云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved....

72
Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 1 云计算实验室解决方案

Transcript of 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved....

Page 1: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 1

云计算实验室解决方案

Page 2: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 2

• 云计算实验室需求背景

• 思科云计算实验室解决方案

• 思科云计算实验室方案介绍

• 思科云计算实验室方案FlexPod打包产品介绍

• 思科云计算实验室技术特点及优势

• 网络架构

• 统一计算架构

• 厂商联盟

• 云基础设施自动化管理平台介绍

• 相关案例参考

Page 3: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 3

• 能够掌握云计算系统部署的知识;对云计算三步走(池化-虚拟化-自动化)有较清晰直观认识。

• 对云计算数据中心网络新特性的学习和掌握。

(FCoE、DCE、VM-FEX…)

• 学生能够熟悉虚拟化的部署,配置等;

• 能够了解应该如何搭建虚拟化环境;

• 能够实现对云计算系统的搭建;

• 能够熟练使用云计算系统;

• 能够完成对云计算系统的运维;

Page 4: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 4

人员 企业

充满云的世界

用充满云的世界连接人员和企业

政府

医疗卫生

媒体

专用

混合

公共

其它

Page 5: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 5

整合

基本功能 高质量功能 合作伙伴 业务的推动者

数据中心整合 应用整合 服务器整合 网络整合 存储整合

虚拟化

服务器虚拟化 网络虚拟化 存储虚拟化 桌面虚拟化 应用虚拟化 绿色数据中心

灵活IT

自动化供应管理 面向业务IT管理动态基础架构 能力需求规划

ITaaS

以服务为中心的IT管理模式 SLA管理 云计算

业务目标

“云计算”数据中心的正确发展之路

Page 6: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 6

“云计算” 服务平台新模式

IT资源交付和自动

部署

配置

服务模式

云平台管理员

操作

监控

虚拟机

资源池

公共服务云

私有云

资源调度

监督及审核

流程化

自动化

安全管理

应用管理 交付和自动化 基础架构管理

备份及冗余

自服务

自服务管理视图

新服务模式及用户体验

业务人员

Page 7: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 7

起点

时间

价值

规划期近期以全面部署 服务器虚拟化为目标

自动化

私有云

垂直IaaS试点项目

互联云

虚拟化

规划期中期以基本实现 业务部署管理自动化为目标

3-5年规划期

规划期远期以基本实现 私有云部署为目标

长期演进目标为 基于标准的互联云 小规模“垂直”试点项目对少量

应用进行蛙跳式的技术试点,摸索技术、维护、人员培训等经验,

作为主要演进路线的辅助 复制到全网

特定应用、特定范围

1. 服务器虚拟化 2. 数据中心融合

• 云计算管理平台

• 云计算安全运营中心 • 应用向云计算平台迁移

• 统一通信协作

1. 跨数据中心(端到端)虚拟化 2. 基于云平台的业务连续性部署

“云计算”数据中心建设路线图

Page 8: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 8

• 学生能够熟悉虚拟化的部署,配置等;

• 能够了解应该如何搭建虚拟化环境;

• 能够掌握云计算系统部署的知识;

• 能够实现对云计算系统的搭建;

• 能够熟练使用云计算系统;

• 能够完成对云计算系统的运维;

Page 9: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 9

FlexPod--打包在一起的Mini数据中心 通往云计算数据中心、搭建云计算实验室的捷径

• 经过预先验证的同类最佳标准基础架构构建块

• 一个平台可以灵活扩展,以适应各种环境和混合工作负载

• 简化管理,可重复部署

• 设计和容量评估手册丰富

• 系统实施的风险降低

• 加快部署针对各种不同环境数据中心

VMware 、Microsoft etc.

Cisco® UCS B/C

and UCS Manager

Cisco Nexus®

Family Switches

NetApp® FAS

Hypervisor

Page 10: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 10

Consistent architecture from entry to large configurations

Scale up or down with ease

Common structure for support & management

FlexPod-- 灵活的规模设计,一致的架构、一致的支持和管理

Page 11: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 11

FlexPod-- 帮助云计算实验室快速部署

> 50% 加速

数周或数月

服务请求

采购 细化设计 部署 测试

服务就绪

传统方式

使用FlexPod 可参照的设备清单

验证过的设计

精确的部署

标准化的测试

采购 部署 测试

预提供的FlexPod 应用快速部署

满足大多数需求的共享资源池

服务就绪

X X

采购 部署 测试

服务就绪

优势 灵活的服务提供

更高的生产效率

更快速的部署

更高的质量

更简单的规划

数据中心准备

设计和容量评估

数据中心准备

数据中心准备

Page 12: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 12

与Hypervisors相集成 自动化的工作流,可通过API进行平台扩展

支持VMware vCenter、MS System Center

Cisco® UCS Manager 内嵌式的统一管理工具

与VMware vCenter或MS SystemCenter集成

NetApp® OnCommand™

Management Software 控制、自动化、分析

与VMware vCenter或MS SystemCenter集成

管理混合的NetApp环境

Apps NetApp

Storage Plug-ins

Cisco UCS Manager

FlexPod-- 集中化和开放的管理平台

通过开放的API扩展管理平台

Hypervisor Hypervisor Hypervisor Hypervisor

Page 13: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 13

vSphere/Hyper-V Cisco UCS/Nexus NetApp Storage

使用统一的存储架构简化存储部署

提供从服务器到存储的所有协议互连

内置的高效性,例如重复数据删除,FlexClone、Snapshot等

UCS提供无状态计算

UCSM和VCenter/SCVMM实现配置同步和集成

VM-FEX实现硬件环境下的虚拟化感知,提供精细化流量控制和管理

统一交换矩阵整合数据和存储网络

vSphere/Hyper-V提供端到端的虚拟机配置和快速克隆

降低数据中心的部署成本

减少对于电源、空调和机房空间的需求

Network

Servers

构架于FlexPod 上的vSphere和Hyper-V

Hypervisor

Page 14: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 14

构架于FlexPod 上的Windows Server

Compute Network Storage

UCS Nexus FAS

Management Virtualization Architectures

PowerShell

•OPERATIONS MANAGER 2012 提供FlexPod日常运行的健康视图,实现从硬件(Cisco UCS, Nexus, NetApp Storage),操作系统及应用的全面监控管理;

•SC Orchestration提供指令总线,实现对FlexPod资源调用的自动化;

•SC Virtual Machine Manager实现FlexPod虚拟资源的管理

Cisco® UCS B-

Series Blade

Servers and UCS

Manager

Cisco Nexus®

Family Switches

NetApp FAS

Storage Systems

Page 15: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 15

Unified Computing System

Storage

VM-FEX

Nexus

Nexus 1KV

S C

O

rch

estr

ato

r

SC

VM

M

SC

OM

+ Hyper-V

思科和微软合作总体框架

架构和运维层

应用层

虚拟化层

Page 16: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 16

经过验证的最佳实践文档

Cisco NetApp Alliance Portal

( cisconetapp.com )

Page 17: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 17

Internet接入 内网广域网接入

WAAS

邮件安全

Web 安全

防火墙

负载均衡

WAAS

邮件安全

Web 安全

防火墙

负载均衡

运营商1 运营商2 广域网

DNS

邮件

DNS

邮件

用FlexPod构架“云计算”数据中心

统一的网络资源

统一的计算资源

统一的存储资源

Page 18: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 18

采用经过简化、预先验证的共享架构降低风险

使用FlexPod带来的价值

可扩展的灵活 IT,满足现在以及将来的需求

降低 TCO 并提高效率

经认证的数据中心专业合作伙伴和合作支持

VMware/Microsoft NetApp Cisco

Page 19: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 19

云计算实验室建设

Page 20: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 20

• Cisco UCS C系列机架式服务器嵌入式CIMC平台管理,可与刀片系统整合入同一架构。

• Cisco虚拟网卡提供IO虚拟化,优化资源利用。

• Cisco Nexus 5500配合虚拟网卡和虚拟化软件,使用VM-FEX将虚拟机直连入物理网络,实现精细化流量控制和管理。

• NetApp FAS2240统一存储提供FC/iSCSI与NAS多种存储协议支持,结合消重技术使用,灵活满足虚拟数据中心的高效数据存储需求。

• FlexPod A是针对小企业虚拟化业务设计的,使用基于千兆/万兆网络连接带宽和NAS/FC SAN存储的高性价比解决方案。

• 支持虚拟化平台Microsoft Hyper-V,可以使用虚拟机来部署如小型数据库、Web服务器、邮件服务器、打印服务器、认证服务器、代理服务器等。

FlexPod A– 迷你型数据中心解决方案(for Microsoft)

方案概览 适用场景

架构优势

UCS C220 M3*3

P81E VIC*3

Nexus 5548*1

FAS 2240*1

• 针对迷你型应用规模

• 使用机架式服务器+虚拟化进行部署

• 关注硬件环境下的虚拟化感知

• 要求具有较好的灵活性和扩展性

• 对系统性能有一定要求并需要较低的TCO

• 减少系统风险,加快应用部署

• 平滑升级至中级规模

Hyper-V (option)

Page 21: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 21

• Cisco UCS C系列机架式服务器嵌入式CIMC平台管理,可与刀片系统整合入同一架构。

• Cisco虚拟网卡提供IO虚拟化,优化资源利用;

• Cisco Nexus 5500配合虚拟网卡和虚拟化软件平台,使用VM-FEX将虚拟机直连入物理网络,实现精细化流量控制和管理。

• NetApp FAS2240统一存储提供FC/iSCSI与NAS多种存储协议支持,结合消重技术使用,灵活满足虚拟数据中心的高效数据存储需求。

• FlexPod A是针对小企业虚拟化业务设计的,使用基于千兆/万兆网络连接带宽和NAS/FC SAN存储的高性价比解决方案。

• 支持虚拟化平台VMware VSphere,可以使用虚拟机来部署如小型数据库、Web服务器、邮件服务器、打印服务器、认证服务器、代理服务器等。

FlexPod A– 迷你型数据中心解决方案(for VMware)

方案概览 适用场景

架构优势

UCS C220 M3*3

P81E VIC*3

Nexus 5548*1

FAS 2240*1

• 针对迷你型应用规模

• 使用机架式服务器+虚拟化进行部署

• 关注硬件环境下的虚拟化感知

• 要求具有较好的灵活性和扩展性

• 对系统性能有一定要求并需要较低的TCO

• 减少系统风险,加快应用部署

• 平滑升级至中级规模

vSphare 5.1

(Option)

Page 22: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 22

产品订货号 产品描述 数量 Cisco UCS C series

UCS-SP5-C220V UCS C220 M3 SFF w/ 2650 8x8GB P81E VIC 2PS 3

CAB-250V-10A-CN AC Power Cord - 250V 10A - PRC 6

N20-BBLKD UCS 2.5 inch HDD blanking panel 24

N2XX-ACPCI01 Cisco UCS P81E Virtual Interface Card/ 2-port 10Gbps 3

UCS-CPU-E5-2650 2.00 GHz E5-2650/95W 8C/20MB Cache/DDR3 1600MHz 6

UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v 24

UCS-RAID-9266CV MegaRAID 9266CV-8i w/TFM + Super Cap 3

UCSC-HS-C220M3 Heat Sink for UCS C220 M3 Rack Server 6

UCSC-PSU-650W 650W power supply for C-series rack servers 6

UCSC-RAIL1 Rail Kit for C220 C22 C24 rack servers 3

Cisco Nexus 5548UP

N5K-C5548UP-FA Nexus 5548 UP Chassis 32 10GbE Ports 2 PS 2 Fans 1

N5548-ACC-KIT Nexus 5548 Chassis Accessory Kit 1

N55-M-BLNK Nexus 5500 Module Blank Cover 1

N55-DL2 Nexus 5548 Layer 2 Daughter Card 1

SFP-H10GB-CU3M 10GBASE-CU SFP+ Cable 3 Meter 4

GLC-T 1000BASE-T SFP 4

DS-SFP-FC8G-SW 8 Gbps Fibre Channel SW SFP+, LC 2

N55-VMFEXK9 Nexus 5500 series VM-FEX license 1

N5KUK9-513N2.1 Nexus 5000 Base OS Software Rel 5.1(3)N2(1) 1

SFS-250V-10A-CN SFS Power Cord - 250V 10A - PRC 2

N5548P-FAN Nexus 5548P and 5548UP Fan Module Front to Back Airflow 2

N55-PAC-750W Nexus 5500 PS 750W Front to Back Airflow(Port-Side Outlet) 2

N55-8P-SSK9 Nexus 5500 Storage License, 8 Ports 1

NetApp FAS2240-2

FAS2240-2-12X450-R5 FAS2240-2,12x450GB,Base 1

SW-CIFS-C SW,CIFS,-C 1

SW-FCP-C SW,FCP,-C 1

SW-ISCSI-C SW,iSCSI,-C 1

SW-NFS-C SW,NFS,-C 1

SW-2240-ONTAP8-P SW,Data ONTAP Essentials,2240,-P 1

SW-2240-SNAPVAULT-P SW,SnapVault,2240,-P 1

X5526A-R6 Rackmount Kit,4-Post,Universal,R6 1

X800I-R6 Power Cable China,R6 2

CS-A2-NBR SupportEdge Standard Part Replace NBD 1

X1150A-R6 CARD Mezzanine 2-port 8G FC 1

FlexPod A详细配置

45万内用户预算,搞定!

配置说明:

Cisco UCS C系列

C220 M3*3

CPU: E5-2650*2

MEM: 64G

NIC: P81E VIC

Cisco Nexus 5548UP

32个UP端口、4个1000Base-T接口、4根10G FCoE铜缆线、2个8G多模FC模块,VM-FEX软件许可,8端口storage软件许可。

NetApp FAS2240-2

硬件:单存储控制器,6GB缓存,4*1GbE千兆以太网端口(Copper),12*450GB 10K SAS磁盘,

2*8Gb FC主机接口。

既支持NAS,有支持SAN

3年标准质保服务

Page 23: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 23

FlexPod A Option

厂商 产品 产品订货号 产品描述 数量

VMware vSphare 5.1 UCS-VMW-N1K-V-BUN VSphere Ent+, Nexus 1000V, & VSG w/

purchase of UCS 6

厂商 产品 产品订货号 产品描述 数量

Microsoft Hyper-V MSWS-08R2-DCHV2S Windows Svr 2008 R2-2 CPU- Data

Cente 3

• FlexPod 可以增加Microsoft或者是VMware,给客户提供一体化解决方案。

Page 24: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 24

• 冗余的刀片控制器、SAN交换机和存储控制器保证系统无单点故障。

• Cisco虚拟网卡提供IO虚拟化,优化资源利用。

• Cisco FI 6248配合虚拟网卡和虚拟化软件,使用VM-FEX将虚拟机直连入物理网络,实现精细化流量控制和管理。

• FCoE减少布线和管理,实现网络融合。

• Service Profile实现计算资源灵活部署

• NetApp FAS2240统一存储提供FC/iSCSI与NAS多种存储协议支持,结合消重技术使用,灵活满足虚拟数据中心的高效数据存储需求。

• FlexPod B是针对小型或者入门级数据中

心业务设计、使用基于万兆网络连接带宽和FC SAN存储的高性价比解决方案。

• 支持多种虚拟化平台: VMware 、Microsoft等。

FlexPod B– 小型数据中心解决方案

方案概览 适用场景

架构优势

UCS 5108*1

UCS B200 M3*8

MDS 9148*2

FAS 2240 HA System

• 对系统的冗余性和可靠性要求较高

• 使用2路刀片服务器+虚拟化进行部署

• 较高密度的计算资源提供,例如VDI

• 关注硬件环境下的虚拟化感知

• 采用万兆以太网和FC SAN存储

• 要求统一存储平台,满足不同数据类型灵活存储及访问需求。

UCS 6248UP*2

Page 25: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 25

FlexPod B详细配置 产品订货号 产品描述 数量

Cisco UCS B Series

UCS-SP5-EV-B200 UCSB EV PRMO 2FI48 1xCH-4xB200M3w/2x2650 64GB 2xVIC 1

UCS-SP-INFRA-CHSS UCS SP BASE 5108 Blade Svr AC Chassis 1

N01-UAC1 Single phase AC power module for UCS 5108 1

N20-CAK Access. kit for 5108 Blade Chassis incl Railkit, KVM dongle 1

N20-CBLKB1 Blade slot blanking panel for UCS 5108/single slot 8

N20-FAN5 Fan module for UCS 5108 8

N20-FW010 UCS 5108 Blade Server Chassis FW package 1

UCS-IOM-2208XP UCS 2208XP I/O Module (8 External, 32 Internal 10Gb Ports) 2

UCSB-PSU-2500ACPL 2500W Platinum AC Hot Plug Power Supply for UCS 5108 Chassis 4

CAB-AC16A-CH 16A AC Power Cord For China 4

UCS-SP-INFRA-FI UCS 6248 FI w/ 12p LIC Cables Bundle 2

DS-SFP-FC8G-SW 8 Gbps Fibre Channel SW SFP+, LC 12

SFP-10G-SR 10GBASE-SR SFP Module 4

SFP-H10GB-CU3M 10GBASE-CU SFP+ Cable 3 Meter 8

UCS-ACC-6248UP UCS 6248UP Chassis Accessory Kit 2

UCS-BLKE-6200 UCS 6200 Series Expansion Module Blank 2

UCS-FAN-6248UP UCS 6248UP Fan Module 4

UCS-FI-DL2 UCS 6248 Layer 2 Daughter Card 2

UCS-PSU-6248UP-AC UCS 6248UP Power Supply/100-240VAC 4

SFS-250V-10A-CN SFS Power Cord - 250V, 10A - PRC 4

N10-MGT010 UCS Manager v2.0 2

UCS-SP5-ENTV-B200 UCS B200 M3 Blade Server w/ 2650 8x8GB Dual VIC 4

N20-BBLKD UCS 2.5 inch HDD blanking panel 8

UCS-CPU-E5-2650 2.00 GHz E5-2650/95W 8C/20MB Cache/DDR3 1600MHz 8

UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v 32

UCS-VIC-M82-8P Cisco UCS VIC 1280 dual 40Gb capable Virtual Interface Card 4

UCSB-HS-01-EP CPU Heat Sink for UCS B200 M3 and B420 M3 8

UCSB-MLOM-40G-01 Cisco UCS VIC 1240 modular LOM for M3 blade servers 4

GLC-T= 1000BASE-T SFP 4

UCS-EZ-ENTV-B200 UCS B200 M3 Blade Expansion w/ 2650 8x8GB Dual VIC 4

N20-BBLKD UCS 2.5 inch HDD blanking panel 8

UCS-CPU-E5-2650 2.00 GHz E5-2650/95W 8C/20MB Cache/DDR3 1600MHz 8

UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v 32

UCS-VIC-M82-8P Cisco UCS VIC 1280 dual 40Gb capable Virtual Interface Card 4

UCSB-HS-01-EP CPU Heat Sink for UCS B200 M3 and B420 M3 8

UCSB-MLOM-40G-01 Cisco UCS VIC 1240 modular LOM for M3 blade servers 4

配置说明:

Cisco UCS B系列

6248*2

5108 (with 2208) *1

B200M3*8

CPU: E5-2650*2

MEM: 64G

NIC: VIC 1280*1, VIC 1240*1

Page 26: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 26

FlexPod B详细配置-续

产品订货号 产品描述 数量

Cisco MDS 9148

DS-C9148D-8G16P-K9 MDS 9148 with 16p enabled 16x8GFC SW optics 2 PS 2

NetApp FAS2240

FAS2240-2-R5 1

CS-A2-NBR SupportEdge Standard Part Replace NBD 1

SW-2240A-ONTAP8-P SW,Data ONTAP Essentials,2240A,-P 2

SW-2240A-SRESTORE-C SW,SnapRestore,2240A,-C 2

SW-CIFS-C SW,CIFS,-C 2

SW-FCP-C SW,FCP,-C 2

SW-ISCSI-C SW,iSCSI,-C 2

SW-NFS-C SW,NFS,-C 2

F2240A-2-24X450-R5 FAS2240-2,HA,24x450GB,Dual CTL 1

X5526A-R6 Rackmount Kit,4-Post,Universal,R6 1

X800I-R6 Power Cable China,R6 2

X1150A-R6 CARD Mezzanine 2-port 8G FC 2

X6557-R6 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m 2

X6560-R6 Cable,Ethernet,0.5m RJ45 CAT6 1

FAS2240A-HA-SW-R5 FAS2240A,HA CFO Software,R5 2

配置说明:

Cisco MDS 9148

48个8G FC接口、16个端口激活许可、16个8G FC模块

NetApp FAS2240-2

硬件:双活存储控制器,12GB缓存,4*8Gb FC前端主机端口,8*1GbE

千兆以太网端口(Copper),24*450GB

10K SAS磁盘。

既支持NAC,又支持SAN

3年标准质保服务

90万内用户预算,搞定!

Page 27: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 27

FlexPod B Option

厂商 产品 产品订货号 产品描述 数量

VMware vSphare 5.1 VMW-VS5-ENT-1A VMware vSphere 5 Enterprise (1 CPU), 1yr

Support Required 16

厂商 产品 产品订货号 产品描述 数量

Microsoft Hyper-V MSWS-08R2-

DCHV2S Windows Svr 2008 R2-2 CPU- Data Cente 8

• FlexPod可以增加Microsoft或者是VMware,给客户提供一体化解决方案

Page 28: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 28

• 虚拟网卡提供IO虚拟化,优化资源利用。

• Cisco FI 6248配合虚拟网卡和虚拟化软件,使用VM-FEX将虚拟机直连入物理网络,实现精细化流量控制和管理。

• FCoE减少布线和管理,实现网络融合。

• Service Profile实现计算资源灵活部署

• Nexus 5500整合数据和存储网络,通过vPC

实现链路负载均衡和高可用。

• NetApp FAS3240统一存储提供FC/iSCSI与NAS多种存储协议支持,结合消重技术与自动分层技术的使用,灵活满足虚拟数据中心的高效/高性能数据存储需求。

• FlexPod C是针对中型或者部门级数据中

心业务设计、融合数据网络和存储网络、使用基于万兆网络连接带宽和FC SAN存储的高性价比解决方案,提供更高性能的网络、计算和存储平台。

• 支持多种虚拟化平台: VMware 、Microsoft等。

FlexPod C– 中型数据中心解决方案

方案概览 适用场景

架构优势

Nexus 5548UP*2

FAS 3240 HA System

• 对系统的冗余性和可靠性要求高

• 使用4路和2路刀片服务器+虚拟化部署

• 统一网络架构整合数据和存储网络

• 关注硬件环境下的虚拟化感知

• 采用万兆以太网和FC SAN存储

• 要求统一存储平台,满足不同数据类型灵活存储及高性能访问需求。

UCS 6248UP*2

UCS 5108*2

UCS B200 M3*8

UCS B440 M2*4

Page 29: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 29

FlexPod C详细配置

配置说明:

Cisco UCS B系列

6248*2

5108 (with 2208)*2

B440M2*4

CPU: E7-4830*4

MEM: 128G

NIC: VIC1280

B200M3*8

CPU: E5-2650*2

MEM: 64G

NIC: VIC 1280*1, VIC 1240*1

产品订货号 产品描述 数量

Cisco UCS B Series

N20-Z0001 Cisco Unified Computing System 2

N20-C6508 UCS 5108 Blade Svr AC Chassis/0 PSU/8 fans/0 fabric extender 2

B440-BASE-M2 UCS B440 M2 Blade Server w/o CPU, memory, HDD, mezzanine 4

UCS-CPU-E74830 2.13 GHz E7-4830 105W 8C CPU / 24M Cache 16

UCS-MR-2X041RX-C 2X4GB DDR3-1333-MHz RDIMM/PC3-10600/single rank/x8/1.35v 16

UCS-VIC-M82-8P Cisco UCS VIC 1280 dual 40Gb capable Virtual Interface Card 4

N20-BBLKD UCS 2.5 inch HDD blanking panel 16

N20-BHTS3 CPU heat sink for UCS B440 Blade Server 16

N20-LBLKU Blanking panel for B440 M1 battery backup bay 4

UCS-MKIT-041RX-C Mem kit for UCS-MR-2X041RX-C 32

N20-PAC5-2500W 2500W AC power supply unit for UCS 5108 8

CAB-AC16A-CH 16A AC Power Cord For China 8

UCS-IOM-2208XP UCS 2208XP I/O Module (8 External, 32 Internal 10Gb Ports) 4

N01-UAC1 Single phase AC power module for UCS 5108 2

N20-CAK Access. kit for 5108 Blade Chassis incl Railkit, KVM dongle 2

N20-CBLKB1 Blade slot blanking panel for UCS 5108/single slot 8

N20-FAN5 Fan module for UCS 5108 16

N20-FW010 UCS 5108 Blade Server Chassis FW package 2

UCS-FI-6248UP UCS 6248UP 1RU Fabric Int/No PSU/32 UP/ 12p LIC 2

SFP-H10GB-CU3M 10GBASE-CU SFP+ Cable 3 Meter 4

UCS-ACC-6248UP UCS 6248UP Chassis Accessory Kit 2

UCS-PSU-6248UP-AC UCS 6248UP Power Supply/100-240VAC 4

N10-MGT010 UCS Manager v2.0 2

UCS-BLKE-6200 UCS 6200 Series Expansion Module Blank 2

UCS-FAN-6248UP UCS 6248UP Fan Module 4

UCS-FI-DL2 UCS 6248 Layer 2 Daughter Card 2

UCS-MR-1X082RX-A= 8GB DDR3-1333-MHz RDIMM/PC3-10600/2R/1.35v 48

UCS-EZ-ENTV-B200 UCS B200 M3 Blade Expansion w/ 2650 8x8GB Dual VIC 8

N20-BBLKD UCS 2.5 inch HDD blanking panel 16

UCS-CPU-E5-2650 2.00 GHz E5-2650/95W 8C/20MB Cache/DDR3 1600MHz 16

UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v 64

UCS-VIC-M82-8P Cisco UCS VIC 1280 dual 40Gb capable Virtual Interface Card 8

UCSB-HS-01-EP CPU Heat Sink for UCS B200 M3 and B420 M3 16

UCSB-MLOM-40G-01 Cisco UCS VIC 1240 modular LOM for M3 blade servers 8

SFP-H10GB-CU3M= 10GBASE-CU SFP+ Cable 3 Meter 4

DS-SFP-FC8G-SW= 8 Gbps Fibre Channel SW SFP+ LC Spare 8

SFP-10G-SR= 10GBASE-SR SFP Module 4

Page 30: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 30

配置说明:

Cisco Nexus 5548UP

32个UP端口、L3子卡(含软件许可)、4个8G FC连存储和6248UP、2个10GE连6248、8端口存储许可。

NetApp FAS3240A存储系统

硬件:双活存储控制器,9GB缓存(最大可扩展至521GB),4*4Gb FC

前端主机端口,4*10GbE万兆以太网端口(Fiber),6x100GB SSD,

18*1TB SATA磁盘 Flashpool 配置。

既支持NAS,又支持SAN

3年标准质保服务

FlexPod C详细配置-续

产品订货号 产品描述 数量

Cisco Nexus 5548UP N5K-C5548UP-FA Nexus 5548 UP Chassis 32 10GbE Ports 2 PS 2 Fans 2

N55-D160L3-V2 Nexus 5548 Layer 3 Daughter Card Version 2 2

DS-SFP-FC8G-SW 8 Gbps Fibre Channel SW SFP+, LC 8

SFP-10G-SR 10GBASE-SR SFP Module 4

SFP-H10GB-CU3M 10GBASE-CU SFP+ Cable 3 Meter 8

N55-8P-SSK9 Nexus 5500 Storage License, 8 Ports 2

N55-LAN1K9 Layer 3 License for Nexus 5500 Platform 2

NetApp FAS3240 FAS3240A-IB-BASE-R6 FAS3240 HA System With Controller 2

SW-FCP-C SW,FCP,-C 2

SW-3240A-CIFS-C SW,CIFS,3240A,-C 2

SW-3240A-ONTAP8-C SW,Data ONTAP Essentials,3240A,-C 2

X1139A-R6-C ADPT 2-Port Unified Target 10GbE SFP+ PCIe,-C 2

X2065A-R6-C HBA,SAS,4-Port,3Gb,PCIe,QSFP,-C,R6 2

X6536-R6-C Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C 4

X6561-R6-C Cable,Ethernet,2m RJ45 CAT6,-C 1

X6559-R6-C Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m,-C 4

X6558-R6-C Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m,-C 4

X6562-R6-C Cable,Ethernet,5m RJ45 CAT6,-C 4

DS4246-18TB-24M-R6-C DSK SHLF,6x100GB,18x1TB,Mixed,-C 2

X5515A-R6-C Kit,4N2 Post Rackmount,DS14-Mid,-C,R6 1

X800I-R6-C Power Cable China,-C,R6 6

X5526A-R6-C Rackmount Kit,4-Post,Universal,-C,R6 2

DOC-32XX-C Documents,32XX,-C 1

SUPPORTEDGE SupportEdge Services 1

230万用户预算,搞定!

Page 31: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 31

FlexPod C Option

厂商 产品 产品订货号 产品描述 数量

VMware vSphare 5.1 VMW-VS5-ENT-1A VMware vSphere 5 Enterprise (1

CPU), 1yr Support Required 32

厂商 产品 产品订货号 产品描述 数量

Microsoft Hyper-V MSWS-08R2-DCHV2S Windows Svr 2008 R2-2 CPU- Data

Cente 8

MSWS-08R2-DCHV4S Windows Svr 2008 R2-4 CPU-Data

Center 4

• FlexPod可以增加Microsoft或者是VMware,给客户提供一体化解决方案

Page 32: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 32

云服务自动化管理系统:ICM系统

用户

自动开通

资源管理 系统监控

运营流程

ICM

网络

计算

存储 虚拟化

用户管理

账单管理

VM as a Service Blade as a Service

Page 33: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 33

ICM的功能实现

产品目录

产品定义 发布

自服务门户

业务订购

自动开通

集中管控 管理员

用户

流程触发

性能监视 事件监视 租期监视 资源池管理 虚拟机管理

资源回收/更新

Page 34: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 34

Page 35: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 35

Mgmt Server

UCS-- 创新的统一计算系统架构

Mgmt Server •内嵌式管理系统

•采用统一交换网络

•提升服务器虚拟化特性

•去除不必要的

–交换机,

–网卡,

–管理模块

•减少1/3-1/2的支撑设施完成相同的工作

Mgmt Server

Page 36: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 36

彻底解决机房的布线和散热问题

所有刀片系统都是前后通风,思科UCS独特的整合式架构设计,极大简化了刀片系统,解决了数据中心困扰已久的布线、散热等问题。

Page 37: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 37

1号机箱/2 号刀片 8号机箱/5号刀片

LAN SAN

管理 软件

管理 软件

无状态计算Service Profile -- 让物理服务器“飘起来”

UUID: 56 4d cd 3f 59 5b…

MAC : 08:00:69:02:01:FC

WWN: 5080020000075740 启动顺序: SAN, LAN

Page 38: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 38

FlexPod和Microsoft协同案例 Service Profile Portability with SQL

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

PS

1P

S2

FAN

STAT

FA

N1

FA

N2

FAN

STAT

ST

AT

OK

FAIL

N10-PAC1-550W

OK

FAIL

N10-PAC1-550W

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

SQL Server-Physical

Application Server-VM

Web Server-VM

Page 39: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 39

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

PS

1P

S2

FAN

STAT

FA

N1

FA

N2

FAN

STAT

ST

AT

OK

FAIL

N10-PAC1-550W

OK

FAIL

N10-PAC1-550W

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

FlexPod和Microsoft协同案例 Service Profile Portability with SQL

SQL Server-Physical

Application Server-VM

Web Server-VM

Page 40: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 40

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

PS

1P

S2

FAN

STAT

FA

N1

FA

N2

FAN

STAT

ST

AT

OK

FAIL

N10-PAC1-550W

OK

FAIL

N10-PAC1-550W

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

FlexPod和Microsoft协同案例 Service Profile Portability with SQL

SQL Server-Physical

Application Server-VM

Web Server-VM

Page 41: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 41

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

PS

1P

S2

FAN

STAT

FA

N1

FA

N2

FAN

STAT

ST

AT

OK

FAIL

N10-PAC1-550W

OK

FAIL

N10-PAC1-550W

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

FlexPod和Microsoft协同案例 Service Profile Portability with SQL

SQL Server-Physical

Application Server-VM

Web Server-VM

Page 42: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 42

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

PS

1P

S2

FAN

STAT

FA

N1

FA

N2

FAN

STAT

ST

AT

OK

FAIL

N10-PAC1-550W

OK

FAIL

N10-PAC1-550W

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

Move Service Profile:

Server Name

UUID, MAC,WWN

Boot info

firmware

LAN, SAN Config

Firmware…

FlexPod和Microsoft协同案例 Service Profile Portability with SQL

SQL Server-Physical

Application Server-VM

Web Server-VM

Page 43: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 43

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

PS

1P

S2

FAN

STAT

FA

N1

FA

N2

FAN

STAT

ST

AT

OK

FAIL

N10-PAC1-550W

OK

FAIL

N10-PAC1-550W

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

FlexPod和Microsoft协同案例 Service Profile Portability with SQL

SQL Server-Physical

Application Server-VM

Web Server-VM

Page 44: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 44

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

PS

1P

S2

FAN

STAT

FA

N1

FA

N2

FAN

STAT

ST

AT

OK

FAIL

N10-PAC1-550W

OK

FAIL

N10-PAC1-550W

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

FlexPod和Microsoft协同案例 Service Profile Portability with SQL

SQL Server-Physical

Application Server-VM

Web Server-VM

Page 45: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 45

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

PS

1P

S2

FAN

STAT

FA

N1

FA

N2

FAN

STAT

ST

AT

OK

FAIL

N10-PAC1-550W

OK

FAIL

N10-PAC1-550W

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

! ResetConsole

! !

UCS B200 M1

FlexPod和Microsoft协同案例 Service Profile Portability with SQL

SQL Server-Physical

Application Server-VM

Web Server-VM

Page 46: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 46

VM-FEX -- 让虚拟机直接连入物理网络

物理网络

Hyp

erv

iso

r

Hyp

erv

iso

r

VM VM VM VM VM VM VM VM

虚拟端口

虚拟网卡

虚拟机

统一物理网络和虚拟网络,虚拟机直接连入物理网络;

虚拟机流量可视,可以进行精细化流量控制和管理;

Hypervisor Bypass提升性能30%

端到端的虚拟化 虚拟网络 虚拟网络

Page 47: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 47

硬件高可用-- 保障关键应用的安全

完全硬件级功能

操作系统无需参与,网卡无需做teaming

切换时间极短

无STP收敛时间

操作非常简单

容错与双活

轻易实现容错

双活路径,更高的可用性

特别适用于虚拟化和集群环境

硬件级网络高可用大大简化了数据中心的网络设计和实现。实现了双活路径等重要功能,为包括集群环境在内的绝大多数应用环境提供了更高一级的硬件保障。

Page 48: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 48

增强的安全性以及灵活性,提高网络设备的利用率

MACB

MACA

MACC

A & B C

End nodes

LAN

MACB

MACA

MACC

A & B C

End nodes

LAN

不丢包的以太网以及大大提高数据中心的扩展性

LAN

N5000

Active-Active

MAC B

MAC A

集中了网络资源,减少设备数量,同时也降低了电力和冷却的开销

LAN SAN BSAN ALAN SAN BSAN A

Nexus

合作伙伴

高性能, 低延时, 更经济的10GE 访问连接

LAN

Access Layer Nexus

标准化

Nexus家族-- 统一的数据中心网络平台

Wire speed 10GE

L2 Access Switch

Data Center

Ethernet (DCE) FCoE

Virtualization

Networking

Page 49: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 49

一个架构即可应对各种工作负载

NetApp-- 统一的数据中心存储平台

相同的工具和流程: 学习一次,处处适用

集成的数据管理

集成的数据保护

供应商之间采用统一标准

广泛的系统组合 协议

Flash Cache

SSD

FlexCache®

FC

FCoE

iSCSI

NFS

CIFS

对象 运行 Data ONTAP® 的 NetApp® FAS 和 V 系列

统一管理

性能

Page 50: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 50

Data ONTAP

核心软件

更低的存储需求

以最小开销增强数据可用性

归档

增强存储利用率与部署能力

整合

容灾

使用现有设施做得更多

工作负载优化,增强处理效率

数据归档与法规遵从

增强数据保护,提升可用性

数据管理虚拟化

备份与恢复

持续可用性

Data ONTAP

核心软件

Data ONTAP

数据保护特性

NetApp 统一存储架构产品

软件

Data ONTAP

核心软件

硬件

商业应用

存储管理

数据中心自动化管理

解决方案

NetApp 重复数据删除

NetApp

FlexVol 与精简配置

NetApp

FlexClone

NetApp

Snapshot

NetApp

RAID-DP NetApp

MultiStore

NetApp

FlexShare WAFL

NetApp

SnapVault NetApp

SnapMirror SnapLock

NetApp

SnapRestore

NetApp

MetroCluster

NetApp-- 先进的数据中心存储技术

Page 51: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 51

Page 52: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 52

逐步的, 低风险的变革 – 实践出真知

灵活性

存储整合 服务器整合

时间轴

整合分支结构

整合

提高利用率和效率

自动化

基于策略、自适应的架构

虚拟化

提高灵活性,响应能力

半自动的业务部署

数据中心整合

动态的业务部署

服务器虚拟化

静态的部署

应用虚拟化

存储虚拟化

网络虚拟化

Page 53: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 53

• ***此处是否还需添加针对若干具体技术的slides?

• 网络方面:

• 存储方面:

• 虚拟化方面:

• 自动化方面:

Page 54: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 54

I C M

Page 55: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 55

云基础设施管理平台 ICM

ICM 云基础设施管理平台

云基础设施管理平台解决方案(ICM)是面向企业用户的一款虚拟云计算数据中心运营与管理产品。它为企业私有云系统提

供一个流程化IaaS服务投放工具。ICM系统为用户提供了云产品定义与发布管理,云服务申请,虚拟机自动开通部署及配置、

自助监控、服务支持和信息通告等能力与工具,同时具备REST web service接口,方便与企业内其他第三方应用系统的集成

与数据交互。

ICM的特征与能力

将各种物理资源抽象与池化为计算资源、存储资源和网络资源三类资源池,建立集中、统一、高效、全控的资源配置管理

库。

基于虚拟化技术和IT服务租用模式,产品化用户业务,以虚拟机为载体,为用户提供标准封装,按需使用虚拟服务产品。

标准化用户的服务操作行为,通过统一门户进行选产品,下订单,审核配置,开通部署,运行使用和用毕回收的云服务全

生命周期管理。

快速自动完成服务开通部署,结合便捷的Email服务给用户随时的通知与提示,掌控服务进展与状态。

简捷友好的中文化web浏览器操作界面,轻量Web部署结构,易得,易学,易用。

Page 56: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 56

云基础设施管理平台 ICM

首页Portal 管理员进入系统首页,通过图表结合方式展示了资源、维护单、申请单、客户等统计信息,展示的方式包括表格、柱状图、

仪表盘形式。

Page 57: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 57

云基础设施管理平台 ICM

资源中心 集中统一管理系统所有资源,包括物理资源,虚拟资源和客户资源。物理资源包括刀架,刀片服务器和机架服务器。

虚拟资源包括计算资源,网络资源和存储资源,并统计和呈现当前的资源使用状态与详细信息;客户资源包括客户组和客户。

提供资源数据的同步、分配、操作和统计管理。

Page 58: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 58

云基础设施管理平台 ICM

产品管理 提供主流的数据中心基础服务器:虚拟服务器产品,物理服务器产品。每类产品都提供完整的产品生命周期管理,从产品定

义,维护,发布到退服。每类产品根据各自的技术特征和租用标准化的理念,类比传统的计算机营销模式,把用户对云服务

的各种需求归纳形成不同的产品目录,发布到系统门户供用户挑选和自助申请。为用户提供按需(资源)使用的选择。

Page 59: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 59

云基础设施管理平台 ICM

申请单管理 提供云数据中心服务开通,配置与部署的流程化管理,并监视流程进度与驱动。服务开通流程对数据中心服务投放流程高度

总结和抽象,分为典型的6个阶段:提交,审批,配置,开通,交付与回收。在每个阶段,基于有限状态机与邮件相结合的方

式与操作人员或用户进行友好和及时的交互。

Page 60: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 60

云基础设施管理平台 ICM

账单管理 服务账单是对用户服务申请的资源使用量和时间进行记录和统计,基于用户服务资源使用量进行账单记录,用户可以查询,

也可以导出服务账单。

Page 61: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 61

云基础设施管理平台 ICM

监控中心 提供服务租期监视和服务远程操作维护能力。在服务开通之后,对服务的有效使用时间进行周期监视,基于系统配置的租期

提醒门限,对于超过提醒门限的服务,发送邮件通知用户;对于过期的服务提供资源回收能力。系统提供远程操作和控制用

户服务器的能力,在监控中心,用户可以进行配置查询,管理操作,运行状态监视以及远程终端访问。

Page 62: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 62

ICM 产品功能介绍

自动开通业务流程

服务目录管理

资源视图

ICM1.3 新功能介绍

Page 63: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 63

ICM 自动开通业务流程

1、查看虚拟机产品

2、提交订单申请

3、配置订单

4、审核订单

5、开通部署

7、交付确认

6、交付通知

8、登录虚机

Admin

Customer

Page 64: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 64

ICM 产品功能介绍

自动开通业务流程

服务目录管理

资源视图

ICM1.3 新功能介绍

Page 65: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 65

ICM 服务目录管理 -- 产品定义发布

系统管理员根据需求对虚拟机产品进行定义,内容包括操作系统版本、物理参数配置、月租、服务等级、操作系统用户信息及序列号等;

创建完毕的产品与虚拟机模板绑定,绑定完毕执行发布操作,产品可以在橱窗中展示;

用户可以登录系统查看产品详情,进行产品选购,提交订单申请。

产品发布

产品定义

Page 66: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 66

ICM 服务目录管理 -- 产品分组授权

为虚拟机产品创建逻辑分组, 将虚拟机进行分组归类

将创建的产品组授权给用户

ICM通过产品组的概念进行虚拟机产品的灵活组织与管理。产品组可以随时进行虚拟机产品的添加与删除维护;

系统管理员可以将产品组与用户组进行灵活绑定,组内用户可以访问或定购被授权产品组内的虚机产品;

通过产品组的封装增强了橱窗展示功能的灵活性,为管理员进行产品规划提供了方法。

Page 67: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 67

ICM 服务目录管理 – 硬件VN-Link功能

ICM通过同步UCSM网络策略和vCenter分布式交换机和端口数据读取维护vn-link信息;

创建虚拟机产品时可以根据同步的资源数据,实现带宽控制选择;

该产品创建完毕在橱窗进行展示,以供普通用户进行选购,用户可以根据需要选择合适带宽的虚拟机产品,并向后台管理员提交订单申请;

后台管理员在进行订单资源配置时选择分布式交换机,ICM自动通过产品带宽限制过滤端口组,点击完成,整个配置过程生效。

Page 68: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 68

ICM 产品功能介绍

自动开通业务流程

服务目录管理

资源视图

ICM1.3 新功能介绍

Page 69: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 69

ICM 资源视图 – 资源库视图

资源统计

提供数据中心计算(CPU、主机、内存)、存储、网络资源预览信息数据

支持手动创建资源池

提供硬件VN-Link端口策略信息查看功能

同步UCSM资源 同步vCenter资源

手工同步系统接口数据按钮,系统同时支持自动同步,默认每日凌晨同步1次。

资源详细

资源统计选中计算资源,详细显示主机和资源池的状态和CPU、内存使用率

资源统计选中存储,详细显示本地存储和共享存储的状态和使用率

资源统计选中网络,详细显示标准交换机和分布式交换机的状态和端口使用率

细化资源详情

具体每台主机及资源池信息显示;

具体每个存储信息显示;

具体每台交换机及端口组信息显示。

产品中心\资源池 系统管理员用户登录

Page 70: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 70

ICM 资源视图 – 虚拟机视图

监控中心\配置操作

Admin用户登录查看数据中心所有虚机的信息

高级用户登录查看组内所有虚机的信息

普通用户登录查看自有虚机的信息

基本信息

显示虚拟机基本信息,包括物理配置、OS、IP地址、宿主机、VMTools、状态

浏览器远程登录

点击红色字体虚拟机IP,通过浏览器远程登录访问虚拟机桌面

虚机操作

支持对虚拟机的远程控制操作,包括开关机、挂起、重启,操作系统重启、关闭

操作日志显示 虚拟机启停日志呈现

运行信息

虚拟机运行状态显示,包括CPU使用率、内存使用率、磁盘使用率、网络速率。

虚拟机备份操作

虚拟机同步操作

虚拟机回收操作

Page 71: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 71

ICM 资源视图 – 账单视图

详细信息

导出CSV文件

支持账单列表文件导出

账单查询列表

查询结果显示账单相关信息包括租期开始结束时间、租金信息

账单查询

可以根据订单号\产品名称\虚机名称进行过滤查询

Page 72: 云计算实验室解决方案 - Cisco...© 2010 Cisco and/or its affiliates. All rights reserved. 2Cisco Confidential • 云计算实验室需求背景 • 思科云计算实验室解决方案

Thank you.