Glucose biosensors1
-
7/27/2019 Glucose Biosensors Final
2/13
WORKING OF A BIOSENSOR2
BIORECEPTOR NUCLEIC ACIDS,TISSUES.,ETC
TRANSDUCER OPTICAL TRANSDUCER,PIEZOELECTRIC
CRYSTALS
AMPLIFIER
DIGITALDISPLAY
-
7/27/2019 Glucose Biosensors Final
3/13
BIO-RECEPTOR
Includes a species of biological origin such as enzyme,antibody or DNA strand
The bio-receptor must be capable of recognizing theanalyte of interest with a high degree.
i.e. binding between a receptor and analyte takesplace.
3
-
7/27/2019 Glucose Biosensors Final
4/13
TRANSDUCER
Specifications:
4
-
7/27/2019 Glucose Biosensors Final
5/13
TRANSDUCER5
Translates the binding between receptor and analyteinto measureable physical change.
Possible changes are production of electrons,protons or an electrochemical species.
Eg: hydrogen peroxide, change in conductivity.
-
7/27/2019 Glucose Biosensors Final
6/13
SCHEMATIC CONFIGURATION6
-
7/27/2019 Glucose Biosensors Final
7/13
CROSS-SECTIONAL VIEW7
-
7/27/2019 Glucose Biosensors Final
8/13
WORKING
Glucose reacts with glucoseoxidase(GOD) to form gluconicacid. Two electrons & two protonsare also produced.
Glucose mediator reacts withsurrounding oxygen to form H2O2and GOD.
Now this GOD can reacts withmore glucose.
Higher the glucose content, higherthe oxygen consumption.
Glucose content can be detected byPt-electrode.
8
-
7/27/2019 Glucose Biosensors Final
9/13
POLYMERS IN BIOSENSORS9
For determination of glucose, the glucose oxidase isimmobilized in polyaniline.
Aniline is electrochemically polymerized from asolution containing glucose oxidase into platinumelectrodes
RXN
INVOLVED:
-
7/27/2019 Glucose Biosensors Final
10/13
APPLICATIONS
The foremost application of a glucose biosensor is to check the
sugar level in a persons body.
In food industry, these biosensors are used to monitor the
freshness of food.
Keeping glucose levels in check is crucial to minimize theonset of the damage caused by diabetes
Environmental applications e.g. the detection of pesticides and
river water contaminants.
10
-
7/27/2019 Glucose Biosensors Final
11/13
Determination of drug residues in food, such asantibiotics and growth promoters.
Drug discovery and evaluation of biological activity ofnew compounds.
Analytical measurement of folic acid, biotin, vitamin
B12 and pantothenic acid.
Using bacteria researcher can detect pollutants insamples.
11
-
7/27/2019 Glucose Biosensors Final
12/13
DRAWBACKS12
The monitoring systems currently in general usehave the drawback of below optimal number ofreadings, due to their reliance on a drop of fresh
blood.
Some continuous glucose monitors arecommercially available, but suffer from the severedrawback of a short working life of the probe.
-
7/27/2019 Glucose Biosensors Final
13/13
13