Aerohub tq product info
-
Upload
technicqal-sdn-bhd -
Category
Documents
-
view
510 -
download
6
Transcript of Aerohub tq product info
Distributor and Installer
TECHNICQAL SDN. BHD.
TECHNICQAL SDN. BHD., www.technicqal.com 1
forMALAYSIA AIRPORT BERHAD
24 August 2011
A New Generation of Aerosol Fire
Suppression System
HUB TECHNOLOGIES (M) SDN BHD
Existing Fire Suppression
HUB TECHNOLOGIES (M) SDN BHD
Inert gasesArgon, Nitrogen
Water basedHalocarbonHCFC, HFC,CFC
Disadvantages:• Ozone depletion• Damage on property or documents (electrical/electronic)• Damage to property due to corrosive and water residue.• Cause global warming• Danger to human
1st and 2nd Generation
Aerosol
A New Generation Aerosol Fire Suppression (3rd Generation)• Fully organic base +(organic admixture and binder)
• Malaysian invention and patented• Malaysian manufactured• Recognized National Product (SJJB)
What is AEROHUB
Designed byTECHNICQAL SDN BHD
AEROHUB
5
Corporate video
TECHNICQAL SDN. BHD., www.technicqal.com
Main Components
AEROHUB: Technical Characteristics
Igniter
Combustion Chamber
Insulator
Extinguishing Agent
Coolant
Generator HousingFiltration
2 ways of activation
Electrical Signalfrom Control Panel(Manual / Automatic)
Thermal- self activation
AEROHUB: Method of Activation
Total flooding aerosol gives out smoke-like appearanceHolding time up to 60 minutes.
What is AEROHUB
Aerohub aerosol being rapidly generated
Organic coolant
40-45degC
Aerohub: Fire Basics
Three basic elements of fire
Fuel Fuel Fuel
Heat
O2 O2 O2
O H OH
Oxygen
Heat
Fuel
4th Element of fire -Chain CarriersO, H & OH
Note:O –oxygen ionH- Hydrogen ionOH – Hydroxide ionChain carriers –on surface of fire > propagate the fire to grow
TECHNICQAL SDN. BHD., www.technicqal.com
How AEROHUB extinguishes fire
How it works
Fuel Fuel Fuel
Heat
O2 O2 O2
O H OH
Oxygen
K+
K+
Aerohub® solid compound => aerosol (Potassium + Organic admixture).
K+
Chain carrier
O, H & OH
Aerohub aerosol
1.ChemicalRemoval of radicals fire chain carriers
2.PhysicalCooling the fire to a level where the fire cannot re-ignite.( Lowering the temperature but not by freezing the air or equipment)
TECHNICQAL SDN. BHD., www.technicqal.com
How AEROHUB extinguishes fire
How it works
O2 O2 O2
Fuel Fuel Fuel
Flame Chain Broken
KOH
KO
KOH
The Potassium radicals (K*) bind and remove chain carriers (O, H, OH)
Stops propagation of fire => stable products KOH(potash), KO.NO depletion of oxygen
Chain carrierO, H & OH
Removed from the FlameChain
K
K
K
H
HO
O
O
O
Stable Products
KOH
KOH
KO
TECHNICQAL SDN. BHD., www.technicqal.com
Designed byHUB TECHNOLOGIES (M) SDN BHD
AEROHUB: Benefits• Environment and human friendly
Human friendly, NORMALLY OCCUPIED AREA No detrimental effects on water, soil, air, climate and animals No ODP – Ozone Depletion Potential No GWP – Global Warming Potential 100% HALAL
1.Montreal Protocol: 16th Sept 1987BAN CFCs compound eg. Halon 1301 and Halon 1211 (by 2010)
2.Kyoto Protocol: 11th Dec 1997Reduce greenhouse gas emissions (CO2, CH4, N2O, HFC, PFC and SF6) by at least 5% below 1990 levels in the commitment period 2008 (by2012)
AEROHUB: Benefits• Cost savings
Minimal maintenance Minimal space requirement No piping required Non Pressurized ( as compared to those
using pressurised system- eg 600psi, the pressure will be transferred to the enclosed room)
No Leaking: cylinder, solenoid, piping nozzle
AEROHUB: Benefits
Advanced technology No immediate and after effects on
electronic & magnetic equipment
No usage of Nitrobutadien (oily residue) or Nitrocellulose
No formation of toxic or corrosive chlorine compounds.
No Sulfur (cause corrosion), potassium chloride.
No Non-Halal Gelatin
Fast discharge time (1-2 seconds) and easy replacement
Safe, reliable and simple Installation
AEROHUB: Benefits
Other factors: 100 % Malaysian product. Save outflow
of Ringgit. 100% Malaysian invention. File in
patent in Malaysia and Registered.
Skim Jejak Jaya Bumiputra
Maintenance – Local & International support readily available.
Spares – complete set replacement while under warranty.
Lower costs – 15-25% lower than our
competitor.
Chemical Name Formula Average Results Average Conversion
Life Threatening
OxygenO2 20.6vol.% - -
Carbon monoxideCo 1195 ppm 0.12vol.% 0.3 vol.%
Carbon dioxideCo2 0.40 vol % - 20.0 vol%
Nitric oxideNo <1ppm - -
Nitric dioxideNo2 <1ppm - -
Potassium anionK 492mg/m3 - -
Nitrogen trioxideNo3 <23mg/3 - -
pH ScalepH 8.5 - -
Potassium Carbonate
K2CO3 879mg/m3- -
AEROHUB : AGIT Human Toxicity test
Category AEROHUB DYXXXXO HAXXXX ErXFE13 PXXXXXXX
Patent(MALAYSIA)Process & Formulation
Other countries Other countries Other countries-
Other countries
Organic Admixture YES NO NO NO YES
Organic Binder YES NO NO NO NO
Sulfur PolyclorideCyanide
No unknown unknown YES NO
Contains Non-Halal Gelatine
NO UNKNOWN UNKNOWN UNKNOWN YES
CorrosiveNon-corrosive NO NO NO YES YES
Residue:Oily (Nitrobutadien)
Dry
No Yes No No YES
Usage category OCCUPIED OCCUPIED NORMALLYUNOCCUPIED
NORMALLYUNOCCUPIED
NORMALLYUNOCCUPIED
Space Requirement NO STORAGE AREA
REQUIRED
NO STORAGE AREA
REQUIRED
STORAGE AREA REQUIRED
STORAGE AREA REQUIRED
NO STORAGE AREA
REQUIRED
PRODUCT COMPARISON
Category AEROHUB DXXXXXO HXXXXX ErXXX13 PYXXXX
Pipework No piping required
No piping required
YES YES NO
Standby Pressure NOT PRESSURISED
NOT PRESSURISED
HIGH PRESSURE
HIGH PRESSURE
NOT PRESSURISED
Leakage Pressure
Pressure Loss
NO NO YES YES No
Holding Time 45-60 mins 30 mins 5 min. 5 min Uncertain
MaintenanceNo
(MINIMUM)No (MINIMUM) Yes Yes Minimum
Thermal Shock No No Yes Yes No
PRODUCT COMPARISON
Category Ozone Depleting Potential ODP
GWP Global Warming Potential (100yrs vs C02=1
Atmospheric lifetimes (yrs)
Extinguishing concentration
%V.V. g/m3
Mechanism of fire suppression
AEROSOL BASED0 0 0 - Physical
and chemical
HFC BASED:FE25, FM200, FE13
0 1170-2900 36.4 to 264 7-18 chemical
CFC BASEDHalon 1301
10 5600 65 5 chemical
PFC BASED:Naf S 111
0.036 1450 1211.9 chemical
NATURAL GASES:ArgoniteArgotecInergen
CO2
0001
11700001
26400
120
16-18 38 37.5 50
Physical
WATER BASED 0 0 0 0 physical
CHEMICAL POWDER
0 0 0 chemicalOr physical
ENVIRONMENTAL DATA
AEROHUB Certification
INTERNATIONAL CERTIFICATION
• Bureau Veritas
• BOMBA MALAYSIA
• AGIT, FRANCE
• DINAS KEBAKARAN, INDONESIA
• SINGAPORE CIVIL DEFENCE FORCE
TECHNICQAL SDN. BHD., www.technicqal.com
AEROHUB Models available
GENERATOR SPECIFICATIONS :
• Generator housing and all internal components are made of Stainless Steel or Mild Steel to suit the environment.
• Temperature : Operates with +50 to -50 °C• Humidity : Operates up to 96% RH• Warranty : 2 years for manufacturer’s
defect
Model
SS/MS 50
SS/MS 30
SS/MS 20
SS/MS 10
SS/MS 5
SS/MS 2.5
Room
Volume50m3 30m3 20m3 10m3 5m3 2.5m3
TECHNICQAL SDN. BHD., www.technicqal.com
AEROHUB Installation
Blower Room Generator RoomCeiling Flush Mounting
Switchgear Room MCC Room
Inside vehicle Engine
TECHNICQAL SDN. BHD., www.technicqal.com
AEROHUB: Pemasangan
Switchgear Room MCC Room
THE OZONE LAYER IS ALREADY FAST DEPLETING AT THE POLAR REGIONS. WHAT ARE YOU DOING ABOUT IT?
FOOD FOR THOUGHT
TECHNICQAL SDN. BHD., www.technicqal.com
THANK YOUSELAMAT HARI RAYA EIDUL FITRI
AeroHub portableUser friendly & lightweight