Evan & Ryan Contractors | Evan & Ryan Contractors
Transcript of Evan & Ryan Contractors | Evan & Ryan Contractors
CHARGING VALVE
SIGHT GLASS
FILTER-DRYER
BARE PIPE IN COVER
RADIATION COVER ONLY
FINNED TUBE RADIATION
FINNED TUBE RADIATION IN COVER
THERMOSTATIC EXPANSION VALVE
EVAPORATOR PRESSURE REGULATOR
MANUAL REFRIGERATION VALVE
STRAINER
FLANGED CONNECTION
SIAMESE HOSE CONNECTION
PIPE ANCHOR
EXPANSION JOINT
PIPE ALIGNMENT GUIDES
UNION
END CAP
CONCENTRIC REDUCER
TEE DOWN
TEE UP
ELBOW DOWN
ELBOW UP
TEMPERATURE SENSOR
HUMIDISTAT
DUCT THERMOSTAT (ELECTRIC)
ROOM THERMOSTAT (HEAT/COOL)
ROOM THERMOSTAT (COOL)
DUCT THERMOSTAT (PNEUMATIC)
FLOW METER
MOTORIZED DAMPER
DIFFERENTIAL PRESSURE TRANSMITTER
ROOM THERMOSTAT (HEAT)
SAFETY/PRESSURE RELIEF VALVE
FLOW CONTROL VALVE
MAKEUP WATER VALVE
PRESSURE REDUCING VALVE
CHECK VALVE
BALANCING VALVE
VERTICAL SHUT-OFF/IN VERTICAL PIPE
SHUT-OFF VALVE
SHOCK ABSORBER
AIR CHAMBER
(DOWN IN ARROW DIRECTION)PIPE PITCH ARROW
PRESSURE GAUGE
AUTOMATIC AIR VENT
COMPOUND GAUGE
FLEX CONNECTOR
CONDENSER WATER RETURN
GROUND LOOP WATER RETURN
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION
REFRIGERANT LIQUID
CONDENSER WATER SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
GROUND LOOP WATER SUPPLY
PENDANT SPRINKLER HEAD
UPRIGHT SPRINKLER HEAD
FIRE PROTECTION PIPING
POST INDICATOR VALVE
FIRE HYDRANT
FUEL OIL RETURN
FUEL OIL SUPPLY
INVERTED BUCKET TRAP
FLOAT & THERMOSTATIC TRAP
HEATING WATER RETURN
HEATING WATER SUPPLY
LOW PRESSURE CONDENSATE RETURN
LOW PRESSURE STEAM
RETURN OR EXHAUST DUCT DOWN
RETURN OR EXHAUST DUCT UP
FIRE DAMPER (FD) IN DUCT
SUPPLY DUCT DOWN
VOLUME DAMPER
SUPPLY DUCT UP
FUEL OIL VENT
FLOW ARROW
TEMP/PRESSURE RELIEF VALVE
CONCEALED SPRINKLER HEAD
DRY STANDPIPE
DRY PIPE SPRINKLER PIPING
PRE-ACTION SPRINKLER PIPING
ELBOW
TEE
CLEANOUTS
FLOOR DRAIN
STORM WATER (SUSPENDED)
TEMPERED WATER
GAS
DRAIN LINE
SANITARY WASTE (SUSPENDED)
SANITARY WASTE (BURIED)
SANITARY VENT LINE
STORM WATER (BURIED)
COLD SOFT WATER
HOT WATER (180° F)
HOT WATER RETURN (140° F)
HOT WATER (140° F)
HOT WATER RETURN
HOT WATER
140°
GAS METER
WATER METER
TAMPER SWITCH
FLOW SWITCH
PIPE SLEEVE
HOT SOFT WATER
HOT SOFT WATER RETURN
CONTROL VALVE (TCV)
3-WAY CONTROL VALVE
WET FIRE PROTECTION PIPING
REFRIGERANT HOT GAS
HOT WATER RETURN (180° F)
MEDIUM PRESSURE STEAM
HIGH PRESSURE STEAM
MEDIUM PRESSURE CONDENSATE RETURN
HIGH PRESSURE CONDENSATE RETURN
THERMOSTATIC TRAP
THROTTLING VALVE
PETE'S PLUG
FD
CARBON DIOXIDE SENSOR
VARIABLE FREQUENCY DRIVE
TEMPERATURE CONTROL PANEL
ACCESS PANEL
BOILER FEED WATER
EMERGENCY BOILER FEED WATER
COLD WATER
140°
180°
180°
T
CSW
HSW
HSWR
NON-POTABLE WATERNPW
G
AIR (WITH PSI)A
D
GM
WM
RPBPRPZ
(REDUCED PRESSUREBACKFLOW PREVENTER)
CS
CR
CHWS
CHWR
GS
GR
{
HS
HR
FOS
FOR
FOV
RD
RS
RL
RHG
DUAL TEMPERATURE SUPPLYDTS
DUAL TEMPERATURE RETURNDTR
BFW
EBFW
LPS
MPS
HPS
LPR
MPR
HPR
CONDENSATE PUMP DISCHARGEPD
CONDENSATE RETURNCR
F&T
IB
T
ECCENTRICAL REDUCER
CO
FD
D
F
DS
DP
PA
WP
PIV
TS
FS
COMBINATION FIRE/SMOKE DAMPER(FSD) IN DUCT
FSD
SD
SMOKE DAMPER (SD) IN DUCT
AP
INTERNAL LINED DUCT
CO2
FLOW SWITCHFS
FM
DPT
M
VFD
TCP
WELL WATERWW
8"E.
DENOTEDEXISTINGWORK
CONNECTIONTO EXISTING
SECTION OR ELEVATIONNUMBER
THERMOMETERT
S
TH
TH,C
TC
T
TE
H
T
DENOTEDNEW WORK
SIZE OFPIPE ORDUCT
DENOTEDEXISTING
SHEET NUMBER OFSECTION OR ELEVATION
DETAIL (LETTER)
SHEET NUMBER OFDETAIL LOCATION
ADAFCAFFAHRAHUALTAPAS
BDBDDBTUBV
CBCICLCOCONDCONVCUHCW
DBDFDIADIFFDSDXC
EAEATEBBRECEGECONVECUHEFELECELEVEOMEPUHERERCPESPEWCEWHEXPTE.
FDFPVAVFOBFSDFTR
GCGEN
HBHTGHWHWRHYD
IDINV. EL.
LATLAV
MBHMECHMHMCMSMUV
NCNO
OAOADOBDODORDOSD
PFHXPIVPLBGPRVPUH
RARADRCPRCNPRDRECIRCRGRPZRRRIVRRV
SASANSDSGSHDRSKSRSSSTHX
TCCTCPTGTOTPTYP
UR
VAVVCPVFDVSVSDVTR
WWBWCWS
ABBREVIATIONSTEMPERATURE CONTROL/MONITORING
DRAWING NOTATIONS
SECTIONS AND DETAILS
RADIATION SYMBOLS
DUCT SYMBOLS
FIRE PROTECTION SYSTEM
STEAM PIPING
HVAC PIPING
VALVES
REFRIGERATION VALVES/FITTINGS
PLUMBING
PIPE FITTINGS
GENERAL NOTES1. ALL NEW WORK IS DRAWN DARK. ALL WORK DRAWN LIGHT AND FOLLOWED
BY (E.) IS EXISTING. ALL WORK SHALL REMAIN UNLESS SPECIFICALLYNOTED OTHERWISE.
2. THESE NOTES APPLY TO EACH AND EVERY 'M' AND 'FP' SERIES DRAWINGS.
3. FIELD VERIFY ALL EXISTING CONDITIONS AS TO EXACT SERVICE, LOCATION,TYPE OF MATERIAL, ETC. BEFORE BIDDING AND BEFORE BEGINNINGRENOVATION WORK.
4. COORDINATE ALL SHUT-DOWNS, DELIVERY, AND STORAGE OF MATERIALS,ETC. WITH OWNER'S REPRESENTATIVE.
5. CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURINGCONSTRUCTION. ANY AND ALL OWNER FACILITIES DAMAGED ORDISCONNECTED BY CONTRACTOR OPERATIONS SHALL BE FULLYRESTORED TO PREVIOUS OPERATING AND APPEARANCE CONDITION BYCONTRACTOR.
6. PROVIDE SLEEVES FOR ALL PIPING AND DUCTWORK THAT PENETRATESFULL HEIGHT WALLS, WHETHER SHOWN OR NOT. HOLES THROUGHEXISTING WALLS TO BE CORE DRILLED OR DRILLED WITH HOLE SAW.
7. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARENOTED ON THOSE DRAWINGS.
8. ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE M400 SERIES DRAWINGSSCHEDULES.
9. SMOKING, ALCOHOL, DRUGS, WEAPONS, AND CONTRABAND ARE STRICTLYFORBIDDEN ON JOB SITE PROPERTY.
10. CONTRACTOR SHALL PROVIDE PLATING AS REQUIRED TO PROTECTSURFACE OF EXISTING ASPHALT PARKING LOT. PROVIDE PLATES UNDERWHEELS OF DUMPSTER, LIFTING DEVICES, AND ANY OTHER EQUIPMENTTHAT COULD SINK INTO THE ASPHALT.
11. FIELD VERIFY EXACT SIZES OF EXISTING PIPING AND DUCT SYSTEMSSHOWN TO BE CONNECTED TO NEW WORK. IN THE EVENT ACTUAL SIZEIS DIFFERENT THAN SHOWN ON DRAWINGS, CONTACT ENGINEER FORDIRECTION PRIOR TO ANY WORK.
12. FOR WALLS THAT GO TO DECK, REFERENCE THE 'A' SERIES DRAWINGS.CONTRACTOR SHALL PROVIDE ACOUSTIC SEALANT AROUND ALL DUCT ANDPIPE PENETRATIONS THROUGH FULL HEIGHT WALLS.
ACID WASTE (SUSPENDED)
ACID WASTE (BURIED)
CONDENSATE DRAINCD
C
FCV
SHUT-OFF VALVE
AREA DRAINAUTOMATIC FLOW CONTROLABOVE FINISHED FLOORAIR HOSE REELAIR HANDLING UNITALTERNATEACCESS PANELAIR SEPARATOR
BLOWDOWNBACKDRAFT/PRESSURE RELIEF DAMPERBRITISH THERMAL UNITBALANCE VALVE
CATCH BASINCAST IRONCENTERLINECLEANOUTCONDENSATEHYDRONIC CONVECTORCABINET UNIT HEATERCOLD WATER
DRY BULBDRINKING FOUNTAINDIAMETERDIFFUSERDOWNSPOUTDIRECT EXPANSION COOLING COIL
EXHAUST AIRENTERING AIR TEMPERATUREELECTRIC BASEBOARD RADIATIONELECTRICAL CONCTRACTOREXHAUST GRILLEELECTRIC CONVECTORELECTRIC CABINET UNIT HEATEREXHAUST FANELECTRICALELEVATIONEND OF MAIN DRIPELECTRIC PROPELLER UNIT HEATEREXHAUST REGISTERELECTRIC RADIANT CEILING PANELEXTERNAL STATIC PRESSUREELECTRIC WATER COOLERELECTRIC WATER HEATEREXPANSION TANKEXISTING
FLOOR DRAIN OR FIRE DAMPERFAN POWERED VAVFLAT ON BOTTOMCOMBINATION FIRE/SMOKE DAMPERHYDRONIC FINNED TUBE RADIATION
GENERAL CONTRACTORGENERAL
HOSE BIBBHEATINGHOT WATERHOT WATER RETURNWALL HYDRANT
INTERNAL DIAMETERINVERTED ELEVATION
LEAVING AIR TEMPERATURELAVATORY
1000 BTU/HOURMECHANICALMANHOLEMECHANICAL CONTRACTORMOP SINKAUTOMATIC MAKE-UP VALVE
NORMALLY CLOSEDNORMALLY OPEN
OUTSIDE AIROUTSIDE AIR DAMPEROPPOSED BLADE DAMPEROUTSIDE DIAMETEROVERFLOW ROOF DRAINOPEN SITE DRAIN
PLATE AND FRAME HEAT EXCHANGERPOST INDICATOR VALVEPLUMBINGPRESSURE REDUCING VALVEPROPELLER UNIT HEATER
RETURN AIRRETURN AIR DAMPERHYDRONIC RADIANT CIELING HEATING PANELREINFORCED CONCRETE PIPEROOF DRAINRECIRCULATINGRETURN GRILLEREDUCED PRESSURE BACKFLOW PREVENTERRETURN REGISTERROOF INTAKE VENTROOF RELIEF VENT
SUPPLY AIRSANITARYSMOKE DAMPERSUPPLY GRILLESHOWER DRAINSINKSUPPLY REGISTERSTAINLESS STEELSHELL AND TUBE HEAT EXCHANGER
TEMPERATURE CONTROL CONTRACTORTEMPERATURE CONTROL PANELTRANSFER GRILLETRANSFER OPENINGTRAP PRIMER LINETYPICAL
URINAL
VARIABLE AIR VOLUMEVETRIFIED CLAY PIPEVARIABLE FREQUENCY DRIVEVENT STACKVARIABLE SPEED DRIVEVENT THROUGH ROOF
WASTEWET BULBWATER CLOSETWASTE STACK
ROOM NUMBERUNITUNDERLINED REPRESENTSSCHEDULED EQUIPMENTFAN COIL CFMFAN COIL SIZE
UNIT/AREA LOCATION IN BUILDINGNUMBER OF AHU IN UNITUNDERLINED REPRESENTSSCHEDULED EQUIPMENT
UNIT/AREA LOCATION IN BUILDINGNUMBER OF FAN IN UNITUNDERLINED REPRESENTSSCHEDULED EQUIPMENTFAN COIL CFM
UNIT/AREA LOCATION IN BUILDING
UNDERLINED REPRESENTSSCHEDULED EQUIPMENTVAV CFMVAV SIZE - SEE SCHEDULE
DRAWN TO SCALE (ACTUAL SIZE)ACTUAL SIZE
SQUARE DIFFUSER DRAWN TOSCALE (ACTUAL SIZE)
CFM
CFM
LINEAR SLOT DIFFUSER DRAWNTO SCALE (ACTUAL SIZE)
CFMER - EXHAUST REGISTERRG - RETURN GRILL
SIZESUPPLY REGISTERCFM
FC - FAN COILBC - BLOWER COIL FC-128G
C-1280
AHU-A4
EF-B6400
VAV-123AA-120
FAN COIL
AIR HANDLING UNIT
FAN
VARIABLE AIRVOLUME BOX
DOUBLE DEFLECTIONSUPPLY REGISTER
EXHAUST/RETURN REGISTER
SUPPLY DIFFUSER
RETURN GRILL FOR RETURNAIR PLENUM CEILING
EF - EXHAUST FANSF - SUPPLY FANRF - RETURN FAN
24/12
400
400
1400 ER
28/12 SR;300
NOMENCLATURE FOR SCHEDULED DEVICES(SEE SCHEUDLES M600 SERIES DRAWINGS FOR ADDITIONAL INFORMATION)
VF - VENTILATION FAN
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\MP0
01 -
SYM
BOLS
, ABB
REV
IATI
ON
S, A
ND
GEN
ERAL
NO
TES
- MEC
HAN
ICAL
& P
LUM
BIN
G.d
wg,
5/1/
2018
2:4
5:36
PM
VD
14/1
010
/10
200
200
200
200
50/12
50/12
375
375375
375
175
175
175
175
175
175
175
175
26/10
24/14
18/1
0
10"
10"
10"
10"
8"
8"
8"
8" FLEX TYP. (8)
8"
50/12
8"
8"
8"
8" FLEX TYP. (4)
10" FLEX TYP. (4)
8" FLEX
HS HR
2"
HS HR TWS
TWR
24/12
24/12
TWS
TWR
FPVAV
FPVAV
FPVAV
8"
8"FPVAV
24/24
BY CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS
24/12
CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING
24/12
24/12
24/12
24/12
AND FEDERAL REGULATIONS.
TO OWNER.
WITH OWNER'S REPRESENTATIVE.
GENERAL NOTES - DEMOLITION:
OPERATING AND APPEARANCE CONDITION BY THE CONTRACTOR.
MECHANICAL CONTRACTOR SHALL PATCH ALL HOLES LEFT BY REMOVAL OF
CONSTRUCTION. ANY AND ALL OWNER FACILITIES DAMAGED OR DISCONNECTED
COORDINATE ALL SHUT-DOWNS, DELIVERY AND STORAGE OF MATERIALS, ETC.
OR RENOVATION TO MATCH ORIGINAL CONDITION.REPAIR OR REPLACE PIPE AND DUCT INSULATION DAMAGED DURING DEMOLITION
REMOVE ALL HANGERS, STRAPS, BRACKETS, PIPE SUPPORTS, ANCHORS,
OF MATERIAL, ETC. BEFORE BIDDING AND BEFORE BEGINNING ANY DEMOLITION.FIELD VERIFY ALL EXISTING CONDITIONS AS TO EXACT SERVICE, LOCATION, TYPE
DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE
LABELED. ALL PIPING, EQUIPMENT, VALVES, ETC., DRAWN LIGHT SHALL REMAIN.REMOVE ALL PIPING, EQUIPMENT, VALVES, ETC., DRAWN DARK DASHED, AND
DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONAL COSTTHOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOLITION WORK. ANY
CONSTRUCTION SHALL BE REMOVED IN THIS CONTRACT.ALL PIPING DUCTWORK AND EQUIPMENT ABANDONED BY NATURE OF NEW
EXPANSION JOINTS, ETC. ASSOCIATED WITH DUCTWORK AND OR PIPING TO BE
UNLESS SPECIFICALLY NOTED TO BE PERFORMED BY OTHERS. WORK BY OTHERSMECHANICAL OR PLUMBING PIPE, DUCT ETC. IN EXISTING WALLS AND FLOORS.
INDICATED ON 'A' AND 'S' SERIES DRAWINGS. REPAIR SURFACES TO MATCH
11.
10.
REMOVED.
8.
9.
7.
5.
6.
3.
4.
2.
THESE NOTES APPLY TO ALL PLUMBING AND MECHANICAL DEMOLITIONDRAWINGS.
1.
12.
EXISTING SURFACES.
SEE ALSO MP001 FOR GENERAL NOTES.
#
1. REMOVE DIFFUSER/RETURN GRILLE. CLEAN WITH SPRAY CLEANER ANDWIPE CLEAN TO THE SATISFACTION OF THE ENGINEER. SAVE FOR REINSTALLATION. SEE M201
- PLAN NOTES
T
T
T
BULKHEAD7'-8" AFF
1
1 1
1
1 1
1 1
11
1
1
NORTH
LOWER LEVEL PLAN - MECHANICAL DEMOLITIONSCALE: 1/8" = 1'-0"
24/12
24/12
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\MD
201
- LO
WER
LEV
EL P
LAN
- M
ECH
ANIC
AL D
EMO
LITI
ON
.dw
g, 5
/1/2
018
2:45
:07
PM
- PLAN NOTES #
1. REINSTALL EXISTING DIFFUSER/RETURN GRILLE. MODIFY FLEX DUCT ASREQUIRED TO RECONNECT TO SUPPLY DIFFUSERS.
SUPPLY DIFFUSERS TO BE INSTALLED NO CLOSER THAN 4'-0" TO ALL SMOKEDETECTORS. REFER TO T-SERIES AND E-SERIES DRAWINGS FOR ADDITIONALCEILING INSTALLED DEVICES. COORDINATE AND ADJUST DIFFUSER LOCATIONS,
SEE DRAWING M401 FOR CEILING DIFFUSER/EXHAUST AND RETURN REGISTER
FLEX DUCT CONNECTIONS TO DIFFUSERS SHALL BE A MAXIMUM OF 36"
GENERAL NOTES - AIR DISTRIBUTION
2.SCHEDULE.
1.IN LENGTH.
PROVIDE INTERNALLY LINED TRANSFER DUCTS WITH ELBOW IN WALLS OF ALLROOMS ABOVE CEILING WHETHER SHOWN OR NOT.
ALL RETURN GRILLES TO HAVE AN ACOUSTICAL ELBOW. SEEB
M401
3.
4.
7.
THESE ARE NOT FABRICATIONS DRAWINGS. THESE DRAWINGS ARE NOT INTENDEDTO SHOW ALL OFFSETS AS REQUIRED FOR PROPER DUCTWORK INSTALLATION.CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND PREPAREFABRICATION DRAWINGS BASED ON EXISTING CONDITIONS. ALL ADDITIONALOFFSETS SHALL BE INCLUDED IN BID PRICE.
5.
AS NEEDED.
6.
REFERENCE M400 SERIES DRAWINGS FOR TYPICAL AND SPECIFIC INSTALLATION REQUIREMENTS FOR EQUIPMENT, ETC.
8. WORKMANSHIP MUST BE IN COMPLIANCE WITH SMACNA STANDARDS.
9. SEE ALSO MP001 FOR ADDITIONAL GENERAL NOTES.
NORTH
LOWER LEVEL PLAN - MECHANICALSCALE: 1/8" = 1'-0"
VD E.
14/1
0 E.
10/1
0 E.
50/12 E.
50/12 E.
375
375375
375
175
175
175
175
175
175
175
175
26/10 E.
24/14 E.
18/1
0 E.
10" E
.
10" E
.10
" E.
10" E
.
8" E.
8" E.
8" E.
8" FLEX TYP. (2) E.8" E.
50/12 E.
8" E.
8" E.
8" E.
8" FLEX E.
10" FLEX TYP. (4) E.
8" FLEX E.
HS HR
2" E.
HS HR TWS
TWR
TWS
TWR
FPVAV E.
FPVAV E.
8" E.
8" E.FPVAV E.
T
T
1 1
1 1
1 1
1 1
11
1
1
FPVAV E.8" FLEX TYP. (6) E.
8" FLEX TYP. (3) E.
8" E.
24/12
24/12
24/12
24/12
24/12
200
200
200
200
24/12
24/12
24/12
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\M20
1 - L
OW
ER L
EVEL
PLA
N -
AIR
DIS
TRIB
UTI
ON
.dw
g, 5
/1/2
018
2:44
:01
PM
STAINLESS STEEL HOSE CLAMPREQUIRED ON INNER FLEX LAYER
INNER FLEX WALL
OUTER FLEX WALL
NYLON TIE STRAP ON OUTER FLEX LAYER
FOR SIZESEE FLOOR PLANLAY-IN DIFFUSER
SUPPORT FROM STRUCTURE
STRUCTURE
INNER FLEX WALL
OUTER FLEX WALL
FOR SIZESEE FLOOR PLANLAY-IN DIFFUSER
NYLON TIE STRAP ON OUTER FLEX LAYER
STAINLESS STEEL HOSECLAMP REQUIRED ONINNER FLEX LAYER
OPTION 1 - PROVIDE 90° METAL ELBOW FOR FINAL CONNECTIONTO DIFFUSER. PROVIDE STAINLESS STEEL HOSE CLAMP FORCONNECTION TO ALL DIFFUSERS.
OPTION 2 - PROVIDE ONE PIECE, FULLY ADJUSTABLE BRACE.LIKE TITUS FLEXRIGHT OR THERMAFLEX FLEX FLOW ELBOW FOR
ADJUSTABLE RADIUS SUPPORT BRACE
CONNECTION TO ALL DIFFUSERS.
STRUCTURE
SUPPORT FROM STRUCTURESUPPORT FROM STRUCTURE
CONNECTION TO DIFFUSERDETAIL 'A'
NO SCALE
EGGCRATE RETURN GRILLE SCHEDULE
ACTUAL SIZE (MARK NO.)
24/6
48/24
24/24
24/12
24/6
24/48 901 - 1500
24/24
12/24
6/24
241 - 500
501 - 900
0 - 240
12/48 48"
12/24
8/24
6/24
24"
18"
12"
NOTES:
2.
1.
1" ACOUSTICAL DUCT LINER
CEILING
EGGCRATE RETURN GRILLE. SEEPLAN OR SCHEDULES FOR SIZES
INSIDE OF DUCT TO BE BLACK.
DUCT SUPPORTED FROM STRUCTURE,NOT CEILING GRID.
X
HANGERS
LISTED DUCT SIZEFROM BELOW FLAT BLACK.PAINT ALL FASTENERS VISIBLE
6"
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\M40
1 - D
ETAI
LS A
ND
SC
HED
ULE
S - M
ECH
ANIC
AL.d
wg,
5/1
/201
8 2:
44:3
3 PM
GENERAL NOTES: # - PLAN NOTES
NORTH
LOWER LEVEL PLAN - FIRE PROTECTION DEMOLITIONSCALE: 1/8" = 1'-0"
FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE, AND DESIGN.
ALL NEW WORK IS DRAWN DARK. ALL WORK DRAWN LIGHT AND FOLLOWED
CONTRACTOR SHALL FIELD VERIFY EXISTING PIPE AND EQUIPMENT SIZES,
FIRE PROTECTION SYSTEM WITH THE OWNER, OCCUPANTS OF THE AFFECTED AREA, CONTRACTOR SHALL COORDINATE SHUT DOWN AND DRAIN DOWN OF ANY
CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING
BY (E.) IS EXISTING.
AND ANY OTHER AUTHORITY HAVING JURISDICTION.
REMAIN OPERATIONAL.
BEGINNING WORK.
OPERATING AND APPEARANCE CONDITION.
LOCATIONS, ELEVATIONS, MATERIALS, ETC. BEFORE BIDDING OR
CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS
PROVIDE TEMPORARY CAPS AS REQUIRED SO EXISTING SYSTEMS WILL
CONSTRUCTION. ANY FACILITY DAMAGED OR DISCONNECTED BY22.
21.
20.
19.
18.
RESPONSIBILITY OF THIS CONTRACTOR WHETHER SHOWN ON THE DRAWINGS
A SUGGESTED METHOD FOR DESIGN. CONTRACTOR SHALL BE RESPONSIBLE
8. SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED, FULLYSUPERVISED, AND INSTALLED ACCORDING TO NFPA 13.
AND SPECIFICATIONS OR NOT.
ALL SPRINKLER SYSTEM ITEMS REQUIRED BY CODE SHALL BE THE
WHERE SPRINKLER HEADS ARE SHOWN ON THE DRAWINGS, LOCATIONS
PIPE ROUTINGS INDICATED ON DRAWINGS ARE DIAGRAMMATIC AND ARE
WITH OTHER DISCIPLINES, AND SHALL BE CONSIDERED FINAL.HAVE BEEN COORDINATED WITH ARCHITECT FOR AESTHETICS AND
11.
12.
10.
THESE NOTES APPLY TO ALL 'FP' SERIES DRAWINGS.1.
CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES.7.
UPDATE ALL FIRE PROTECTION SYSTEMS IN CONSTRUCTION AREA THATARE NON-COMPLIANT WITH CURRENT CODES.
13.
CONTRACTOR SHALL OBTAIN FLOW TEST DATA FROM UTILITY PRIORTO DESIGN AND HYDRAULIC CALCULATION OF SPRINKLER SYSTEM.
9.
PROVIDE UPRIGHT SPRINKLER HEADS IN UNFINISHED SPACES (I.E. THOSEWITH EXPOSED STRUCTURE), CONCEALED HEADS IN FINISHED SPACES (I.E.THOSE WITH LAY-IN FOR HARD CEILINGS), SIDEWALL HEADS WHEREIMPRACTICAL TO INSTALL CONCEALED OR UPRIGHT TYPE, OR AS INDICATEDOTHERWISE ON THE DRAWINGS.
REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATIONOF CEILING MOUNTED ITEMS.
ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE FP600 SERIESDRAWINGS FOR SCHEDULES.
SEE M001 SERIES DRAWINGS FOR SYMBOLS AND ABBREVIATIONS.
PROVIDE SLEEVES FOR ALL PIPING THAT PENETRATES FULL HEIGHTWALLS, WHETHER SHOWN OR NOT.
CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING ANDCUTTING HOLES THRU WALLS AND FLOORS AS REQUIRED TO INSTALLNEW PIPING, WHETHER SHOWN OR NOT.
ALL FLOOR PENETRATIONS TO BE FIRE STOPPED.
REMOVE ALL PIPING, VALVES, ETC. MADE OBSOLETE AS A RESULT OF NEWCONSTRUCTION.
THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOLITION WORK.ANY DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONALCOST TO OWNER.
DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL,STATE, AND FEDERAL REGULATIONS.
SIZE AND DESIGN SPRINKLER SYSTEMS FOR FUTURE EXPANSION WHEREINDICATED ON DRAWINGS.
FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO ATTEND ALL BUILDINGWALK-THROUGH'S (AFTER BUILDING IS OCCUPIED AND PRIOR TO THE ENDOF THE 1 YEAR WARRANTY PERIOD) BY THE BUILDING FIRE MARSHAL ANDIS RESPONSIBLE FOR MAKING ANY MODIFICATIONS TO THE SYSTEMREQUIRED AS A RESULT OF THIS BUILDING INSPECTION.
2.
3.
4.
5.
6.
14.
15.
16.
17.
23.
24.
25.
222
2 2 2
222
2 2
2 2
22
2 2
REMOVE SPRINKLER AND RUN-OUT PIPING BACKTO BRANCH PIPING.
SPRINKLER WORK THIS AREA ONLY.
1
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\FPD
201
- LO
WER
LEV
EL P
LAN
- FI
RE
PRO
TEC
TIO
N D
EMO
LITI
ON
.dw
g, 5
/1/2
018
2:43
:28
PM
- PLAN NOTES #
NORTH
LOWER LEVEL PLAN - FIRE PROTECTIONSCALE: 1/8" = 1'-0"
GENERAL NOTES:
FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE, AND DESIGN.
ALL NEW WORK IS DRAWN DARK. ALL WORK DRAWN LIGHT AND FOLLOWED
CONTRACTOR SHALL FIELD VERIFY EXISTING PIPE AND EQUIPMENT SIZES,
FIRE PROTECTION SYSTEM WITH THE OWNER, OCCUPANTS OF THE AFFECTED AREA, CONTRACTOR SHALL COORDINATE SHUT DOWN AND DRAIN DOWN OF ANY
CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING
BY (E.) IS EXISTING.
AND ANY OTHER AUTHORITY HAVING JURISDICTION.
REMAIN OPERATIONAL.
BEGINNING WORK.
OPERATING AND APPEARANCE CONDITION.
LOCATIONS, ELEVATIONS, MATERIALS, ETC. BEFORE BIDDING OR
CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS
PROVIDE TEMPORARY CAPS AS REQUIRED SO EXISTING SYSTEMS WILL
CONSTRUCTION. ANY FACILITY DAMAGED OR DISCONNECTED BY22.
21.
20.
19.
18.
RESPONSIBILITY OF THIS CONTRACTOR WHETHER SHOWN ON THE DRAWINGS
A SUGGESTED METHOD FOR DESIGN. CONTRACTOR SHALL BE RESPONSIBLE
8. SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED, FULLYSUPERVISED, AND INSTALLED ACCORDING TO NFPA 13.
AND SPECIFICATIONS OR NOT.
ALL SPRINKLER SYSTEM ITEMS REQUIRED BY CODE SHALL BE THE
WHERE SPRINKLER HEADS ARE SHOWN ON THE DRAWINGS, LOCATIONS
PIPE ROUTINGS INDICATED ON DRAWINGS ARE DIAGRAMMATIC AND ARE
WITH OTHER DISCIPLINES, AND SHALL BE CONSIDERED FINAL.HAVE BEEN COORDINATED WITH ARCHITECT FOR AESTHETICS AND
11.
12.
10.
THESE NOTES APPLY TO ALL 'FP' SERIES DRAWINGS.1.
CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES.7.
UPDATE ALL FIRE PROTECTION SYSTEMS IN CONSTRUCTION AREA THATARE NON-COMPLIANT WITH CURRENT CODES.
13.
CONTRACTOR SHALL OBTAIN FLOW TEST DATA FROM UTILITY PRIORTO DESIGN AND HYDRAULIC CALCULATION OF SPRINKLER SYSTEM.
9.
PROVIDE UPRIGHT SPRINKLER HEADS IN UNFINISHED SPACES (I.E. THOSEWITH EXPOSED STRUCTURE), CONCEALED HEADS IN FINISHED SPACES (I.E.THOSE WITH LAY-IN FOR HARD CEILINGS), SIDEWALL HEADS WHEREIMPRACTICAL TO INSTALL CONCEALED OR UPRIGHT TYPE, OR AS INDICATEDOTHERWISE ON THE DRAWINGS.
REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATIONOF CEILING MOUNTED ITEMS.
ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE FP600 SERIESDRAWINGS FOR SCHEDULES.
SEE M001 SERIES DRAWINGS FOR SYMBOLS AND ABBREVIATIONS.
PROVIDE SLEEVES FOR ALL PIPING THAT PENETRATES FULL HEIGHTWALLS, WHETHER SHOWN OR NOT.
CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING ANDCUTTING HOLES THRU WALLS AND FLOORS AS REQUIRED TO INSTALLNEW PIPING, WHETHER SHOWN OR NOT.
ALL FLOOR PENETRATIONS TO BE FIRE STOPPED.
REMOVE ALL PIPING, VALVES, ETC. MADE OBSOLETE AS A RESULT OF NEWCONSTRUCTION.
THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOLITION WORK.ANY DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONALCOST TO OWNER.
DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL,STATE, AND FEDERAL REGULATIONS.
SIZE AND DESIGN SPRINKLER SYSTEMS FOR FUTURE EXPANSION WHEREINDICATED ON DRAWINGS.
FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO ATTEND ALL BUILDINGWALK-THROUGH'S (AFTER BUILDING IS OCCUPIED AND PRIOR TO THE ENDOF THE 1 YEAR WARRANTY PERIOD) BY THE BUILDING FIRE MARSHAL ANDIS RESPONSIBLE FOR MAKING ANY MODIFICATIONS TO THE SYSTEMREQUIRED AS A RESULT OF THIS BUILDING INSPECTION.
2.
3.
4.
5.
6.
14.
15.
16.
17.
23.
24.
25.
CONCEALED STYLE PENDENT SPRINKLER HEAD. CONNECTRUN OUT PIPING TO EXISTING BRANCH PIPING.
SPRINKLER WORK THIS AREA ONLY.
2
1 11
1 11
1 11
1 11
1 11
1 11
1 11
1 11
1 1
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\FP2
01 -
LOW
ER L
EVEL
PLA
N -
FIR
E PR
OTE
CTI
ON
.dw
g, 5
/1/2
018
2:42
:58
PM
GENERAL NOTES (RENOVATION):
GENERAL NOTES (DEMOLITION):1. FIELD VERIFY ALL EXTG. CONDITIONS PRIOR TO BEGINNING WORK. THESE
DRAWINGS DO NOT SHOW ALL REQUIRED DEMOLITION WORK. SOME CONDITIONSMAY HAVE BEEN CONCEALED DURING FIELD SURVEYS.
2. ALL DEVICES AND EQUIPMENT SHOWN DASHED OR WITH HEAVY LINE WEIGHT SHALLBE REMOVED IN THEIR ENTIRETY, INCLUDING ALL WIRING TO SOURCE, UNLESSOTHERWISE NOTED.
3. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE &FEDERAL REGULATIONS.
4. CONTRACTORS SHALL PROTECT ALL EXTG. OWNER FACILITIES THAT ARE TO REMAINDURING CONSTRUCTION. ANY FACILITIES DAMAGED OR DISCONNECTED BYCONTRACTOR SHALL BE IMMEDIATELY RESTORED TO PREVIOUS CONDITION.
5. OWNER SHALL HAVE "RIGHT OF FIRST REFUSAL" FOR ALL DEMOLISHED ELECTRICALITEMS. CONTRACTOR SHALL COORDINATE WITH OWNER PRIOR TO BEGINNINGWORK TO DETERMINE WHAT ITEMS THE OWNER MAY BE INTERESTED IN KEEPING.
6. FOR MECH. EQUIPMENT BEING REMOVED, REMOVE ALL ASSOCIATEDDISCONNECTS, CONTROLLERS, WIRING, ETC. COMPLETE. VERIFY W/ M.C.
7. FOR EQUIPMENT OR DEVICES BEING REMOVED FROM WALLS THAT WILL REMAIN,PROVIDE A BLANK COVERPLATE (TO MATCH NEW) ON EXTG. BOX.
8. PROVIDE ADEQUATE SUPPORT FOR EXTG. CABLING/RACEWAYS ABOVE CEILING ASREQ'D. REMOVE ALL OBSOLETE CABLING, WIRING, RACEWAYS, ETC.
9. REMOVE ALL ASSOCIATED ELECTRICAL FOR ANY EXISTING EQUIPMENT BEINGREMOVED BY ANY TRADE. REFER TO ALL DRAWINGS.
10. CONTRACTOR SHALL REMOVE ALL EXTG. DEVICES ON WALLS BEING REMOVED,WHETHER DEVICES ARE SHOWN OR NOT, UNLESS OTHERWISE INSTRUCTED.
11. COORDINATE SCHEDULING OF DEMOLITION WORK WITH OWNER AND ALL TRADES.
12. PATCH ALL EXTG. HOLES THRU WALLS AND FLOORS WHERE EXTG. RACEWAYS ORCABLES ARE REMOVED.
13. IF SERVICE TO AN EXISTING DEVICE TO REMAIN IS INTERRUPTED BY THE REMOVAL OFANOTHER DEVICE, CONTRACTOR SHALL REWIRE THE EXISTING DEVICE THAT IS TOREMAIN AS REQUIRED TO MAINTAIN OPERATION.
VIDEO SURVEILLANCE CAMERA (WALL)
PASSIVE INFRARED DETECTOR
KEYPAD
DOOR CONTACT
SPRINKLER TAMPER SWITCH
SPRINKLER FLOW SWITCH
FIRE ALARM STROBE
HEAT DETECTOR
DUCT TYPE SMOKE DETECTOR
SMOKE DETECTOR
MAGNETIC DOOR HOLDER
FIRE ALARM BELL
FIRE ALARM HORN (SPEAKER)-STROBE
MANUAL PULL STATION
FIRE ALARM ANNUNCIATOR
FIRE ALARM CONTROL PANEL
LABORATORY EQUIPMENT COMPANY (CONTRACTOR)
EXISTING RELOCATED
EXISTING
EXPOSEDEXHAUST
EXISTING
EXISTING
EXTERIOR
EXCAVATIONEXIST
EXP
EXCAV
EXT
EXH
EXR
EXTG
EX
LV LOW VOLTAGE
EQUIPMENT GROUNDING CONDUCTOR
ENERGY MANAGEMENT SYSTEM
EXPLOSIONPROOF; ELECTRIC-PNEUMATIC
EXISTING TO REMAIN
ELECTRICAL METALLIC TUBING
EXTERIOR INSULATION FINISH SYSTEM
ELEVATOR; ELEVATIONELECTRICIAN; ELECTRICAL; ELECTRONIC
ELECTRIC BASEBOARD RADIATION
ELECTRICAL CONTRACTORELECTRONIC BALLAST
ELECTRIC WATER HEATERELECTRIC WATER COOLER
ENGINE; ENGINEERED
EMS
ENGINEER
ESTIMATED
ENCLOSURE
ENERGY SAVER
EQUIPMENTEP
ER
EMT
EQUIP
ENCL
ENGRENG
EWHEWCESTES
EMERGENCYEMERGENCY
EACH
EXHAUST FANEGC
EMERGEM
EBBR
EC
EA
EB
EF
ELEVELECTEIFS
DUSTPROOF; DOUBLE POLE
DUSTTIGHT; DOUBLE THROW
DOMESTIC HOT WATER
DIRECT DIGITAL CONTROL
DECIBEL; DIRECT BURIEDDEEP; DEPTH; DISCHARGE
DOUBLE POLE, SINGLE THROWDOUBLE POLE, DOUBLE THROW
EQUIPMENT ONLY; EAST; ELECTRICAL; EXISTING
DISC DISCONNECT
DOWN
DISHWASHER
DIRECT EXPANSIONDRAWING
DISTRIBUTIONDNDP
DTDW
DX
DPSTDPDT
DWG
DIST
E
DRINKING FOUNTAIN
DIRECT CURRENT
DIFFUSERDIAMETERDIAGONALDIAMETER
D
DFDHW
DDCDCDB
DIAMDIAG
DIFF
DIA
LOCKED ROTOR AMPS
KILOVOLT AMPERE REACTIVE
LABOR; LABORATORY
KILOVOLT AMPERE
LAMP LUMEN DEPRECIATIONLONG; LENGTH; LARGE
LIGHT EMITTING DIODE
POUND; ELL CONDUIT BODY
LIGHT; LIQUID-TIGHT
LOW POWER FACTOR
LED
LRA
LGLF
LM
LPLO
LTR
LLD
LTGLT
LPF
LINEAR FOOT
LUMENLOCKOUT
LETTERLIGHTING
LIGHTING PANEL
KWH
KVAKVKP
KVAR
LABL
KWKW
LECLB
KILOWATT-HOUR
KILOVOLTKEYPAD
LENGTH; LONG
KILOWATT
INCLUDED; INCLUDING
ISOLATED GROUND
THOUSAND CIRCULAR MILS
INVERT ELEVATIONINTERIOR; INTERNAL
JOULE; JUNCTION
INSULATION; INSULATED
KITCHEN EQUIPMENT CONTRACTOR
INTERMEDIATE METAL CONDUIT
INV EL
J-BOXJB
KK
IS
KEC
K
J
KCMIL
KHZ
JUNCTION BOXJUNCTION BOX
KIRK KEY
THOUSAND
INSTANT START
KILOHERTZ
IMP
IFIG
INSTINCL
ININCAND
IMC
INTINSUL
ENGINEERS
IMPEDANCEINCH
INSTALLATION
INCANDESCENT
INSIDE FROSTED
RIGID STEEL CONDUITRTRSCRS
RAINTIGHT
RAPID START
RIGID NON-METALLIC CONDUIT
RUNNING LOAD AMPS
RECIRCULATING
RELAY CONTROL STATION
REFERENCE; REFRIGERATED
REVOLUTIONS PER MINUTE
ROOT MEAN SQUARE
RIGID GALVANIZED STEEL
POLYVINYL CHLORIDE
RESISTANCE; RELOCATED; RECESSED
REMOVE & REPLACE
REQ'D REQUIRED
RNC
RLARMS
RGSRFRET
RPMRRR&R
RP
RETURN FANRETURN
RESTROOM
RAINPROOF
PU
RECEPT
QUAN
PWRPVC
RCS
REFRECIRC
R
PER UNIT
RECEPTACLE
POWER
QUANTITY
PROTECTIVE DEVICE
PUBLIC ADDRESS
POWER FACTOR CORRECTION CAPACITORPOWER FACTOR
PUSHBUTTON; PULL BOX
POST INDICATOR VALVE
POUNDS PER SQUARE INCH GAUGEPOTENTIAL TRANSFORMER
POUNDS PER SQUARE INCHPOUNDS PER SQUARE FOOT
PROFESSIONAL ENGINEER
POWER CONNECTOR; PHOTOCELL
OUTSIDE SCREW AND YOKE
PH PHASE
PL
PNL
PIV
PR
PLBG
PKG
PTPSIGPSIPSFPRI
PILOT LIGHT
PANELBOARDPLUMBING
PACKAGE
PAIRPRIMARY
PD
PA
PFPFCC
P
PCPB
PE
OZOS&Y
POLE; PULL
OUNCE
PHASE; DIAMETER
APPROXIMATELY
POUND; NUMBER
'"
°
O
~@%#
FEETINCHES
DELTADEGREE
ATPERCENT
VAPORTIGHT
VERY HIGH OUTPUTVERY HIGH FREQUENCYVARIABLE FREQUENCY DRIVE
"WIREMOLD" (SURFACE RACEWAY)WIRE GUARD
WELDER OUTLETWEATHERPROOFWEIGHT: WATERTIGHT
TRANSFORMER
WELDED WIRE FABRIC
EXTRA HEAVY DUTY
WIRE; WATT; WIDE; WEST; WASTE
WELL WATER; WARM WHITE
WO
WWF
WPWT
Y
XHD
WW
XFERXFMR
WYE
TRANSFER
VT
VHOVHFVFDVERT
WGW/W
VOL
WM
VERTICAL
VOLUME
WITHFOODSERVICE FACILITIES EQUIPMENT CONTRACTOR
CABINET UNIT HEATER
CONTROL POWER TRANSFORMER
CENTRAL OFFICE GROUND BAR
CONCRETE MASONRY UNITCONSTRUCTION MANAGER
CENTRAL STATION AIR CONDITIONER
COOL WHITE; COLD WATER; CLOTHES WASHER
CURRENT TRANSFORMER
CONDENSATE; CONDUCTORCONTINUOUS; CONTINUED; CONTRACTORCONTCONTROL PANEL
CYLINDER
CUBIC FOOT
CUBIC YARD
COPPER; CUBIC
CUH
CPCPT
CU FT
CSAC
CUCT
CYLCYCW
COLUMNCOMBINATION
CENTRAL OFFICE
COOLING; CEILING
CONCRETECOMPRESSOR
CMCLG
COMB
COGBCO
COL
CMU
COMPR
CONDCONC
BOLTED PRESSURE SWITCH
CONDUIT; CENTIGRADE
BELOW FINISHED GRADE
CLOSED CIRCUIT TELEVISION
CURRENT LIMITING FUSE
CHILLED WATER PUMP
CUBIC FEET; COMPACT FLUORESCENTCANDELA; CLOTHES DRYER
CENTER TO CENTERCABINETCAB
CIRCUIT
CAPACITY
CIRCUIT
CAST IN PLACE
CHILLED WATER
CIRCUIT BREAKER
CIR
CCTVCBCAP
CHWPCHW
CIP
CFCD
CLFCKT
BRANCHBREAKER
BATTERYBOARD
BUILDING
BRBRKR
BPS
BATT
BLDG
C
BFGBD
C/C
INSTITUTE OF ELECTRICAL & ELECTRONICSINTERMEDIATE DISTRIBUTION FRAME
HIGH PRESSURE SODIUM
HOURS PER DAY
HIGH POWER FACTOR
HAND-OFF-AUTOMATIC
HOT WATER; HEAVY WALLHEATING WATER PUMP
HIGH SHORT CIRCUIT
INTERRUPTING CAPACITY
HEATING, VENTILATION & AIR-CONDITIONING
HORSEPOWER; HIGH PRESSURE
HEATERSHTRS
IEEE
HV
IDF
HW
HZHYDHWP
HVAC
IDIC
HIGHT VOLTAGE
HERTZHYDRAULIC
INSIDE DIAMETER
HOHOAHORIZ
HPSHR
HPFHP
HTHTG
HSCHRS/DAY
HORIZONTAL
HIGH OUTPUT
HOUR
HEIGHTHEATING
GROUND FAULT PROTECTOR
GROUND FAULT CIRCUIT INTERRUPTER
GENERAL PURPOSE
GALVANIZED RIGID CONDUIT
HEATING, AIR CONDITIONING & REFRIGERATION
GENERAL CONTRACTOR
GROUND; GROUNDEDGALVANIZED RIGID STEEL
GALLONS PER MINUTE
GENERAL; GENERATOR
GROUND FAULT INTERRUPTER
HIGH INTERRUPTING CAPACITY
GP
GRC
HACR
HH
GRD
GPM
H
HD
GRS
HIC
HGHAND HOLE
HIGH
HEAVY DUTYMERCURY
GFP
GFCI
GCGALV
GFI
GND
GEN
GALGAG
GALVANIZED
GROUND
GALLON
GROUNDGAUGE
AMPEREA
AMERICAN NATIONAL STANDARDS INSTITUTE
AMPERE FUSE; AMPERE FRAME
AUTOMATIC TRANSFER SWITCH
ABOVE FINISHED FLOOR
ALTERNATING CURRENT; ARMORED CABLE
AMPERE INTERRUPTING CAPACITY
AMERICAN WIRE GAUGE
ABOVE FINISHED GRADE
AMPERE TRIPASYMMETRICAL
AUXILIARY
AMPERE
ARCHITECT
AVERAGE
APPROXIMATEACCESS PANEL
ANSI
ASYMATATSAUX
APPROXAP
AMP
ARCH
AWGAVG
ADJUSTABLE
AIR-CONDITIONING
ALUMINUM
ALUMINUMALTERNATE
AIR HANDLING UNIT
AF
A/C
AFF
ADJAC
ALTALAICAHUAFG
ALUM
F FUSED; FAHRENHEIT
FIRE ALARM CONTROL PANELFIRE ALARM ANNUNCIATOR PANEL
FITTING; FOOTING
FULL LOAD AMPS
FULL VOLTAGE NON-REVERSING
FLUORINATED ETHYLENE PROPYLENE
FEET PER MINUTE
FUSED DISCONNECT
FREQUENCY MODULATION; FACTORY MUTUAL
FTG
FLAFIXT
FPMFM
FLRFLUOR
FVNRFURN
FTFR
FIXTURE
FLOOR
FURNISHED
FOOT; FEETFIRE RATING
FLUORESCENT
FACPFAAP
FCU
FDR
FFEC
FC
FA
FIGFIN
FEP
FDFAN COIL UNIT
FEEDER
FOOT-CANDLE
FIRE ALARM
FIGUREFINISHED
MANUFACTURINGMFG
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
MERCURY VAPOR, MEGAVOLT; MEDIUM VOLTAGE
NON-AUTOMATIC
NATIONAL ELECTRICAL CODE
NOT TO SCALE
NORMALLY CLOSED
ON CENTER; OVERCURRENTOVERHEAD AND PROFIT
NUMBER; NORMALLY OPENNON-METALLIC SHEATHED CABLE
NON-FUSED DISCONNECTNOT IN CONTRACT
OUTSIDE DIAMETER
OVERHEAD DOOR
OFFICE PRINCIPAL GROUND POINT
OVERHEAD DISTRIBUTION SYSTEM
NOT AVAILABLE; NOT APPLICABLE
NM
NTS
OC
OL
O&P
NO
OHODSOD
OHD
OPGPOVERLOAD
OVERHEAD
NA
NECNEMA
ND
NL
NC
N/A
NAT
NFDNIC
NF
NORMAL DUTY
NIGHT LIGHT
NATURAL
NON-FUSED
MAIN LUG ONLY
MANUAL TRANSFER SWITCH
MAXIMUM OVERCURRENT PROTECTION
MANUFACTURER
MISCELLANEOUSMINIMUM; MINUTE
NORTH; NEW; NEUTRAL
MEGAVOLT AMPERES
MULTI; MULTIPLY
MANHOLE; METAL HALIDE; MAN-HOUR
MEGAVOLT AMPERES REACTIVE
MALLEABLE IRON; MINERAL INSULATED
MOCP
MTGMTS
MTDMOG
MW
MVAMV
MVAR
N
MULT
MOUNTING
MOGULMOUNTED
MEGAWATT
MIC
MLO
MHMFR
MISCMIN
MIMHZ
MOBILMO
MICROPHONE
MEGAHERTZ
MOBILIZATIONMONTH
TELEPHONE TERMINAL BOARD
TRANSIENT VOLTAGE SURGE SUPPRESSOR
UNDER (CABINET OR COUNTER)
UNDERGROUND
UNLESS OTHERWISE INDICATED
UNDERVOLTAGE RELAY (RELEASE)
TRIGGER START
UNIT HEATER
VOLT AMPERES
VIDEO DISPLAY TERMINALVARIABLE AIR VOLUME
VOLT; VENTILATION
UNSHIELDED TWISTED PAIR
UNDERWRITERS LABORATORYULTRA HIGH FREQUENCY
UNDERGROUND FEEDER
VOLT-AMPERES REACTIVE
UL
UOIUTIL
UVR
UNFIN
V
UTP
VDTVAVVARVA
UTILITY
UNFINISHED
TTB
TVSS
UC
UGUF
TYP
TV
TS
UHFUH
TYPICAL
TELEVISION
SOLENOID VALVE
SWITCHING DUTY
SYMMETRICAL
TIME CLOCKTERMINAL BLOCK
TIME DELAY
TOTAL HARMONIC DISTORTION: THREAD
TOP OF FINISHED FLOOR
TAMPER RESISTANT
SQUARE YARDSWITCHBOARD
TRANSFORMER
TEMPERATURE CONTROL CONTRACTOR
TETRAFLUOROETHYLENE
TEMPERATURE; TRANSFORMER
SUBCONTRACTORS
TTBTC
TD
THD
TELE
TFF
TR
TFMR
TFE
TH
TCC
TELEPHONE
THICK
SV
SWD
SYM
SWBRD
SW
SURFSUBS
SYSSYN
SY
SYNTHETICSYSTEM
SWITCH
SURFACE
METAL CLAD CABLE; MECHANICAL CONTRACTOR;
M THOUSAND; MATERIAL; MECHANICAL; METER
MOTOR CONTROLLER
MASTER ANTENNA TELEVISION
MOLDED CASE CIRCUIT BREAKERMOTOR CONTROL CENTERMAIN CIRCUIT BREAKER
MOTOR CIRCUIT SWITCHMAIN DISTRIBUTION FRAMEMAIN DISTRIBUTION PANELBOARD
MINIMUM CIRCUIT AMPS
MAGNETIC STARTER
MOTOR CIRCUIT PROTECTORTHOUSAND CIRCULAR MILS
MCAMCB
MCCBMCC
MDPMDFMCSMCPMCM
MEDMECH MECHANICAL
MEDIUM
MAN
MATV
MA
MAG STRMAINT
MACH
MCMAX
MATMANUALMAINTENANCE
MACHINEMILLIAMPERE
MAXIMUM
MATERIAL
S SOUTH
SERVICE RACEWAY; SURFACE RACEWAY
SLIM LINE; SERVICE LATERALSOLID NEUTRAL
SECONDARYSUPPLY FAN; SQUARE FOOT
SERVICE DROPSHORT CIRCUIT RATING
SQUARE INCHSQUARE FOOT
START/STOPSTEEL: SHUNT TRIP; SINGLE THROW
SINGLE POLE
STAINLESS STEEL; SAFETY SWITCH
SINGLE POLE, SINGLE THROW
SINGLE POLE, DOUBLE THROW
SERVICE ENTRANCE; SERVICE EQUIPMENT
STRUCTURAL
SPKR SPEAKER
STRUCT
SQ
SR
SPST
SQ INSQ FT
STRSTD
SSS/SST
SQUARE
STARTERSTANDARD
SDSCRSCHED
SLSN
SFSECSE
SPDT
SP
SCHEDULE
SWITCH, THREE WAY
SWITCH LEG
SWITCH, DIMMER
SWITCH, WEATHERPROOF
SWITCH, WITH PILOT LIGHT
SWITCH, KEY OPERATED
SWITCH, FOUR WAY
3-WAY
SWITCH LEG
1
a 1
'F1'
SURFACE RACEWAY ("WIREMOLD")
UNDERFLOOR DUCT & JUNCTION BOX, DUAL SYSTEM
UNDERFLOOR DUCT & JUNCTION BOX, TRIPLE SYSTEM
UNDERFLOOR DUCT & JUNCTION BOX, SINGLE SYSTEM
CONDUIT, CAPPED
CONDUIT, TURNING DOWN
CONDUIT, TURNING UP
CONDUIT, EXPOSED
CONDUIT, BELOW FLOOR
CONDUIT, IN WALL OR CEILING
PANEL, FLUSH
DUPLEX RECEPTACLEGROUND FAULT CIRCUIT INTERRUPTER/WEATHERPROOF ROOF
GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE
ISOLATED GROUND DUPLEX RECEPTACLE
DOUBLE DUPLEX (QUAD) RECEPTACLE
SINGLE RECEPTACLE
SWITCH, DOUBLE POLE
SWITCH, SINGLE POLE
SPECIAL OUTLET OR EQUIPMENT CONNECTION (AS NOTED)
FLOOR OUTLET
DUPLEX RECEPTACLE
PULL BOX
JUNCTION BOX
LIGHT FIXTURE TYPE
DOUBLE DUPLEX (QUAD) GROUND FAULT CIRCUITINTERRUPTER RECEPTACLE
CIRCUIT NUMBER
CIRCUIT NUMBER
MULTI-TECHNOLOGY CEILING OCCUPANCY SENSING
LIGHT, CEILING
LIGHT, CEILING
LIGHT, WALL
EXIT LIGHT, CEILING
EXIT LIGHT, WALL
EXIT LIGHT WITH DIRECTIONAL ARROW, CEILING
EXIT LIGHT WITH DIRECTIONAL ARROW, WALL
EMERGENCY LIGHTING UNIT
TRACK LIGHT FIXTURE
NIGHT LIGHT WITH 'NL' SUBSCRIPT
EMERGENCY LIGHT
ULTRASONIC CEILING OCCUPANCY SENSING
PASSIVE INFRARED CEILING OCCUPANCY SENSING
SINGLE POLE WALL OCCUPANCY SENSOR
TWO POLE WALL OCCUPANCY SENSOR
PANEL, SURFACE
CONTROL PANEL (AS NOTED), FLUSH
CONTROL PANEL (AS NOTED), SURFACE
SURGE PROTECTIVE DEVICESPD
SCCR SHORT-CIRCUIT CURRENT-RATING
A1 A1-1
CIRCUIT NUMBER
PANEL NAME
PANEL NAME
* INDIVIDUAL CIRCUITS NUMBERSARE LOCATED AT EACHDEVICE
NEUTRAL CONDUCTOR
PHASE (OR CONTROL) CONDUCTOR
GROUND CONDUCTOR
ISOLATED GROUND CONDUCTOR
INDICATES MINIMUM WIRE SIZE PER SPECIFICATIONS
S1
S2
OS
PI
US
ISOLATED GROUND DOUBLE DUPLEX (QUAD) RECEPTACLE
WP
J
P
FACP
FAA
F
F
F
F
DH
F
D
H
FS
TS
VCC VOICE COMMAND CENTER
DC
KP
PIR
C
VIDEO SURVEILLANCE CAMERA (CEILING)C
INTERCOM CALL SWITCH
WALL MOUNTED SPEAKER (ROUND)
BUZZER
WALL MOUNTED SPEAKER (SQUARE)
CEILING MOUNTED SPEAKER (ROUND)
MICROPHONE OUTLET
SPEAKER VOLUME CONTROL
BELL
CEILING MOUNTED SPEAKER (SQUARE)
HORN-PAGING
S
S
V
M
P
S
S
CLOCK (WALL)
CLOCK (CEILING)
PUSHBUTTON
UP/DOWN PUSHBUTTON
UP/DOWN/STOP PUSHBUTTON
1-PHASE MOTOR
3-PHASE MOTOR
DISCONNECT
MANUAL MOTOR STARTER
MANUAL MOTOR STARTER WITH PILOT SWITCH
MAGNETIC MOTOR STARTER
COMBINATION DISCONNECT & MAGNETIC MOTOR STARTER
P
SMALL TRANSFORMER
TIMECLOCK
PHOTOCELL
TC
PC
R
LC
RELAY PANEL
LIGHTING CONTACTOR
HORN
ELECTRICAL GROUND
DROP CORD (AS NOTED)
POWER POLE
F FIRE ALARM STROBE (CEILING MOUNTED)
EMERGENCY VOICE-ALARM LOUDSPEAKERA
CARD READERCR
ELECTRIC LATCHEL
POWER SUPPLYPS
CONTROL PANELCP
SWITCH, SPRING WOUND, INTERVAL TIME SWITCH
1. COORDINATE LOCATIONS OF ALL DEVICES TO BE INSTALLED IN CEILINGS (LIGHTS,SPEAKERS, DETECTORS, ETC.) WITH THE ARCHITECTURALREFLECTED CEILING PLANS.
2. NOTIFY ENGINEER OF ANY CONFLICTS PRIOR TO INSTALLATION.
3. ALL 120 VOLT CIRCUITS SHALL UTILIZE SEPARATE INDEPENDENT NEUTRAL CONDUCTORS.DO NOT SHARE NEUTRALS.
4. CONTRACTOR SHALL COORDINATE WITH ALL TRADES. NO ADDITIONALCOMPENSATION WILL BE ALLOWED FOR INCORRECT WORK, OR FOR INFRINGEMENTUPON OTHERS WORK, DUE TO A LACK OF COORDINATION.
5. DEVICES IN GENERAL SHALL BE CENTERED IN WALL SPACE IN WHICH THEY AREINSTALLED OR THEY SHALL BE SPACED SYMMETRICALLY (FOR EXAMPLE, CENTERDEVICES WHEN MOUNTED ON FACE OF COLUMNS).
6. COORDINATE & VERIFY LOCATIONS OF DEVICES W/ BLOCK COURSING, FINISHMATERIALS, CASEWORK, ETC. PRIOR TO ROUGH-IN.
7. WIRING TO ALL RECEPTACLES ON DEDICATED CIRCUITS SHALL BE #10 MINIMUMUNLESS OTHERWISE NOTED.
8. ALL WIRING SHALL BE MINIMUM #12 AWG. IN 3/4" CONDUIT UNLESS OTHERWISE NOTEDOR REQUIRED.
9. COORDINATE LOCATION OF RECEPTACLES AT ELECTRIC WATER COOLERS (EWC) W/EWC MANUFACTURER. PROVIDE DUPLEX GFCI RECEPTACLE SO THAT IT IS CONCEALEDBY EWC HOUSING.
10. COORDINATE EXACT LOCATION OF ALL DEVICES, AND DEVICE/COVER COLORS, WITHARCHITECT PRIOR TO ROUGH-IN.
11. PROVIDE ACCESS PANELS AS REQUIRED TO SERVICE PULL/JUNCTION BOXESCONCEALED IN WALLS OR CEILINGS. COORDINATE LOCATIONS WITHARCHITECT/ENGINEER.
12. PROVIDE EXTENSION RING ON EXISTING DEVICE BOXES TO ACCOMODATE NEW WALLFINISHES AS REQUIRED.
VOICE/DATA/COAX (RF) OUTLET (ONE CAT. 6A VOICE/ONE CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)
VOICE/DATA OUTLET (ONE CAT. 6A VOICE/ONE CAT. 6A DATA - JACKS AND CABLES)
SINGLE OR SPECIAL OUTLET AS INDICATED (V=CAT. 6A VOICE; D=CAT. 6A DATA; C=RG-6 COAX), EXAMPLE:
WALL PHONE OUTLET (ONE CAT. 6A VOICE - JACK AND CABLE)W
D =ONE CAT. 6A DATA - JACK AND CABLE
VOICE/DATA/DATA/COAX (RF) OUTLET (ONE CAT. 6A VOICE/TWO CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)2D
WIRELESS ACCESS CONNECTION POINT (TWO CAT. 6A DATA - JACKS AND CABLES) - PROVIDE 10'-0" SERVICE LOOP AND RED RJ45 JACKS ABOVE CEILING. AP
NOTE: COLOR OF DATA JACKS SHALL MATCH WIRING DEVICES, AP JACKS SHALL BE RED AND PHONE JACKS SHALL BE BLUE, UNLESS OTHERWISE DIRECTED.
EMERGENCY WALL PHONE OUTLET (ONE CAT. 6A VOICE - JACK AND CABLE)911
DATA/DATA/COAX (RF) OUTLET (TWO CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)D
TELEVISION OUTLET (ONE CAT. 6A DATA/ONE RG-6 COAX - JACK AND CABLE) - VERIFY EXACT OUTLET (& DUPLEX RECEPT.) LOCATION WITH OWNER.TV
EMERGENCY NOTIFICATION SYSTEM WALL OUTLET (ONE CAT. 6A DATA - JACK AND CABLE)ENS
CIRCUIT NUMBER:
PANEL - CIRCUIT NUMBER(I.E. A1-1)
MULTIPLE INDIVIDUAL CIRCUIT NUMBERS:
PANEL - CIRCUIT NUMBER, CIRCUIT NUMBER, CIRCUIT NUMBER(I.E. A1-1,3,5)
2-POLE CIRCUIT NUMBER
PANEL - CIRCUIT NUMBER/CIRCUIT NUMBER(I.E. A1-1/3)
3-POLE CIRCUIT NUMBER
PANEL - CIRCUIT NUMBER/CIRCUIT NUMBER/CIRCUIT NUMBER(I.E. A1-1/3/5)
PROJECTOR (SEE A/V SPECS)PR
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\E00
1 - S
YMBO
LS, A
BBR
EVIA
TIO
NS,
AN
D G
ENER
AL N
OTE
S - E
LEC
TRIC
AL.d
wg,
5/1/
2018
2:4
0:26
PM
NORTH
LOWER LEVEL PLAN - ELECTRICAL DEMOLITIONSCALE: 1/8" = 1'-0"
F
AP
8. REMOVE POWER POLE AND ALL ASSOCIATED WIRING.
9. FIRE ALARM STROBE SHALL REMAIN.
10. CLOCK TO REMAIN.
11. ABANDONED DEVICE BOX. REMOVE WIRING TO SOURCE.
12. REMOVE RECEPTACLE AND WIRING ABOVE CEILING TO PROJECTOR.REMOVE PROJECTOR AND ALL ASSOCIATED WIRING. TURN PROJECTOROVER TO OWNER.
13. REMOVE EMERGENCY LIGHT AND WIRING.
14. REMOVE FIRE ALARM SMOKE DETECTOR AND MODIFY WIRING ASREQUIRED TO MAINTAIN SERVICE TO OTHER DEVICES THAT ARE TOREMAIN. SEE T201 FOR NEW DEVICES.
15. WIRELESS ACCESS POINT TO BE REMOVED. REMOVE ALL ASSOCIATEDCABLING BACK TO SOURCE. TURN ACCESS POINT OVER TO OWNER.
16. EXISTING EMERGENCY NOTIFICATION PHONE TO REMAIN.
GENERAL NOTES1. SEE DRAWING E001.
S
F
SS S
F
AP
PR
PR
F
F
8
8
8
8
8
2
3
221
8
8
8
8
8
32
ENS
2
2
F
2
3
22
3
2
2
2
J
6
PLAN NOTES#
1. REMOVE LIGHTING AND MAKE 277V CIRCUIT SAFE FOR REUSE. SEEDRAWING E201. 277V CIRCUIT FROM PANEL 'HBB' SERVES 2X4 LIGHTS.REMOVE 120V CIRCUIT FROM PANEL 'LBB-2' THAT SERVES DOWNLIGHTS.
2. RECEPTACLES AND TECHNOLOGY DEVICES SHALL REMAIN UNLESSOTHERWISE NOTED.
3. REMOVE LIGHT SWITCHES AND DIMMER.
4. MAKE SAFE EMERGENCY LIGHTING CIRCUIT FOR RE-USE. SEE DRAWINGE201.
5. EXISTING PANEL TO REMAIN.
6. REMOVE ALL LIGHTS, RECEPTACLES, TECHNOLOGY OUTLETS, WIRING, ETCIN THEIR ENTIRETY, UNLESS OTHERWISE NOTED.
7. REMOVE TWO-COMPARTMENT SURFACE RACEWAY AND ALLASSOCIATED WIRING.
(277/480V) 'HBA'
(120/208V) 'LBA-1'
(120/208V) 'LBA-2'
5
5
5
5
14
10
10
9
11
9
COMPUTER ROOMPANEL (120/208V)
14
8
6
6
13 14
14
(TYP.)
5UNNAMED PANEL(120/208V)
12
13
7 (TYP.)
1313 12
15
15
DEMOLITION LEGENDWORK TO BE REMOVED.
WORK TO REMAIN.
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\ED
201
- LO
WER
LEV
EL P
LAN
- EL
ECTR
ICAL
DEM
OLI
TIO
N.d
wg,
5/1
/201
8 2:
42:3
2 PM
PLAN NOTES#
1. PROVIDE 0-10V WALL BOX DIMMERS, LIKE LEVITON RENOIR II SERIES.VERIFY COMPATIBILITY WITH LIGHT FIXTURES. MULTI-LOCATION ASNECESSARY.
2. INSTALL LIGHTS IN EXISTING CEILING. CONNECT LIGHTS TO EXISTING 277VOLT CIRCUIT FROM EXISTING PANEL 'HBB'.
3. INSTALL LIGHTS IN EXISTING CEILING. CONNECT LIGHTS TO EXISTING 277VOLT CIRCUIT FROM EXISTING PANEL 'HBB' AND EXISTING EMERGENCYLIGHTING CIRCUIT. FIXTURE TO CONTAIN (2) GENERATOR TRANSFERDEVICES.
4. CONNECT LIGHTS TO EXISTING LIGHTING CIRCUIT. VERIFY SOURCE ANDVOLTAGE IN FIELD.
5. EXISTING PANEL
GENERAL NOTES
NORTH
LOWER LEVEL PLAN - LIGHTINGSCALE: 1/8" = 1'-0"
1. SEE DRAWING E001.
D cD b
D aD c
D bD a
F1 b F1 a F1 a
F1 b F1 a F1 a
F1 b F1 a
F1 b F1 a F1 a
F1 b F1 a F1 a
F1 b F1 a
F1 b F1 a F1 a
F1 b F1 a F1 a
F1 a F1 a F1 a
F1 b F1 b F1 b
D bD a
F2
c
F2
c
F2
c
F2
c
F2
c
F2
c
1
1
1
(277/480V) 'HBA'
(120/208V) 'LBA-1'
(120/208V) 'LBA-2'COMPUTER ROOMPANEL (120/208V)
UNNAMED PANEL(120/208V)
4
F1E
a
4
4
F1E a
3
3
D b
1
D cD b1
D c
MARK FIXTUREMOUNTING VOLTAGE MANUFACTURER(S)
'F1' IN GRID
DESCRIPTION
LED UNIVERSAL FINELITE HPR-LED-A-2X4-DCO-H-835 SERIES2-FOOT BY 4-FOOT ARCHITECTURAL TROFFER, ANGLED DOOR,DIFFUSE CENTER OPTIC, 0-10V DIMMING, HIGH OUTPUT, NOMINAL 41WATTS, MINIMUM 5416 LUMENS, UNIVERSAL VOLTAGE.
RECESSED
LAMP
41
LOAD (VA) TEMP.TYPE LUMENS
3500K 5416
'F1E' SAME AS F1, PLUS (2) GENERATOR TRANSFER DEVICES.
'F2' IN GRID LED UNIVERSAL FINELITE HPW-LED-4'-FR-H-835 SERIES4' LINEAR ASYMMETRIC LED WALL WASH, FROSTED LENS, HIGHOUTPUT, NOMINAL 28 WATTS, MINIMUM 3038 LUMENS, UNIVERSALVOLTAGE.
RECESSED 28 3500K
(MIN.)
3038(MIN.)
RENOVATION LEGENDWORK TO BE INSTALLED
EXISTING WORK TO REMAIN.
5
5
5
5
5
OS
OS
OS
OS
OS
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\E20
1 - L
OW
ER L
EVEL
PLA
N -
LIG
HTI
NG
.dw
g, 5
/1/2
018
2:41
:06
PM
NORTH
LOWER LEVEL PLAN - POWERSCALE: 1/8" = 1'-0"
PLAN NOTES#
1. PROVIDE 120V CIRCUIT AND CONTROL WIRING TO MOTORIZEDPROJECTION SCREEN.
2. COORDINATE DEVICE LOCATION WITH TV.
3. PROVIDE 120V CIRCUIT AND DUPLEX RECEPTACLE AT PROJECTOR.
4. ALL RECEPTACLE CIRCUITS IN THIS ROOM SHALL BE FED FROM EXISTINGCOMPUTER ROOM PANEL.
5. ALL RECEPTACLE CIRCUITS IN THIS ROOM SHALL BE FED FROM EXISTINGUNNAMED PANEL.
6. EXISTING PANEL.
7. EXISTING DEVICES TO REMAIN UNLESS OTHERWISE NOTED.
GENERAL NOTES1. SEE DRAWING E001.
2. COORDINATE DEVICE LOCATIONS WITH MARKERBOARDS, ETC.
RENOVATION LEGENDWORK TO BE INSTALLED
EXISTING WORK TO REMAIN.
(277/480V) 'HBA'
(120/208V) 'LBA-1'
(120/208V) 'LBA-2'COMPUTER ROOMPANEL (120/208V)
UNNAMED PANEL(120/208V)
9
99
59
1111 11+60"TV2
2
2
468
182022
26
25
4
5
PR25
25PR
3
3
6
10
131517
18
16
PR16
16PR
3
3
1214
6
6
TEACHERPODIUM
TEACHERPODIUM
6
6
6
6
6
11
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\E21
1 - L
OW
ER L
EVEL
PLA
N -
POW
ER.d
wg,
5/1
/201
8 2:
41:4
1 PM
TYPICAL RECESSED FLUORESCENT LIGHTING INSTALLATION
CONDUIT CLAMP AND HANGER
BETWEEN HANGERS (TYP.)HANGER & 8' MAX. SPACING- 3' MAX. FROM BOX TO
6' MAX. LENGTH FLEX CONDUIT
DO NOT SUPPORT
GRID HANGERS
CONDUIT OR BOXFROM CEILING
W/ 3-#12 CONDUCTORS INTO
TYPICAL 2'x4' LAY-IN
PROVIDE CHAIN HANGERS TO
SUSPENSION SYSTEM (TYP.)
TWO PER FIXTURE (TYP.)
T-BAR LAY-IN CEILING
GRID WITH CLIPS PERSECURE FIXTURES TO
RECESSED FLUORESCENTLIGHT FIXTURE (TYP.)
STRUCTURE FOR FIXTURE SUPPORT,
N.E.C. (TYP.)
NOTES:
FIXTURE (TYP.)
STEEL OUTLET BOX -SIZED PER N.E.C. ANDSUPPORTED RIGIDLYFROM STRUCTURE (TYP.)
CONDUIT (TYP.)
18" AFF OR MATCH ADJACENT DEVICE,
BOX RECESSSED IN WALL WITH 1"
UNLESS OTHERWISE NOTED.
4-11/16" SQ. X 2-1/2" DEEP 2-GANG
EXTENSION RING, FLUSH W/ FINISHED WALL.
TECHNOLOGY OUTLET ROUGH-IN DETAIL
PROVIDE ONLY (1) 3/4"C.FOR WALL PHONE.
(NOTE:
IN WALL TO 6" ABOVE CEILING,(2) 1" CONDUITS CONCEALED
WITH PULL STRING.
LONG SWEEPELBOWS
WHEN PULLING CABLES, FILL ONE CONDUITFIRST BEFORE USING OTHER CONDUIT.
FLOOR
LC
ACCESSIBLE CEILING
WALL MINIMUM OF 6" W/ ELBOWS.(EXTEND TO ABOVE ACCESSIBLE CEILING).
PLASTIC BUSHING (TYP.)EXTEND CONDUITS OUT OF
NOTE:
VERIFY WITH WALL CONSTRUCTION.
NO SCALE
NO SCALE
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\E40
1 - D
ETAI
LS -
ELEC
TRIC
AL.d
wg,
5/1
/201
8 2:
42:0
7 PM
NORTH
LOWER LEVEL PLAN - TECHNOLOGYSCALE: 1/8" = 1'-0"
PLAN NOTES#
1. COORDINATE DEVICE LOCATION WITH TV.
2. PROVIDE DATA CABLE TO PROJECTOR, PLUS OTHER CABLINGAS INDICATED ON DRAWING T401.
3. EXISTING DEVICES TO REMAIN UNLESS OTHERWISE NOTED.
4. EXISTING FIRE ALARM STROBE TO REMAIN.
5. PROVIDE FIRE ALARM STROBE TO MATCH EXISTING ANDCONNECT TO EXISTING INDICATING CIRCUIT.
6. RELOCATE EXISTING FIRE ALARM STROBE AS NECESSARY TOAVOID NEW MARKER BOARD.
7. EXISTING EMERGENCY NOTIFICATION PHONE TO REMAIN.
8. PROVIDE FIRE ALARM SMOKE DETECTOR TO MATCH EXISTINGAND CONNECT TO EXISTING INITIATING CIRCUIT.
GENERAL NOTES1. SEE DRAWING E001.
2. SEE DRAWING T401 FOR A/V SPECS.
3. ALL VOICE, DATA, AND COAX CABLING SHALL BE FED FROMEXISTING TELECOM ROOM A016B. PROVIDE PATCH PANELSAS REQUIRED.
4. COORDINATE ALL DEVICE LOCATIONS WITH MARKERBOARDS, ETC.
5. SEE DRAWING ED201 FOR TECHNOLOGY DEMOLITION.
RENOVATION LEGENDWORK TO BE INSTALLED
EXISTING WORK TO REMAIN.
(EXISTING TELECOM ROOM)
TV+60"1
6 6 6
PR
PR
PR
PR
2
D
AP
D
2
TEACHERPODIUM
5D/1V
ENS
6 6 6
6 6 6
TEACHERPODIUM
5D/1V
ENS
2
D
D
2
6 6 6
AP
F
F
4
6
ENS
F5
F
F
F
F
8
8
8
8
AP
AP
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\T20
1 - L
OW
ER L
EVEL
PLA
N -
TEC
HN
OLO
GY.
dwg,
5/1
/201
8 2:
46:0
3 PM
GENERAL NOTES1. THESE DOCUMENTS REPRESENT OWNER INPUT DATED
4/2/2018. VERIFY ALL REQUIREMENTS PRIOR TO BIDDING.
2. SEE DRAWING E001.
ROOM 023
ROOMS 017 & 019
P:\2
018\
1802
9 - I
SU –
Roo
t Hal
l Low
er L
evel
Cla
ssro
om R
enov
atio
n\D
raw
ings
\T40
1 - A
V D
ETAI
LS.d
wg,
5/1
/201
8 2:
39:5
0 PM