EVERY LIFE HAS A PURPOSE…
ModCon® 75 Controller
![Page 2: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/2.jpg)
ModCon75 Controller
The perfect partner to the Ultima® X with X3 Technology!
It’s simple… Connect Assign Start using
Don’t waste time
configuring a new PLC
MSA did it for you!
![Page 3: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/3.jpg)
ModCon75 Overview
ModBus RTU Controller View up to 25 Ultima X3
Transmitters 75 Total Sensors! Self-configuring IP65 / NEMA4X (front-
panel) 12 / 24 VDC
![Page 4: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/4.jpg)
ModCon75 Overview
Bi-directional communication allows changes to be made at either ModCon75 or at the Ultima X3
alarm set points latching/non-latching increasing/decreasing on/off
![Page 5: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/5.jpg)
ModCon75 Overview
Event logging ~ 2000 events 9 - Zone Control Relays 1 - Horn Relay (O9) Sensor alarms
Enable / Disable Alarm On / Off Delay Latching / Unlatching Increasing / Decreasing
Password Protected
![Page 6: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/6.jpg)
ModCon75 Overview
10 SPST Dry Contact Relays SPST, NO relays 5A max per output 8A max for common
7 year battery back-up on memory memory sections real-time clock
ModBus over Ethernet Interface – OPC Compliant (graphic displays, data-logger, etc.)
cUL Listed for panel mount version
![Page 7: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/7.jpg)
ModCon75 Controller
Panel Mount (user installed) 6.1”H x 10.2”W x 3.5”D 3 lbs. Supports up to 25 X3 Transmitters (75 sensors) 9 assignable alarm / zone relays Universal RS232 to RS485 Converter
![Page 8: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/8.jpg)
ModCon75 Enclosures
NEMA 4X Non-metallic Enclosure 17.3”H x 15.3”W x 6.7”D 18 lbs. Supports up to 25 X3 Transmitters (75 sensors) 9 assignable alarm / zone relays 115VAC Power Supply Universal RS232 to RS485 Converter
![Page 9: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/9.jpg)
ModCon75 Main Screen
F1-adds another MODBUS node (UltimaX3 transmitter) to the network F2-sets alarms
Enable / disable increasing / decreasing Energized / de-energized latching / non-latching set-point values
F3-Main Data ScreenF4-Displays set-point values onlyF5-Password Editor - 2 levels
MSA Default User programmable (default=0)
F6-Displays communication statusF7-Fault Status Screen – Automatic
when X3 goes into faultF8-Zone Control – Setting up local relays for alarm and fan controlF9- Remote IO Editor
![Page 10: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/10.jpg)
ModCon75 Controller
F1 Add Units to Network Password protected
(Default=0)
Use this screen to connect
new X3
sensor. Factory default is 247 - this will change address to this number.
Hit ESC to go back to Main Screen
![Page 11: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/11.jpg)
ModCon75 Controller
F2 Add Set-points F2-will take you to
password screen and then to a screen showing current set-point values. These values are read from the X3
Enter advances to next screen
ESC takes you back to main screen
![Page 12: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/12.jpg)
ModCon75 Controller
F2 Add Set-points Cont. Displays Current
Values for Unit # (Node ID) for Sensor 1 presets
F6- Skip to Sensor 2 Presets, enter will allow one to change presets.
![Page 13: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/13.jpg)
ModCon75 Controller
Add Set-points Cont. Sensor 2 Preset Screen
![Page 14: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/14.jpg)
ModCon75 Controller
Add Set-points Cont. Sensor 3 Preset Screen
![Page 15: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/15.jpg)
ModCon75 Controller
Add Set-points Cont. Displays all Presets F7- Sends new presets
to X3
ESC- Aborts and returns to main screen
![Page 16: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/16.jpg)
ModCon75 Controller
Add Set-points Cont. Screen will
indicate successful write or unsuccessful write
![Page 17: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/17.jpg)
ModCon75 Controller
F3 Main Data Screen F1-Scrolls thru all
units (nodes) on the ModBus network
F2- Allows one to view a specific unit (Node)
F3-Adjust the scroll time reading each node
![Page 18: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/18.jpg)
ModCon75 Typical Display
Typical Display showing 3 sensors on node 2 of the Ultima X3 controller
ESC-Back to Main screen
![Page 19: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/19.jpg)
ModCon75 Controller
F4 – Display Sensor presets F4- Display Sensor
presets only (Screen will not allow changing presets)
→ Goes to presets for Sensor 2
![Page 20: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/20.jpg)
ModCon75 Controller
F5 – Password Editor F1-Password Default is
MSA defaulted password
F2- Defaulted Password is 0. User can change this password for unauthorized changes
![Page 21: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/21.jpg)
ModCon75 Controller
F6 – MODBUS Alarms Screen showing
ModBus communications failures and identification of failed unit # (node #)
![Page 22: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/22.jpg)
ModCon75 Controller
F7 – Fault Status Screen Example of Diagnostic
screen Identifying Unit ID as well as the actual fault on unit ID
Automatic when fault occurs
![Page 23: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/23.jpg)
ModCon75 Controller
F8 – Zone Control Enables / disables alarms Increasing / decreasing Latch / unlatch
Setting zone control relays. Screen is password protected
First Screen to enable / disable alarms
Second Screen to set Increasing or Decreasing alarms
![Page 24: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/24.jpg)
ModCon75 Controller
F8 – Zone Control Cont. Third Screen for
setting latching / unlatching alarms
Zone control relays for caution, warning and alarm settings for Sensors 1, 2, and 3
![Page 25: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/25.jpg)
ModCon75 Controller
F8 Zone Control Cont. F6- will send all changes to
the X3 controller and also set the relays on the controller to activate
Locally based on set-point settings and relay numbers entered on the zone control menu
Response back for verification that all values were sent successfully
ESC-must hit escape to take one back to main screen
![Page 26: E VERY L IFE H AS A P URPOSE… ModCon ® 75 Controller.](https://reader030.fdocument.pub/reader030/viewer/2022032701/56649c7b5503460f9492f041/html5/thumbnails/26.jpg)
ModCon75 Event Logging
Event logging – Time date and stamp of all events (events are any fault alarms or alarms)
Logging will be done on any alarm and will continue to log at a preset rate until sensor goes out of alarm. Data logging is first in first out.
ModCon 75 can record ~2000 events.
Time / Date Stamp Zone # Unit # Sensor # Gas Type Gas Reading
Status
03/20/2006 12:01PM 01 01 3 LEL 10% Caution