12.00 12.15 sergio bertoglio - publiceren
-
Upload
wocova -
Category
Health & Medicine
-
view
239 -
download
2
Transcript of 12.00 12.15 sergio bertoglio - publiceren
![Page 1: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/1.jpg)
REDUCING CRBSI BY USING PREFILLED NORMAL SALINE SOLUTION SYRINGES WHEN FLUSHING AND LOCKING PORT DEVICES IN ADULT CANCER PATIENTS; A SINGLE INSTITUTION PRELIMINARY STUDY
![Page 2: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/2.jpg)
Disclosure
• No disclosures related to this study
• This research was funded solely with Ins6tu6onal grants
![Page 3: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/3.jpg)
ANALYSIS OF PORT FAILURES IST GENOVA 1990-2008
12.5
10.3
7.1 6.6
4,3 3.9 3,4 3.1
0
2
4
6
8
10
12
14
90-95 95-00 00-05 05-08
FAIL
UR
ES
%
INFECTION MECHANICAL FAILURE OTHERS
0,6 0,5 0,4
![Page 4: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/4.jpg)
PREFILLED SALINE SYRINGES RATIONALE
• SIMPLICITY OF USE
• REDUCTION OF MANIPULATION / CONTAMINATION
• SPARING NURSING TIME
• INCREASE PATIENT/NURSES SAFETY
• POSSIBLE REDUCTION OF CRBSI
• POSSIBLE SUBSTANTIAL SAVINGS
![Page 5: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/5.jpg)
RETROSPECTIVE SINGLE INSTITUTION COHORT STUDY OF 801 IMPLANTED PORTS WITH TWO
DIFFERENT MEANS OF FLUSHING AND LOCKING DEVICES
MANUALLY FILLED VS
PREFILLED NORMAL SALINE SYRINGES
![Page 6: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/6.jpg)
SALINE LOCK EVERY 30-DAYS OR AFTER
EVERY ACCES
801 UNSELECTED CONSECUTIVE IMPLANTED PORTS
( September 2009 – august 2011 )
10 ml normal slaine Prefilled Filled Syringes
PFS Group ( 498 patients)
10 ml normal slaine Manually Filled Syringes MFS Group (303 patients)
MINIMUM FOLLOW-UP : 6 MONTHS
![Page 7: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/7.jpg)
MANUALLY FILLLED vs PREFILLED SALYNE SYRINGES
PRIMARY STUDY OUTCOME
CRBS infection incidence requiring port removal
![Page 8: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/8.jpg)
MANUALLY FILLLED vs PREFILLED SALINE SYRINGES
SECONDARY STUDY OUTCOMES *
• AGE • GENDER • PATHOLOGY • STAGE DISEASE • ACCES SITE • BODY SIDE
* Multivariate analysis
![Page 9: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/9.jpg)
MANUALLY FILLED vs PREFILLEDSALINE SYRINGES
![Page 10: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/10.jpg)
Port removal according to the use of MFS or PFS
![Page 11: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/11.jpg)
Port removal for CRBSI - Multivariate analysis
![Page 12: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/12.jpg)
Port removal for any reason – Multivariate analysis
![Page 13: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/13.jpg)
Pathogenic microorganisms responsible for catheter related bloodstream infection according to the use of MFS and PFS
![Page 14: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/14.jpg)
MANUALLY FILLED vs PREFILLED SALINE SYRINGES
Our study provides support that switching from MFS to PFS use during port flushing and locking procedures is a usefull procedure to significantly reduce the incidence rate of CRBSI.
CONCLUSIONS
![Page 15: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/15.jpg)
MANUALLY FILLED vs PREFILLED SALINE SYRINGES
Further controlled studies are advisable to confirm this result and to eventually assess other potential attractive advantages, such as improving nursing work flow, reducing time to prepare flushing syringes.
CONCLUSIONS
![Page 16: 12.00 12.15 sergio bertoglio - publiceren](https://reader036.fdocument.pub/reader036/viewer/2022062308/558c18a5d8b42add718b4668/html5/thumbnails/16.jpg)
THANK YOU VERY MUCH FOR YOUR ATTENTION