![Page 1: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/1.jpg)
ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN
CORRIENTE CONTÍNUAJ U A N J O S É M I L Ó N G U Z M Á N , U N I V E R S I D A D L A S A L L E , J J M I L O N @ U L A S A L L E . E D U . P E
M A R C O A N T O N I O Z Ú Ñ I G A D Í A Z , M A J E S T R A D I C I Ó N S A C , M A Z U N I G A @ P I S C O M A J E S . C O M
H E R B E R T J E S Ú S D E L C A R P I O B E L T R Á N , M A J E S T R A D I C I Ó N S A C , C . O P E R A C I O N E S @ P I S C O M A J E S . C O M
H E C T O R C H A R A S U R C O , U N I V E R S I D A D C A T Ó L I C A S A N T A M A R Í A , H E C T O R . C H A R A . S U R C O @ G M A I L . C O M
![Page 2: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/2.jpg)
INTRODUCCIÓN
o Acceso a recursos en zonas rurales aisladas
o Geografía arequipeña rural
o Ampliación de la frontera agrícola
o Eficiencia de los sistemas solares fotovoltaicos
![Page 3: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/3.jpg)
INTRODUCCIÓN
o Acceso a recursos en zonas rurales aisladas
o Geografía arequipeña rural
o Ampliación de la frontera agrícola
o Eficiencia de los sistemas solares fotovoltaicos
![Page 4: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/4.jpg)
MODELO EXPERIMENTALPlanta piloto:
A) Sistema de captación solar
B) Sistema de bombeo solar
C) Sistema de bombeo auxiliar
![Page 5: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/5.jpg)
MODELO EXPERIMENTALPlanta piloto:
A) Sistema de captación solar
![Page 6: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/6.jpg)
MODELO EXPERIMENTALPlanta piloto:
B) Sistema de bombeo solar
![Page 7: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/7.jpg)
MODELO EXPERIMENTALPlanta piloto:
B) Sistema de bombeo solar
![Page 8: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/8.jpg)
MODELO EXPERIMENTALPlanta piloto:
B) Sistema de bombeo solar
![Page 9: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/9.jpg)
MODELO EXPERIMENTALPlanta piloto:
C) Sistema de bombeo auxiliar
![Page 10: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/10.jpg)
INSTRUMENTACIÓN Y CONTROL
Radiación SolarPiranómetro:
Potencia FotovoltaicaCaída de tensión y corriente en los paneles
Conversor VCD/VCD: Conversor ICD/ mVCD:
![Page 11: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/11.jpg)
INSTRUMENTACIÓN Y CONTROLPotencia Hidráulica
Medición de flujo
Altura dinámica total
![Page 12: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/12.jpg)
INSTRUMENTACIÓN Y CONTROL
Flujo másico
Altura dinámica total
Radiación solar
Caída de tensión, [V]
Corriente eléctrica, [A]
USB
![Page 13: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/13.jpg)
PARÁMETROS A EVALUAR
Parámetro IncertezaRadiación Solar 0,5%Corriente eléctrica 0,5%Tensión eléctrica 0,1%Presión hidráulica 0,3%Diferencia de presión 0,5%
Paneles fotovoltaicos:
• Corriente eléctrica, A
• Caída de tensión, V
Bomba Solar
• Altura dinámica total, m
• Flujo másico, kg/s
Supervisor:
• Periodo de funcionamiento de la bomba solar
• Parámetros ambientales (radiación solar, temperatura, velocidad del viento, etc.)
Tabla 1. Incertezas analizadas.
![Page 14: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/14.jpg)
RESULTADOS
DESEMPEÑO DEL SISTEMA DE PANELES FOTOVOLTAICOS
![Page 15: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/15.jpg)
RESULTADOS
DESEMPEÑO DEL SISTEMA DE BOMBEO
![Page 16: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/16.jpg)
RESULTADOS
BALANCE DE ENERGÍA
![Page 17: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/17.jpg)
RESULTADOS
EFICIENCIAS
![Page 18: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/18.jpg)
RESULTADOS
![Page 19: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/19.jpg)
RESULTADOS
![Page 20: ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO ...perusolar.org/wp-content/uploads/2016/07/ESTUDIO...ESTUDIO EXPERIMENTAL DE UN SISTEMA DE BOMBEO SOLAR FOTOVOLTAICO EN CORRIENTE CONTÍNUA](https://reader035.fdocument.pub/reader035/viewer/2022071603/613dccf02809574f586e3107/html5/thumbnails/20.jpg)
CONCLUSIONES
Los resultados en planta indican un flujo de agua de hasta 6 kg/s
la eficiencia de los paneles fotovoltaicos estuvo cerca del 9%
la eficiencia hidráulica de la bomba alrededor del 55%.
La eficiencia global del sistema fue de cerca al 5%,
GRACIAS