Post on 13-Apr-2018
7/27/2019 Chassis Ds Gersis
1/11
1-slot or 4-slot Chassis
Raisecom Technology Co., Ltd.
RC001-1-DC Chassis
Slot Number RC001/RC002-4 has 4 slots;
RC001-1 has one slot.
Power Supply AC: 100~240V, 50/60Hz;
DC: -72~-36V DC
WP: 100~240V AC or -72~-36V DC (the WP power supply connector
will adapt to the factual power supply automatically)
Power Protection overcurrent protection, short circuit protection
Network management RC002-4 is a chassis with in-built SNMP agent module. The SNMP
agent module enables the network managment over service modules in
RC002-4 and their peer devices.
In small-capacity situation, Raisecom presents
its 4-slot chassis RC001-4, 4-slot network
manageable chassis RC002-4 and single-slot chassis RC001-1 to meet customer
requirements of installing and/or managing
different service modules, including media
converter, fber optic modem, PDH multiplexer,
interface converter, G.SHDSL modem and
CWDM cards, concentratedly on one platform.
RC001-4 and RC002-4 have identical structure
and dimension.The only difference is that
RC002-4 has an in-built SNMP agent module,
and through which the four service modules
in RC002-4 can be network managed.
Fixed in RC001-1 series single-slot chassis,Raisecom's modular devices become stand-
alone equipments, and can be either placed
on table or mounted on wall or rack with
accessories. The employment of power supply
connector of RC001-1 depends on customer's
need. Except for traditional connector for AC
or DC power supply, an option of connector
for wide-range power supply is provided.
Feature
RC001/RC002-4 Chassis
Compliance
Standards UL,CE,FCC, CSAcomplied with IP30
SpecifcationDimension RC001/002-4:
440x44x266mm (WxHxD)
RC001-1:158x40x200mm (WxHxD)
Power
Consumption
RC001/002-4:40W
RC001-1:10W
Working
Temperature
0~45 degree Celsius
Relative Humidity 5%~95%
Storing
ambience
-40~70 degree Celsius
Ordering InformationRC001-1-AC 1U, 1-slot chassis, with AC power supply connector
RC001-1-DC 1U, 1-slot chassis, with DC power supply connector
RC001-1-WP 1U, 1-slot chassis, with WP wide-range power supply connector that adapts
to the factual power supply (AC or DC) automatically
RC001-1 Rack-
Mount Tray
Accessory for installing RC001-1 chassis on 19" rack, two RC001-1 can be
placed on one tray.
RC001-1 Rack-
Mount Angle
Accessory for installing RC001-1 chassis on 19" rack, one RC001-1 uses
two rack-mount angles
RC001-1 Wall-
Mount Angle
Accessory for installing RC001-1 chassis on wall, one RC001-1 users two
wall-mount angles
RC001-4-AC 1U, 4-slot chassis, with AC power supply connector
RC001-4-DC 1U, 4-slot chassis, with DC power supply connector
RC002-4-AC 1U, 4-slot chassis with in-built SNMP management agent and AC power
supply connector
RC002-4-DC 1U, 4-slot chassis with in-built SNMP management agent and DC power
supply connector
Datasheet
RC001-1-AC/WP Chassis
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
2/11
RC001-1D single-slot chassis
Raisecom Technology Co., Ltd.
RC001-1D Front Panel
Power Supply
Connector
AC power supply connector for AC power supply
or DC power supply connector for DC power supplyor WP power supply connector adapted to the factual power
supply (AC or DC) automaticallyPower Protection overcurrent protectionSlot Number 1 slot, with the width of 2 slot of RC002-16
RC001-1D is a single-slot chassis designed
for service modules that take up 2 slots in
RC002-16. It is applicable for telecom carrierand important enterprise user in the feld of
fnance, electric power, petroleum industry, and
etc. To provide high service capacity, some of
Raisecom's modular devices, including Ethernet
to 4/8E1 interface converters, PDH multiplexers
providing 4/8 E1 channels, and multi-service
multiplexers providing 4/8/16 plus 1 Ethernet
service, occupies 2 slots in RC002-16 . Fixed
in RC001-1D, these modular devices become
stand-alone equipments, and can be eitherplaced on table or mounted on wall or rack with
accessories. The employment of power supply
connector depends on user's need. Except
for traditional connector for AC or DC power
supply, an option of connector for wide-range
power supply is provided.
Feature
Datasheet
Compliance
Ordering Information
Standards CE and UL
SpecifcationsDimension 158x64x200mm(WxHxD)
Power Supply AC 100~240V, 50/60Hz
DC -36V~-72V
Power
Consumption
less than or equal to 15W
Working
Temperature
-5~55 degree Celsius
Humidity 5%~95%
Storing
Temperature
-40~70 degree Celsius
Application
RC001-1D-AC single-slot chassis, with a connector for AC power supplyRC001-1D-DC single-slot chassis, with a connector for DC power supplyRC001-1D-WP single-slot chassis, with a connector automatically adapted to
the factual power supply (AC or DC)Rack-Mount Tray accessory for fxing RC001-1D on to 19-inch rackRack-Mount Angle accessory for fxing RC001-1D on to 19-inch rackWall-Mount Angle accessory for mounting RC001-1D on wall
Service Modules in RC001-1D
Ethernet to E1 Interface Converters
RC954-FE(FX)4E1, RC954-2FE4E1-BL,
RC954-2FE8E1-BLPDH Multiplexer
RC832-120L, RC832-240L(-BL)
Multi-Service PDH Multiplexer
RCMS2802-120LFE(-BL), RCMS2802-
240LFE(-BL), RCMS2802-120LGE(-BL),
RCMS2802-240LGE(-BL)
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
3/11
RC001-1M single-slot network-manageable chassis
Raisecom Technology Co., Ltd.
RC001-1M Front Panel
Power Supply AC power supply, or DC power supply, or both AC and DC
power supplyPower Protection overcurrent protection, short circuit protection, overheat
protectionSlot Number 1 slotInterfaceType 1 SNMP interface for network management
1 CONSOLE interface for initial confguration of SNMPNetwrok
Managementnetwork management over the service module in the RC001-
1M and the device on the opposite side of the communication
RC001-1M is a single-slot chassis with in-built
SNMP management module. It is designed for
telecom carrier and important enterprise user
in the feld of fnance, electric power, petroleum
industry, and etc. Fixed in RC001-1M, modular
media converters, PDH multiplexers, interface
converters, G.SHDSL modems and other
modules designed for 1U slots become stand-
alone and network-manageable equipments.
The SNMP agent module built in RC001-1M
realizes network management function like
confguration management, diagnostics, loop
activation, monitoring and fault management.There is one console port, one Ethernet port
and one slot for modular device on the front
panel. The AC and DC power supply connectors
on the rear panel of RC001-1M provides users
with the fexibility of using AC power supply, or
DC power supply or both of them.
Feature
Datasheet
RC001-1M Rear Panel
Compliance
Ordering InformationRC001-1M single-slot chassis, with inbuilt SNMP network management
agent module, 1 AC and 1 DC power supply connector
Standards CE and UL
SpecifcationsDimension 260x38x190mm(WxHxD)
Power Supply AC 100~240V,0.35A,50/60Hz
DC -48V,0.6A
Power
Consumption
less than or equal to 15W
Working
Temperature
0~45 degree Celsius
Humidity 5%~95%
Storing
Temperature
-40~70 degree Celsius
Application
Service modules working and managed in RC001-1M
RC1~RC6 series media converters
RC8xx series PDH multiplexers providing 1/2/4 E1 channels or 1 DS1 channel or
1 DS3/E3 channel
Multi-service PDH multiplexer RCMS2x01 series and RCMS2802-60GE-BL
RC9xx series Ethernet to E1, Ethernet to DS3/E3, Ethernet to V.35, V.35 to E1
interface converters
OPCOM200 series CWDM modular equipmentsRC1102 series G.SHDSL modem
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91
Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
4/11
RC001-2M dual-slot network-manageable chassis
Raisecom Technology Co., Ltd.
RC001-2M Front Panel
Power Supply Single AC power supply, or single DC power supply, or both
AC and DC power supply with two individual connectors or a
auto-sensing connectorPower Protection overcurrent protection, short circuit protection, overheat
protectionSlot Number 2 slotsInterfaceType 1 SNMP interface for network management
1 CONSOLE interface for initial confguration of SNMPNetwrok
Managementnetwork management over the service module in the RC001-
2M and the device on the opposite side of the communication
RC001-2M is a dual-slot chassis with in-built
SNMP management module. It is designed for
telecom carrier and important enterprise user
in the feld of fnance, electric power, petroleum
industry, and etc. Fixed in RC001-2M, modular
media converters, PDH multiplexers, interface
converters, G.SHDSL modems and other
modules that take up 2 slots in RC002-16
become stand-alone and network-manageable
equipments.The SNMP agent module built
in RC001-2M realizes network management
function like confguration management,
diagnostics, loop activation, monitoring and
fault management. There is one console port,one Ethernet port and two slots for two units
of individual single-slot width modular device
or one unit of 2-slot width modular device on
the front panel. The AC and DC power supply
connectors on the rear panel of RC001-2M
provides users with the fexibility of using AC
power supply, or DC power supply or both of
them.
Feature
Datasheet
RC001-2M Rear Panel
Compliance
Ordering InformationRC001-2M-AC/DC Dual-slot chassis, with in-built SNMP network management
agent module, 1 AC and 1 DC power supply connecters
RC001-2M-WP Dual-slot chassis, with in-built SNMP network managementagent module, 1 AC/DC auto-sensing power supply connecter
RC001-2M-AC Dual-slot chassis, with in-built SNMP network management
agent module, AC power supplyRC001-2M-DC Dual-slot chassis, with in-built SNMP network management
agent module, DC power supply
Standards CE and UL
SpecifcationsDimension 320x65x200mm(WxHxD)
Power Supply AC 100~240V,0.35A,50/60Hz
DC -48V,0.6A
Power
Consumption
less than or equal to 15W
Working
Temperature
0~45 degree Celsius
Humidity 5%~95%
Storing
Temperature
-40~70 degree Celsius
Preliminary
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
5/11
RC001-2M dual-slot network-manageable chassis
Raisecom Technology Co., Ltd.
Datasheet
Typical Application
Dual-slot-width service modules working and managed in RC001-2M (02/2008)RC8xx series PDH multiplexers
RCMS series Multi-service PDH multiplexers
RC9xx series Ethernet over PDH(E1s) inverse multiplexers
One-slot-width service modules working and managed in RC001-2M (02/2008)
RC1xx~RC6xx series media converters
RC8xx series PDH modem and multiplexers
RCMS series Multi-service PDH multiplexers
RC9xx series Ethernet over E1(s), Ethernet over DS3/E3, Ethernet over V.35, V.35 to E1 interfaceconverters and inverse multiplexers
OPCOM200 series CWDM modular equipments
RC1102 series G.SHDSL modems
Warning: The total power consumption of the 2 one-slot-width service modules working in
RC001-2M must not exceed 12W.
Preliminary
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
6/11
RC002-16 16-slot Chassis with SNMP Management
Raisecom Technology Co., Ltd.
RC002-16
Slot Number Up to 16 slots for modular converters
Redundant Power
Supply
Two rear-loading, redundant, load-sharing, hot-swappable AC or DC or one
AC and one DC power supplies
Hot-wappable
power supply
RC002-16 can operate with single or dual AC or DC power supplies.
Each power supply supports a full rack of any combination of cards.
The redundant power supply can be replaced without affecting system
performance
Flexibility Single chassis for various modular converters with a variety of technologies,
rates, interfaces and media
Hot-swappable
modular converters
All cards are hot-swappable and can be replaced without interfering with the
data transmission of other cards
Safety Compliance CE and UL
Effcient Heat
dissipation
Optimal structure for effcient heat dissipation
Network
Management
The chassis can be managed by Raisecom network management platform
Nview iEMS (graphic format), which allowing confguration management,
diagnostics and loop activation, as well as monitoring and fault management
Real-time
confguration and
monitoring
The management software enables the user to change the setup
confguration, get real-time alerts on system status, activate diagnostics, and
receive statistics on system functionality in a graphic format.
Number of slot 16
Power supply Two hot-swappable AC or DC
power supplies
Input power
supply voltage
AC: 185V-265V, 50/60Hz
DC: -36V- -72V
Rated Current 20A
Short CurrentProtection
Yes
Over Current
Protection
30A
Noise 100mVp-p
Port
specifcation
(For NMS1
network
management
card)
CONSOLE: RJ-45
ETH (for SNMP and Telnet):
RJ-45
Cascading port: RJ45
Indicators PWR: for power supply
PS1-5: PS1 for modulesPS1-12: PS1 for 1st fan
PS2-5: PS2 for modules
PS2-12: PS2 for 2nd fan
Dimension 442x130.5x350mm (WxHxD)
Power
consumption
80W (at max load)
Working
ambience
Temp: 0~50 degree Celsius
RH: 5~90% non-condensing
Storage
ambience
Temp: -40~85 degree Celsius
RH: 20~90% non-condensing
Safety
compliance
CE marking
UL
RC002-16 is a 19" rack-mountable 3U platform
which supports two rear-loading, redundant,
load-sharing, hot-swappable AC or DC power
supplies. Up to 16 modular converters can be
installed in the chassis, providing a CO/POP
site solution for connecting up to 16 remote
users (15 with SNMP function).
RC002-16 is manageable access system for
providing full convergence of the Last Mile
with a variety of technologies, rates, interfaces
and media. The system supports standard
technologies G.703/704, G.SHDSL and
IEEE802.3. Each card in the RC002-16 works in
a point-to-point confguration opposite a remote
unit with no connection to the adjacent cards.
This allows each card to support a different
rate, interface or media.All cards are hot-wappable and can be replaced
without interfering with the data transmission of
other cards.
RC002-16 supports SNMP management with
NMS1 card inserted. The network management
software iEMS enables the user to change
the setup confguration, get real-time alerts on
system status, active diagnostics, and receive
statistics on system functionality in a graphic
format.
Specifcation
Feature
Ordering InformationRC001-NMS1 Network management master module for RC series modules, installed into
3U 16-slot chassis
RC001-NMS2 Network management slave module for RC series modules, installed into 3U
16-slot chassis
RC002-16AC/S 3U, 16-slot chassis with one AC power supply connector
RC002-16AC/D 3U, 16-slot chassis with two AC power supply connector
RC002-16DC/S 3U, 16-slot chassis with one DC power supply connector
RC002-16DC/D 3U, 16-slot chassis with two DC power supply connector
RC009-2AC Redundant AC power supply for RC002-16
RC009-2DC Redundant DC power supply for RC002-16
Mount Angle 21 Accessory for installing RC002-16 on 21" rack, two angles for one chassis
Mount Angle 23 Accessory for installing RC002-16 on 23" rack, two angles for one chassisNote: The RC002-16 chassis can be installed on 19" rack directly without any accessory.
Datasheet
RC001-NMS1
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
7/11
Raisecom Technology Co., Ltd.
RC002 Cascade
With management agent master
module RC001-NMS1 and
slave module RC001-NMS2
connecting in the manner shown
on the right, four RC002-16chassis forms a cascade.
At most sixty pairs of
equipments at both local and
remote sites can be managed
through one IP address which
is the IP address of RC001-
NMS1.
Typical Application
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
8/11
RC004-16 Chassis for PDH FOM Modular Devices
Raisecom Technology Co., Ltd.
RC004-16 16-slot Chassis
with SNMP Management
RC004-16 is a 19" rack mountable 10U
16-slot chassis for Raisecom modular type
Fiber Optical Modem (4E1, 8E1, 16E1and 8E1+4ETH) and it has rear-loading,
redundant, load-sharing,hot-swappable AC or
DC power supply. Each card in the RC004-16
works in a point-to-point mode with a remote
unit and so as to provide a CO/POP site
solution for Fiber Optical Modem users. All
cards are hot-swappable and can be replaced
without interferring with the data transmission
of other cards. RC004-16 supports SNMP
network management with RC004-16NMS1
card inserted in slot 0, and along with theRC004-16NMS2 card cascade can be realized
up to 4 RC004-16 chassis. The network
management software NNM enables users to
change the setup confguration, get real-time
alerts on system status, active diagnostics,
and receive statistics on system functionality
in a graphic format.
Feature
Datasheet
Slot Number Up 16 slots for modular converters
Redundant Power
Supply
Two rear-loading, redundant, load-sharing, hot-swappable AC or DC or one
AC and one DC power supplies
Hot-wappable
power supply
RC004-16 can operate with single or dual AC or DC power supplies.
Each power supply supports a full rack of any combination of cards.
The redundant power supply can be replaced without affecting system
performance
Flexibility Single chassis for various modular converters with a variety of technologies,
rates, interfaces and media
Hot-swappable
modular converters
All cards are hot-swappable and can be replaced without interfering with the
data transmission of other cards
High Reliability NEBS Compliant
Safety Compliance CE and UL
Effcient Heat
dissipation
Optimal structure for effcient heat dissipation
Power supply Two hot-swappable AC or DC
power supplies
Input power
supply voltage
AC: 185V-265V, 50/60Hz
DC: -36V- -72VShort Current
Protection
Yes
Dimension 436(W)*440(H)*360(D)mm
Power
consumption
150W (at max load)
Working
ambience
Temp: 0~50 centigrade
RH: 5~90% non-condensing
Storage
ambience
Temp: -40~85 centigrade
RH: 20~90% non-condensing
Specifcation
Compliance
Standard UL
Ordering InformationRC004-16NMS1 Master agent module for network management, installed in slot 0 of
RC004-16 chassis
RC004-16NMS2 Cascade module for network management, installed in slot 0 of RC004-16
chassis
RC004-16AC 10U, 16-slot chassis with one AC power supply
(can provide redundant power supply)
RC004-16DC 10U, 16-slot chassis with one DC power supply
(can provide redundant power supply)
RC007-2AC Redundant power supply for RC004-16 chassis, ACRC007-2DC Redundant power supply for RC004-16 chassis, DC
Mount Angle 19
Center
Accessory for installing RC004-16 chassis on 19" center mounted rack
Note: RC004-16 chassis can be directly installed on normal front mounted
19" rack and need no additioinal mount angle.
Mount Angle 21
Center
Accessory for installing RC004-16 chassis on 21" center mounted rack
RC004-16NMS1
Management Agent Module
RC004-16NMS2
Management Cascade
Module
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
9/11
RC006-1 Series single-slot chassis
Raisecom Technology Co., Ltd.
Construction Single-slot, 19 inch, 1Unit highPower Supply Single AC, or single DC, or AC/DC redundant power supplies
RC006-1 non-management chassis
RC006-1M SNMP interface for management, Console interface for SNMP initial
confguration.
In support of management over service modules in the chassis and
remote devices
In support of online upgrade
Features
Ordering InformationRC006-1-X single-slot chassis for modules in RC006-12
RC006-1M-X single-slot chassis for modules in RC006-12, SNMP managementXindicates the optical port specifcation:
AC: 220V/230VAC power supply;
DC: -48VDC power supply;
AC/DC: AC and DC redundant power supply
Raisecom modem pool RC006-12 could
feed high speed and legacy data service,
leased line service and backhauling of mobile
BTS and connectivity WiMAX CPE of MetroEthernet simultaneously. It could hybrid support
for multiple levels PDH products including
E1 extension PDH fber optical multiplexer,
PCM multiplexer, Ethernet over PDH Inverse
Multiplexer. All of the module in central offce
Datasheet
RC006-1, RC006-1M
modem pool RC006-12 could be deployed in
remote site with single-slot chassis RC006-1
as well to enable customer to save cost for
inventory. Raisecom also offers the single-slotchassis with SNMP & console ports RC006-1M
for single module application in central offce.
SpecifcationConsole port RS-232 standard
RJ-45
9600bps
SNMP port 10/100Mbps
FDX/HDX
Auto-negotiation
IEEE802.3x fow control
Auto-MDI/MDIX
Dimensions 430(W)*44.45(H)*266mm(D)
Power Supply 180VAC~260VAC
-36VDC~-72VDC
+12VDC~+36VDCPower
Consumption
7/27/2019 Chassis Ds Gersis
10/11
RC006-12 12 service slots multi-service modem pool
Raisecom Technology Co., Ltd.
RC006-12 12 service slots
multi-service modem pool
Slot Number 15 slots, 12 slots for service cards, 2 slots for power supply modules and 1
slot for network management card
Redundant Power
Supply
Two front-loading, redundant, load-sharing, hot-swappable dual AC or dual
DC or one AC and one DC power supply
Hot-wappable
power supply
RC006-12 can operate with single or dual AC or DC power supplies.
Each power supply supports a full rack of any combination of cards.
The redundant power supply can be replaced without affecting system
performanceFlexibility Single chassis for various modular cards with a variety of technologies,
rates, interfaces and media, unifed SNMP management for all the modules
Hot-swappable
modular converters
All cards are hot-swappable and can be replaced without interfering with the
data transmission of other cards
Safety Compliance CE and UL
Effcient Heat
dissipation
Optimal structure for effcient heat dissipation
Network
Management
The chassis can be managed by Raisecom network management platform
Nview iEMS (GUI), which allowing confguration management, diagnostics
and loop activation, as well as monitoring and fault management
Real-time
confguration andmonitoring
The management software enables the user to change the setup
confguration, get real-time alerts on system status, activate diagnostics, andreceive statistics on system functionality in a graphic format.
Number of slot 15
12 slots for service cards
2 slots for power supply
modules
1 slot for network
management card
Power supply Two hot-swappable AC or DCpower supplies
Input power
supply voltage
AC: 85V-265V, 50/60Hz
DC: -36V- -72V
Rated Current 20A
Short Current
Protection
Yes
Over Current
Protection
Yes
Noise 100mVp-p
Port
specifcation
(For NMS1network
management
card)
CONSOLE: RJ-45
ETH (for SNMP and Telnet):
RJ-45
Net Weight 4.6kg (with two power
supplies)
Dimension 442(W)*248(H)*267(D)mm
Power
consumption
300W (at max load)
Working
ambience
Temp: -5~50 centigrade
RH: 5~90% non-condensing
Storage
ambience
Temp: -40~85 centigrade
RH: 20~90% non-condensing
RC006-12 is a ETSI complied 19" rack-
mountable 6U high platform which supports
two front-loading, redundant, load-sharing,
hot-swappable AC or DC power supplies. Up
to 12 modular service cards and one network
management card can be installed in the
chassis, providing a CO/POP site solution for
connecting up to 12 remote CPE.
RC006-12 multi-service modem pool feeds
simultaneously high speed and legacy data
service, analog voice service, leased line
service and backhauling of Mobile BTS and
connectivity WiMAX CPE to Metro Ethernet.
It could hybrid support for multiple level PDH
products such as: cost effective E1 extension
PDH product up to 16E1; PCM multiplexer
s analog voice and legacy data service for
enterprise customers; carrier grade multi-service PDH product with up to 16 E1s
(including 1*V.35) and 1*10/100M Ethernet
interface.
Redundant fber optic links and power supply
could guarantee the maximum networking
uptime. Switching over time from primary
fber link to secondary is less than 50ms. This
platform could supply SNMP management,
TELNET, and local craft terminal management
through RS232 interface. Full range of
management makes carrier to easily operate
and monitor local and remote device anywhere.
SpecifcationFeature
Ordering InformationRC006-12-NMS Network management module for RC006-12 chassis
RC006-12AC/S 6U, 12 service slots chassis with one 115V or 230V AC power supply
RC006-12AC/D 6U, 12 service slots chassis with two 115V or 230V AC power supplies
RC006-12DC/S 6U, 12 service slots chassis with one -48V DC power supply
RC006-12DC/D 6U, 12 service slots chassis with two -48V DC power supplies
Bossestasse 9,06484 Quedlinburg,Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: andreas.gerold@gersis.eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
7/27/2019 Chassis Ds Gersis
11/11
Raisecom Technology Co., Ltd.
Typical Applicatioin
Bossestasse 9,06484 Quedlinburg Deutschland
Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E mail: andreas gerold@gersis eu
Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E mail: mikhail litvinko@gersis eu