Bai Giang Thuc Hanh Mon Dien Co Ban 9748

download Bai Giang Thuc Hanh Mon Dien Co Ban 9748

of 36

Transcript of Bai Giang Thuc Hanh Mon Dien Co Ban 9748

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    1/36

    Company

    LOGO

    electrical - electronic

    Electronic Report of Basic Subjects

    Group 2

    Students:

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    2/36

    Content

    I.The Electric Map and

    Circuits on family

    III. Motor 3 phase and motor 1 phase

    VI.Control circuit

    II. Power supply cord connection and

    V.O.M

    V.Measurement And Control Fan

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    3/36

    I.The Electric Map

    1.Layout diagram

    1.Layout diagram 2.Schematic diagram

    2.Schematic diagram 3.Wiring Diagram

    3.Wiring Diagram

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    4/36

    1.Layout diagram

    Funtion:Locate loads

    KWh

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    5/36

    2.Schematic diagram

    Includes circuit:- Three Phase Transformer

    6KVA/0.38KV- Single phase electric meters- CB- 2 Fuses- 2 Switch- 2 Light,2 socket (10A,20A)

    6KV 0,38KV

    10KVA3 4

    KWh

    KWh

    CB 30A

    R

    R

    R

    R

    R

    K1

    K2

    K3

    10A

    20A

    1~40

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    6/36

    3.Wiring Diagram

    6KV/ 0,38KV

    10A 20A

    KWh

    1~40

    - 4 light

    - 2 switch

    - 2 socket

    - Single phase electric meters

    - 5 Fuse

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    7/36

    - System have wire mass

    - Wire on plastic pipe

    - Socket distance land 1.3m

    - Pile resistance < or = 4 om

    Note

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    8/36

    Circuits on family

    Includes circuit:

    - 1 light

    -1 switch

    -2 socket

    - 1 Fuses

    - CB

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    9/36

    Includes circuit:

    - 1 light

    -1 switch

    - 1 Fuses

    - CB

    -Socket

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    10/36

    II. Power supply cord connection and V.O.M

    1.Power supply cord connection

    a. direct connection (communication connection head)- Crossed the wire 2 A and B (already broaching the shell and cleaned)

    should join together

    - A wire wound on the body B (close to around 10 rounds each)

    - B winding wire on the body A (close to each other about 10 rounds)

    Use pliers to tighten connections.

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    11/36

    b. Branch connections (T-connector):

    - Place the wire A wire is perpendicular to the body B (the shell hasbeen grooming and cleaning).

    - Wrap the wire A wire around the body behind the head string B of A,

    the first wire wrap

    - A round wire A to the front lines A and B wire wound on the body

    for about 7 to

    10 ring-side.

    - Use pliers to tighten connections again

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    12/36

    c. Lead solder- Plug the burner to reach maximum temperature.

    - Clean the surface with sandpaper connection.

    - Resin dots on the burner (the burner cleaned by acid in the resin).

    - Place the burner at an angle of 45 joints dovoi about 3 to 5 minutes

    (depending on the type of burner 40W or 60W) for connection to heat up.

    - How to put lead solder burner 1 to 2 mm for lead free flowing around thejoints.

    - Connect the burner to reach maximum temperature.

    - Rats need to shell the string si.

    - Clean the surface of the wire.

    - Resin dots on the burner (the burner cleaned by acid in the resin).

    - Place the burner at an angle of 45 dovoi the wire about 3 to 5 minutes

    (depending on the type of burner 40W or 60W) for the wire to heat up.

    - How to put lead solder burner 1 to 2 mm for lead free flowing around the

    wire.

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    13/36

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    14/36

    2. VOM- Meters VOM meter is called universal because it does much

    use.

    - VOM meter can measure currents, voltages, resistance. In addition, the

    - VOM can be used for Testing Transistor, determine the polarity of the

    diode ...

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    15/36

    -Elevator (A): Calibration for Ohm (-0 from right to left as the -).- Elevator (B) and (C) dividing the Volt, Ampere DC, AC

    (DC.VA & AC.V) left to right, the maximum number of 0.

    - Scale (D) read Trasistor amplification factor (HFE = Ic / Ib).- Elevator (E) and uterus (F): read current polarization upon or against

    (leakage) of

    Diode.- Scale (G): one is to read the leaked ICEO of transistors

    ** Practices

    1.Voltage measurements:

    - When you want to measure voltage alternating current (AC) or DC

    (DC), we adjust

    switch on the meter of the measuring period is denoted AC.V or DC.V

    - Select appropriate measurement period (larger) with a voltage to be

    measured.

    - Install parallel to the clock source to be measured.

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    16/36

    -Read the voltage value measured on this scale.

    + 10 volt scale: each bar is 0.2 units.

    + 50 volt scale: each bar unit LA1.

    + 250 volt scale: each bar is 5 units.

    For example: choose period, we measured 250 index on the scale read 250

    AC.V.

    Note: - When measuring AC voltage, attention select appropriatemeasurement range, avoiding- choose smaller voltage range to be measured or choose another

    measurement range

    voltage measurement.2. DC current measurement:

    -- When you want to measure DC DC (DC), we adjust the switch onclock period of measurement is denoted DC.mA

    - Select the period to match the measured current to be measured.

    - Install with the serial clock source to be measured.

    - Read the voltage value measured on the scale corresponds to the range

    measured.

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    17/36

    3. Testers- When you want to measure the electrical resistance R, we adjust the

    switch on the measuring range is denoted

    .

    - Choose a suitable measuring range resistor to be measured.

    - Chap 2 measuring stick together and adjust the knob for the needle 0

    standards.- Put the rod 2 measured in the first two resistors to be measured.

    - Read the index measured on the scale corresponds to the range

    measured.

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    18/36

    III Motor 3 phase and motor 1 phase

    1. Testers heat engine

    Step 1: Measure R insulation (check for shells being touched or not)> 1 mg

    - If the first measure in turn the AX, BY, CZ with shell insulation resistance> 1 mg

    shall meet the requirements => do not touch the shell => machine operating

    conditions

    Step 2: Measure R (coil resistance) AX, BY, CZ are equal

    - Measure the pairs AX and determine the resistance of the coil day.Sau it shall bethe same for the pair BY, CZ

    - Case 1:

    1. Voltage coil 3 is measured at several volts, the coil (I, II) will have the

    following: A_X_B_Y

    2.Neu measuring coil 3 is the U = 0V (X_Y) first rolled coil connecting the 2nd

    strategy was as follows: A_X_Y_B-Case 2: After measuring the change determined before the 3rd roll to roll 1 or roll

    2 rolls to determine the remainder of the 3rd roll

    * Experimental:

    Scroll I: 1-4

    Scroll II :2-5

    Scroll III :3-6

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    19/36

    U = 0vV

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    20/36

    2.3-phase motor conector

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    21/36

    Motor 3 phase Xung shun

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    22/36

    Picture of motor 3 phase

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    23/36

    Y 900

    A 1050

    E 1200

    B 1300

    F 1550

    H 1800

    C >1800

    *INS:insclass

    *S.F: service factor

    *Frame:- structural parameters, such

    as structure height of the motor shaft

    from the floor, the distance of the axisof the fixed point the base installation.

    - example:Engine Frame: 215, then

    we get the first two numbers divided 4

    so 5 * 1 / 4, this is the height of the

    shaft from the floor and 5 are set

    distance from a fixed point on the axis

    of the base (inch )

    * U1U2=W1W2=V1V2

    *

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    24/36

    3. 1-phase phase motor conector

    S. W : stort winding

    R. W: run winding

    RR. W > RS. W

    Experimental: RR. W = 50V, RS. W =20V

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    25/36

    Picture of motor 1 phase

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    26/36

    VI. Control circuit

    1. Components in control circuits

    a.CB

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    27/36

    b.Contactor

    NC(normally closed):0

    NO(normally opened):

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    28/36

    c.Thermal relay

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    29/36

    d. Time relay

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    30/36

    2.Control Circuit

    a. Jumpstart circuit Direct Engine 3 Phase Asynchronous

    Step 1: Close CB

    Step 2: Press FOR

    Step 3: Test Machine Runs And then OFF Press

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    31/36

    b. Boot directly Asynchronous Motor 3 Phase reversal Back

    Step 1: Close CB

    Step 2: Press FOR

    Step 3: Press OFF and note direction of rotation of

    the engine REV Then click Back to make

    comparison engine => press OFF to stop engine

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    32/36

    c. Motor starter circuit / of asynchronous three-phase relay time

    Step 1:close CB

    Step 2: Adjustment time relay 3 to 5 seconds

    Step 3:press FOR after 3 seconds of the transfer

    Step 4: press OFF

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    33/36

    d. Change Speed circuit 3-phase motor

    Step 1:close CB

    Step 2: press FOR

    Step 3: Mt press, engine performance at low speeds,

    the stator windings of the motor's auction

    Step 4: Mc Press, engine performance at high

    speeds, the stator windings of the motor's auction=> Press OFF to stop engine

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    34/36

    Requirements:

    - determine the correct position of the Closing Next, Open Your Contactor,

    Thermal relay, buttons

    - Check Point Next Good Or Not There

    - Connect the wires in place

    - Electrical Inspection Before Closing

    - Connect and notice how

    - Control relay time

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    35/36

  • 7/31/2019 Bai Giang Thuc Hanh Mon Dien Co Ban 9748

    36/36

    V. Measurement And Control Fan

    1. Map here of a Phase Electric Fan

    Requirements: - Determine the wire- Investment in Title Roll

    - Fan runs

    Step 1: Wire played by 2 first, determine R4-R5 = Rmax

    Step 2: 3 wire connection head left and measurement with R4, R5

    will determine R4, R5 (R5> R4)

    Step 3:Measure R4 top line top line with 3 remaining, define R1, R2, R3 (R1 >R2 >R3 )

    The End