Post on 24-May-2018
% kW g/kW.h L/hStandby Power
100 40 8Prime Power
100 36 7.175 27 5.750 18 4.3Stone guard. Drain Tap
Specifications may change without notice
Spin-on full flow lube oil filter. harmonics and paralleling ability.Cooling Close coupled engine/alternator for perfect40°C ambient temperature standard alignment.
connectors. Standard fuel water separator. anti-tracking varnish.FiltersAir cleaner with dry element. Output windings with 2/3 pitch for improved
injection system with integral electronic Triple dipped in moisture, oil and acid Engine Performance Date@1500RPMgovernor. Dual flexible fuel lines and resisting polyester varnish and coated with Output Power Fuel Consumption
current 1800 amps at 0°C. Sealed for life bearings.Fuel System Layer wound mechanically wedged rotor.12/24 volt fail safe actuator. Spin-on paperelement fuel filters with fuel pump Exciter
Starting grade insulating oil and acid resisting12/24 volt negative earth. Battery charging polyester resin. Dynamically balanced rotoralternator 35 amp on engine. Cranking BS 5625 grade 2.5.
crankshaft and connecting rods, cast iron Epoxy coated stator winding. ISO9001:2000,ISO14000,block. Rotor and exciter impregnated with tropical CE Compliance
Construction Fully interconnected damper winding. AS1359, BS 5514,Two valves per cylinder, forged steel AC exciter and rotating rectifier unit. ISO 3046 and ISO 8528
four cycle, turbocharged pole, drip proof, screen protected. NEMA MG1-22, CEMA,and low temperature aftercooled Class H Insulation, IP23 Protection IEC 34, CSA A22.2,
Type Type To BS4999/5000 pt 99,Cummins water cooled Diesel engine, Brushless single bearing, revolving field, VDE 0530, UTE5100,
In compliance with BS 800 and VDE levelsG and N.
Engine Speci�cation Alternator Speci�cation Quality Standards
THF to BS 4999 Part 40 better than 2%. Automatic Transfer SwitchesAlternator Temperature Rise Packing - Export BoxClass H insulation.Radio Interference
Standard set of labels balanced load in the order of 5.0%. Optional Set mounted starting batteriesTelephone In�uence Factor (TIF) Coolant Heater 240VTIF better than 50. Battery Charger 240V, 5A or 10A
Packing under shrunk plastic film Total harmonic distortion open circuit voltage Miscellaneous OptionsOperation & Maintenance manual waveform in the order of 1.8%. Three-phase 3 pole or 4 pole Circuit Breaker
Munsell Jade Green constant loads – no load to full load. According to customer requirementsRadiator Waveform
Steel base frame with A/V mounting, Random Frequency Variation Voltage ConnectionsEngine, Alternator, Chassis & Control Box Will not exceed ±0.25% of its mean value for 240/416V, 230/400V, 220/380V, 480V
Exciter/Voltage reg - Torque Match as standard load to 100% full load when electronic Installation Kit - Residential SilencerStandard ComAp AMF20 Auto start whith AMF governor is fitted
Single bearing alternator, class H/H Frequency Regulation Exhaust Silencer - Residential , In-LineStandard voltage 400/480 volts 50/60 Hz Isochronous under varying loads from no Installation Kit - Industrial Silencer
with DIY Group. At any variations from Cold to Hot. Exhaust Silencer - Industrial In-LineAt speed droop variations up to 4.5%. Exhaust Bellows
alternator, control system and complete At any power factor between 0.8 and 1.0generating set are all produced by the companies At any variations from No load to Full load. Exhaust Options
Single Source Responsibility Voltage Regulation Fuel optionsDesign, manufacture and testing of engine, Maintains voltage output to within ±1.0%. Fuel Tank
Diesel PoweredGenerating SetsPower By Cummins Engine
DIY-C30R5,50HZ,400V,3P/4WStandby Power:30kVA/24kWStandard Genset Features Generator Performance Generator Set Options
Page:1/3
capability is available at this rating.
Canopy diagram
Δ adding cooling water from top of canopy Δ Control panel and cable design in differentdirections,all the connection wiring in control panel are more neater and firmer.
Note:Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40� )Continuous Power.Theseratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power.
Length(mm) Width(mm) Height(mm) Net Weight(Kgs) Gross Weight(Kgs)2450 1080 1865 1400 1400
1725 950 1500 830 830Canopy Dimensions Weight
Open Type Dimensions WeightLength(mm) Width(mm) Height(mm) Net Weight(Kgs) Gross Weight(Kgs)
Δ lube oil and cooling water drains pipes to Δ exhaust silencing system totally enclosed forexterior of the enclosure operator safely
Δ LED light will be lighting automaticlly when open the door
powder coating Δ emergency stop push buttom (red)mountedon enclosure interior
Excellent Access for Maintenance Δ cooling fan and battery charging alternatorΔ radiator fill access plate fully guarded
The Standby Power is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation
Robust Corrosion Resistant Construction Security and SafetyΔ Black finish stainless stell lock and hinges Δ control panel viewing window in a lockableΔ body made from steel components treated with polyester access door
In accordance with ISO 8528, 3046, BS5514PRIME POWERPrime Power is available continuously during the period of power outage in a variable load application. Variable load should not exceed a 70% average of the prime powerrating during any 24 hour period.A 10% overload capability is available for a period of 1 hour within a 12 hour period of operation.STANDBY POWER
Starting Battery Voltage 24V THD <3%
Battery Type Free-maintanenance Lead Acid THF <2%
Engine Output 27kW Protection Class IP23
Lubrication Capacity 10.9 Liter Alternator Insulation H
Governor Type Electronic Power Factor 0.8
Speed 1500 rpm Alternator Voltage Regulation ±1.0%
Compression Ratio 17.3:1 Voltage Regulator Type AVR
Displacement 3.9 Liter AVR Model -
Air intake way Turbocharged Prime Power 27kVA/22kW
Bore × stroke 102mm X 120mm Excitation Type Brushless self-excitation
Engine Model 4B3.9-G2 Alternator Model VP184G22/22KW
Number of Cylinders 4L Standby Power 30kVA/24kW
Speci�cation
Engine Manufacture DCEC CUMMINS Alternator Manufacture DIY
Page:2/3
Control Panel -ComApThe base mounted control panel in a vibration isolated sheet steel enclosure.The control panel is equipped as follows:
a) Instruments:V, A (3 phase), Hz, kW, kVAr, kWh.b) Controls:Push buttons and LEDs for simple control.c) Control module:Standard collocation is ComAp AMF20 Auto start with AMF.
Main Features :
Δ Wide range of communication interfaces
Δ Battery voltage, engine speed (pickup) measurementΔ Configurable programmable binary inputs and outputsΔ Event based history fileΔ Warm-up and cooling functionsΔ Generator C.B. and Mains C.B. control with feedback and return timerΔ Power and temperature switching binary output
ΔSupport of engines equipped with Electronic Control Unit J1939 interface (25) 1Δ Remote Start operation availableΔ Active SMS / E-mailsΔ Comprehensive diagnostic messages; SPN / FMI codes; KWP2000 supportΔ Automatic or manual start / stop of the gen-setΔ Graphic back-lit LCD displayΔ Parameters adjustable via keyboard or PCΔ Selectable protections alarm / shutdownΔ Configurable analog inputs and outputs
Page:3/3