Bologna sies 2011
-
Upload
voixup -
Category
Health & Medicine
-
view
373 -
download
0
Transcript of Bologna sies 2011
![Page 1: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/1.jpg)
MLC IPODERMICA CON CANNULA FREDDANEL TRATTAMENTO DELLE A.L.
Dott.Stefano Toschi
U.O. Chirurgia Plastica Ospedale
dell’Angelo MestreCoordinatore Veneto Aidme
14° CONGRESSO
INTERNAZIONALE SIES BOLOGNA 2011
![Page 2: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/2.jpg)
LIPOEMULSIONE
• Una procedura in grado di indurrefenomeni di adipocitolisi conliberazione del grasso intracellulareche viene successivamente eliminatodall'organismo attraverso i sistemilinfatico venoso ed immunitario
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 3: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/3.jpg)
CHIMICA
• Infiltrazione difosfolipidi• Infiltrazione di
soluzioni detergenti
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 4: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/4.jpg)
FISICA
LaserlipolisiCarbossiterapia
CavitazioneTransderm
Microlipocavitazione
RF
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 5: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/5.jpg)
ULTRASUONI
• Onde di energia > 20KHz che inpresenza di un mezzo solido liquido ogassoso vengono trasmesse da unamolecola all’altra• A parità di cicli di lunghezza d’onda gliUS a bassa frequenza penetrano piùin profondità di quelli ad altafrequenza
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 6: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/6.jpg)
UAL
• Le onde US si trasmettono facilmenteattraverso i parenchimi molli• Nel 1987 la tecnologia US è statausata per la prima volta per creareemulsione del tessuto adiposo inassociazione alla liposuzione (UAL)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 7: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/7.jpg)
EFFETTI DEGLI US
•Meccanico (rottura membrana)•Termico (denaturaz,lipasi)•Chimico (pH,permeab.membr.)•Cavitazionale
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 8: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/8.jpg)
• fenomeno fisico per il quale un’onda elasticapropagandosi nei tessuti e nei fluidiextracellulari provoca una depressionerepentina di valore tale da scendere sottola tensione dei gas disciolti. Si creanopertanto microbolle che nel ciclo successivo,caratterizzato da aumento di pressione,implodono cedendo la loro energia allemembrane cellulari degli adipociti consuccessiva adipocitolisi
CAVITAZIONE
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 9: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/9.jpg)
TIPI
• TRANSDERMICA • SOTTOCUTANEA
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 10: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/10.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 11: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/11.jpg)
• Generatore di cavitazionemultifrequenza a freddo dotato dicannula di 2mm di diametro da140/180 mm di lunghezza
• Capacità di concentrare l’energiaprodotta dagli US (37.2/42.2 KHz)elettivamente sull’ estremità dellacannula riducendo drasticamente irischi di danno termico
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 12: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/12.jpg)
POTENZA
•US esterni 2,5 W/cm²•Microlipo 19-21W/cm² • La cannula è in grado di lavorareanche al 100% di potenza senzasurriscaldarsi
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 13: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/13.jpg)
CANNULA FREDDA
• il dispositivo cavitazionale non èallocato sulla cannula ma all'estremitàdel manipolo in modo da non causaredanno termico nè alla cute circostantei fori d'ingresso nè all'area adiposatrattata (25°C a livello della punta).
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 14: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/14.jpg)
ONDA ULTRASONICA
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 15: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/15.jpg)
FOCALIZZAZIONE
• US non focalizzati con maggiore areadi distribuzione dell’onda nel TA
• Focalizzazione non necessaria inquanto l’energia non viene dispersa datessuti interposti
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 16: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/16.jpg)
MECCANISMO D’AZIONE
• L’osservazione al M.E. dimostra che iltrattamento induce una drasticariduzione nella compattezza del TAconnettivale con formazione di ampielacune nelle bande di fibre collagene
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 17: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/17.jpg)
FREQUENZE
• ricerca automatica della frequenza dilavoro per ogni singola cannula (testfrequency) e test automatico dellafrequenza operativa ripetuto ogni 5sec. durante l’uso per ottimizzare lapotenza ed evitare il surriscaldamento
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 18: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/18.jpg)
SOFT SWITCH ON/OFF
• selettività in tempo reale conriconoscimento della consistenza deitessuti attraversati quando siincontrano strutture organiche(vascolari ecc) diverse dal tessutoadiposo.
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 19: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/19.jpg)
AUTODIAGNOSTICA
• Prevenzione di eventuali microfratturedella cannula . Presenza di allarmeper malfunzionamento .
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 20: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/20.jpg)
BIOCOMPATIBILITA’
• i materiali usati per le cannule sono abase di Titanio che per le suecaratteristiche strutturali veicola inmodo ottimale gli ultrasuoni
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 21: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/21.jpg)
UPGRADING
• il generatore di US ha incorporato unafunzione pulsata per il trattamentodelle aree lipodistrofiche ed e’ in fasedi sperimentazione per altre funzioni(scollamento tissutale).
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 22: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/22.jpg)
nelle vie di accesso al tessuto adiposoin quanto le incisioni per consentire l'ingresso della cannula sono didiametro molto contenuto (1,5 – 2mm).
MINIMA INVASIVITA’
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 23: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/23.jpg)
KIT PER MLC
• Siringhe da 2,5 10 e 50cc• Disinfettante• Guanti Garze e Teli sterili• SF Lidocaina Adrenalina Bicarbonato• Ciotola• Bisturi lama n.11• Kit Microlipo (Manipolo e Cannule)• Steristrips e Cerotti Medicati
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 24: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/24.jpg)
PRE TRATTAMENTO
•Consenso informato•Foto•Disegno aree da trattare•Misurazioni circonferenze•Accensione apparecchio
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 25: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/25.jpg)
PREPARAZIONE APPARECCHIO
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 26: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/26.jpg)
PREPARAZIONE PAZIENTE
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 27: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/27.jpg)
ANESTESIA
• FISIOLOGICA 500 cc• LIDOCAINA 2% 30 meq• ADRENALINA 1% ¼ fl• BICARBONATO 2 ml • Infiltrazione con cannula attraverso lapiccola incisione praticata
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 28: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/28.jpg)
EMULSIONE
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 29: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/29.jpg)
MEDICAZIONE
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 30: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/30.jpg)
COMPRESSIONE
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 31: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/31.jpg)
AREE TRATTABILI• Addome/Fianchi• Trocantere/Coscia int/Regione sottoglutea• Ginocchia• Polpacci e caviglie• Mento• Mammella maschile• Dorso• Lipomi• Lipodistrofie
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 32: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/32.jpg)
PAZIENTI NON TRATTABILI
• Pz affetti da gravi patologie attive di tipovascolare o cardiaco
• Pz portatori di pacemaker• Pz in terapia con farmaci antitumorali e
antirigetto o cortisonici• Grandi fumatori• Gravidanza/Allattamento• Dismorfofobici/A tendenza isterica• Aspettative eccessive 14° CONGRESSO
INTERNAZIONALE SIES BOLOGNA 2011
![Page 33: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/33.jpg)
PROTOCOLLO• 1-2 aree per seduta• Infiltrazione media 100/150 cc perseduta per area
• Cavitazione media 10 min per area• Aspirazione max 1/3 dell’emulsione• Compressione con guaine o calze 140denari per 15 gg
• Ripetibilità nella stessa area dopo 30giorni
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 34: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/34.jpg)
LOCALI•Edema•Dolore•Ecchimosi•NON Iperpigmentazionio teleangectasie dasurriscaldamento
SISTEMICINon descritti
EFFETTI COLLATERALI
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 35: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/35.jpg)
RISULTATI
• Richiedono 8-12 settimane permanifestarsi completamente
• È consigliato precoce esercizio fisico• Successive sedute di cavitazioneesterna determinano una più rapidascomparsa dell’edema
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 36: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/36.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 37: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/37.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 38: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/38.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 39: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/39.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 40: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/40.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 41: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/41.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 42: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/42.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 43: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/43.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 44: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/44.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 45: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/45.jpg)
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 46: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/46.jpg)
EFFICACIA
• Sperimentalmente su campioni ex vivodi TA la perdita di peso è giàevidente dopo 20 min ma èparticolarmente alta dopo 18 H• Pertanto l’azione degli US continuaanche dopo la fine del trattamento
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 47: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/47.jpg)
EFFETTO MECCANICO ?
• Spegnendo l’ultrasuono la riduzione divolume del campione è modesta (< 3%)• Inoltre la quota di colesterolo e TG èaumentata dimostrando la presenza diun’azione adipocitolitica che peraltronon modifica la struttura cellulare didetti lipidi
14° CONGRESSO
INTERNAZIONALE SIES BOLOGNA 2011
![Page 48: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/48.jpg)
ASPETTI MEDICO-LEGALI
•Dispositivo medico attivo diclasse IIb (93/42 Cee)•Utilizzable in locali adibiti aduso medico di gruppo 1 osuperiore (Cei 64-8/710)•Classe di protezione 1 tipo b
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 49: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/49.jpg)
INDICAZIONI
•Aree di trattamento localizzate•Controindicazioni alla liposuzione•Esiti di liposuzione• Lipodistrofie anche post anti-HIV•Eta’ avanzata•Compliance del pz.
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 50: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/50.jpg)
EFFETTO LIFTING
•Significativo miglioramento dellatexture dei tessuti trattati con
aumentata produzione di ffcollagene•Effetto termico ?• In corso studio di valutazione
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 51: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/51.jpg)
VANTAGGI
Curva di apprendimento breveTrattamento AmbulatorialeSelettività TissutaleCannula fredda NO DANNO TERMICORipetibilità in tempi breviTrattamento aree con setti fibrosiCompliance
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011
![Page 52: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/52.jpg)
CONCLUSIONI
• 1) è selettiva e circoscritta all’area sede del flussoenergetico,
• 2) è in grado di determinare una progressiva riduzione deltessuto adiposo immediata e differita
• 3) non compromette la rete vascolare adiacente al campo diazione,
• 4) evoca la liberazione di trigliceridi e colesterolo in formaproporzionale alla durata del trattamento,ma comunque al disotto delle normali capacità di metabolizzazionedell’organismo
• 5) ha una valenza terapeutica significativamente potenziatadall’infiltrazione locale di soluzione fisiologica erogata con iprincipi della “lipoaspirazione tumescente”.
14° CONGRESSO
INTERNAZIONALE SIES BOLOGNA 2011
![Page 53: Bologna sies 2011](https://reader031.fdocument.pub/reader031/viewer/2022020218/55c31b73bb61ebdd288b464b/html5/thumbnails/53.jpg)
GRAZIE
14° CONGRESSOINTERNAZIONALE SIES
BOLOGNA 2011