Efficienza energetica: Case Study Palazzina M+A
-
Upload
montagnoli-evio -
Category
Real Estate
-
view
659 -
download
0
description
Transcript of Efficienza energetica: Case Study Palazzina M+A
![Page 1: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/1.jpg)
111
Efficienza energetica:Case Study Palazzina M+AArch. Alessandro Vanoni
.
![Page 2: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/2.jpg)
22
Inquadramento territoriale, orientamento, esposizione
NE
![Page 3: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/3.jpg)
33
Inquadramento territoriale, orientamento, esposizione
![Page 4: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/4.jpg)
44
Inquadramento territoriale
1. Comune di Arsago Seprio via Garzonio
2. Marginale al centro storico
3. Presenza di edifici con tipologia costruttiva disomogenea
4. Sull’area oggetto di intervento è presente un edificio dismesso (tettoia)
Orientamento• L’area è orientato secondo un asse ovest – est via Garzonio
Esposizione• Presenza di edifici complessi pluripiano a Nord ed a Ovest (Possibili Contributi).
• Non sono presenti altri contributi schermanti naturali sugli altri lati. In particolare a Sud l’area confinante è priva di elementi utili al fine dell’ombreggiamento.
![Page 5: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/5.jpg)
55
APPORTI SOLARI GRATUITI
La mancanza a sud di schermature naturali o artificiali (edifici) per il Periodo
INVERNALE costituisce un APPORTO SOLARE GRATUITO da sfruttare.
Mentre costituisce un problema da affrontare per il periodo estivo
La presenza di un edificio pluripiano ad Est costituisce un CONTRIBUTO per il periodo estivo (OMBREGGIAMENTO)
![Page 6: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/6.jpg)
66
DATI DI PROGETTO
SUPERFICIE FONDIARIA: 1250,50 MQ
SLP COMPLESSIVA IN PROGETTO 600,00 MQ
ALTEZZA MASSIMA LATO NORD 12,65 M
ALTEZZA MASSIMA LATO SUD 9,50 M
![Page 7: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/7.jpg)
77
FORMA DELL’EDIFICIO
CompattoForma semplice e regolare Superfici esposte molto contenute .Ottimo rapporto S/V
![Page 8: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/8.jpg)
88
FORMA DELL’EDIFICIO
S/V Progetto = 0,68 (valore consigliato per edifici Energy Plus < 0,80)
![Page 9: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/9.jpg)
99
CARATTERISTICHE TECNICHE
Edificio interamente realizzato con tecnologia a secco
Struttura portante in legno XLAM verticale ed orizzontale,
Scale e vano ascensore in Xlam o lamellare
Struttura balcone staccata e priva di continuità con il solaio interno (travetti e assito)
Basamento costituito da Platea in cemento armato a doppia armatura (No Presenza di autorimessa interrate
VANTAGGI
Ottima tenuta all’aria (Pannello XLAM certificato e a 5 strati)
Ottima tenuta al vento (Intonaco esterno e continuità parete verticale copertura)
Struttura antisismica
Ottima resistenza al fuoco
OBBIETTIVI
Massima efficienza dell’INVOLUCRO riducendo le perdite (Qv e QT) . Ridurre consumo di energia primaria
![Page 10: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/10.jpg)
1010
INVOLUCRO ABITATIVO - STRATIGRAFIE -
![Page 11: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/11.jpg)
1111
INVOLUCRO ABITATIVO - STRATIGRAFIE -
PARETE PERIMETRALE
![Page 12: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/12.jpg)
1212
INVOLUCRO ABITATIVO - STRATIGRAFIE -
![Page 13: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/13.jpg)
1313
INVOLUCRO ABITATIVO - STRATIGRAFIE -
![Page 14: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/14.jpg)
1414
Isolamento fondazione interna
![Page 15: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/15.jpg)
1515
Tenuta all’aria
![Page 16: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/16.jpg)
1616
Test Tenuta all’aria Verifica n50
L’edificio verrà sottoposto al doppio Blower-door Test (AeB) per verifica la tenuta all’aria dell’edificio, condizione essenziale per ridurre al minimo le perdite per Ventilazione. (Qv).
![Page 17: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/17.jpg)
1717
Tenuta all’aria
![Page 18: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/18.jpg)
1818
Tenuta all’aria
![Page 19: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/19.jpg)
1919
Nastri tenuta all’aria sotto X-Lam
![Page 20: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/20.jpg)
2020
Scatolette elettriche della Kaiser per tenuta all’aria
![Page 21: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/21.jpg)
2121
Tenuta all’Aria impianti
![Page 22: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/22.jpg)
2222
Posa pannello x-lam
![Page 23: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/23.jpg)
2323
INVOLUCRO ABITATIVO - FINESTRE -
SERRAMENTO INTERNORM THERMO-PASSIVE 400 KF
Uw: 0,69 W/mqK
![Page 24: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/24.jpg)
2424
INVOLUCRO ABITATIVO - FINESTRE -
![Page 25: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/25.jpg)
2525
DATI FINALI
DATI ENERGETICI DI PROGETTO
FABBISOGNO TERMICO PER RISCALDAMENTO E RAFFRESCAMENTO
20 Kwh/mqa
CLASSE ENERGETICA A+DATI CASE PASSIVE
FABBISOGNO TERMICO PER RISCALDAMENTO E RAFFRESCAMENTO
≤ 15 Kwh/mqa
![Page 26: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/26.jpg)
2626
Tabella IE
![Page 27: Efficienza energetica: Case Study Palazzina M+A](https://reader036.fdocument.pub/reader036/viewer/2022062514/5592ee851a28ab76138b4596/html5/thumbnails/27.jpg)
2727
GRAZIE PER L’ATTENZIONE
Studio di architettura vanonidott. Arch. Alessandro Vanoni
via Molini Trotti n°43 Induno Olona (VA)
Tel/fax 0332/202838 cell. 347/0042435
Membro e progettista gPHiGruppo Passive House Italia