POLATRAK TM DEEP-C-METER Mk.II WITH GRADIENT PROBE ROV MOUNTED SELF CONTAINED CP MEASUREMENT SYSTEM Operations & Maintenance Manual Revision 1.1 April 1998 Phone: (713) 983-7117 Fax: (713) 983-8858 Deepwater Corrosion Services Inc. www.stoprust.com 10851 Train Court Houston, TX 77041 HOME BACK FORWARD CONTACT US PRINTABLE VERSION

description

s

Transcript of Deep C Meter Operation Maintenance Manual

Page 1: Deep C Meter Operation Maintenance Manual

POLATRAKTM

DEEP-C-METER Mk.II WITH GRADIENT PROBE

ROV MOUNTED SELF CONTAINED CP MEASUREMENT SYSTEM

Operations & Maintenance Manual

Revision 1.1 April 1998

Phone: (713) 983-7117 Fax: (713) 983-8858

DDeeeeppwwaatteerr CCoorrrroossiioonn SSeerrvviicceess IInncc. www.stoprust.com

10851 Train Court Houston, TX 77041

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 2: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

2

TABLE OF CONTENTS

1.0 Overview 2.0 Parts & Specifications

3.0 Calibration

4.0 Operation 5.0 Maintenance & Repair 6.0 Troubleshooting

Attachment 1.0 Drawings

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 3: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

3

1.0 OVERVIEW

1.1 The Deep-C-Meter Mk.II is a complete ROV interfaced Cathodic Protection Monitoring System. The new model comprises of three basic parts; The Readout Unit, twin voltmeters housed in a stainless steel pressure housing. The Probe, a twin element, tip contact, CP probe (POLATRAK Model ROV III). The Flying Lead, a 2 meter long umbilical that connects the probe to the readout.

Figure 1.1 POLATRAKTM DEEP-C-METER Mk. II .

1.2 This new configuration offers a number of advantages over the Mk.1 instrument:

1.2.1 Easier to keep camera focused on readouts. 1.2.2 Easier to handle small probe in manipulator.

1.2.3 Probe can be wire into ROV umbilical if required for surface readout

and/or proximity measurement if required.

READOUT

ARTICULATED MOUNT

FLYING LEAD

PROBE UNIT

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 4: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

4

1.3 All the original innovative features of the Mk. 1 instrument are still included:

1.3.1 No interface required to ROV umbilical, unit operates independently of ROV power or communications.

1.3.2 Light activated power up. 1.3.3 Twin electrodes and readouts for on-line calibration.

1.3.4 3000 Meter (10,000 Feet) Depth rating.

1.3.5 6 Month operations from 2 alkaline batteries (9V).

1.3.6 Can still be used with POLASTAB Tip to read POLASTAB permanent

monitors

1.3.7 All parts are replaceable. 2.0 PARTS

2.1 An assembled section of the instrument is shown in Attachment 1. Mounts for the readout and the probe are omitted for clarity. The Readout Articulated Mount is shown in Figure 2.2 and the Probe Compliant Tee-Handle Mount is shown Figure 2.5. A parts list is shown in Table 2.1.

2.2 The major components along with specifications are described below: 2.3 Readout Unit

The readout unit has three major sub-assemblies: The Pressure Housing, the Connector Housing and the Articulated Mount.

2.3.1 Pressure Housing

2.3.1.1 Housing Body

The pressure housing is made from a single solid piece of 316L Stainless Steel and is rated for 3000 M (10,000 Feet) water depth.

2.3.1.2 Lens

One end of the housing contains an acrylic lens that seals with o-rings into the pressure housing. A 316L SS retaining ring and four SS screws keep the lens seated in the pressure housing. Access to the inside of the pressure housing is gained by pulling the lens. See maintenance and repair section for details on lens removal/replacement.

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 5: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

5

2.3.1.3 Bulkhead Connector

The back end of the pressure housing is sealed with an Impulse bulkhead connector. This connector threads into the back of the pressure housing and also seals with an o-ring. It should not be necessary to remove this connector during normal maintenance. A blank (dummy) connector is provided and should be in place whenever the mating connector is removed.

2.3.1.4 Voltmeter Module

The voltmeter module is housed within the pressure housing inside a shock absorbing / insulating holder (coozie). The voltmeter module contains two independent plug-in four-digit LCD readouts. Default factory range is +/- 2.000 VDC on both readouts. A 9V alkaline battery powers each readout. On the face of the module is a photocell that switches the unit on when exposed to light and a small jumper that switches the range of the either meter from +/- 2.000 VDC to +/- 200 mVDC. (This feature is used if reading monitors equipped with POLASTAB interfaces or the ROV III Gradient Probe). A desiccant pack is included to prevent interior fogging of the lens.

Figure 2.1 Voltmeter Module

2.3.2 Connector Housing

2.3.2.1 The Connector Housing is made from high impact natural

Delrin and is secured to the pressure housing with 4 stainless steel cap screws. The housing protects the cable connector and provides strain relief to the umbilical cable.

Displays

Photo Cells

Calibration Pots

Range Selector

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 6: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

6

2.3.2.2 The strain relief fitting is secured to the connector housing with

two stainless steel cap screws, it is necessary to remove this fitting before attempting to remove the housing from the pressure housing.

2.3.3 Articulated Mount

The Articulated mount is designed to secure the Readout to the ROV frame, and provides angled adjustment to optimize camera viewing of the displays. The mount and all fixing hardware are 316 stainless steel.

Figure 2.2 Articulated Readout Mount

2.3.3.1 Ensure that all fasteners are secure and all lock nuts and washers are in place before the ROV is deployed.

2.3 Probe Unit

The Deep-C-Meter Mk. II utilizes the popular POLATRAK ROV III Tip Contact Gradient Probe. This probe can be used independently of the readout unit as a standard topside wired CP probe. For reference the entire manual for this equipment is included as Attachment 1.0 to this manual. The Probe Unit comprises of the Nose Cone which houses the contact tip, the Main Two Compartment Body section, the Tail Unit which houses the reference electrode female plugs and the connection cable with strain relief, the Reference Electrode Elements, the Compliant Tee Handle Mount for manipulator mounting and the Flying Lead Connection back to the Readout Unit.

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 7: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

7

2.4.1 Nose Cone

The nose cone assembly is inserted into the main body section and is held in place with 2 set screws. The cone houses the replaceable contact tip, it also has the female connector that attaches to the male pin on the extension cable from the head unit. Tips are made from stainless steel; the nose cone is fabricated from black Delrin. The tip also has four water entry ports.

Figure 2.3 Nose Cone / Tip Unit Figure 2.4 Tail Unit

2.4.2 Main Body Section

The body section provides protection to the reference electrode elements. It is made from black Delrin and is designed to fit the compliant tee handle mount for convenient manipulator mounting.

2.4.3 Tail Unit

The tail unit attached to the main body section with 2 stainless steel cap screws. The connection cable passes through this unit and is strain relieved with a PVC strain relief fitting. One female electrode connector, one female connector for the extension cable to the electrode element in the nose compartment and one male tip connector are provided.

2.4.4 Reference Electrode Elements

Two plug-in sintered silver/silver chloride elements are included. Electrodes are accurate to +/- 5 mV. See the operations and maintenance section for instructions on electrode replacement.

CAUTION: NEVER HANDLE ELECTRODE ELEMENTS WITH BARE HANDS, or EXPOSE ELEMENTS TO ANY LIQUID OTHER THAN WATER. PERMANENT DAMAGE MAY RESULT.

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 8: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

8

2.4.5 Compliant Tee Handle Mount

The Tee Handle Mount allows easy interface with most manipulator systems. The entire mount is made from 316 stainless steel, the compliant elements are neoprene rubber. For convenience the handle orientation can be altered by 90 degrees.

Figure 2.5 – Compliant Tee Handle Mount

2.4.6 Flying Lead

The standard flying lead is 2 Meters long, a longer lead can be provided if it is necessary to use a rear facing camera to look at the Readout. The lead has a polyethylene abrasion resistant sheath and has connectors on either end that mate with the bulkhead connector on the Readout and the whip cable on the Probe unit.

2.5 Spare Parts & Accessories

2.5.1 The Deep-C-Meter is shipped in a waterproof case and should contain the following spares and accessories (see pictures on following page).

2.5.1.1 Desiccant Pack (2) 2.5.1.2 Zinc Calibration Block (1) 2.5.1.3 Contact Tips (3) 2.5.1.4 Connector Housing Screw (4) 2.5.1.5 Cable Strain Relief Screw (4) 2.5.1.6 Lens Retaining Ring Screw (4) 2.5.1.7 O-Ring Lube (1) 2.5.1.8 Silicone Connector Lube (1) 2.5.1.9 Bulkhead Connector Dummy Plug (1) 2.5.1.10 Ag/AgCl Electrode Element (1) 2.5.1.11 Lens Back-Up Ring (2) 2.5.1.12 Lens O-Ring (4)

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 9: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

9

2.5.1.13 Lens Puller (1)

1 11

10 9

87 65 4

3

2

12

13

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 10: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

10

POLATRAK DEEP-C-METER KIT

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

ROV II PROBE UNASSEMBLED (2) Ag/AgCl Refernce Electrodes Nose Cone Tail Unit

Page 11: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

11

Table 2.1

Part No. Description No. Required No. Spares DCM-010 Readout Pressure Housing 1 0

DCM-011 Readout Articulated Mount 1 0

DCM-020 Lens 1 0

DCM-011 Lens - O Ring 2 4

DCM-012 Lens - Backup Ring 1 2

DCM-021 Lens Retaining Ring 1 0

DCM-022 Lens Retaining Screw 4 4

DCM-023 Lens Cover 1 0

DCM-030 Bulkhead Male Connector 1 0

DCM-031 Bulkhead O Ring 1 0

DCM-032 Bulkhead Dummy Plug 1 0

DCM-110 Connector Housing Unit 1 0

DCM-111 ROV II Probe Nose Cone 1 0

DCM-112 Contact Tip 1 3

DCM-113 Connector Housing Retaining Screw 4 4

DCM-120 Main Connector 1 0

DCM-121 Replaceable Silver Chloride Element 2 1

DCM-210 Voltmeter Module 1 0

DCM-211 9V Alkaline Battery 2 0

DCM-212 LCD Display Module 2 0

DCM-214 Desiccant Pack 1 2

DCM-310 Compliant Probe Tee Handle Mount 1 0

DCM-410 Tube O-Ring Lubricant 1 0

DCM-411 Tube Silicone Grease 1 0

DCM-412 Zinc Calibration Block 1 0

DCM-413 Lens Puller 1 0

DCM-510 Instruction Manual 1 0

DCM-610 Transit Case 1 0

DCM-611 Transit Case O-Ring 1 0

DCM-612 Transit Case Foam Pack 1 0

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 12: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

12

3.0 Calibration

With the system hooked up, the probe should be bucket calibrated prior to deploying the ROV.

3.1 Bucket Calibration Procedure

1. Fill a non-metallic bucket or container with seawater, approximately 16 –18 inches deep.

2. Place the probe in the bucket with the tip pointing up to fill body with seawater. The entire probe, including tip must be immersed.

3. Stab the zinc coupon firmly onto the probe tip The upper displays on the readout unit should read between (+) 1.000 & (+) 1.100 Volts. The lower unit should read +/- 5 mV (+/- 50 on the display, the decimal point is not displayed.)

4. Note: If the probe has not been used in a while it may take 15-30 minutes for the probe to reach equilibrium.

3.2 Online Calibration

While free flying the upper meter is reading the potential of the tip contact, this number will vary. The lower meter displays the voltage gradient in the water. When remote from any structure, the meter should display +/- 5 mV (+/- 50 on the display)

If instrument will not calibrate go to Troubleshooting Section in this manual.

4.0 Operation

4.1 Mounting on ROV

Find a good location on the vehicle to mount the display unit, and attach the articulated mount. The lens on the unit must be camera visible and have a light source directed at it in order to activate the displays. Ensure that all fasteners are good and tight and that all lock nuts and washers are in place. Leave the lens cover in place while the unit is on deck (unless calibrating), the displays are light activated and battery life will be reduced. Insert the Probe unit into the compliant tee-handle probe mount and position in a manipulator, or tool basket that is manipulator accessible. It is a good idea to tie a safety lanyard to the probe mount u-bolts. Again, ensure that all fasteners are tight and lock nuts are in place. Route the flying lead in such a way that it will not be stressed, entangled or pinched during manipulator operation. Using the silicone grease provided, connect the flying lead to the probe and tighten the connector lock ring.

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 13: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

13

Perform Bucket Calibration (see section 3.0) Ensure that tip is tight in tip mount, and that tip is sharp. Remove the lens cover from the instrument. 4.2 Taking CP Potential Readings

Simply stab the tip contact probe onto the point on the structure where the reading is required, when a good contact is made the reading on upper meter will be steady. The lower meter should display a positive number when contacting an anode, and a negative number when contacting the structure remote from an anode. CAUTIONS

• Avoid stabbing painted or coated surfaces whenever possible, try to take readings on bare steel or on spots specially designated for CP measurement.

• Avoid trying to stab through heavy hard marine growth if possible.

• If the readings are not steady or don’t match the criteria in the table below, it’s probably due to a high resistance contact, DO NOT RECORD THESE NUMBERS continue to stab until readings are in specification. See troubleshooting section if problems persist.

• Never operate the system with any of the connectors un-mated unless the blanking plugs are installed.

4.3 Data Interpretation

Under normal conditions the readings obtained should be within the following ranges, exceptions may occur under the following circumstances:

• The probe is stabbed onto an isolated section of a corrosion resistant alloy, stainless steel, copper nickel etc. In these cases readings less negative than the indicated range may be noted. If this is the case ensure that the readings are steady and within the 5 mV allowable range.

• The structure under investigation is fitted with impressed

current cathodic protection. In this case, the readings may be more negative than those indicated below. Use the same procedure as above.

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 14: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

14

Normal Cathodic Protection Ranges in Seawater Range Interpretation

<(-)0.500 Probable Error (-)0.500 – (-)0.650 Native state potential, no CP applied. (-)0.650 – (-)0.800 Under-Protected (-)0.800 – (-)0.850 Marginal Protection (-)0.850 – (-)1.050 Optimal Protection (-)1.050 – (-)1.150 Galvanic Anode Potential >(-)1.150 Probable Error – Check Contact Note: Upper meter displays the potential with polarity reversed.

4.4 Removal from ROV

When equipment is removed from ROV hose down thoroughly with fresh water and allow to dry. Replace lens cover and return to storage case provided.

5.0 Mainenance & Repair This section covers general operational maintenance, do not attempt any tasks not described in this section as it may damage the system. 5.1 Tip Replacement From time to time it will be necessary to replace tips. Remove old tip with a wrench (flats are provided). Ensure that new tip is tight. 5.2 Electrode Element Replacement

• Remove the probe from the ROV and un-mate the connector. Install the blank plug provided onto the exposed flying lead connector. Next determine which element is bad.

• Put the probe into a bucket and stab the zinc coupon as described in section

3.0.

• Using a digital voltmeter set on 2.00 VDC range stab the large pin with the positive voltmeter lead, and pin 1 (first clockwise of large pin) with the negative lead (note reading). Then repeat stabbing pin 2 with the negative lead, note the reading. The faulty electrode will be the one that gives the lowest (least negative) reading.

• Ensure that probe is drained of seawater.

• Take probe unit to a clean area. Do not handle the small electrode pellets

with bare hands.

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 15: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

15

• Remove the two screws securing the tail unit and gently pull out the tail unit

exposing the electrode elements. Try to avoid un-mating the tip connector. • Loosen the set screws and remove the nose cone. • Verify which electrode is bad using the Ohms setting on the multimeter. • Visually inspect to ensure that the wire is not damaged or the connector

improperly mated. • Remove the bad electrode and discard. • Take the new electrode and carefully place a small amount of silicone grease

on the pin and sealing section of the connector. Plug the new electrode into the connector.

• Check that all connectors are fully mated, then carefully put the electrodes

back into the housing and re-attach the tail unit and nose cone. • Repeat calibration as described above. (Note a new dry element may take

up to 30 minutes to reach equilibrium)

NEVER IMMERSE AN ELECTRODE ELEMENT IN WATER WITH THE CONNECTOR PIN EXPOSED.

5.3 Battery Replacement

Batteries will need replacing only after 4-6 months of operation. In order to replace batteries, the readout must be removed from the vehicle and taken to a clean dry location. This is best done in a workshop.

Follow these steps: 1. Remove the lens retaining ring.

2. Install the lens puller into the lowest exposed groove on the lens as shown below:

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 16: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

16

3. Tighten down on the four screws one turn at a time until the lens can be easily pulled from the housing. Remove the lens.

4. Carefully remove the voltmeter module from the housing, there is enough slack cable to allow this. Then pull back the foam to expose the two batteries. 5. Replace the batteries with new ones, also replace the desiccant bag.

6. Carefully re-insert the voltmeter module. The displays should illuminate. 7. Remove and discard the O-Rings and Back-up ring from the lens, and replace with the spares provided. Ensure that the back-up ring goes under the o-ring in the correct groove with the concave side facing out. Use the lubricant provided and coat the sealing surfaces with a thin layer. 8. Insert the lens into the housing so that the first o-ring is just above the housing. Install the lens-retaining ring and engage screws. Tighten screws one turn each on opposing screws until both rings are fully inside pressure housing.

HOME ◄ BACK FORWARD ► CONTACT US PRINTABLE VERSION

Page 17: Deep C Meter Operation Maintenance Manual

DEEPWATER CORROSION SERVICES, INC. DEEP C METER MANUAL

17

6.0 Troubleshooting Symptom Possible Problem Action Instrument will not calibrate One electrode is bad

Zinc Coupon is passive Electrodes are dry

See Section 5.3 Remove zinc and clean with rasp Allow to soak for 30 minutes and retry

Both electrodes reading low Tip wire damaged Remove probe tail unit, unplug tip wire, remove nose cone, inspect tip wire and repair with ScotchKote as temporary measure. Order replacement nose cone.

Readings are not steady, they continue to change.

Batteries are low Poor structure contact

Replace batteries Re-stab to ensure contact.

One reading suddenly goes less negative

Connector is flooded Lead wire (Flying lead) is nicked.

Check Connectors Inspect and repair / replace as necessary

Displays are blank Not enough light to photo-cells Batteries are dead

Increase light intensity and re-direct to center of lens. Replace batteries

For any problem not described here call our Technical Hotline(s) (713) 983 7117 x 225 or x 224 (281) 744-2342 (After Hours) Leave message if no answer.