Compact NSXIntegrating power managementand superior protection
Superior protection
Precise measurement
Simple communication
Power management
Easy maintenance
Schneider Electric (HK) Ltd.
()
As standards, specications anddesigns change rom time to time,please ask or conrmation o the
inormation given in this publication.
Macau Branch Oce Suite D, 13th Floor, The Macau Square,Avenida do Inante D. Henrique, No. 47-53, Macau47-5313DTel (853)2871 7488Fax (853)2871 7499
13th Floor, East Wing, Warwick House, Taikoo Place,979 Kings Road, Quarry Bay, Hong Kong 97913Tel(852)2565 0621 Fax (852)2811 1029Customer Care Centre (852)2579 9699www.schneider-electric.com.hk
SEHK/DOC/MCCB22 10/2009
Overview of brand new Micrologic tripping unitsMicrologic
Micrologic 2Electronic tripping unit
Distribution protection Generators protection Motors protection
Micrologic 5/6A or EElectronic tripping unit
5A or E Distribution protection
6A or E Distribution protection 6E-M Motors protection
A: current metering unctions E: A+current and energy metering unctions A+
2.2 Distribution protection 2.2-G Generators protection 2.2-M Motors protection
5.2A Distribution protection 5.2E Distribution protection 6.2A Distribution protection 6.2E Distribution protection
6.2 E-M Motors protection
2.3 Distribution protection 1.3-M Motors protection 2.3-M Motors protection
5.3A Distribution protection 5.3E Distribution protection 6.3A Distribution protection 6.3E Distribution protection
6.3 E-M Motors protection
Adjustment and readingPick-up set in amps with neadjustment using dials
Fine adjustment via keypad
LED indicationsLED
Connected to switchboarddisplay unitRJ45
Compact NSX100 has Micrologic tripping unit, which canimprove discrimination with the Multi 9 miniature circuitbreakers (40A). Improved discrimination can be ensuredand the project cost lowered.MicrologicCompact NSX10040AMulti 9DiscriminationDiscrimination
NSX250NS400
NS160(100 A) NSX100
Multi 9 MCB (40A)
NSX100 - 250
NSX400 - 630
Multi 9 MCB (40A)
-
7/28/2019 Compact NSX Leaflet MCCB22
2/2
Multi-unctional electrical parameter measurements
Built-in double sensors patented
technologyDouble sensors patented technology
iron sensor: or reliable power supply to the
electronics
air sensor: or accurate measurement o
electrical parameters
Circuit breaker as a multi-unctional meter
Execute measuring unction without additional
sensor
More accurate measurement, more precise
protection
Simpliy the number o components in the
switchboard
Simple and fexible solution o Compact NSX communication throughout electrial distri bution and communication network.
Compact NSX
Ethernet (TPC/IP/modbus)
MPS100
Internet
ModbusModbus
FDM121
Sepam PM710Compact NSX
Firewall
Offline mode
Software Supports RSU, RCURSU, RCU
ModbusInterface Module
MasterpactInterface module via COM
COM
>
>
>
>
>
Compact NSX measurement and
display unction
Advanced electronic trip units for communication
and measurement
Simple design, electrical build-in sensors or
measurement
LCD display equipped on tripping unit
Advanced Micrologic Type A or current-
related measurements
Advanced Micrologic Type E or energy-
related measurements such as current,
voltage, power rating, requency, power
usage and harmonics, etc.
Direct access to data through the screen o
tripping unit or FDM121 switchboard display
unit
Direct access to various parameters without
opening the door o the switchboard
Local and remote displays oer easy access
to operators
The user-riendly switchboard display unit
with intuitive navigation oers quick access
to inormation
The switchboard plug & play display unit
connects to the trip unit without any special
settings or conguration. A cable tted with an
RJ45 connector allows easy integration with
communications networking
>
>
>
>
>
>
>
>
>
>
>
>
>
Compact NSX
A
E
FDM121
RJ45
>
>
>
>
>
>
>
>
Simple communication system
RJ45Modbus
Compact NSX
ModbusCompact NSX
/
I U f P E THD
Easy and fexible architectureThe connection o an RJ45 connector with the
Modbus interace module allows all Compact NSX
circuit breakers to communication unctions. When
the Modbus address is declared, the Compact NSX
device is integrated into the network.
4 levels o communication unctionalities can be
chosen based on users applications:
Communication o device status: On/O
position, trip indication and ault-trip indication
Communication o commands: open, close, and
reset
Communication o measurements: I, U, , P, E
and THD
Communication o operating assistance data:
settings, parameters, alarms, time-stamped
histories and event tables, and maintenance
indicators
Communication system solution
Compact NSX measurement application solutions
Gateway
Main circuit: Type E tripping unit + FDM121 display unit
E + FDM121
Standard circuit: Type A tripping unit
A