Approved for Construction BPS.15-21145.CO M.CNEW...

1
A300 1 A301 2 A 301 1 1 A400 2 A400 1 A401 2 A401 STAIR 2 S2-200 STAIR 1 S1-200 WD 1 A501 CORRIDOR C200 A613 1 2 A501 1 A502 1 A507 3 A503 A612 1 A561 1 A561 4 1 A505 2 A506 A300 2 3 A504 3 A501 A301 4 2 A505 2 A504 A602 1 A615 1 3 A505 A614 1 ELECT E200 TRASH TR200 TRASH TR201 TR200 E200 AMENITY A200 A200B STORAGE S201 2 A502 1 A503 2 A503 1 A504 1 A506 3 A506 3 A502 A301 3 3 A550 2 A550 ELEV LOBBY L200 3 A507 ELEV. 1 E1-200 A651 3 1 BR 200 STUDIO 202 1 BR 204 1 BR 206 1 BR 208 2 BR 210 3 BR 211 1 BR 209 2 BR 207 2 BR 205 3 BR 201 17 16 15 14 13 13 10 8 6 5 5 4 3 2 B C D G J H E 7 12 K K 11.8 A620 K7 A200C A I 4 A551 3'-4" 2 A507 A652 2 4 A507 8'-0 1/4" 7'-3 1/8" TOILET A200A A200A 5'-3 1/2" 5'-0" 8'-2 1/4" 8'-0" 5'-0" 3'-10" 10'-10" 5'-0" 12'-2" 10'-8 7/8" 5'-0" 12'-3 1/8" 10'-8 7/8" 5'-0" 21'-6 3/8" 5'-0" 7'-1 3/4" 6'-10" 10'-6 1/4" 2'-10" 41'-2" 21'-8" 11'-0" 8'-8" 7'-4" 2'-0" 12'-0" 10'-4" 14'-0" 14'-6" 6'-6" 6'-8" 2'-8" 4'-0" 55'-11 1/8" 57'-2" 64'-0" 12'-3" 32'-8" 12'-3" 11'-0" 10'-8" 11'-0" 5'-0" 5'-2" 6'-4" 5'-3 3/8" 1 '-8" 92 .00° 2'-10" 5 1/4" 2'-10" 25'-0" 9'-4 1/2" 12'-0" 10'-8 1/8" 1'-3 7/8" WD WD 6'-11 1/4" 10 3/8" 2'-0" 101'-2" 1'-0" 6'-8" 1'-0" 1'-9" 13'-8 3/4" 20'-2 1/2" 1'-9 3/8" 5'-8" 10" 5'-6" 10" 2'-6" 12'-4 1/4" 12'-3 3/8" 5'-0" 24'-8" 24'-8" 5'-0" 12'-3 3/8" 21'-2 1/4" 10'-8 7/8" 5'-0" 11'-3" 10'-3 3/8" 5'-6 3/8" -1'-0" WC WC WS WS 3D WD 3C 3C WC WC WC 11H WD WD WC WD WD WD WC WC WD WD WD WD WD WD WC 102'-4 3/8" 9 ' - 4 " 1 5 ' - 9 7 / 8 " 1 1 ' - 2 7 / 8 " 9 ' - 9 1 / 2 " A561 1 A200 STORAGE S202 S202 S201 A561 1 SIM. 6'-3 1/2" BALCONY SEE DETAIL: 1 /A551 11'-9" 11'-8" BALCONY SEE DETAIL: 2/A551 BALCONY SEE DETAIL: 6/A553 SIMILAR BALCONY SEE DETAIL: 8/A553 SIMILAR BALCONY SEE DETAIL: 2/A551 SIMILAR BALCONY SEE DETAIL: 2/A551 SIMILAR SHAFT ACCESS PANEL- ALL LEVELS SHAFT ACCESS PANEL-ALL LEVELS SHAFT ACCESS PANEL- ALL LEVELS A620 I4 4 A501 4 A501 6'-3 1/2" 6'-0 1/4" 2 A551 BALCONY 1 BALCONY 2 BALCONY 3 BALCONY 4 BALCONY 5 BALCONY 6 BALCONY 7 BALCONY 8 BALCONY 9 BALCONY 10 BALCONY 11 1 1 1 1 1 1 1 1 1 1 1 10 A170 8 A170 3 A170 AW1 4 4 4 4 4 4 AW9 13'-7 7/8" 1'-0" 13'-0 1/2" 5'-4" 11'-3 1/4" 14'-4" 6'-0" 13'-1 3/4" 8'-7 1/4" 8'-0" 20'-0" 8'-0" 9'-4 1/2" 13'-8 1/4" 11'-6 1/4" 6'-0 1/8" 19'-7 7/8" 1 9 A170 A301 5 A301 6 2'-0" 1'-10 7/8" TR201 WS 1'-4 3/4" 7'-4 7/8" 6'-0" 10" SHAFT ACCESS PANEL- ALL LEVELS 5 4'-3 1/4" 5'-9 1/4" 10" 8'-2" 5'-2 7/8" 1'-4 3/8" 2'-0" 3'-6" 2'-9" 4'-11 3/8" 8" 3'-7 3/8" 6'-10 1/2" 3'-0" WC WC 5 10" WS WS WS WC WC G003 1 S1-200 WST WST SIM. 8'-8" 1'-0" 1'-0" 11 A170 12 A170 A119 1 2 '-5 7/ 8" 1'-5 3/4" 3'-3 1/2" 13 GENERAL NOTES - FLOOR PLAN ALL DIMENSIONS ARE TO FACE OF WALL (UNLESS NOTED OTHERWISE). SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STEEL REINFORCING IN WALL & FLOOR CONSTRUCTION. SEE FINISH SCHEDULE FOR ADDITIONAL INFORMATION OF LOCATIONS AND TYPES OF FINISH MATERIALS. SEE ELEVATIONS AND STRUCTURAL DRAWINGS FOR LOCATIONS OF EXPANSION & CONTROL JOINTS. CONTRACTOR SHALL PROVIDE ADDITIONAL INTERIOR CONTROL JOINTS AS REQUIRED TO COMPLY WITH MAXIMUM SPACING REQUIREMENTS IN SPECIFICATIONS AND NATIONAL MASONRY INSTITUTE. SEE DETAILS ON AXXX. MECHANICAL & ELECTRICAL EQUIPMENT SHALL BE ON HOUSEKEEPING PADS. PADS ARE TO PROVIDED BY THE TRADE SUPPLYING THE EQUIPMENT. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. WORK TO BE COORDINATED THROUGH THE GENERAL TRADES CONTRACTOR. PADS 4" MIN. 4" THICK W/ W.W.F., UNLESS NOTED OTHERWISE). SEE G SERIES SHEETS FOR WALL TYPE CONSTRUCTION. PROVIDE AN 24" X 36" FIRE RATED ACCESS PANEL PER FLOOR AT ALL KITCHEN GREASE SHAFT LOCATIONS AND EVERY OTHER FLOOR FOR ALL OTHER SHAFT LOCATIONS. ACCESS PANELS TO FACE THE PUBLIC CORRIDOR SIDE. COORDINATE MOUNTING HEIGHT WITH ARCHITECT IN THE FIELD. DO NOT RUN PIPELINE, CONDUITS OR ANY DEVICES INTO THE SHAFT ASSEMBLIES. SHAFT ASSEMBLIES TO REMAIN FOR THE SOLE PURPOSE OF THE MECHANICAL DUCTS. ELEVATION 810.00 EQUALS 100'-0" INSTALL FIRE EXTINGUISHER SO THE INTEGRITY OF THE RATED WALL IS MAINTAINED. CONTINUE THE TYPE X GYPSUM BOARD ASSEMBLY BEHIND THE FIRE EXTINGUISHER CABINET. SEE A600 SERIES SHEETS FOR UNIT LAYOUT INFORMATION ALL WOOD SILL PLATES IN WALLS AT PODIUM LEVEL TO BE PRESSURE TREATED. EXTERIOR BEARING WALLS TO BE 1 HOUR RATED. REFER TO STRUCTURAL SHEETS FOR BEARING WALL CONDITIONS. COORDINATE SHAFT WALL ALIGNMENT WITH ARCHITECT TO MAINTAIN REQUIRED RATING IN ADJACENT WALLS. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. INDICATES PARTITION WITH SOUND ATTENUATION INSULATION. REFER TO THE WALL PARTITION SCHEDULE FLOOR PLAN LEGEND 2HR SHAFT WALL UNLESS NOTED OTHERWISE , SEE G SERIES SHEETS FOR WALL TYPE SCHEDULE, RATED ASSEMBLIES AND A600 SERIES SHEETS FOR INTERIOR DETAILS. SHAFT WALL ASSEMBLY TO BE CONTINOUS AND THROUGH THE ROOF. WALL ASSEMBLY TO GO THROUGH THE PODIUM EXCEPT AT SUPPLY AND RETURN AIR FOR RESIDENTIAL CORRIDORS. PROVIDE A HORIZONTAL SHAFT WALL ASSEMBLY AT THE BOTTOM OF THE SHAFT. SEE THE GENERAL NOTES ON THIS SHEET FOR ACCESS PANEL REQUIREMENTS AT SHAFT ENCLOSURE. SEE THE SHAFT ASSEMBLY VERTICAL DETAILS. PLAN ELEVATION MAIL BOX PARCEL BOX LINE INDICATES ORIENTATION OF KEYHOLE FOR FOR ANSI COMPLIANCE SEMI-RECESSED FIRE EXTINGUISHER CABINET. INSTALL FIRE EXTINGUISHER SO THAT THE INTEGRITY OF RATED WALL IS MAINTAINED. CONTINUE TYPE X GYP BOARD ASSEMBLY BEHIND FIRE EXTINGUISHER CABINET. UNIT SHALL NOT ENCROACH MORE THAN 4" INTO THE PATH OF EGRESS. HEARING IMPAIRED UNIT, SEE MEP INFORMATION FOR ADDITIONAL REQUIREMENTS. SEE CODE FLOOR PLANS FOR LOCATIONS TYPE A FULLY ACCESSIBLE UNIT. SEE CODE FLOOR PLANS FOR LOCATIONS REQUIRED 30"X48" WHEELCHAIR CLEARANCE. 48" SHALL BE CENTERED AT SINKS AND KITCHEN RANGE 2'-10" MAXIMUM HEIGHT TO THE TOP OF THE KITCHEN OR BATHROOM SINK RIM. TYP. AT PUBLIC AREAS & TYPE A UNITS * ELECTRIC FIRE PLACE AND GYPSUM BOARD SURROUND TYP. AT ALL 1, 2 AND 3-BEDROOM PENTHOUSE UNITS U.N.O. BALCONY EXT. WALL UNIT INTERIOR VTAC FLOOR PLAN DIAGRAM 1 HR RATED WALL 2 HR RATED WALL 1 /2 HR RATED WALL PORTABLE FIRE EXTINGUISHER TYPICAL ACCESS PANEL LOCATION FOR MECHANICAL UNIT. ACCESS PANEL TO BE PAINTED TO MATCH ADJACENT WALL. MECHANICAL LOUVER. PAINT TO MATCH EXT. FINISH. (VTAC UNIT TO BE INSTALLED AT TYPICAL RESIDENTIAL LEVELS. AT PENTHOUSE LEVEL ONLY, LOCATE CLOSET AND DOOR IN LIEU OF VTAC UNIT) J. CURTIS MOODY 7066 © 2014 Moody/Nolan Inc. for Dwg. Coord.: Tech. Coord.: P R I N T D A T E : F I L E I N F O : Phone: (614) 461-4664 Fax: (614) 280-8881 www.moodynolan.com 300 Spruce Street Suite 300 Columbus, Ohio 43215 CURTIS J. MOODY, LIC. #7066 EXP. DATE: 1 2/31 /201 5 C1 KEY PLAN CITY OF DUBLIN APPROVAL M OONEY STREET B A NK E R DRI VE B R I D G E P A R K A V E N U E M OONEY STREE T L ONGSHORE STREET L ONGSHORE STREET 1 1 / 2 3 / 2 0 1 5 8 : 4 8 : 2 6 A M C : \ $ $ L o c a l R e v i t P r o j e c t s \ 2 0 1 6 P r o j e c t s \ 1 4 1 4 5 - B r i d g e P a r k - B L D G C 1 - A R C H _ G B r i y a . r v t A120 14145 02.05.2015 LEVEL 2 FLOOR PLAN BRIDGE PARK BUILDING C1 CRAWFORD HOYING development Author Checker CD PERMIT / GMP SET 6680 RIVERSIDE DR. DUBLIN, OH 43017 PLAN 1/8" = 1' -0" LEVEL 2 - OVERALL FLOOR PLAN 1 REFER TO SD-1 THRU SD-5 SHEETS FOR AMENITY TERRACE (ROOF GARDEN) LAYOUT 4 4 4 4 4 # DATE CHANGE DESCRIPTION 1 02-17-15 Addendum 1 4 05-6-15 Addendum 4 5 07-29-15 Bulletin 1 13 11-23-15 Bulletin 9 Approved for Construction BPS.15-21145.CO M.CNEW_EPR.171. 33543 03/29/16

Transcript of Approved for Construction BPS.15-21145.CO M.CNEW...

Page 1: Approved for Construction BPS.15-21145.CO M.CNEW …dublinohiousa.gov/dev/dev/wp-content/uploads/2016/08/C1_LEVEL2... · a300 1 a301 2 l a301 15 1 a400 2 3 a400 1 a401 2 a401 stair

A300

1

A301

2

A301

1

1

A400

2

A400

1

A401

2

A401

STAIR 2

S2-200

STAIR 1

S1-200

WD

1

A501

CORRIDOR

C200

A6131

2

A501

1

A502

1

A507

3

A503

A6121

A5611

A5614

1

A505

2

A506

A300

2 3

A504

3

A501

A301

4

2

A505

2

A504

A6021

A6151

3

A505A614

1

ELECT

E200

TRASH

TR200

TRASH

TR201

TR200

E200

AMENITY

A200

A200B

STORAGE

S201

2

A502

1

A503

2

A503

1

A504

1

A506

3

A506

3

A502

A301

3

3

A550

2

A550

ELEVLOBBY

L200

3

A507

ELEV. 1

E1-200

A6513

1 BR

200

STUDIO

202

1 BR

204

1 BR

2061 BR

208

2 BR

210

3 BR

2111 BR

209

2 BR

207

2 BR

205

3 BR

201

1716

15

14

13

13

10 8

6

5

5 4

3 2

B

C

D

G

JH

E

7 12

KK

11.8

A620K7

A200C

AI

4

A551

3'-4"

2

A507

A6522

4

A507

8'-0 1/4" 7'-3 1/8"

TOILET

A200AA200A

5'-3 1/2" 5'-0" 8'-2 1/4" 8'-0" 5'-0" 3'-10" 10'-10" 5'-0" 12'-2" 10'-8 7/8" 5'-0" 12'-3 1/8" 10'-8 7/8" 5'-0" 21'-6 3/8" 5'-0"

7'-1 3

/4"

6'-1

0"

10'-6 1

/4"

2'-10"

41'-2"

21'-8"

11'-0"

8'-8"

7'-4"

2'-0"

12'-0" 10'-4" 14'-0" 14'-6" 6'-6" 6'-8"

2'-8" 4'-0"

55'-11 1/8" 57'-2" 64'-0"

12'-3" 32'-8" 12'-3"

11'-0" 10'-8" 11'-0"

5'-0"

5'-2"

6'-4"

5'-3

3/8

"

1 '-8"

92.00°

2'-10"

5 1/4"

2'-10"

25'-0" 9'-4 1/2" 12'-0"

10'-8 1/8" 1'-3 7/8"

WD

WD

6'-11 1

/4"

10 3

/8"

2'-0"

101'-2

"

1 '-0" 6'-8" 1'-0" 1'-9"

13'-8 3

/4"

20'-2 1

/2"

1 '-9 3/8"5'-8" 10" 5'-6" 10" 2'-6" 12'-4 1/4" 12'-3 3/8" 5'-0" 24'-8" 24'-8" 5'-0" 12'-3 3/8" 21'-2 1/4"

10'-8 7

/8"

5'-0"

11'-3"

10'-3 3

/8"

5'-6 3

/8"

-1'-0"

WC

WC

WS

WS

3D

WD

3C

3C

WC

WC

WC

11H

WD

WD

WC

WD WD

WD

WCWC

WD

WD

WD

WD

WD WD

WC

102'-4 3

/8"

9 '-4"

15'-9

7/8

"1

1'-2

7/8

"9

'- 9 1

/ 2"

A5611

A200

STORAGE

S202S202

S201

A5611

SIM.

6'-3 1

/2"

BALCONYSEE DETAIL:1/A551

11'-9"

11'-8"

BALCONYSEE DETAIL:2/A551

BALCONYSEE DETAIL: 6/A553 SIMILAR

BALCONYSEE DETAIL: 8/A553 SIMILAR

BALCONYSEE DETAIL: 2/A551 SIMILAR

BALCONYSEE DETAIL: 2/A551 SIMILAR

SHAFTACCESSPANEL-ALL LEVELS

SHAFTACCESSPANEL-ALLLEVELS

SHAFTACCESSPANEL-ALLLEVELS

A620I4

4

A501

4

A501

6'-3 1

/2"

6'-0 1

/4"

2

A551

BALCONY 1

BALCONY 2BALCONY 3

BALCONY 4

BALCONY 5

BALCONY 6

BALCONY 7 BALCONY 8

BALCONY 9

BALCONY 10

BALCONY 11

1

1

1

1

1

1

1

1

1

1

1

10

A170

8

A170

3

A170

AW14

4

4

4

4

4

AW9

13'-7 7/8" 1'-0" 13'-0 1/2" 5'-4" 11'-3 1/4" 14'-4" 6'-0" 13'-1 3/4" 8'-7 1/4" 8'-0" 20'-0" 8'-0" 9'-4 1/2" 13'-8 1/4" 11'-6 1/4" 6'-0 1/8" 19'-7 7/8"

1

9

A170

A301 5

A3016

2'-0"

1'-10 7

/8"

TR

201

WS

1'-4

3/4

"

7'-4

7/8

"

6'-0"

10"

SHAFTACCESSPANEL-ALLLEVELS

5

4'-3 1/4" 5'-9 1/4"

10"

8'-2"

5'-2

7/8

"

1'-4 3

/8"

2'-0"

3'-6" 2'-9" 4'-11 3/8"

8"

3'-7 3

/8"

6'-10 1

/2"

3'-0"

WC

WC

5

10"

WS

WS

WS WC

WC

G0031

S1-200

WST

WST

SIM.8'-8" 1'-0"1'-0"

11

A170

12

A170

A1191

2'-5 7/8"

1'-5 3/4"

3'-3 1

/2"

13

GENERAL NOTES - FLOOR PLANALL DIMENSIONS ARE TO FACE OF WALL (UNLESS NOTEDOTHERWISE).SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STEELREINFORCING IN WALL & FLOOR CONSTRUCTION.SEE FINISH SCHEDULE FOR ADDITIONAL INFORMATION OF LOCATIONSAND TYPES OF FINISH MATERIALS.SEE ELEVATIONS AND STRUCTURAL DRAWINGS FOR LOCATIONS OFEXPANSION & CONTROL JOINTS. CONTRACTOR SHALL PROVIDEADDITIONAL INTERIOR CONTROL JOINTS AS REQUIRED TO COMPLYWITH MAXIMUM SPACING REQUIREMENTS IN SPECIFICATIONS ANDNATIONAL MASONRY INSTITUTE. SEE DETAILS ON AXXX.MECHANICAL & ELECTRICAL EQUIPMENT SHALL BE ONHOUSEKEEPING PADS. PADS ARE TO PROVIDED BY THE TRADESUPPLYING THE EQUIPMENT. SEE MECHANICAL AND ELECTRICALDRAWINGS FOR ADDITIONAL INFORMATION. WORK TO BECOORDINATED THROUGH THE GENERAL TRADES CONTRACTOR. PADS4" MIN. 4" THICK W/ W.W.F., UNLESS NOTED OTHERWISE).SEE G SERIES SHEETS FOR WALL TYPE CONSTRUCTION.PROVIDE AN 24" X 36" FIRE RATED ACCESS PANEL PER FLOOR AT ALLKITCHEN GREASE SHAFT LOCATIONS AND EVERY OTHER FLOOR FORALL OTHER SHAFT LOCATIONS. ACCESS PANELS TO FACE THEPUBLIC CORRIDOR SIDE. COORDINATE MOUNTING HEIGHT WITHARCHITECT IN THE FIELD.DO NOT RUN PIPELINE, CONDUITS OR ANY DEVICES INTO THE SHAFTASSEMBLIES. SHAFT ASSEMBLIES TO REMAIN FOR THE SOLEPURPOSE OF THE MECHANICAL DUCTS.ELEVATION 810.00 EQUALS 100'-0"INSTALL FIRE EXTINGUISHER SO THE INTEGRITY OF THE RATED WALLIS MAINTAINED. CONTINUE THE TYPE X GYPSUM BOARD ASSEMBLYBEHIND THE FIRE EXTINGUISHER CABINET.SEE A600 SERIES SHEETS FOR UNIT LAYOUT INFORMATIONALL WOOD SILL PLATES IN WALLS AT PODIUM LEVEL TO BEPRESSURE TREATED.EXTERIOR BEARING WALLS TO BE 1 HOUR RATED. REFER TOSTRUCTURAL SHEETS FOR BEARING WALL CONDITIONS.COORDINATE SHAFT WALL ALIGNMENT WITH ARCHITECT TO MAINTAINREQUIRED RATING IN ADJACENT WALLS.

1.

2.

3.

4.

5.

6. 7.

8.

9. 10.

11.12.

13.

14.

INDICATES PARTITION WITH SOUNDATTENUATION INSULATION. REFER TOTHE WALL PARTITION SCHEDULE

FLOOR PLAN LEGEND

2 HR SHAFT WALL UNLESS NOTED OTHERWISE , SEE G SERIES SHEETS FOR WALL TYPESCHEDULE, RATED ASSEMBLIES AND A600 SERIES SHEETS FOR INTERIOR DETAILS. SHAFTWALL ASSEMBLY TO BE CONTINOUS AND THROUGH THE ROOF. WALL ASSEMBLY TO GOTHROUGH THE PODIUM EXCEPT AT SUPPLY AND RETURN AIR FOR RESIDENTIAL CORRIDORS.PROVIDE A HORIZONTAL SHAFT WALL ASSEMBLY AT THE BOTTOM OF THE SHAFT. SEE THEGENERAL NOTES ON THIS SHEET FOR ACCESS PANEL REQUIREMENTS AT SHAFT ENCLOSURE.SEE THE SHAFT ASSEMBLY VERTICAL DETAILS.

PLAN ELEVATION

MAIL BOX

PARCEL BOX

LINE INDICATES ORIENTATION OF KEYHOLE FOR FOR ANSICOMPLIANCE

SEMI-RECESSED FIRE EXTINGUISHER CABINET. INSTALL FIREEXTINGUISHER SO THAT THE INTEGRITY OF RATED WALL ISMAINTAINED. CONTINUE TYPE X GYP BOARD ASSEMBLYBEHIND FIRE EXTINGUISHER CABINET. UNIT SHALL NOTENCROACH MORE THAN 4" INTO THE PATH OF EGRESS.

HEARING IMPAIRED UNIT, SEE MEP INFORMATION FORADDITIONAL REQUIREMENTS. SEE CODE FLOOR PLANS FORLOCATIONS

TYPE A FULLY ACCESSIBLE UNIT. SEE CODE FLOOR PLANSFOR LOCATIONS

REQUIRED 30"X48" WHEELCHAIR CLEARANCE. 48" SHALL BECENTERED AT SINKS AND KITCHEN RANGE

2'-10" MAXIMUM HEIGHT TO THE TOP OF THE KITCHEN ORBATHROOM SINK RIM. TYP. AT PUBLIC AREAS & TYPE A UNITS*

ELECTRIC FIRE PLACE AND GYPSUM BOARD SURROUND TYP.AT ALL 1, 2 AND 3-BEDROOM PENTHOUSE UNITS U.N.O.

BALCONY

EXT. WALL

UNIT INTERIOR

VTAC FLOOR PLAN DIAGRAM

1 HR RATED WALL

2 HR RATED WALL

1/2 HR RATED WALL

PORTABLE FIRE EXTINGUISHER

TYPICAL ACCESS PANEL LOCATION FORMECHANICAL UNIT. ACCESS PANEL TOBE PAINTED TO MATCH ADJACENT WALL.

MECHANICALLOUVER. PAINTTO MATCHEXT. FINISH.

(VTAC UNIT TO BE INSTALLED AT TYPICALRESIDENTIAL LEVELS. AT PENTHOUSELEVEL ONLY, LOCATE CLOSET AND DOORIN LIEU OF VTAC UNIT)

J.

CURTIS

MOODY

7066

© 2

014 M

oody/

Nola

n Inc.

for

Dwg. Coord.: Tech. Coord.:

PR

INT

DA

TE

:

FIL

E IN

FO

:

Phone: (614) 461-4664Fax: (614) 280-8881

www.moodynolan.com

300 Spruce StreetSuite 300Columbus, Ohio 43215 CURTIS J. MOODY, LIC. #7066

EXP. DATE: 12/31/2015

C1

KEY PLAN

CITY OF DUBLIN APPROVAL

MOONEY STREET

BA

NK

ER

DR

IVE

B

RID

GE

PA

RK

AV

EN

UE

M OONEY STREET

LONGSHORE STREET

L ONGSHORE STREET

11/2

3/2

015 8

:48:2

6 A

M

C:\$$Loc a

l Revi

t P

roj e

cts\

2016 P

roje

c ts\

14145 -

Bridge P

ark

- B

LD

G C

1 -

AR

CH

_G

Briya

.rvt

A120

14145

02.05.2015

LEVEL 2FLOOR PLAN

BRIDGE PARK BUILDING C1

CRAWFORD HOYINGdevelopment

Author Checker

CD PERMIT / GMP SET

6680 RIVERSIDE DR. DUBLIN, OH 43017

PLAN 1/8" = 1'-0"

LEVEL 2 - OVERALL FLOOR PLAN1

REFER TO SD-1 THRU SD-5SHEETS FOR AMENITY TERRACE(ROOF GARDEN) LAYOUT

4

4

4

4

4

# DATE CHANGE DESCRIPTION

1 02-17-15 Addendum 1

4 05-6-15 Addendum 4

5 07-29-15 Bulletin 1

13 11-23-15 Bulletin 9

Approved for ConstructionBPS.15-21145.COM.CNEW_EPR.171.3354303/29/16