/1/1 (1M+1M+1M+1M)
2023-4-17 Huawei Confidential Page 12 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
4.2 Single-Cabinet Dual-Band Scenarios
4.2.1 Scenario 3: Dual-Band Site with No More Than Three Sectors
The slot configuration principles and cable connections in scenario 3 are the
same as those in scenario 2. The typical configurations of GSM 900M S4/4/4 &
GSM 1800M S4/4/4+UMTS 900M S1/1/1 & UMTS 1800M S1/1/1
(1M+1M+1M+1M+1M+1M) are shown in Figure 5 and Figure 6.
Figure 5 (WBBPb) GSM 900M S4/4/4& GSM 1800M S4/4/4+UMTS 900M S1/1/1
(Each sector is configured with one MRFU)
2023-4-17 Huawei Confidential Page 13 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 6 (WBBPd) GSM 900M S4/4/4& GSM 1800M S4/4/4+UMTS 900M S1/1/1
(Each sector is configured with one MRFU)
5 Slot Configuration Principles and Cable
Connections in Scenarios with Co-Cabinet MRFU,
DRFU, GRFU, and WRFUThis chapter describes the new, swapped, or expanded sites with MRFUs. It is not
applied to scenarios expanded from DRFU/GRFU+WRFU to
DRFU/GRFU+WRFU+MRFU. If you have such special requirement, contact the R&D
Dept.
2023-4-17 Huawei Confidential Page 14 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
5.1 Single-Band Scenario
The SDR and other RFUs cannot be installed in one cabinet at single-band.
According to the product configuration principles, the modules at the same band must
be of the same type. If you need to configure different modules at the same band,
contact the R&D Dept. For example, at the dual-mode site (GSM 900M
S4/4/4/4+UMTS 900M S1/1/1), the GSM has four sectors and the UMTS only has
three sectors. The sector in GSM only mode must be configured with MRFUs rather
than GRFUs or DRFUs.
5.2 Dual-Band Scenarios with Co-Cabinet MRFUs and GRFUs/DRFUs
5.2.1 Scenario 4: Single-Cabinet with No More Than Three Sectors at All Bands
In this scenario, both the GSM and the UMTS are configured with no more than
three sectors and the number of modules in each sector does not exceed one. If
the number of modules exceeds one, you can refer to principles in Scenario 5.
Mapping Between Slots and Sectors
Sector No. M1 G1 M2 G2 M3 G3
Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
Mapping Between Slots and CPRI Ports
Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb
CPRI
U-CPRI0 U-CPRI1 U-CPRI2
WBBPd
CPRI
U-CPRI0 U-CPRI2 U-CPRI4
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Slot Configuration Principles
Preferably, modules are installed according to slot and sector allocation principles. If
the allocated slots are not sufficient for modules of a certain cell, the idle slots on the
left are used. In this case, modules originally occupying such slots are removed to
next slots. For example, the 900 MHz is configured with MRFUs and 1800 MHz is
configured with GRFUs/DRFUs.
2023-4-17 Huawei Confidential Page 15 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 7 (WBBPb) GSM 900M S2/2/2& GSM 1800M S4/4/4+UMTS 900M S1/1/1
Figure 8 (WBBPd) GSM 900M S2/2/2& GSM 1800M S4/4/4+UMTS 900M S1/1/1
2023-4-17 Huawei Confidential Page 16 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
5.2.2 Scenario 5: Single-Cabinet Site with More Than Three Sectors at One Band
In this scenario, more than three sectors are configured at one band at GSM and
UMTS sites. The slots are not consistent with the sectors.
Mapping Between Slots and CPRI Ports (The WBBP only connects to the
MRFU)
Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb
CPRI
U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
WBBPd
CPRI
U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Slot Configuration Principles
One idle slot is left between two bands. Other modules are installed from left to right
in sequence, as shown in Figure 9 and Figure 10.
Figure 9 (WBBPb) GSM 900M S2/2/2/2 & GSM 1800M S4/0/0+UMTS 900M S1/1/1/1
2023-4-17 Huawei Confidential Page 17 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 10 (WBBPd) GSM 900M S2/2/2 & GSM 1800M S4/4/4+UMTS 900M S1/1/1
5.2.3 Scenario 6: Dual-Cabinet Site with Non-Inter-Cabinet GRFUs/DRFUs and No More Than Three Sectors at All Bands
In this scenario, one band occupies one cabinet. In the SRAN3.0, the WBBPb
supports a maximum of six MRFUs in three sectors. In the SRAN5.0, the WBBPb
supports a maximum of six MRFUs in six sectors.
Mapping Between Slots and CPRI Ports
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 None U-CPRI1 None U-CPRI2 None
WBBPd CPRI U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
2023-4-17 Huawei Confidential Page 18 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Slot in Cabinet 2 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI None None None None None None
WBBPd CPRI None None None None None None
UBRI CPRI G-CPRI6 G-CPR7 G-CPR8 G-CPR9 G-CPRI0 G-CPRI1
Slot Configuration Principles
In cabinet 1, slots are allocated according to principles for scenarios only with single-
cabinet MRFUs. In cabinet 2, slots are allocated according to principles for scenarios
only with single-cabinet GRFUs/DRFUs, as shown in Figure 11 and Figure 12.
Figure 11 (WBBPb) GSM 900M S2/2/2 & GSM 1800M S8/8/8+UMTS 900M S1/1/1
(Each 900 MHz sector is configured with one MRFU and each 1800 MHz sector is
configured with two GRFUs.)
2023-4-17 Huawei Confidential Page 19 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 12 (WBBPd) GSM 900M S4/4/4& GSM 1800M S8/8/8+UMTS 900M S2/2/2
(Each 900 MHz sector is configured with two MRFUs and each 1800 MHz sector is
configured with two MRFUs.)
5.2.4 Scenario 7: Dual-Cabinet Site with Non-Inter-Cabinet GRFUs/DRFUs and More Than Three Sectors at One Band
In the SRAN3.0, only three sectors can be configured with the MRFUs. More than
three sectors can be configured with the GRFUs/DRFUs.
In the SRAN5.0, More than three and fewer than six sectors can be configured with
MRFUs or GRFUS/DRFUs.
Slot Configuration Principles
In cabinet 1, slots are allocated according to principles for scenarios only with single-
cabinet MRFUs. In cabinet 2, slots are allocated according to principles for scenarios
only with single-cabinet GRFUs/DRFUs.
Mapping Between Slots and CPRI Ports
Same as the mapping in section 5.2.3
2023-4-17 Huawei Confidential Page 20 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
5.2.5 Scenario 8: Dual-Cabinet with Inter-Cabinet GRFUs/DRFUs and No More Than Three Sectors at All Bands
In this scenario, the number of MRFUs should not exceed three. When more than
three MRFUs are required in this scenario, you need to contact the R&D Dept.
Mapping Between Slots and Sectors
Sector No. M1 M2 M3 G1 G2 G3
Slot in Cabinet 1 Slot0 Slot2 Slot4 Slot1 Slot3 Slot5
Slot in Cabinet 2 None None None Slot0, Slot1 Slot2, Slot3 Slot4, Slot5
Mapping Between Slots and CPRI Ports
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 Idle U-CPRI1 Idle U-CPRI2 Idle
WBBPd CPRI U-CPRI0 Idle U-CPRI2 Idle U-CPRI4 Idle
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Slot in Cabinet 2 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI Idle Idle Idle Idle Idle Idle
WBBPd CPRI Idle Idle Idle Idle Idle Idle
UBRI CPRI G-CPRI6 G-CPR7 G-CPR8 G-CPR9 G-CPRI0 G-CPRI1
2023-4-17 Huawei Confidential Page 21 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Slot Configuration Principles
In cabinet 1, slots are allocated according to principles for single-cabinet and co-
cabinet scenarios. In cabinet 2, slots are allocated according to principles for single-
cabinet scenarios only with GRFUs/DRFUs, as shown in Figure 13.
Figure 13 (WBBPb) GSM 900M S2/2/2& GSM 1800M S12/12/12+UMTS 900M
S1/1/1 (Each 900 MHz sector is configured with one MRFU and each 1800 MHz
sector is configured with three GRFUs.)
5.2.6 Scenario 9: Dual-Cabinet Site with Inter-Cabinet GRFUs/DRFUs and More Than Three Sectors at One Band
In the SRAN3.0, only three sectors can be configured with MRFUs. More than three
sectors can be configured with GRFUs/DRFUs.
In the SRAN5.0, more than three and fewer than six sectors can be configured with
MRFUs or GRFUs/DRFUs.
The slots are not specific to sectors.
Mapping Between Slots and CPRI Ports
2023-4-17 Huawei Confidential Page 22 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
The WBBP CPRI ports are inconsistent with slots. Ports are consistent with MRFUs
from left to right in sequence.
Mapping Between the GTMU/UBRI CPRI Ports and the Slots
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Slot in Cabinet 2 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
UBRI CPRI G-CPRI6 G-CPR7 G-CPR8 G-CPR9 G-CPRI0 G-CPRI1
Slot Configuration Principles
Figure 14 The MRFUs are installed from left to right in sequence in Cabinet 1. Then,
the GRFUs/DRFUs in the northbound sector are installed. After Cabinet 1 slots are all
occupied, slots in Cabinet 2 are used in sequence.
2023-4-17 Huawei Confidential Page 23 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
5.3 Dual-Band Scenario with Co-Cabinet MRFU and WRFU
5.3.1 Scenario 10: Single-Cabinet Site with No More Than Three Sectors at Dual-Band
Mapping Between Slots and Sectors
Sector No. M1 W1 M2 W2 M3 W3
Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
Mapping Between Slots and CPRI Ports
Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 U-CPRI3 U-CPRI1 U-CPRI4 U-CPRI2 U-CPRI5
WBBPd CPRI U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
GTMU CPRI G-CPRI0 Idle G-CPRI2 Idle G-CPRI4 Idle
Cases
Figure 15 (WBBPb) GSM 900M S2/2/2+UMTS 900M S1/1/1+ UMTS 2100M S1/1/1
(Each 900 MHz sector is configured with one MRFU and each 2100 MHz sector is
configured with one WRFU.)
2023-4-17 Huawei Confidential Page 24 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 16 (WBBPd) GSM 900M S2/2/2+UMTS 900M S1/1/1+ UMTS 2100M S1/1/1
(Each 900 MHz sector is configured with one MRFU, and each 2100 MHz sector is
configured with one WRFU.)
5.3.2 Scenario 11: Dual-Cabinet Site with No More Than Three Sectors at Dual-Band
In this scenario, the total number of modules at a single band should not exceed six.
Mapping Between Slots and Sectors
Sector No. M1 M2 M3 W1 W2 W3
Slot in Cabinet 1 Slot0–1 Slot2–3 Slot4–5 None None None
Slot in Cabinet 2 None None None Slot0–1 Slot2–3 Slot4–5
Mapping Between Slots and CPRI Ports
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 Idle U-CPRI1 Idle U-CPRI2 Idle
WBBPd CPRI U-CPRI0 Idle U-CPRI2 Idle U-CPRI4 Idle
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
2023-4-17 Huawei Confidential Page 25 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI3 Idle U-CPRI4 Idle U-CPRI5 Idle
WBBPd CPRI Idle U-CPRI1 Idle U-CPRI3 Idle U-CPRI5
Slot Configuration Principles
Preferably, the WRFUs are inserted into Slot1, Slot3, and Slot5 in Cabinet 2 and the
MRFUs are inserted into Slot0, Slot2, and Slot4 in Cabinet 1.
Figure 17 6MRFU(three sectors)+3WRFU
2023-4-17 Huawei Confidential Page 26 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 18 6MRFU(three sectors)+6WRFU(three sectors)
5.3.3 Scenario 12: Dual-Cabinet Site with More Than Three Sectors at One Band
This scenario is not involved in the SRAN3.0.
The configurations of six sectors + six sectors can be supported in the SRAN5.0.
In this scenario, the total number of modules at a single band should not exceed six.
Mapping Between Slots and Sectors
Sector No. M1 M2 M3 W1 W2 W3
Slot in Cabinet 1 Slot0–1 Slot2–3 Slot4–5 None None None
Slot in Cabinet 2 None None None Slot0–1 Slot2–3 Slot4–5
Mapping Between Slots and CPRI Ports
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 Idle U-CPRI1 Idle U-CPRI2 Idle
2023-4-17 Huawei Confidential Page 27 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
WBBPd CPRI U-CPRI0 Idle U-CPRI2 Idle U-CPRI4 Idle
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI3 None U-CPRI4 None U-CPRI5 None
WBBPd CPRI None U-CPRI1 None U-CPRI3 None U-CPRI5
Figure 19 SRAN5.0 6MRFU(six sectors)+6WRFU (six sectors)
2023-4-17 Huawei Confidential Page 28 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
5.4 Three-band MRFU and GRFU/DRFU Sharing the Cabinet with WRFU
This chapter describes the new, swapped, or expanded sites with MRFUs. It is not
applied to scenarios expanded from DRFU/GRFU+WRFU to
DRFU/GRFU+WRFU+MRFU. If you have such special requirement, contact the R&D
Dept.
The co-cabinet MRFU+GRFU/DRFU+WRFU must be of different bands, 900 MHz
MRFU+1800 MHz GRFU+2100 MHz WRFU, for example. In this co-cabinet scenario,
more than one cabinet must be configured. In the SRAN3.0, the number of sectors
should not exceed three. Such scenario with complicated configurations is few. If you
have special requirement, contact the R&D Dept.
Different expansion paths may bring differences in the target site configurations,
which are described in this chapter.
5.4.1 New and Swapped Scenarios with Co-Cabinet MRFU, GRFU/DRFU, and WRFU
The principles are also applied to scenarios expanded from MRFU+GRFU/DRFU to
MRFU+GRFU/DRFU+WRFU.
5.4.1.1 Scenario 13: Dual-Cabinet Site with No More Than Three Sectors at All Bands
In sectors with MRFUs and DRFUs/GRFUs, each sector is configured with no more
than one module. For sectors requiring more than one such module, you need to
contact the R&D Dept.
Mapping Between Slots and Sectors
Sector No. M1 M2 M3 G1 G2 G3 W1 W2 W3
Slot in Cabinet 1 Slot0 Slot2 Slot4 Slot1 Slot3 Slot5 None None None
Slot in Cabinet 2 None None None None None None Slot0,
Slot1
Slot2,
Slot3
Slot4,S
lot5
Mapping Between Slots and CPRI Ports
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 None U-CPRI1 None U-CPRI2 None
WBBPd CPRI U-CPRI0 U-CPRI2 U-CPRI4
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
2023-4-17 Huawei Confidential Page 29 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Slot in Cabinet 2 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI None U-CPRI3 None U-CPRI4 None U-CPRI5
WBBPd CPRI None U-CPRI1 None U-CPRI3 None U-CPRI5
Slot Configuration Principles
In cabinet 1, slots are allocated according to principles for Scenario 4 (single-cabinet
and co-cabinet). In cabinet 2, three WRFUs are preferably installed in slot1, slot3, and
slot5 in Cabinet 2 and six WRFUs are installed in sequence.
SRAN3.0
Figure 20 3MRFU+3GRFU+3WRFU
2023-4-17 Huawei Confidential Page 30 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 21 3MRFU+3GRFU+6WRFU
SRAN5.0
Figure 22 3MRFU+3GRFU+3WRFU
2023-4-17 Huawei Confidential Page 31 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 23 3MRFU+3GRFU+6WRFU
2023-4-17 Huawei Confidential Page 32 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 24 6MRFU+3GRFU+3WRFU
5.4.1.2 Scenario 14: Dual-Cabinet Site with More Than Three Sectors at One Band
Only the SRAN5.0 supports this scenario.
Sub-scenario 1: When the number of sectors with GRFUs exceeds three and the
number of modules does not exceed six, only 3MRFU+6GRFU+3WRFU and lower
configurations are considered.
Mapping Between Slots and Sectors
Sector No. M1 M2 M3 G1 G2 G3 W1 W2 W3
Slot in Cabinet 1 Slot0 Slot2 Slot4 None None None Slot0 Slot3 Slot5
Slot in Cabinet 2 None None None Slot0,
Slot1
Slot2,S
lot3
Slot4,
Slot5
None None None
Mapping Between Slots and CPRI Ports
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPd CPRI U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
GTMU CPRI G-CPRI0 Idle G-CPRI2 Idle G-CPRI4 Idle
2023-4-17 Huawei Confidential Page 33 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Slot in Cabinet 2 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
UBRI CPRI G-CPRI6 G-CPRI7 G-CPRI8 G-CPRI9 G-CPRI10 G-CPRI11
Cases
Figure 25 3MRFU+6GRFU (six sectors) + 3WRFU
Sub-scenario 2: When the number of sectors with WRFUs exceeds three and the
number of modules does not exceed six, only 3MRFU+3GRFU+6WRFU and lower
configurations are considered.
Mapping Between Slots and Sectors
Sector No. M1 M2 M3 G1 G2 G3 W1 W2 W3
Slot in
Cabinet 1
Slot0 Slot2 Slot4 None None None Slot0 Slot3 Slot5
Slot in
Cabinet 2
None None None Slot0,
Slot1
Slot2,
Slot3
Slot4,
Slot5
None None None
2023-4-17 Huawei Confidential Page 34 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Mapping Between Slots and CPRI Ports
Slot in Cabinet 1 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPd CPRI U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
GTMU CPRI G-CPRI0 Idle G-CPRI2 Idle G-CPRI4 Idle
Slot in Cabinet 2 Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
UBRI CPRI G-CPRI6 G-CPRI7 G-CPRI8 G-CPRI9 G-CPRI10 G-CPRI11
Cases
Figure 26 3MRFU+3GRFU+6WRFU (six sectors)
2023-4-17 Huawei Confidential Page 35 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
5.4.2 Scenarios Expanded from MRFU+WRFU to MRFU+WRFU+GRFU/DRFU at Other Bands
Only principles for the following typical configurations are described. For other
configurations, you need to contact the R&D Dept.
Figure 27 3MRFU+3WRFU→→3MRFU+3WRFU+3GRFU
→→
2023-4-17 Huawei Confidential Page 36 of 37
Guide to BTS3900 and BTS3900A SDR and RFU Co-Cabinet Slot Configuration Principles and Internal Cable Connections Internal
Figure 28 3MRFU+3WRFU→→3MRFU+3WRFU+6GRFU
→→6 Appendix
Release Path
References
Configuration Principles of DRFU Slot and Guide to Internal Cable Connections for