20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

download 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

of 8

Transcript of 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

  • 8/9/2019 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

    1/8

    Gas-fired unit heaters for indoor installation

    UDSA & UDSBD model

  • 8/9/2019 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

    2/8

    008 011 015 020 025 030 035Model

    TECHNICAL DATAUDSA

    Within the V3 range there are two distincttypes of heaters;UDSA - models fitted with an axial fan.With a choice of 24 different units and arange of heat output ratings from 8 to 100kW, these models are available with bothhorizontal and vertical down flow air discharge.UDSBD - models fitted with centrifugal blower in horizontal or vertical orientation. Sixteensizes of heaters with heat outputs rangingfrom 15 to 64 kW.Both UDSA and UDSBD heaters are easy toinstall and they are suitable for a wide rangeof commercial and industrial applications suchas retail premises, sports and leisure halls andwarehouses to mention but a few.

    Reznor V3 unit heaters are one of the mosttechnically advanced products available on themarket today. Incorporating a radical new heatexchanger and burner. V3 is compact, light-weight and delivers the highest possible

    standards of energy efficiency andperformance.

    II 2 +H3 UKB22, C12, C32, C42, C52, C62, C82

    Gas categoriesComb. air and venting; Type B & C Installations 1

    Heat input (Hs) kWHeat input (Hi) kW

    Heat output kWThermal efficiency (Hi) %Gas consumption rate

    natural gas G20natural gas G25

    propane G31 kg/hGas connection size (not supply line size)Temperature rise T (1) K

    Sound pressure level 4 dB(A)Sound pressure level 5 dB(A)

    Electrical service (protection class IP 20)

    Weight (net)

    m/hm/h

    Maximum total electrical rating W

    Vent & combustion air connection collars mm

    kg

    Airflow (15) m/hMotor speed rpm

    Recommended maximum hor. mounting height 2

    Horizontal air throw 3mm

    8,8 13,2 17,6 22,0 30,8 35,2 42,2

    7,9 11,9 15,9 19,8 27,8 31,7 38,0

    7,3 11,0 14,6 18,2 25,5 29,2 34,992 92 92 92 92 92 92

    0,84 1,26 1,68 2,10 2,94 3,36 4,02

    0,98 1,46 1,95 2,44 3,42 3,90 4,68

    0,62 0,93 1,24 1,55 2,16 2,47 2,96

    Rc 1/2

    32 32 32 32 32 32 29

    47 46 47 48 50 51 55

    40 39 40 41 43 44 48

    1425 1425 1425 1425 950 950 950

    2,5 2,5 3,0 3,0 3,5 3,5 3,5

    8 10 13 16 20 22 25

    230/240V 1N ~ 50Hz

    121 126 273 333

    80 80 80 80 100 100 100

    30 33 38 40 56 60 88

    680 1020 1360 1700 2385 2725 3510

  • 8/9/2019 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

    3/8

    The titanium stabilised aluminised steel heat

    exchanger is particularly strong and durable

    providing additional temperature resistance.

    Its weld free construction ensures long life.

    Patented self-aligning burner with

    single orifice eliminates possible

    flame impingement and premature

    heat exchanger failure.

    Up to 25% lighter than similar models and

    easy to install.

    Balanced flue wall terminal provides both flue

    outlet and combustion air inlet, thereby reducing

    installation time.

    All connections (gas and electricity) are

    accessible at one side of the heater.

    043 050 055 064 073 085 100

    Energy saving

    Application versatilityBoth horizontal and vertical downflow units are

    available.

    Fourteen different heat outputs from 8 to 100 kW.

    The smallest unit is only 310mm high - making

    it ideal for mounting in confined spaces.

    Units may be suspended or base mounted on a

    suitable support (fixed or pivoting).

    4-way heat exchanger achieves over 92% ther-

    mal efficiency.

    Reduced NOx emissions contribute to protect the

    environment.

    An improved airflow and a new louvre design

    give longer air throws and significantly

    reduce stratification within the

    building. Consequently,

    the units are particularly

    suitable for well insulated

    buildings. If necessary, de-

    stratification fans can be installed.

    The aerodynamic heat exchanger profile enables

    the UDSA model to increase the airflow up to

    40% with a 30% reduction of electrical

    consumption.

    Easy installation and maintenance

    Extended operational life

    Maintenance is very simple thanks to the useof a single gas injector

    for all models.

    II 2 +H3 UKB22, C12, C32, C42, C52, C62, C82

    50,8 58,6 66,0 77,7 88,0 102,7 117,3

    45,8 52,8 59,5 70,0 79,3 92,5 105,7

    42,1 48,6 54,7 64,4 73,0 85,1 97,092 92 92 92 92 92 92

    4,85 5,59 6,30 7,41 8,39 9,79 11,18

    5,64 6,50 7,32 8,62 9,76 11,38 13,00

    3,57 4,12 4,64 5,46 6,18 7,21 8,24

    Rc 3/4

    28 28 28 28 28 28 28

    5 5 54 5 6 56 58 59 59

    47 48 49 49 51 52 52

    950 950 950 950 950 950 950

    3,5 3,5 3,5 4,0 4,0 4,0 4,0

    28 30 30 33 35 36 39

    230/240V 1N ~ 50Hz

    490 490 490 678 848 848 848

    100 100 130 130 130 130 130

    99 99 112 118 143 158 168

    4535 5180 5830 6810 7770 9065 10360

  • 8/9/2019 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

    4/8

    BD

    A C

    M

    NQ P

    FRONT VIEW TOP VIEW

    EF

    5

    SIDE VIEW

    L

    G J

    4

    213

    1. Combustion air inlet 2. Flue connection 3. Gas connection 4. Electrical connections 5. Service panel

    HORIZONTAL MODELUDSA

    ROOF TERMINALBALANCED FLUE WALL AND

    ype C12 Type C12b Type C52

    T

    T

    ype C32 Type B22 Type B22b

    REAR VIEW(all models except for 035,

    043, 050)

    REAR VIEW(models 035, 043, 050)

    MODEL UDSA DIMENSIONS (mm 2) A B C D E F G H J K L M N P Q RSize

    008, 011

    015

    020

    025

    030

    035, 043, 050

    055, 064

    073, 085, 100

    C- type: : the allowed length between the unit heater and the flue terminal amounts to 9m, a 90 bend offering an equivalentresistance of 1.5m and a 45 bend -0.75m

    307 700 267 404 696 546 131 191 129 67 85 413 16 98 350 120

    383 700 343 404 723 546 200 191 139 122 86 413 16 98 350 120

    383 700 343 404 723 546 200 191 139 122 86 413 16 98 350 120

    586 700 546 404 771 546 368 191 222 122 121 413 16 98 350 140

    586 700 546 404 771 546 368 191 222 122 121 413 16 98 350 140

    510 971 456 601 1129 897 371 195 126 166 121 623 33 149 600 140

    663 971 609 601 1138 897 354 207 150 166 204 623 33 149 600 225

    865 1040 812 651 1138 897 562 213 299 186 204 673 33 149 600 225

    KH

    R

  • 8/9/2019 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

    5/8

  • 8/9/2019 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

    6/8

    B22, C12, C32, C42, C52, C62, C82

    TECHNICAL DATAModel 015 020 025 030 035 043 050

    CENTRIFUGAL MODELUDSBD

    UDSBD

    These indirect gas-fired unit heaters have

    separated combustion and an atmospheric

    burner. The units are equipped with a direct

    drive centrifugal blower and they can operate

    effectively at a resistance output of up to 150

    Pa. Furthermore, there is a choice of three

    types of air distribution: plenum type, standard

    outlet grill (fitted with vertical louvres) and

    downturn nozzles. The unit

    Designed for recirculation and air distributionthrough ductwork UDSBD units are ideal for

    open doorway heating (to prevent heat esca-

    ping) or for providing temperature controlled

    space heating.

    is also available in

    vertical downflow orientation in sizes 015, 025,

    035, 043, 050, 055 and 064.

    * outlet grill is optional

    Gas categories

    Comb. air and venting; Type B & C Installations 1

    Heat input (Hs) kWHeat input (Hi) kW

    Heat output kWThermal efficiency (Hi) %Gas consumption rate

    natural gas G20natural gas G25

    propane G31 kg/hGas connection size (not supply line size)Temperature rise T (1) KAirflow (15)

    4

    6

    5

    dB(A)

    Motor speed

    Standard low, mid or high speedRecommended maximum hor. mounting height

    dB(A)

    Horizontal air throw

    2

    Sound pressure level

    3

    Sound pressure levelElectrical service (protection class IP 20)Maximum total electrical ratingWeight (net)

    m/hm/h

    mm

    rpmm/h

    Wkg

    II 2 +H3 UK

    17,6 22,0 30,8 35,2 42,2 50,8 58,615,9 19,8 27,8 31,7 38 45,8 52,8

    1,68 2,10 2,94 3,36 4,02 4,85 5,59

    2150 2350 2750 3360 4080 3900 4900

    950 950 1430 1430 950 950 950

    mid high low mid low low mid

    3,5 4 4,5 4,5 5,5 5,5 6

    1,95 2,44 3,42 3,90 4,68 5,64 6,50

    1,24 1,55 2,16 2,47 2,96 3,57 4,12

    20 23 27 25 25 31 29

    18 23 26 26 32 34 38

    50 52 47 51 46 47 52

    57 58 54 58 53 54 59

    496 496 1662 1662 1700 1700 1700

    50 53 71 74 125 131 131

    14,6 18,2 25,5 29,2 34,9 42,1 48,692 92 92 92 92 92 92

    Rc 1/2 Rc 3/4

    230/240V 1N ~ 50Hz

  • 8/9/2019 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

    7/8

    055 064

    FRONT VIEW TOP VIEWSIDE VIEW

    REAR VIEW REAR VIEW

    Size

    015, 020

    025, 030

    055

    064

    035, 043, 050

    383 460 700 343 404 935 546 199,5 191 139 122 86 413 15,5 98 350 120

    A A1 B C D E F G H J K L M N P Q R

    586 590 700 546 404 1185 546 367,5 191 222 122 121 413 15,5 98 350 140

    510 670 970 456 601 1610 897 371 194 126 165 121 623 33 148,5 600 140

    663 685 970 609 601 1610 897 354 206 150 165 204 623 33 148,5 600 225663 720 970 609 601 1610 897 354 206 150 165 204 623 33 148,5 600 225

    MODEL UDSBD DIMENSIONS (mm 2)

    (models 015, 020,025, 030, 055, 064)

    (models 035, 043,050)

    D

    1) Gas appliance classifications for approved venting methods based onCEN report - CR1749:2001.

    1. Combustion air inlet 2. Flue connection 3. Gas connection 4. Electrical connections 5. Service panel

    Height from floor to bottom surface of the heater. These are RECOM-MENDATIONS ONLY. Positioning of unit heaters for proper performance is application dependent. Operation is affected by other air moving equipment in the space, obstructions to the airflow,draughts and/or close proximity doors or windows, etc. Care shouldbe taken to

    , unless downturn nozzle options are used, as significantstratification may occur, resulting in poor floor coverage and higher

    energy losses trough the roof structure.Isothermal conditions , 20 C ambient air temperature , dischargelouvres , zero deflection , v=0,5m/s.dB(A) values at from the unit with reference circumstances

    dB(A) values at 5 meters from the unit in free field.Values mesured with an external static pressure of 150 Pa.

    avoid mounting the heaters above these recommen-dations

    5 metersA=160m and Q=2.

    2)

    3)

    4)

    5)6)

    66,0 77,759,5 70

    6,30 7,41

    5300 5390

    950 950

    mid high

    6 6

    7,32 8,62

    4,64 5,46

    30 32

    38 38

    50 53

    57 60

    1700 1700

    148 153

    54,7 64,492 92

  • 8/9/2019 20 Reznor Udsa-udsbd Pliant Ci 06.11.20 En

    8/8

    Company Standards and Services: All Reznor products are tested and approved to CE standards. Reznor Europe nv is assessed to GASTEC EN ISO 9001: 2000 Quality Assurance. Reznor offers a service to its customers; including budget schemes, on site technical support and a comprehensive after-salespackage. Reznor reserves the right to change specifications without prior notice.

    Energymizor thermostat with time and temperature

    control for one stage, two stage and modulating

    REZNOR unit heaters. The microprocessor adjusts the

    heating period and the air temperature.

    Several thermostats can be

    connected together.

    Balanced flue wall and roof terminal

    - Aluminised steel plate

    - Adjustable chimney for pitched roof.

    Flue outlet

    Reznor Europe N.V.E-mail: [email protected] www.ReznorOnline.com

    Wijzigingen voorbehouden

    Wall brackets for UDSA models 008-030

    Wall brackets for UDSA models 035-100

    Pivoting wall bracket for UDSA models

    OPTIONS

    Unit heater accessories

    Mounting

    J&M Sabbestraat 130B-8930 Menen

    BelgiumTel. +32(0) 56 52 95 11

    Fax. +32 (0) 56 52 95 33il @t b

    Control equipment

    - Room temperature sensor for space heating.

    - In-duct temperature sensor for warm air inlet system.

    Two stage duct thermostat.

    Two stage burner control

    Modulating burner control

    Destratification thermostatHeat exchanger SS 409

    Propane model

    Vertical louvres

    3

    0 and 60 discharge nozzle

    Diffuser grill with horizontal louvres

    Duct flange

    Constant running fan

    30 or 60 d ischarge nozzle

    Both fixed or pivoting wall brackets are

    available.

    *

    *

    *

    *

    * UDSBD models only

    One or two stage clock

    thermostat with burner

    on indicator and reset.

    Combined thermostat with

    burner on indicator

    and reset-function.